| Sl No | Description | Qty | Unit | R.KHAISER WORKS CONTRACTOR L1 |
|---|---|---|---|---|
| 1.00 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand,silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering, and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and completed depositing the surplus excavated soil with in the compound in places shown by the departmental officers with intial lead and lifts and cleaning and levelling the site etc.,complete as per TNSS 23 & 24, V, VI (S2), VII, 9,10 | 398 | M3 | 184 ₹73,232 |
| 2.00 | Supply delivery and filling of stone dust in Layer of not more than 15cm thick including watering with all layers and consolidation complying with standard specification including cost and conveyance of sand at site and all labour charges and all other incidential charges etc., complete as per Standard Specification TNSS No. 24 & 25. | 5 | M3 | 248 ₹1,240 |
| 3.00 | Plain Cement Concrete of mix 1 : 4 : 8 (One part of Cement four part of sand eight part of aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. TNDSS NO: 28 V, VI (S2) V,VI (S5A) VII | 51 | M3 | 5,189 ₹2.6 L |
| 4.00Supplying and errecting centering for Sides and Soffits including necessary supports and strutting upto3.29mt height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheets of size 90mm x60mm and 10BG stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 90cm centre to centre and supported by casurina props of 10cm to 13cm dia supported at not more than 75cm centre to centre etc complete Complying with standard Specification without Strutting.( TNSS NO or NBC No 30(S) 86 86 A V, VI(S3)VII | ||||
| 4.01 | Below Ground level | 893 | M2 | 494 ₹4.4 L |
| 4.02 | Ground floor | 392 | M3 | 1,023 ₹4.0 L |
| 4.03 | Ground Floor Column | 54 | M2 | 1,227 ₹66,258 |
| 5.00Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. (No separate payment will be made by the Department for the excess usage of materials) -Footing, Plinth beam, Tie beam/Lintel, Ground Floor Roof beam, salbs, Sloped roof beam and slabs 30 V, VI (S5) VII & 13 | ||||
| 5.01 | Below Ground level | 105 | M3 | 8,195 ₹8.6 L |
| 5.02 | Ground Floor | 11 | M3 | 8,327 ₹91,597 |
Tender Value
₹1.0 Cr
EMD Value
₹1.0 L
Closing Date
20 Dec 2024, 3:00 pmClosed
Executive Officer
6/A, Abdul Kuthus Street
Maintenance of Bus Stand in Polur Town Panchayat
2024_DTP_510641_1
1364/2024/HC-1
Open Tender
Civil Works
180 days
Polur
I class
3 documents required · 3 mandatory
₹0
₹1.0 L
Yes
Polur
25 Feb 2025
13 Dec 2024
20 Dec 2024
13 Dec 2024
20 Dec 2024
13 Dec 2024
13 Dec 2024
Amount
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand,silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering, and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and completed depositing the surplus excavated soil with in the compound in places shown by the departmental officers with intial lead and lifts and cleaning and levelling the site etc.,complete as per TNSS 23 & 24, V, VI (S2), VII, 9,10
Supply delivery and filling of stone dust in Layer of not more than 15cm thick including watering with all layers and consolidation complying with standard specification including cost and conveyance of sand at site and all labour charges and all other incidential charges etc., complete as per Standard Specification TNSS No. 24 & 25.
Plain Cement Concrete of mix 1 : 4 : 8 (One part of Cement four part of sand eight part of aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including formwork and centering labour charges, transporting and placing in position including shoring, strutting, forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. TNDSS NO: 28 V, VI (S2) V,VI (S5A) VII
Supplying and errecting centering for Sides and Soffits including necessary supports and strutting upto3.29mt height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheets of size 90mm x60mm and 10BG stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 90cm centre to centre and supported by casurina props of 10cm to 13cm dia supported at not more than 75cm centre to centre etc complete Complying with standard Specification without Strutting.( TNSS NO or NBC No 30(S) 86 86 A V, VI(S3)VII
Below Ground level
Ground floor
Ground Floor Column
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. (No separate payment will be made by the Department for the excess usage of materials) -Footing, Plinth beam, Tie beam/Lintel, Ground Floor Roof beam, salbs, Sloped roof beam and slabs 30 V, VI (S5) VII & 13
Below Ground level
Ground Floor
Supplying and fabrication & placing in position Steel Reinforcement using TMT rods for all RCC works as per the design given including cost of steel and binding wire etc., Complete Complying with Std Specification TNSS No. 86 & 86 AV, VI (S3) ( S6 ) VII
Vibrated Plain Cement Concrete 1:2:4 (one cement two fine aggregates and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 30 V, VI (S5) VII & 13
Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)
Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications
Plain Cement Concrete 1:8:16 (one cement eight fine aggregates and sixteen coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 30 V, VI (S5) VII & 13
Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"X43/8"X 23/4" standard specification including finishing, curing,etc., complete complying with standard specification 31 & Similar to 31C V, VI (S5) VII
Below Ground level
Ground Floor
Plastering in Cement Mortor 1:5 Mix (one part of Cement,, five part of sand)12mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.TNDSS NO: 56, 57
Special Plastering in Cement Mortor 1:3 Mix (one Cement,, Three sand)10mm thick including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.TNDSS NO: 56, 57
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride)Louvered Ventilators of from the profile the size of outerframe 60mm x 58mm andshutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and100% corrosion free, the profile are multi chamberedsections with wall thick of 2mm. The EPDM rubber (blackcolour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided inthe louvers. The window should be fixed to the wall with100% packing with screws and silicon packing all round theframes. The ventilator should be got approved from theExecutive Engineer before use on work PWD SOR Page No : 109 Sl. No : M - 0674
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.. 39 A
Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) 39A
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 51 (10-1) V, VI (S5) VII, 3
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete as per standard specification and as directed by the deparmental officers 44 H V, VI, (S5A) VII ,3
Painting the new plastered walls with two coats of Exterior emulsion paint (weather proof ) first class quality and of approved colour over a priming coat including thorough scrapping clean removal of dirt etc. complete and including necessary plaster paris putty etc. wherever required.as per (ISI STD) (It mustprovide excellent resistance against the growth of algae and fungi on the walls. And it must offer excellent protection against alkali and UV degradation and the durability period should be 5 years. 61 V, VI (S4) 3
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification..107 V, VI (S1) VII
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
Supplying and fixing in position Urinal partition with White Marble slab (Adanga) 18 mm to 20 mm thick of 4'0'' x 2'0''size and above of best quality including dismantling masonry, if necessary and re-doing the same to original condition, etc., complete complying with standard specification. (The Marble slab should be got approved by the Executive Engineer before use on works).
Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For Electronic regulator). etc, complete as per standard specifications.SD 25
Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for 5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point.etc, complete as per standard specifications SD 38
Supply and fixing of 16 Amps DP switch with metal glad of 500V with fuse and nuetral ( side handle) on suitable TW box PWD earthing (SD. NO 141)
Supply and run of 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in 25mm dia GI Pipe(Class B) suitably bent at both ends with necessary angle iron upright and end supports for mains on 7/20 GI bearer wire for Service connection mains(SD. NO 69)
Supply and Fixing of TNEB meter Board suitable for 32A Single Phase Service connection with 32A Fuse unit (500V) 32A neutral link and earth link (1" x 1/8" Copper Flat) on TW Plank of Size 375mm x 300mm x 19mm with Supporting TW Reepers of 1" thick an either side with Painting with Suitable bolt and nuts for fixing the TW Plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB Meter to Fuse Unit (SD No :125)
Supplying and Fixing of single box type 2 x 20 W LED Light fitting complete with Electronic Choke and Teakwood Round blocks on wall or ceiling with fluorescent tube with PVC unsheathed copper leads from terminals to the fitting.[ PWD Page No ;121 M-1273)
Geological investigation Charges under depost works to investigate the Weeakly Shandy site for Driiling of Borewell including all cost of materials and all other labour charges at the site shown by the department officers.(TWAD Managing Director Lr. No. 2015/AHG - 3/HG/Deposit works/2023/ Dt: 05.05.2023)
Drilling 150 mm Dia bore well in allurial soil or segmentary starate using not by rig by first drilling a pilot bore of 115 mm dia direct rotary mud circulation method, using contractors rig tools fuel labour for drilling, bentonite Labour drilling at the site shown by the department officers.(TWAD Managing Director Lr. No. 251112/Drilling rate/AE4/CoM/2021/ Dt: 27.04.2022)
Supply and delivery of unplasticised ribbed screen PVC casing pipe of the 150mm dia in 3m length with screwed and socket end and centering guide for every 15m length of pipes as per IS / 12818 / 92 and as amended from time to time to suit the borewell upto 80m depth (C.S) with ISI marking including, loading, unloading , freight, stacking and transit insurance charges etc, complete. TWAD Page No : 6 WD M 0029
Supply and delivery of Three phase of 50 lpm 225 m Head Submersible pumpset of Motor ISI/ISO with Three Phase Panel Board WIith to level guard and Auto start as per ISI Specifications including all cost and conveyance to site etc., Complete TWAD Page No :103, 119
Supply and delivery of Three Phase Panel Board - Star Delta with two level Guard and auto start (5.00 HP) suitable for Submersible pumpsets and accessories including all fittings suitable for Submersible pump sets.Panel Board should be provided as per specification. Rates inclusive of Packing, Loading, Freight, Unloading, Stacking, Transit and Insurance charges etc, complete TWAD Page No : 119 WD M 1912
Supply and delivery of following 50 mm dia UPVC Column Pipe and GI Pipes and Other Special materials of good quality including cost of materials and labour with cost for coveyence to site etc Complete complying with standard Specifications. etc.,
50mm dia upvc column pipe
50mm upvc Elbow
50mm upvc Union
50mm upvc Bend
50 mm Gate valvu
50mm GM N.R.V
50mm PVC MTA
50mm END cap
50mm dia GI Flange set
50mm M.S Clamp set
Labour Charges for the Erection of 50 LPM 225 mtr Head Submersible pumpset in borewell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TNICN switches starter, voltmeter,Ammeter, three pilot lamps capacitor single phasing preventor, water level guard and laying and jionting the cables and twin earthing as per IE rules., complete and testing the pumpset and trail run for 10 days.TWAD page No 204 WD M 0871
Supplying laying and jointing PVC Pipes of approved quality and best varity of B Class pipe of the following sizes including fixing G.I specials but excluding cost of such specials cutting threading of pipes and fixing to wall with necessary teak wood plugs, clamps and screws masking holes on the wall or drilling holes in roof and making good the dismandled portions to original conditions with necessary brick work and concrete and plastering where ever necessary with necessary scafolding charges. The pipes are to be painted with two coats of good variety and best approved quality of synthetic enamel paint over a priming coat of red-oxide primer etc., complete.
32mm dia PVC pipe
20mm dia PVC pipe
32mm PVC Elbow
32mm PVC Bend
32mm PVC TEE
32MM PVC End cap
20mm PVC Bend
20mm PVC Elbow
20mm PVC Tee
32mm x 20mm PVC Reducer TEE
4sqmm copper cable
Suppling and fixing in position 15mm.diameter PVC screw down tap (heavy duty) of approved make conforming to I.S.specifications and quality including cost of shellac , thread etc.complying with standard specifications and including cutting and threading wherever necessary.
Supplying and fixing in position first quality and approved variety of 32mm Gun Metal Gate Valve (Heavy type) with I.S.I.mark of the following sizes including cost of Shellac , thread etc,.including labour for cutting and threading of G.I.Pipes etc.,complete complying with standard specifications for both internal and external water Supply arrangements.
Supplying and fixing position PVC Nahani Trap (PVC Nahani Trap of size 100 x 75mm) with stainless steel gratings with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
Supplying and fixing in position best quality 110mm dia P.V.C soil/ waste pipes (6KSC)with Specials having ISI mark and providing leakproof joints including fixing to the wall with P.V.C/ M.S clamps etc., and making connection to all sanitary fittings, dismandling masonry/R.C.C. works wherever necessary and making good the dismandled portion to the original condition, complying with standard specifications.
110mm dia PVC pipe
110mm dia PVC Elbow
110mm dia PVC Tee
Supplying and fixing of 2000 Liters capacity HDPE tank with IS specification IS 10701/96 the tank is meant for outdoor (or)indoor use complete with removable hinged top locking arrangement and to make provision to fix water supply pipe lines, necessary man hole with cover and including all PVC specials pugs, screws nails to fix the tank etc., complete and the tank should fixed firming as directed by the departmental officers. The rate shall be inclusive of all materials, labour conveyance hoisting and fixing charges etc. (The water tank should be got approved by the EE before use on work. TWAD Page no ; 87 WD M 1419
Reinfrced Cement concrete M35 grade design mix for the follwing items. The rate excluding cost of TMT rod, centering , struuting but including cost of mixing placing the concrete in postion vibrating cosolidating finishing and curing the concrete etc complete complying the standard specifications.
Providing Expansion Joint in Runway Slab in accordance with details shown in plate No. of T.N.B.P. I m run etc,complete as per standard specification. PWDOR PageNo: 99, W 0660
Providing and laying, spreading and compacting graded stone aggregates to Wet Mix Macadam 250mm thick specification including premixing the materials with water at OMC in mechnanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in Sub Base/ Base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 406 of MORTH
Providing and laying of 83mm thick high strength type conforming IS 15658-2006 of rubberized interlocking paver block in required sizes of minimum compressive strength of 40 N/mm2 in uniform shape of approved make to be laid in flurrying bone pattern with approved non sticking surface in the top and the rate including leveling the base preparation of sub base with stone dust cushion 100mm thick, laying out the pavement cut the pieces to fit the edge, vibrating the pavers, sweeping transporting, loading unloading and laying of paver block as per standard specification.-10 Sqm paver Block rate PWD SOR Page No; 35
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Tendernotice_2.pdf
PDF • 0.76 MB
BOQ_607247.xls
BOQ • 0.34 MB
BidDoc.pdf
Tender Documents • 0.75 MB
TenderNotice.pdf
Additional Documents • 0.38 MB
Download all tender documents and submit your bid