Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-Finance | ₹4.6 L | L1 | Accepted-Finance Stand First lowest, hence accepted |
| 2 | L2₹5.1 L+₹51,558 (11.2%)Rejected-Finance | ₹5.1 L+₹51,558 (11.2%) | L2 | Rejected-Finance Stand Second lowest,hence rejected |
| 3 | L3₹5.5 L+₹87,193 (19.0%)Rejected-Finance | ₹5.5 L+₹87,193 (19.0%) | L3 | Rejected-Finance Stand Third lowest, hence rejected |
| Sl No | Description | Qty | Unit | NATIONAL AIRCON L1 | UNIVERSAL SALES L3 | S.R. REFRIGERATION AND APPLIANCES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall Inverter split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC
Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) [Draft SOR Final Copy Item no. 2/2.2] M: O-General/Mitsubishi Heavy Duty/Daikin | 6 | Each | 50,000 ₹3,00,000 Lowest | 55,000 ₹3,30,000 | 52,900 ₹3,17,400 |
| 2.00 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
a) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm [Draft SOR Final Copy Item no. 3/3.04] | 32 | RM | 150 ₹4,800 Lowest | 250 ₹8,000 | 200 ₹6,400 |
| 3.00 | b) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm [Draft SOR Final Copy Item no. 3/3.01] | 32 | RM | 150 ₹4,800 Lowest | 250 ₹8,000 | 200 ₹6,400 |
| 4.00 | Supply & Laying of 4 core 2.5 sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/KEI/Polycab as approved by E.I.C) | 35 | Mtr | 150 ₹5,250 Lowest | 300 ₹10,500 | 240 ₹8,400 |
| 5.00 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. [Draft SOR Final Copy Item no. 5] | 12 | Mtr | 70 ₹840 Lowest | 150 ₹1,800 | 100 ₹1,200 |
| 6.00 | Supplying, fabrication & fixing 2 Nos. M.S. Angle of size (50 mm x 50 mmx6mm) for making platform for installation of outdoor unit of 3.0/4.0 TR ceiling concealed AC incl. drilling 2 nos holes in each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be baricated & safe for ODU maintenance. Area of the platform is 2Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access as per direction of EIC. | 4 | no. | 6,500 ₹26,000 Lowest | 7,800 ₹31,200 | 7,300 ₹29,200 |
| 7.00 | Supply & laying 1.1 KV grade 3 core 4 sqmm flexible copper Cable with screw, saddle,drill machine nut bolt etc all necessary items needed for connection. (from starter to A.C outdoor Connection)(make: Havels/ Polycab/ Finolex/ ee/ Gloster as per approved by EIC) | 38 | Mtrs | 200 ₹7,600 Lowest | 300 ₹11,400 | 250 ₹9,500 |
| 8.00 | Supply & fixing automatic single phase AC starter of 21Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of LT/Legrand as per dierction of E.I.C) to be fixed on wall and S & F 4 module a1 modular type switchboard on wallincl. making necessary connections with PVC cu. wire and earth continuity wire etc. | 2 | Each | 8,500 ₹17,000 Lowest | 9,900 ₹19,800 | 9,900 ₹19,800 |
| 9.00 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene / PVC rigid pipe and by the prelaid GI fish wire and making necy. connection as required [E-9/1] a) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [ E-9/1(v)] | 150 | Mtr | 75 ₹11,250 Lowest | 150 ₹22,500 | 100 ₹15,000 |
| 10.00 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (E-16 / 7) a) 25 mm size | 150 | Mtr | 50 ₹7,500 Lowest | 100 ₹15,000 | 100 ₹15,000 |
Tender Value
Refer Docs
EMD Value
₹9,400
Closing Date
4 Jul 2026, 4:00 pmClosed
Assistant Engineer, P.W.Dte. High Court Elecl. SD
Office of the Assistant Engineer, P.W.Dte. High Court Electrical Sub-Division, 1st Floor, Sesqui-Centenary Building, High Court, Calcutta, KOLKATA 700001
Electrical Installation cum renovation and modification type Electrical work for converting the reading room at the ground Floor situated just right side of the Judges Lift into one full-fledged Conference Room at Main Building of the -- AC Work ....
2026_WBPWD_5015887_1
WBPWD/AE-HCESD/NIQ11/2nd/26-27
Open Tender
ELECTRICAL WORKS M/R
Item Rate
10 days
High Court Electrical Sub-Division PWDte.
Please refer Tender documents.
6 documents required · 6 mandatory
₹9,400
21 Sept 2026
23 Jun 2026
6 Jul 2026
23 Jun 2026
4 Jul 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.0 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall Inverter split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5- year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC
Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate:800 CFM (Minimum) Minimum ISEER - 5.0, BEE level - 4-Star(min) [Draft SOR Final Copy Item no. 2/2.2] M: O-General/Mitsubishi Heavy Duty/Daikin | 6 | Each | - | - |
| 0.0 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
a) 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm [Draft SOR Final Copy Item no. 3/3.04] | 32 | RM | - | - |
| 0.0 | b) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm [Draft SOR Final Copy Item no. 3/3.01] | 32 | RM | - | - |
| 0.0 | Supply & Laying of 4 core 2.5 sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Finolex/KEI/Polycab as approved by E.I.C) | 35 | Mtr | - | - |
| 0.0 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. [Draft SOR Final Copy Item no. 5] | 12 | Mtr | - | - |
| 0.0 | Supplying, fabrication & fixing 2 Nos. M.S. Angle of size (50 mm x 50 mmx6mm) for making platform for installation of outdoor unit of 3.0/4.0 TR ceiling concealed AC incl. drilling 2 nos holes in each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be baricated & safe for ODU maintenance. Area of the platform is 2Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access as per direction of EIC. | 4 | no. | - | - |
| 0.0 | Supply & laying 1.1 KV grade 3 core 4 sqmm flexible copper Cable with screw, saddle,drill machine nut bolt etc all necessary items needed for connection. (from starter to A.C outdoor Connection)(make: Havels/ Polycab/ Finolex/ ee/ Gloster as per approved by EIC) | 38 | Mtrs | - | - |
| 0.0 | Supply & fixing automatic single phase AC starter of 21Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of LT/Legrand as per dierction of E.I.C) to be fixed on wall and S & F 4 module a1 modular type switchboard on wallincl. making necessary connections with PVC cu. wire and earth continuity wire etc. | 2 | Each | - | - |
| 0.0 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene / PVC rigid pipe and by the prelaid GI fish wire and making necy. connection as required [E-9/1] a) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [ E-9/1(v)] | 150 | Mtr | - | - |
| 0.0 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (E-16 / 7) a) 25 mm size | 150 | Mtr | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.72 MB
2911ii.pdf
Tender Documents • 0.50 MB
BOQ_5084943.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .