Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.4 LAccepted-AOC BINNAGURI HATKHOLA PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | 1 | Accepted-AOC QUOTED RATES ARE REASONABLE AND ACCEPTED | |
| 2 | 2₹4.5 L+₹3,110 (0.70%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | 2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
23 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BIHTA
AIR FORCE STATION BIHTA - 801103
REPAIR/MAINTENANCE OF SUMMER AND COOLING APPLIANCES AT AF STN DARBHANGA UNDER GE (AF) BIHTA
2023_MES_632394_3
8369/BHT/DBG/E8
Open Tender
Miscellaneous Works
Item Rate
240 days
Darbhanga
CLASS E CATEGORY b(i)
6 documents required · 6 mandatory
₹300
GE (AF) Bihta
₹10,000
Yes
10 Jun 2024
28 Feb 2024
1 Apr 2024
28 Feb 2024
23 Mar 2024
6 Mar 2024
28 Feb 2024 - 2 Mar 2024
Amount
AIR CONDITIONER/WATER COOLER/ REFRIGRATOR: Material and labour for disconnecting electric connection, taking down/keeping aside the air conditioner (Split/Window), Water Cooler and Refrigerator including stabilizer of any make and capacity, servicing the same including cleaning inside by means of cleaning of filter, remove dust from body, tightening of loose nut, bolt, washer, rubber gas kit and tightening of loose wiring, loose connection, replacement of wornout nut, bolt, washers, gaskets etc and necessary cutting, welding/ soldering works with replacement of rusted body parts with new MS/GI Sheets of suitable size and making the equipment fully functional and Re-installation in position and testing complete all as specified and directed by Engineer-in-Charge. Note: (All new spare parts will be measured and paid separately under the appropriate items as supply only of S&F as per the respective item)
Material and labour for detection and rectification of leakages in gas line by necessary brazing in 1.5 Ton/2.0 Ton window/split type AC of any model and any make and ensuring the complete systems leak proof including checking the system and replacement of required spare parts including charging of refrigerant gas R-134/R-134A/22/32/410A with appropriate quantity including testing for smooth functioning all as specified and directed. Note: Spare parts, if required will be measured and paid separately as supply only or S&F as per the respective item.
Material and labour for dismantling of unserviceable/worn out hermetically sealed unit compressor from window /Split type AC and replacement with new compressor suitable for existing model/make of capacity 1.5 TR split/window type AC including brazing with suction and discharge line, checking the system for leak proof inclduing charging of refrigerant gas R-134/R-134A/22/32/410A in appropriate qty after making vaccume the complete system and testing the AC for proper functioning all as directed.
All as per item No. 3.00 here in before but of Capacity 2.0 TR split type AC, complete all as specified and directed.
Supply and fixing the following spares parts required for repairs for window /split type AC of any capacity against item No 1.00 here in above complete all as specified and directed by Engineer -in- Charge . Note : All the repairs shall be carried out at AGE E/M store yard including transportation of equipment from site and re-fixing at site. Cost of transportation shall be deemed included in the unit rates.)
Supply only Cooling coil complete with fins made of copper suitable upto 2Ton/1.5 Ton capacity Window/Split type AC as per existing size and specifications, complete all as specified and directed.
Supply only Condensing coil complete with fins made of copper suitable upto 2Ton/1.5 Ton capacity Window/Split type AC as per existing size and specification, complete all as specified and directed.
Supply only condenser of suitable capacity for AC 1.5/2.0 Ton, complete all as specified and directed.
Supply only Fan motor for water cooler of suitable capacity, complete all as specified and directed.
Supply only Fan blade suitable for AC's blower/ water cooler motor and all as per sample, complete all as specified and directed.
Supply only indoor blower motor for AC's of 1.5/2.0 Ton capacity and all as per sample, complete all as specified and directed.
Supply only outdoor motor incl blades for AC's of 1.5/2.0 Ton capacity and all as per sample, complete all as specified and directed.
Supply only indoor blower for AC's of 1.5/2.0 Ton capacity and all as per sample, complete all as specified and directed.
Supply only condensing coil suitable for water cooler upto 120 Ltr capacity, copper made, complete all as specified and directed.
Supply only Cooling coil suitable for water cooler upto 120 Ltr capacity, copper made, complete all as specified and directed.
Supply only 15 mm bore water outlet tap made of brass chromium plated for water cooler upto 120 Ltr capacity, complete all as specified and directed.
Supply and Fixing of wall mounted stand of split type AC of 2 Ton/1.5 Ton capacity, including taking down old one, complete all as specified and directed.
Supply only Liquid line valves copper made for ACs upto 2 Ton capacity, complete all as specified and directed.
Supply only Refrigerant line valve copper made suitable for ACs upto 2 Ton capacity, complete all as specified and directed.
Supply only Foam insulation heavy duty for suction/discharge pipe for ACs refrigerant line, complete all as specified and directed.
Supply only sensor for AC cooling all as specified as suitable size, complete all as specified and directed.
Supply only Capilary tube for water cooler/ refrigerator/AC all as per exiting size, complete all as specified and directed.
Supply only Vegitable tray for refrigerator all as per sample upto 320 Ltr capacity, complete all as specified and directed.
S & F Running capacitor 80/100 mfd + / - 400 V AC, Suitable for 1.5/2.0 TR window / split type AC including taking down unserviceable old one, complete all as specified and directed.
S & F Starting capacitor 80/100 mfd +/-5% 400 V AC, Suitable for 1.5/2.0 TR window / split type AC including taking down unserviceable old one, complete all as specified and directed.
S & F Over load Relay of water cooler/freezer/Refrizerator including taking down unserviceable old one, complete all as specified and directed.
S & F Thermostat switch ( DT 50-1052), suitable for 1.5 Ton/2 Ton split / window type AC including taking down unserviceable old one, complete all as specified and directed.
S & F Blower/Propeller fan motor Single Phase 230 V AC, 50 Hz as per existing sample for indoor unit including taking down unserviceable old one, complete all as specified and directed.
S & F Blower/Propeller fan motor Single Phase 230 V AC, 50 Hz as per existing sample for outdoor unit including taking down unserviceable old one, complete all as specified and directed.
S & F Strainer/Filter (copper) Suitable for window type AC of 1.5/2.0 TR cooling capacity including taking out the old one, complete all as specified and directed.
Supply and Fixing Electronic Circuit plate (PCB) for Split/Window A/C 1.5 TR/2 TR, both inverter and non inverter type including taking down unserviceable old one, complete all as specified and directed.
M&L for repairing the Electronic circuit plate (PCB) for various types and capacity of air conditioning unit including cleaning the parts of the indoor units, complete all as specified and directed.
Supply and fix 5 KVA capacity Automatic copper wound voltage stabilizer for low and high voltage correction equipped with electronic transistorised relay, time relay for two minute suitable for correction on single phase 50 cycles, AC supply, volt meter, indicator and input voltage 180 V to 300 V and stabilized voltage between 220 ±5%, complete all as specified and directed.
Taking out the unserviceable sealed compressor unit from water cooler and .S&F New Sealed compressor unit of existing sample, suitable for 40/80 Ltr capacity of water cooler.replace with New compressor (duly tested) and checking the complete system for leak proof and including charging of refrigerant gas R-134 A in appropriate quantity and testing for smooth functioning, complete all as specified and directed.
M&L detection and rectification of leakage in gas line by necessary brazing /soldering in water cooler of any capacity, any type and any make and ensuring the system leak proof and replacement of required spare parts Including charging of refrigerant gas R-134 A in appropriate quantity in the system and testing for smooth functioning of water cooler, complete all as specified and directed.
Supply and fixing Running capacitor 25/30 mfd ± 5%, 400 volt for Water Cooler having capacity 40/80 and 150Ltr iincluding taking down unserviceable old one, complete all as specified and directed.
Supply and fixing over load Relay for Water Cooler having capacity 40/80 and 150Ltr including taking down old one, complete all as specified and directed.
Supply and fixing Float valve of 15mm dia non-metallic for Water Cooler having capacity 40/80 and 150Ltr including taking down old one, complete all as specified and directed.
Supply and fixing PVC connection of size 15mm dia for Water Cooler having capacity 40/80 and 150Ltr including taking down unserviceable old one, complete all as specified and directed.
Supply and fixing PVC waste pipe of size 25 mm dia for Water Cooler having capacity 40/80 and 150Ltr including taking down unserviceable old one, complete all as specified and directed.
Supply and fixing copper suction pipe of AC of any capacity incl taking down for suitable size, complete all as specified and directed.
Supply and fixing copper discharge pipe of AC of any capacity incl taking down for suitable size, complete all as specified and directed.
Supply and fixing single pole magnetic contactor for outdoor/indoor AC 220 Volts (Black) including taking down for suitable size, complete all as specified and directed.
Supply and fixing double pole magnetic contactor for outdoor/indoor AC 220 Volts (Black) including taking down for suitable size, complete all as specified and directed.
Supply and fixing drain pipe for ACs of 1.5/2.0 Ton including taking down for suitable size, complete all as specified and directed.
Supply and fixing swing motor for ACs indoor/outdoor of 1.5/2.0 Ton including taking down for suitable size, complete all as specified and directed.
Supply and fixing indoor unit filter for ACs of 1.5/2.0 Ton including taking down for suitable size, complete all as specified and directed.
M&L for detection and rectification of leakages in gas line by necessary brazing in refrigerator of 300/310Ltr capacity of any model and any make and ensuring the complete systems leak proof including charging of refrigerant gas R-134 A with appropriate quantity including testing for smooth functioning and checking the system and replacement of required spare parts and complete all as specified and directed. Note: Spare parts like filter, capillary tube, cooling coil, condensing coil if required will be measured and paid separately.
M& L for replacement of relay, suitable for 300/310 Ltr refrigerator of any make/model including taking down unserviceable old one, complete all as specified and directed.
S & F 2.5 sqmm 3 core PVC insulated and sheathed copper conductor wire with approved colour coding (Phase-red, Neutral-black, Earth-green) complete ISI marked drawn in and including 20 mm bore PVC conduit including taking down old one, complete all as specified and directed.
S & F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with two single core FRLS PVC insulated and unsheathed stranded copper conductor cable 4 sqmm as current carrying conductor and one run of 4.0 sqmm as earth contunity conductor, voltage rating 1100 volt, ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with standard accessories along with one run of FRLS PVC green colour insulated, unsheathed, stranded copper conductor of size 4 sqmm, complete all as specified and directed including taking down old one. Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
S&F Sheet metal enclosure with socket plug top and MCBs single pole with a two pin and earth plug and socket complete with one single pole MCB of "C" series of cap 16-32 Amps including taking out the old one, complete all as specified and directed.
Supply and fix switch socket combination of capacity of 15/16 Amps, 220 volts AC, 6 pin, incl taking out old one, complete all as specified and directed.
Supply and fix plug top of capacity 05/06 Amps with suitable make incl taking out old one, complete all as specified and directed.
Supply and fix plug top of capacity 15/16 Amps with suitable make incl taking out old one, complete all as specified and directed.
S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used single pole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces and colour matching including taking down old one, complete all as specified and directed.
S&F MCB’s single pole, 10 KA ,10 Amp to 32 Amp 240 Volts and of ''B'' series with required wiring connections and lugs etc and erecting in provided enclosure/distribution board, MCBs shall be of current limiting type, ISI marked, conforming to IS 8828-1996, including taking down old one, complete all as specified and directed.
S&F MCB’s single pole and neutral, 10 KA, 32 Amp to 40 Amp, 240 Volts and of ''B'' series with required wiring connections and lugs etc and erecting in provided enclosure/distribution board, MCBs shall be of current limiting type, ISI marked conforming to IS 8828-1996, including taking down old one, complete all as specified and directed.
B.K. ROY & SONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .