Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹19.6 LAWARDED | AWARDED |
Tender Value
₹17.6 L
EMD Value
₹52,000
Closing Date
12 Jul 2025, 10:30 pmClosed
Karnataka Power Corporation Limited
Re-wiring and Electrification of old type-2,3,4,5,6,7 Quarters/office complex by copper wire in shaktinagar colony
KPCL/2025-26/EL/WORK_INDENT3195
KPCL/2025-26/EL/WORK_INDENT3195
Open
Electrical
Two Tender Document System(Two Cover)
KPCL Executive Engineer CPS Office RTPS Raichur
₹500
₹52,000
5 Jul 2025
5 Jul 2025
14 Jul 2025
9 Jul 2025
9 Jul 2025
Re-wiring and Electrification of old type-3,4,5,6,7 Quarters/office complex by copper wire in shaktinagar colony
Releasing of main board, and control board along with switches, sockets, and earthing etc.
wiring for lighting /power circuit using one of FRLS PVC insulated 1100volts grade, multistrand copper conductor single core wire in open or concealed system of wiring as per IS- 694:1990 and confirmi...
wiring for lighting /power circuit using one of FRLS PVC insulated 1100volts grade, multistrand copper conductor single core wire in open or concealed system of wiring as per IS- 694:1990 and confirmi...
wiring for lighting /power circuit using one of FRLS PVC insulated 1100volts grade, multistrand copper conductor single core wire in open or concealed system of wiring as per IS- 694:1990 and confirmi...
Supplying and wiring adopting loop system in existing PVC conduit/ casing using 2X1.5 sqmm (phase and neutral) and 1X1.0 sqmm (Earth wire) FRLS multi-strand PVC insulated cooper wire (confirming to IS...
Medium point above 3m up to 6m length from tapping point to outlet via switch
Long point above 6Mtrs up to 10 Mtrs from tapping point to outlet via switch
Supplying heavy gauge PVC conduit pipe. dia . mm thick confirming to IS 2509 with suitable size bends junction boxes ,adhesive paste etc. and fixing inverted wooden plugs in case of RCC wall / stone s...
Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement ...
Supplying and polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws 12"X9"X2"
Supplying and polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 10"X8"X1.5"
Supplying and polished wood board 8"X6"X1.5"
Supplying .way plastic gang box and fixing using necessary wooden/ rawl/ plugs and screws 2 to 4 Way Gang Box
Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws.
Supplying and fixing/replaceingof 6/16/32/ electrical accessories on existing switch board.- 32A DP Switch
Supplying and fixing/replacing of 6/16/32/ electrical accessories on existing switch board. 6Amps SP switch
6Amps 3 way 5 pin socket
6Amps Bakelite ceiling rose
6Amps lamp holder
6Amps bell push
16Amps 3 way 5 pin socket
Supplying 4mm thick white plastic plate and covering for junction boxes of size.mm conduit using necessary machine screws.- 110 mm
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa...
Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase ...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa...
Supplying & Fixing regular MCCB distribution panel confirm to IS 8828, on wall / wood board / flush mounting using required clamps, bolt & nut etc., with provision for fixing of suitable type capacity...
Supplying and fixing HRC fuse link on existing switch fuse base with watt loss as per IS-13703 Above 63 Amps to 200 Amps
Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. Open Execution -100 Amps
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking ca...
Supplying, fixing and wiring earth leakage miniature circuit breaker (ELMCB) 240 volts/450 volts up to 300mA sensitivity on existing wood /panel board 32-40amps 2 pole
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .