Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.2 Cr+₹52,403 (0.45%)Rejected-Finance | ₹1.2 Cr+₹52,403 (0.45%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.2 Cr+₹6.3 L (5.46%)Rejected-Finance OLD NO 5 NEW NO 7 LAKSHMI GARDENS 3RD FLOOR 4TH STREET RANGARAJAPURAM SRINAGAR COLONY SAIDAPET CHENNAI 600015 | CHENNAI | CHENNAI | TAMIL NADU | 600015 | ₹1.2 Cr+₹6.3 L (5.46%) | L3 | Rejected-Finance L3 |
| 4 | L4₹1.4 Cr+₹28.1 L (24.2%)Rejected-Finance | ₹1.4 Cr+₹28.1 L (24.2%) | L4 | Rejected-Finance L4 |
| 5 | Not Admitted-Fee | - | - | Not Admitted-Fee EMD/Instrument is not valid |
Tender Value
₹1.3 Cr
EMD Value
₹2.6 L
Closing Date
21 Oct 2019, 6:00 pmClosed
O/o ASST.GEN.MANAGER (ENGG CIVIL) CMD II
O/o ASST.GEN.MANAGER (ENGG CIVIL) CMD II 1ST FLOOR OPERATIONAL OFFICES CHENNAI AIRPORT CHENNAI 600016
Extension of existing Bus Lounge /SHA at T4 at Chennai Airport, Chennai.
2019_AAI_33322_1
AAI/CHN/CMD-II/2019/002
Open Tender
Civil Works
Item Rate
90 days
O/o ASST.GEN.MANAGER (ENGG CIVIL) CMD II
AS PER NIT
21 documents required · 21 mandatory
₹1,120
AIRPORTS AUTHORITY OF INDIA
₹2.6 L
26 Mar 2021
10 Oct 2019
24 Oct 2019
11 Oct 2019
21 Oct 2019
15 Oct 2019
11 Oct 2019 - 14 Oct 2019
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. a) All kinds of soil.
Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. Note : 1) Excess/less cement used than specified in this item is payable/ recoverable separately. i) All works above plinth and upto floor V level : a) M-15 grade plain cement concrete. (cement content considered @ 240 kg. /cum)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for all heights : c) Lintels, beams, plinth beams, girders, bressumers and cantilevers
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5.0 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : a) Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. a) Hot finished welded type tubes
Extra for pre finished nosing to treads of steps of granite / stone slab.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. a) Size of Tile 600x600 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. A) 110 mm diameter
Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c,including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: a) 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process.
12 mm cement plaster a) Cement mortar 1:6 (1 cement : 6 fine sand)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade a) Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. a)Metal false ceiling
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. b)Aluminium Composite Panel
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. c)Polycarbonate sheet
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and esting of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall a) 20 mm nominal outer dia Pipes
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : a)For fixed portion i) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : b)For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) i) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia , at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. a) Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account)
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: ( b)Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing and laying Ceramic antiskid floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory , Grey , Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing 1st quality ceramic antiskid floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy , bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shadecomplete.
Dismantling of existing double glazing system including frame work, cover caps etc i/c stacking of materials within 50m lead all complete as per the direction of Engineer-in-charge.
Providing and fixing plywood confirming to IS:303 plain lining on wall/wooden frame work, etc., with necessary screws etc., complete and as per the directions of Engineer-in-charge. a) 12mm thick
Providing and fixing plywood confirming to IS:303 plain lining on wall/wooden frame work, etc., with necessary screws etc., complete and as per the directions of Engineer-in-charge. b) 18mm thick
Providing and fixing 4mm thick aluminium composite panel of approved colour and shade [0.50mm+3mm+0.50mm] manufactured by reputed manufacturer like Alstrong/ Almaster/or equivalent make of approved brand. The composite panel should be made of 3mm thick, 100% virgin and non-toxic polyethylene core sandwiched between two skins of 0.50mm thick aluminium sheet of which one side is having three layers of PVDF coating 23 to 26 microns and other side is service coated with Epoxy paint of approved colour/mill finish. The panel should be sandwiched with Dupont(US) adhesive or adhesive film or equivalent in cladding of walls,columns,and other partitions including, straightening, cutting and bending/grewing,fixing with necessary adhesive, 3M tape wherever required and screws in approved design and patterns with necessary silicon sealent at all joints and junctions etc.complete as per the architectural drawings and as directed by Engineer in charge.
Providing, assembling and supplying structural glaziing with 24mm thick double insulated glazing unit of approved make comprising of 2 glass panel of 6mm SKN 154 double toughened with heat soak + 12mm air gap silver milk finish spacer + 6mm clear tougened with heat soak including dessicant structural silicon sealent etc complete for the required performances as per archiectural drawings, as per approved shop drawings, as specified and as directed by Engineer-in-charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“
Providing high strength Hilti Anchor Rod HIT-V-5.8 M12x180 including drilling of required length fixing injectable mortor HIT-HY200-R/330/2 as per manufacturer's specification complete and as per approved structural drawings, direction of Engineer-in Charge.
Supply and fixing of continuous Aluminium Pressure plates with continuous EPDM gasket including fixing of the pressure plates with SS316 screws at a maximum c/c distance of 300mm and providing continuous tight fit Aluminium cover caps, etc complete as per the directions of Engineer-Incharge
Refixing of dismantled double glazing system to the extruded aluminium tubular frame including all labour, scaffolding etc… but excluding the cost of EPDM, pressure plates & covercaps all complete as per the directions of Engineer incharge.
Providing and fixing 12mm thick compact clear polycarbonate solid sheet for aluminium doors and window shutters and partition frames etc complete as per the direction of Engineer-in charge
Providing and fixing double skin partition made of 8mm thick calcium silicate board with rock wool insulation upto ceiling height consisting of GI frame i/c providing and fixig of frame work made of special section power pressed/roll form GI sheet with zinc coating consisting of floor and wall channel with necessary suitable anchor fastener or metal screws with nylon plugs and the studs fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610mm center to center by 6mm dia bolts and nuts, i/c fixing the studs along both ends of partitions fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450mm center to center and fixing of boards to both side of frame work with dry wall screws on studs, floor and ceiling channels at the spacing of 300mm center to center. The system shall be sound proof and the boards are to be fixed to the frame work with joints staggered to avoid through cracks, MS fixing channel to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, i/c jointing and finishing to a flush finish with recommended jointing compound jointing tape, angle beads at corners, joint finisher and two coats of primer suitable for board as per manufacturer's specification and direction of Engineer -in- charge a) Double skin fire rated board of 8mm thick calcium silicate with rock wool insulation"
Shifting of scrap/dismantled materilas from site to stock yard/dump yard over 50m lead upto 3km using Tataace including labour for loading and unloading materials including keeping airside work area clean at all times etc complete as and when required or as instructed by engineer in charge
Supply and fixing of double door of size 2.4 x 2.2m made of 18mm thick ply with 4mm ACP sheet cladding on both side,& S.S beeding on edges including G.I frame of size 100x70mm with duly filled concrete mix , heavy duty hinges (4 nos. for each door 125x75x4mm), aluminium towerbolts (2 nos. for each door 200x10mm), sliding bolt ( 1 no. on each side 250x100mm), handles ( 2 nos. on each door 125mm with plate 175x32mm with plate) etc complete ., as per the direction of Engineer in charge.
Credit for taking away the dismantled Aluminium sections on payment to AAI etc complete as per the directions of Engineer-in-charge.
Credit for taking away the damaged Aluminium Composite Panels (ACP) on payment to AAI etc complete as per the directions of Engineer-in-charge.
Credit for taking away the damaged / wornout steel sections on payment to AAI etc complete as per the directions of Engineer-in-charge.
BUILTECH ENGINEERING
CREATORS ENGINEERS AND INTERIORS PVT LTD
Aruljothi Infrastructure Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .