Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.1 L+₹49,449 (2.29%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹23.7 L+₹2.1 L (9.58%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹23.8 L+₹2.2 L (10.0%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹24.1 L+₹2.5 L (11.6%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
14 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAMS
GE NAMS AMRITSAR
CERTAIN REPAIR TO STORES, TOILETS AND COOK HOUSE OF OTM ACCN IN UNITS OF DOGRAI BDE UNDER AGE BR-I AT NAMS
2023_MES_613808_1
GE NAMS-52/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE NAMS
CLASS D CATEGORY a(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹68,000
Yes
17 Oct 2023
14 Aug 2023
21 Sept 2023
14 Aug 2023
14 Sept 2023
28 Aug 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450mm x 300mm x 7mm on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, over and including rendering 10mm thick in cement mortar (1:4) , complete all as specified and directed.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 09 sqm but not exceeding 0.11 sqm, in floors etc. laid over 15mm thick screed bed in cement mortar 1:6 and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tile exc 0.18 Sqm but not exceeding 0.36 Sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed..
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or rectangular) area of each tile exc 0.18 Sqm but not exceeding 0.36 Sqm, as in skirting ,dados in vertical surfaces etc and including 10mm thick cement plaster 1:4 complete all as specified and directed.
S&F Vitrified ceramic tiles light shade 10mm thick (square/rectangular) area of each tile exc 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as specified and directed..
M&L for, vitrified tiles, 10mm thick (minimum), (square/ rectangular) polished, area of each tiles exceeding 0.36 Sqm (including 600mmx600mm size) but not exceeding 0.42 Sqm, in skirting/dado, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles and over and including 10mm thick rendering in CM (1:4) complete all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate as in sub base to receive floor finishes including demolition of PCC complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving n. exc 15 cm thick below or above ground level & dispose off debris upto a distance n. exc. 100 mtrs where directed complete all as specified and directed.
Supplying , fixing & Hoisting and fixing in position and connecting, in repairs, 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed. make Sintex
Supplying , fixing & Hoisting and fixing in position and connecting, in repairs, 2000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed. Make sintex
S&F, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Disconnecting, setting aside (or lowering if required) and Cleaning & removing all scale and dirt etc from HDPE water tanks of 500 litres capacity (Tanks placed on top of roof) and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed.
Disconnecting, setting aside (or lowering if required) and Cleaning & removing all scale and dirt etc from HDPE water tanks of 1000 litres capacity (Tanks placed on top of roof) and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed.
Taking down or taking up steel water tubing , galvanised from trenches / walls / floors including all fittings, segregatting and stacking the serviceable pipes and fittings properly at site for re-use all as specified and directed for following bore of pipe :
15mm dia
20mm dia
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 15mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 20mm bore of pipe complete all as specified and directed.
S & F 15MM steel water tubing galvanised ,medium grade with all fittings and fixed complete to walls , or in floors, in old/new situation
S & F 20 MM steel water tubing galvanised ,medium grade with all fittings and fixed complete to walls or in floors, in old/new situation (Make : TATA/JINDAL
Dismantling brick tiles or terracing single layer as in roofing complete all as specified and directed.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
M & L for 50mm avarage thickness PCC 1:2:4 type B1 (using 20 mm graded stone aggregate as roof padding ,hunching, sub base floor, even and smooth without using extra cement for further treatment complete all as specified and directed.
M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen primer 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) applied on primed surface by forced application of heat and roller, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed.
M&L, 40 mm thick brick tiles laid and joints in cement mortar (1:3) over 25 mm thick screed bed in cement morter 1:4 and flush pointing as work proceed complete all as specified and directed.
Description all as per item No 22.00 but except bricks tiles complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets including E- Grid frame work complete all as specified and directed.
Material & labour for gypsum board panel 12 mm thick as in ceiling including T section accessory of galvenised mild steel, GI suspender all as per manufacturer design confirming to IS 2095 and IS 2542 – 1981. Weight of board not less than 7 Kg per Sqm including two coat of Oil bound distemper over a coat of plaster of paris complete all as specified and directed. Note: - Rate quoted shall be deemed to be inclusive of gypsum board, frame work and suspender.
M&L in repair for PVC hollow wall panelling 7 to 8mm thick any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed
S&F, in repairs, 18mm thick, PVC sheet one side prelaminated of approved texture ("Celuca Ply of Rajshree make or equivalent in "Sintex" as approved by GE) as in Kitchen cabinet complete all as specified and directed. (Note:- Each member i.e. shelf, partition & shutter of kitchen cabinet shall be measured and paid separately)
S&F, in repair, for 5 mm thick ACP Aluminium composite pannel board prelaminated one sides with decorative choice laminations and fixed with screws to aluminium frame including aluminium of size pipe 40mmx25mm and 1.5mm thick best quality work complete all as specified and directed.
M&L, in repair,PVC (SWR) gully trap , square or round mounthed, any type of size 125 x 100mm, setting and jointing with tting and jointing with solvent cement cement (1:1) complete all as specified and directed.
S & F in repair for viterous china squating pan of (Orrissa Pattern) size 580 mm white with 'P' or 'S' trap front or back inlet and integral foot rest , including joining, filling and provision of cement concrete bedding 1:5:10, type E2 (excluding flushing cisteern and flush pipe) fixed incl cement concrete bedding as required set complete all as specified and directed.
S & F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints and necessary fittings laid in floors/wall or trenches incl taking down old pipe complete all as specified and directed.
AS CONSTRUCTION
Roop Sons and Co
Santokh Singh and Associates
Chander Mohan Arora Contractor
M/S MAHAJAN CONSTRUCTION CO
Jaspal Construction Co.
M/s MAHAJAN CONSTRUCTION CO.
tarvinder singh
Saini Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .