Loading…
Loading…
Tender Value
₹1.8 Cr
EMD Value
₹2.4 L
Closing Date
13 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER ELG
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.(In this connection scanned copy of Annexure VIB duly filled up must be attached with offer).
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender .Other terms and conditions shall follow of GCC, April 2022. Definition of Similar nature of work has given below (1.1)
Defination of Similar Work :- Definition of Similar nature of work :- As per CEE's letter No. EL/112/0/KM, dated 22.08.2013 : Item Sl. 2.2 under "LT Electrical Works" : Supply , erection, testing and commissioning of electrical wiring in residential quarters/Railway Stations/Service building/High bay Sheds etc. / Supply, erection, testing and commissioning of tubular poles/Octagonal poles and Luminaries including erection of rail poles in streets/yards, washing lines & circulating area with or without timer.
13 conditions · 4 needing a document upload
The following documents should be attached with the tender ( Annexure-V (A) certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. & Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The following documents should be attached with the tender: (i)Scanned copy of Pan Card. (ii)Scanned Copy of EFTMANDATE FORM Duly filled up by the bidder(iii)Tender Document (duly digitally signed by the bidder)
Scanned copy of valid GST (Goods & Service Tax)Registration Certificate.
Scanned copy of valid Trade license or Propitorship Certificate.
List of the Works completed in the last three financial years giving description of work. Organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and date of payment and final value of contract should also be given. (Supportive documents/ certificates from the organization with whom worked/are working should be enclosed) (Please attach scanned copy of Annexure-I duly filled up).
List of works in hand indicating Supportive documents/certificates from the organization with whom worked/are working should be enclosed) description of work, contract value, approximate value of balance work yet to be done and date of award. (Supportive documents/certificates form the organization with whom worked/are working should be enclosed).(Please attach scanned copy of Annexure-IV duly filled up)
Partnership deeds, power of Attorney etc. (if any) : The tender shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of partnership concern he should submit the certified copy of the partnership deed along with the tender authorisation to sign the documents on behalf of the partnership firm. If these documents are not enclosed along with the tender document, the tender will be treated as hearing lease submitted by the individual signing the tender documents. The Railway will not consider any power of Attorney granted by the tender or any changes in the composition of the firm made subsequent to the execution of the contract. It may however recognize such power of Attorney and change after obtaining proper legal advice, the cost of which will be chargeable to the contract.(Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder. As per clause no. 14(e) of GCC'22, the following documents to be uploaded in terms of Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
Railway Officers Associated with tenderer:RAILWAY OFFICERS ASSOCIATED WITH TENDERER 1. ExRailway Officer as tenderer: Should tenderer be a retired Gazetted Officer working before his retirement on any of the Railways owned and administered by the President of India, or should the tenderer being partnership firm have as one of its partners a retired Gazetted Officer as aforesaid, or should the tenderer being an incorporated company have any such retired Officer as one of its Directors, or should the tenderer have in his employment any retired Gazetted Officer as aforesaid, full information of such person shall be submitted along with his tender in the format given in annexure-VI to this chapter of this tender document. (Authority: ACS No.3 to GCC July,2014vide Boards letter No.2014/CEI/CT/O/9/RET dt.22.01.2015)(please attach scanned copy of Annexure-VI duly filled up by the firm).
Option for receiving payment through Letter of Credit . (Please attach scannedcopy of ANNEXURE 1 LC & ANNEXURE 2 LC duly filled up by the firm if optedfor)
Submission of Documents in support of Eligibility Criteria : All documents in support of fulfillment of eligibility criteria with respect to completion of 'Similar Nature of work for technical Eligibility criteria 'and 'Total Contract value for Financial Eligibility Criteria' should be uploaded online in the website with scanned copy at the time of tender bidding with the details. No post - tender communication , in any form will be made or entertained , after opening of tenders in this regard .Railways may however call for the originals of the credentials for verification or any clarifications/Confirmations on the contents of the documents submitted .Eligibility of tenderers shall be decided solely on the basis of the documents submitted alongwith the tender offers and any subsequent document whatsoever submitted in this connection would not be given any cognizance on any account.
The Contractor/(firm) must go through the entire tender document along with all attachment for any kind of guidance regarding execution of the job & payment there after. In case any thing is left out or not clear then they should consult the General Condition of Contract & standard Specification as attached (uploaded ).The bidders are also advised to preserve a copy of entire tender document/ (Set) for their convenience.
Electrical (General) work in connection with "Track Machine Sidings (PI) - 20 Nos".
EL-HWH-25-21-3527~ER
EL-HWH-25-21-3527
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹2.4 L
13 Feb 2026
22 Jan 2026
30 Jan 2026
79 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,75,25,837 | ||
| — | — | — | Above/ 134320.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 460.00 | — | — | |
| — | — | — | Above/ 19560.00 Below/P | ||
| Wiring of 6A / 3 pin Plug board consisting with one plug socket and one 6A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 120.00 | — | — | |
| — | — | — | Above/ 15400.00 Below/P | ||
| Wiring of 6/16A 3 pin Plug board consisting with one 16/6A 3 pin plug socket and one 16A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 40.00 | — | — | |
| — | — | — | Above/ 16440.00 Below/P | ||
| Wiring of Multi Plug board consisting with three nos. 6/16A 3 pin plug socket, three nos. 6A switch, one no. 6/16A 3 pin plug socket, one no. 16A switch, one no. 10A fuse kit-kat / MCB and one indicator ( Red ) by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4 sq. mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 40.00 | — | — | |
| — | — | — | Above/ 68000.00 Below/P | ||
| Wiring of Submain by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 1000.00 | — | — | |
| — | — | — | Above/ 74400.00 Below/P | ||
| Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 6.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 600.00 | — | — | |
| — | — | — | Above/ 40260.00 Below/P | ||
| Extra cost for conceal wiring in respect to PVC conduit / casing for light, fan, plug, power plug, multi-plug point etc. including make good of wall surface as its original condition | — | 660.00 | — | — | |
| — | — | — | Above/ 30400.00 Below/P | ||
| Extra cost for conceal wiring for main / submain with respect to PVC conduit / casing including make good of wall surface as its original condition | — | 1600.00 | — | — | |
| — | — | — | Above/ 107800.00 Below/P | ||
| Extra cost involvement for modular switch, bell push, plug socket, fan regulator, USB point, TV socket etc. with other accessories ( Make of Modular switch, socket, box, cover plate etc. - ABB / Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 1100.00 | — | — | |
| — | — | — | Above/ 74400.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 600.00 | — | — | |
| — | — | — | Above/ 174000.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in GI conduit of suitable dia along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 1200.00 | — | — | |
| — | — | — | Above/ 29600.00 Below/P | ||
| Fixing, connection, testing and commissioning of indoor LED luminaire fittings with suitable arrangement. ( LED indoor light fitting will be supplied by Railway ) | — | 400.00 | — | — | |
| — | — | — | Above/ 9360.00 Below/P | ||
| Fixing, connection and commissioning of Street Light luminaire with suitable dia heavy gauge GI bend pipe with GI clamps made of GI flat of size 40mm x 6mm and GI nut-bolts on structure / wall ( LED Street light fitting will be supplied by Railway ) | — | 40.00 | — | — | |
| — | — | — | Above/ 17184.00 Below/P | ||
| Fixing, connection and commissioning of out door LED Flood light / Street Light fitting on High Mast Tower / Pole / Structure with suitable arrangement. ( LED outdoor / street light fitting will be supplied by Railway ) | — | 96.00 | — | — | |
| — | — | — | Above/ 6240.00 Below/P | ||
| Fixing, connection and commissioning of BLDC Ceiling fan with suitable size GI clamps made of GI flat and GI nut-bolts. ( BLDC Ceiling Fan will be supplied by Railway ) | — | 120.00 | — | — | |
| — | — | — | Above/ 22080.00 Below/P | ||
| Supply of Down Rod made of heavy gauge GI pipe of size 20mm dia for suspension of ceiling fan. ( Make - TATA / Jindal / Bansal ) | — | 120.00 | — | — | |
| — | — | — | Above/ 6600.00 Below/P | ||
| Fixing, connection and commissioning of AC Exhaust Fan with suitable size and shape GI clamps / GI nut & bolts including necessary masonry work ( AC Exhaust Fan will be supplied by Railway ) | — | 40.00 | — | — | |
| — | — | — | Above/ 100880.00 Below/P | ||
| Supply of SPN DB ( Metal Enclosure with Metal Door ), 8 way, 50Hz, complete with 4 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz as per requirement of load and 1 no. DP RCBO of current rating 40A, 300mA, 10kA, 230V, 50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) | — | 20.00 | — | — | |
| — | — | — | Above/ 2420.00 Below/P | ||
| Fixing, connection and commissioning of above SPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | 20.00 | — | — | |
| — | — | — | Above/ 1564700.00 Below/P | ||
| Supply of LT cubicle type indoor wall / floor mounted Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following : a) MCCB with Microprocessor Release of breaking capacity 36kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication suitable for Release Range ( 25-63 ) Amp, 4 Pole - 1 no. b) MCB, 4 Pole, 32Amp, 415V, 50Hz, 10kA ( C-curve ) - 2 nos. c) MCB, 2 Pole, 10Amp, 240V, 50Hz, 10kA ( C-curve ) - 2 nos. d) Power Contactor, 3 Pole, 12A, 415V, 50Hz - 2 nos. e) Astronomical Timer Switch - 2 nos. f) Tinned Copper Busbar ( 4 Bar ) each of capacity 100 Amps., 415V, 50 Hz - 1 set g) Static Multifunction panel mounting LED Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Cl 1 with provision of RS485 having display parameters - V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhours, On hours, Phase angle, Interrupts, THD, Events ( High-Low ), Neutral Current, K Factor - 1 no. h) CT of suitable ratio for MFM - 3 nos. i) LED indication lamp for Phases and "ON & OFF" indication for operating status of breakers - 6 nos.complete with all other accessories, internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade along with fabrication work, cable glanding, socketing etc. ( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Energy Meter - ABB / Schneider / Secure / Legrand / LK (L&T) / Genus / Conzerv / Elmeasure / Stelmec / HPL / Socomec / Anchor ) | — | 20.00 | — | — | |
| — | — | — | Above/ 79280.00 Below/P | ||
| Fixing, connection, testing and commissioning of above panel including all incoming and outgoing cables glanding, cable socketing and connection and construction of concrete foundation or suitable wall hanging arrangement as per site condition with all associated accessories. | — | 20.00 | — | — | |
| — | — | — | Above/ 26300.00 Below/P | ||
| Supply of MCB DP, 40A, 1Ph, 240V, 50 Hz, 10kA with polycar- bonate distribution box enclosure (IP-65) with polycarbonate trans- parent openable window including fixing, connection, testing and commissioning. ( Make of MCB - L&T/Siemens/ABB/Hager/Legrand/Schneider and Enclosure Board - Grasp/OBO Bettermann/ABB/Schneider ) | — | 20.00 | — | — | |
| — | — | — | Above/ 153820.00 Below/P | ||
| Supply of Dust and vermin proof metal Busbar Chamber made of 16 SWG ( 1.6mm ) MS sheet duly powder coated consisting of 4 nos. tinned copper busbar of each bar of capacity 100 Amp, 4 way, suitable for 415V, 50Hz supply system including all accessories alongwith fixing, connection, testing and commissioning of incoming and outgoing cables glanding, cable socketing and connection with all suitable arrangement. ( Make - Havells / Standard / HPL / C&S / LK (L&T) / Indoasian ) | — | 20.00 | — | — | |
| — | — | — | Above/ 1638000.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting with covering of cable through suitabe dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 or higher) along with refilling the trench and make good of surface as its original condition ( Cable will be supplied by Railway ) | — | 7000.00 | — | — | |
| — | — | — | Above/ 3678400.00 Below/P | ||
| Trenching and laying of cable under ground by soil cutting with covering of cable through suitable dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN-10 or higher) alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway ) | — | 24200.00 | — | — | |
| — | — | — | Above/ 51000.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 600.00 | — | — | |
| — | — | — | Above/ 421800.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 600.00 | — | — | |
| — | — | — | Above/ 80000.00 Below/P | ||
| Drawing of cable on wall / structure with suitable size and shape GI clamps including supply of suitable size GI Clamp and GI nut- bolts and commissioning of cable ( Cable will be supplied by Railway ) | — | 2000.00 | — | — | |
| — | — | — | Above/ 72100.00 Below/P | ||
| Trenching, laying under road / track through 50 mm dia GI pipe ( medium gauge ) including supply of GI pipe and commi- ssioning of cable including back filling of trench with excavated soil after laying of cable ( Cable will be supplied by Railway ) | — | 350.00 | — | — | |
| — | — | — | Above/ 69200.00 Below/P | ||
| Drawing of cable through one no. 2" dia, 3.0 Mtrs. long GI pipe ( Make - Tata / Jindal / Bansal ) for protection of cable on pole with proper GI clamps and GI nuts & bolts including supply of GI pipe ( Cable will be supplied by Railway ) | — | 80.00 | — | — | |
| — | — | — | Above/ 346160.00 Below/P | ||
| Supply of GI ( minimum coating thickness 65 microns ) conical / octagonal ( minimum sheet thickness - 3mm ) Pole of overall length 7 M with single / double arm bracket, top cover, base plate including hinged door-inbuilt Junction box complete with copper bar, insulator, Hylam sheet for cable termination and fuse kit-kat / MCB ( Make - Utkarsh / B.P. Projects / Crompton / Bajaj / Surya ) | — | 40.00 | — | — | |
| — | — | — | Above/ 2831460.00 Below/P | ||
| Supply of GI ( minimum coating thickness 65 microns ) conical / octagonal ( minimum sheet thickness - 3mm ) Pole of overall length 5 M with single / double arm bracket, top cover, base plate including hinged door-inbuilt Junction box complete with copper bar, insulator, Hylam sheet for cable termination and fuse kit-kat / MCB ( Make - Utkarsh / B.P. Projects / Crompton / Bajaj / Surya ) | — | 410.00 | — | — | |
| — | — | — | Above/ 257088.00 Below/P | ||
| Supply of GI ( minimum coating thickness 65 microns ) conical / octagonal ( minimum sheet thickness - 3mm ) Pole of overall length 3 M with single / double arm bracket, top cover, base plate including hinged door-inbuilt Junction box complete with copper bar, insulator, Hylam sheet for cable termination and fuse kit-kat / MCB ( Make - Utkarsh / B.P. Projects / Crompton / Bajaj / Surya ) | — | 48.00 | — | — | |
| — | — | — | Above/ 1551768.00 Below/P | ||
| RCC foundation, erection and commissioning of above GI pole with construction of cement concrete muffing ( Cement : Stone : Sand = 1 : 2 : 4 ) with foundation accessories including earthing of pole with 1 no. of 50 mm dia, 3 M long GI pipe ( Make - TATA / Jindal / Bansal ) with necessary earth connection from pipe to pole by GI Strip / GI wire | — | 498.00 | — | — | |
| — | — | — | Above/ 178284.00 Below/P | ||
| Wiring of light point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral through pole from inbuilt pole Junction Box's porcelain fuse kit-kat / MCB to light fitting along with 1 no. single core HRFR / FRLS grade, PVC insulated copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ). ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 996.00 | — | — | |
| — | — | — | Above/ 546560.00 Below/P | ||
| Supply of energy efficient bore well submersible pump-motor set of pump discharge capacity approx.1.00 LPS ( approx. 850 GPH ) and discharge head 54 mtrs. ( approx. 177 feet ) complete with water cooled and water lubricated copper wire wound squirrel cage induction motor suitable for 1 Phase, 240 Volt, 50 Hz power supply system with stainless steel coupling and all other accessories such as suitable length 3 core flat copper conductor cable of size 1.5 sq.mm, 1100 Volt grade ( motor to starter panel ), total 30 mtrs. length 40 mm. dia heavy gauge GI column pipe, one non-return valve, two pairs erection clamps etc. alongwith one control panel consisting with MCB, single phase DOL starter, voltmeter, ammeter, water level indicator, LED indications etc.including installation, testing and commissioning. ( Make of pump-motor set - KSB / Texmo / CRI / Kirloskar / Crompton / Calama ) ( Make of GI column pipe - Tata / Jindal / Bansal ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 20.00 | — | — | |
| — | — | — | Above/ 257660.00 Below/P | ||
| Supply of energy efficient bore well submersible pump-motor set of pump discharge capacity approx.1.00 LPS ( approx. 850 GPH ) and discharge head 54 mtrs. ( approx. 177 feet ) complete with water cooled and water lubricated copper wire wound squirrel cage induction motor suitable for 1 Phase, 240 Volt, 50 Hz power supply system with stainless steel coupling and all other accessories such as suitable length 3 core flat copper conductor cable of size 1.5 sq.mm, 1100 Volt grade ( motor to starter panel ), total 30 mtrs. length 40 mm. dia heavy gauge GI column pipe, one non-return valve, two pairs erection clamps etc. alongwith one control panel consisting with MCB, single phase DOL starter, voltmeter, ammeter, water level indicator, LED indications etc. ( Make of pump-motor set - KSB / Texmo / CRI / Kirloskar / Crompton / Calama ) ( Make of GI column pipe - Tata / Jindal / Bansal ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 10.00 | — | — | |
| — | — | — | Above/ 99480.00 Below/P | ||
| Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) | — | 40.00 | — | — | |
| — | — | — | Above/ 2673433.00 Below/P | ||
| Goods & Services Tax ( at present @ 18% ) | Lumpsum | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .