Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC P O BHOLARDABRI ALIPURDUAR JN ALIPURDUAR | ALIPURDUAR | ALIPURDUAR | WEST BENGAL | ₹1.4 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹1.5 Cr+₹8.1 L (5.79%)Rejected-Finance COOCH BEHAR | JALPAIGURI | WEST BENGAL | 735122 | ₹1.5 Cr+₹8.1 L (5.79%) | L2 | Rejected-Finance HIGHEST |
| 3 | L3₹1.6 Cr+₹19.8 L (14.1%)Rejected-Finance 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | ₹1.6 Cr+₹19.8 L (14.1%) | L3 | Rejected-Finance HIGHEST |
| 4 | L4₹1.7 Cr+₹29.7 L (21.2%)Rejected-Finance | ₹1.7 Cr+₹29.7 L (21.2%) | L4 | Rejected-Finance HIGHEST |
| 5 | L5₹1.7 Cr+₹31.0 L (22.1%)Rejected-Finance | ₹1.7 Cr+₹31.0 L (22.1%) | L5 | Rejected-Finance HIGHEST |
Tender Value
Refer Docs
EMD Value
₹2.6 L
Closing Date
24 Sept 2021, 2:00 pmClosed
Superintending Engineer PWD Electrical
Superintending Engineer PWD North Bengal Electrical Circle P.W.D Inspection Bungalow Annex Building 1ST Floor Kutchery Road Venus More Siliguri
Construction of proposed Nursing Training School G.N.M at Alipurduar District Hospital S.I.T.C of 2x1000 KVA Substation and Lightning Protection System
2021_WBPWD_341889_1
WBPWD/SENBEC/NIT-33/2021-2022
Open Tender
ELECTRICAL WORKS ORG
Item Rate
120 days
NTS at Alipurduar District Hospital
Please refer Tender documents.
5 documents required · 5 mandatory
₹2.6 L
Siliguri
24 Jan 2022
27 Aug 2021
27 Sept 2021
27 Aug 2021
24 Sept 2021
10 Sept 2021
8 Sept 2021
Amount
SUB-HEAD -1 ----SITC 11KV VCB PANEL & 11KV / 415V, DRY TYPE TRANSFORMER
Supply & Delivery Indoor-type, floor mounted,metal clad, single tier, fully compartmentalized,free standing, 11 kV VCB Panel with 3 Nos VCBs (1 Incomer + 2 Outgoing), totally enclosed and fully interlocked , horizontal drawout, horizontal / vertical isolation type breaker as per IS 13118, as ammended upto date and as per detail specification attached ( uploaded in the specification section) , suitable for use on 11 KV, 3 Phase,50 Hz AC supply to energise two nos 1000 KVA Dry Type Transformers.
Installation & commissioning of the above 11 kV VCB Panel with P.T & all the accessories, incl. carriage, by placing in position, assembling, lining up, levelling and checking all instruments, relays, correctly set according to requirement.
Supply & Delivery of Cast Resin Dry Type 11KV/415V, 1000 KVA, 3 Phase, 50Hz, Dyn 11, copper wound, Calss F insulation associated with winding temparature indicator/controller, having cable end box in the HV & LV sides and all accessories and confirfing to IS 1117-1985 & IS - 2026 with latest modification (if any) & CBIP Specification and as per detail specification attached (Uploaded in the Specification section). [Make: ABB / Voltamp (Varoda)/CGL].
Installation & commissioning of 11 KV/ 415 volt,1000 KVA distribution transformer incl. carriage to the substation building within a lead of 30mtr by placing in position and fixing after leveling fitting all components, connecting, checking & set of all instrument, relays according to requirement as instructed by the EIC incl. S&F base channels etc.
Making testing arrangement and submitting the test report for high voltage testing of specified voltage incl. checking & testing of all HT / LT equipments by authorized firm of Directorate of Electricity & commissioning the installation after obtaining the Approval of Directorate of Electricity.The scope shall be also included the necessary approval from Authority also.
Supply & fixing 75x45 mm "C" channel having length of 2 mtr. each channel incl. nuts, bolts and washer etc.
Submission of a Sub-station drawing (Computer autocad generated & printed in all sheet quarduplicate)showing H.T & LT cable duct single line power diagrams EI layout system equiment neutral earthing etc. enter plan as per direction and satisfication of E.IC.
Supply & Drawing 1.1 KV Grade 7 Core 1.5 sq.mm PVC Armoured Copper Cable from Transformer WT relay to VCB WT relay for Power & Control Supply as per direction of EIC
SITC OF LT MAIL PANEL IN THE SUBSTATION
SITC of floor mounted Indoor type extensible cubical MV switchboard suitable for use in 3rd party SCADA compatible earthernet network , fabricated by CPRI approved panel maker having compartmentalized design, fabricated out of 14 SWG ( 2.0 mm ) nominal thickness CRCA sheet steel,front and back openable, hinged, single shuttered, with incoming ACBs & Outgoing ACB/MCBS/SFU and all accessories as per size, design & drawing to be approved by EIC and conforming to IS with latest modification and as per detail specification attached ( As in the specification section) [ I/C : ACB 1600A(min-65KA)-2 nos, B/C - ACB 1600A(min-65KA) , O/G SEC-1 : 500A MCCB, 36 kA - 4 nos, 400A MCCB 36kA-4 nos, 250 A MCCB 36kA- 4 nos, 125A MCCB 36 KA -3Nos. , 63A MCCB 25KA - 2 nos.
Supply & delivery, Installation, Testing & Commissioning of AUTOMATIC POWER FACTOR CORRECTION PANEL (150 KVAR) and conforming to IS with latest modification and as per detail specification attached ( uploaded in the specification section) to be installed at HT Substation Building.
SUB HEAD -2 - HT/LT CABLING IN SUBSTATION
Supplying and laying of 1 No. 11KV (E/UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable confirming to IS 7098, of earthed system of following size in the existing Masonary Open Duct as required.[ From Supplier HT Gear to Consumer HT Gear and to Transformer]. [ Make : Nicco / Gloster ]
a) 3 Core x 240 Sq.mm
Making heatshrinkable joints to the ends of the following XLPE HT cable at the transformer end as well as at the VCB ends supplying with necy. jointing kits, sockets, sleeves, anti-corrossive paste, wires, solders, jointing compounds, rubber sheets etc. incl. supplying of necy. tools & tackeles for crimping the end sockets, soldering irons & making of glands at the both end of the cable as per directions of EIC
a) 3 Core x 240 Sq.mm
Supply & Delivery of 1.1 KV Grade XLPE/PVC insulated. PVC sheathed, steel Armoured Al. conductor Cable of the following size, and conforming to IS: 7098 (Part-I):1988/1554 (Part-I): 1988 / 5831:1984 / 3961 (Part-I) :1967 / 3975: 1970 / 10810 : 1984 / 3975: 1970 / 8130:1984 / 3961 :196710418:1982 / 10810: 1984 as amended upto date, in respect of component materials and tests, and as per the approved makes list attached herewith: [Nicco / Gloster / Polycab / Havells / RR Kabel / Crystal]
(a) 4 Core 400 Sq.mm [from Transformer to Main Panel]
(b) 2x4 Core 120 Sq. mm SUBSTATION TO BUILDING ]
(C )4 Core 70 Sq. mm [ LT PANEL TO All type VTPN, LIFT MAIN PANEL TO LIFT PANEL AT MACHINE ROOM ]
Laying of cable as below, after cutting floor pavement / wall / and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish including removing the rubbish
Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor / pavement / wall etc.
Laying of cable above 3½ core 50 sqmm and upto 3½ core 95 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting.
Laying of 2 nos No. cable upto 240 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of one cable above 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4Core 70 Sq. mm
4Core 120 Sq. mm
4 Core 400 Sq. mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
4Core 70 Sq. mm
4Core 120 Sq. mm
4 Core 400 Sq. mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
80mm dia
100mm dia
SUB HEAD - 3 - SAFETY EQUIPMENT
Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscription in signal red colour on front side as required.
a) High Voltage - size 250mm x 200mm
b) Medium Voltage - size 200mm x 150mm
Providing and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS 15222-2002 and cylinders fully charged of following capacity (4.5 Kg ) [Make - Fire Shield / Ceasefire]
Supply and fixing of foam fire extinguishers conforming to IS 4989-2006, Portable type 9 lit capacity hanged on wall with bracket complete as required. [Make - Fire Shield / Ceasefire]
Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required (approx. Front area 1.20 sq.mt.)
Providing of set of 4 nos. 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint 'FIRE' and mounted on MS angle iron frame with bracket and suitable base of appropriate size & capacity I/c filling sand etc.
Providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 13115-1991.
Supply and fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as reqd. (approximate front area 1.20 sq.metre).
Providing of rubber mat 2 mtrs Length x 1 m. wide and 12mm thick to withstand 15 KV dielectric strength as per IS 15652-2006.
Providing of rubber mat 2 mtrs Length x 1 m. wide and 6mm thick to with stand 3.3 KV dielectric strength as per IS 15652-2006.
S&F 11kv grade Rubber Hand Gloves.
S/F of 860 mm wide and 8 mm thick M.S checker plate including painting for covering the trench.
SUB-HEAD -4- EARTHING
S& laying 240 sq. mm. single core multistrand PVC insulated flexible Cu wire in suitable size of PVC flexible pipe (reinforced) from nutral earth busbar to transformer nutral point as required (for Transformer /Generator neutral earthing) including compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry & Socketing both sides by Cu Socket. [ 4 run x 10 mtrs x 2 set = 80 mtrs]
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level as per detail specification attached ( uploaded in the specification section) [FOR TRANSFORMER NEUTRAL AND DG SET EARTHING]
Excavation of soil for installation of Earth Electrode and filling & ramming.
(a) For Soft Soil
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Supplying & fixing earth busbar of Copper flat 65 mm x 10 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with brass bolts, nuts, washers, spacing insulators etc. as required
Insulating the 65 x 8 mm M.S. flat & 65 x 10 mm Copper flat incl. S&F black heat shrink PVC sleeves etc. The PVC tube sleeve to be inserted on the GI flat and heat shrinked by heating apparatus by skilled technician carefully without damaging the PVC sleeve as per direction of the EIC
Supply & fixing 75x45 mm "C" channel having length of 2 mtr. each channel incl. nuts, bolts and washer etc.
S & F special type earth electrode clamp made of GI flat with nuts, bolts,, washer etc. suitable for 80 mm dia GI pipe earth.
SUB-HEAD -5 LIGHTNING CONDUCTOR
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet / Roof / Wall with GI Saddles1100 mm apart incl. mending good the damages to building works
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart including mending good damages to building work
Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint
Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:
(a) Length upto 0.5 Mtr
(b) Length above 0.5 Mtr
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS [ For Soft Soil ]
Earthing with 50 mm dia GI pipe ( Tata Medium ) 3.64 mm thick x 3.04 Mts long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate / pipe electrode .
Terms and condition
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
ELECTROCRAFT
CHAKRABORTY ENTERPRISE
PARTHA SARKAR
M/S N. C. HORE
JADOB ELECTRIC CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .