Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 CrAccepted-AOC | ₹3.6 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹3.7 Cr+₹6.2 L (1.71%)Rejected-Finance BAKRON KA WADA NEAR NEELAM CINEMA JODHPUR ROAD BALOTRA BARMER RAJASTHAN 344022 | BALOTRA | BARMER | RAJASTHAN | 344022 | ₹3.7 Cr+₹6.2 L (1.71%) | L2 | Rejected-Finance REJECTED SINCE NOT L1 |
| 3 | L3₹4.5 Cr+₹93.5 L (26.0%)Rejected-Finance L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | ₹4.5 Cr+₹93.5 L (26.0%) | L3 | Rejected-Finance REJECTED SINCE NOT L1 |
Tender Value
₹3.5 Cr
EMD Value
₹4.2 L
Closing Date
26 May 2020, 6:00 pmClosed
CE (AF) ALLAHABAD
HQ CE (AF) ALLAHABAD
PROVISION OF ALL WEATHER GROUND RUN POINT AT AF STN GORAKHPUR
2019_MES_280338_4
958975/E8
Open Tender
Civil Works
Lump-sum
540 days
GE AF GORAKHPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
Yes
GE AF GORAKHPUR
₹4.2 L
Yes
16 Jun 2020
27 Apr 2020
1 Jun 2020
27 Apr 2020
26 May 2020
12 May 2020
Amount
SCHEDULE A PART I (BUILDING WORKS)
Provision of blast deflector (01 No ) and mooring ring (03 Nos )complete all as specified and as shown in drawings.
Sch A Part II (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION as listed in Sch ‘A’ Part- II .
Sch A Part III (EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION, as listed in Sch ‘A’ Part- III.
Sch A Part IV (AREA DRAINAGE)
Lump sum price worked out by the contractor for AREA DRAINAGE, as listed in Sch ‘A’ Part- IV.
Sch A Part V SITE CLEARANCE, EXCAVATION AND EARTH WORK
Lump sum price worked out by the contractor for SITE CLEARANCE, EXCAVATION AND EARTH WORK, as listed in Sch ‘A’ Part- V.
Sch A Part VI (Miscellaneous Items of B/R and E/M)
Design, fabrication , supply and erecting, Pre-engineered building steel structure for provision of Aircraft shelter of size 30.00 X 25.00 X 10.0 M (clear height) using Galvalume or Zincalume profiled colour coated steel sheet 0.60mm total thickness (with coating and priming) as in roofing all as specified , including foundation with RCC (M-30 design mix) on existing tarmac and excavation and earth work with the following design parameters all as specified and vetted design and drawing by any IIT and approved by Accepting officer with permanent specification complete all as specified and as shown on drawings. :- (i) Frame type - Pre Engineered Building (ii) Size - 30.00 X 25.00 X 10.0 M (clear height at eves level) (iii) Gutter and rain spouts :- 0.5 M width valley gutter made out of curved 2 mm thick GI sheet for full length of shelter including necessary down pipes of UPVC of dia 160 mm. (iv) Painting : All built up frame / HR section, Purlins / gifts/ Bracing / Rafter shall be painted with camouflage pattern, paint of user approved choice. (v) Foundation : The foundation work etc shall be M30 design mix concrete alongwith earth work. (vi) Bird proofing will be of 0.5 mm. Bird proofing should be rivetted to obviate potential FOD damage. (vii) Anti corrison treatment and painting as per IS 1477 Part 1 & 2
M&L for 200 mm compacted thickness granular sub base (GSB) using graded stone aggregate 40mm to 63mm size intertices filled laid in two uniform layers of 100 mm spread thickness each layer compacted, watered, rolled and consolidated to a true surface to required gradient and camber as required by using 8 to 12 tonne vibratory roller to achieve desired density complete all as specified and directed. Note:- Quoted rate shall be for 200 mm compacted thickness.
M&L for 200mm thick (compacted thickness) WMM laid in 2 layers of 100 mm thick (compacted thickness ) each layer, spread, rolled and consolidated to gradient and camber as required including necessary lateral support and form work, if required using crushed stone aggregate of maximum size 40mm of grading as specified type igneous rock such as granite/trap/basalt etc complete all as specified and directed. Note:- Quoted rate shall be for 200 mm compacted thickness.
M&L for 150 mm thick dry lean concrete (DLC) with 7 days compressive strength as 10 N/Sqmm with minimum cement (OPC) content 250 Kg / Cum of concrete including form work if required and rolling complete to achieve desired density and strength complete all as specified and directed. Note: In case of increase in cement content as per design mix formula, nothing extra shall be admissible and quoted rates are deemed to include for the same.
M&L for 10 mm thick layer of sand including rolling over DLC complete all as specified and directed.
M&L for 400 micron polythene film sheet as per IS: 2508 over sand layer complete all as specified and directed. Note:-(i) Side lap of 150 mm and end lap of 300 mm shall be provided wherever required. The rate quoted shall be deemed included for the laps. (ii) Clear flat area after providing sheet shall be considered for payment purpose and nothing extra shall be allowed for laps.
M&L for 300 mm thick pavement quality concrete (PQC) as per design mix using crushed stone aggregate having minimum field flexural strength of 45 Kg/Sq cm in pavement using with and including non circular/triangular synthetic fibre as per manufacturer’s instructions @0.25 % by weight of cement ( min cement content shall be 400 Kg / cum using OPC) laid to level, gradient and camber, spread. paved, campacted & finished using fixed form paver including necessary form work & brooming complete all as specified and directed. Note: (i) In case of increase in cement content as per design mix formula, nothing extra shall be admissible on this account. (ii) Non circular / triangle fibre to be measured and paid separately. (iii) 04 Nos metallic chock plate will be provided by User & to be fixed by the contractor. (iv) Rates quoted by contractor will be deemed to include the above aspects.
M&L for forming 25 mm wide expansion joints to full depth of pavement concrete slab as per shape and section shown on drawing (depth of slab 300 mm) and primed and filled with compressible closed cell premoulded high performance joint filler board HD-100 (Sil Flex Dura board HD 100 of Supreme make or equivalent of Elcon or any other make as approved by E in C' Branch ) and provision of closed cell polyethylene back up rod 30 mm dia , and top 10 mm primed and sealed with and using polyurethane based sealing compound (Polyurethane joint sealant) with suitable primer as per manufacturer's recommendation complete all as shown on drawing and specified and as directed with minimum MAF± 30 % (with ten years performance guarantee ) and applying masking tape on edges of joint to prevent accidental spillage of sealent and removing the masking tape after sealent is applied by mechanical means complete all as specified and shown on drawing including cutting edge of existing pavements for forming expansion joints between existing and proposed slab, if required . Note : (i) Expansion joints shall be provided at spacing not exceeding 36 m as directed by GE. The expansion joint s shall be cut to full depth and shall be formed as described here in above at locations directed by GE, if the slabs are casted for longer lengths. The cost of full depth cuttting as required for forming expansion joints at such locations shall also be deemed included in the contractor's quoted rate for above item. (ii) Filling of joints shall be done by a mechanized system. (iii) Cost of Compressible filler board shall be deemed to be included in this rate.
M & L for forming contration/dummy joint cutting with diamond cutter to a depth of 95 mm and 8 mm wide , primed and providing a 10 mm dia polyethylene back up rod and top 13 mm primed and sealed with and using polyurethane based sealing compound ( polyurethane joint sealant) with suitable primer as per manufacturer's recommendations including minimum MAF ± 30 % (with ten years performance guarantee ) and applying masking tape on edges of joint to prevent accidental spillage of sealant and removing the masking tape after sealant is applied complete all as specified and directed and shown on drawing.
M & L for forming construction joint 25mm deep and 10 mm wide (using diamond cutter ), primed and providing a 12mm dia polystyrene back up rod/debonding strip and top 13mm primed and sealed and using polyurethane based sealing compound and primer of specified make as per manufacturer's recommendation complete all as specified and shown on drawing.
M & L for preparation of surfaces and applying two coats of road marking paint, water based, of approved colour, on surfaces of concrete pavement / roads exc 10 cm wide and painting lines,centre line marking,edge marking,threshold marking, dashes,arrows letters etc for runways,aprons,taxiways etc in such a way that lower surface texture is not visible complete all as specified and directed.
Supply only Polyester non circular/triangular synthetic fibres 0.25% by weight of cement ,6/12mm long with circum circle diametre 30-35 micron, designed for melting point of 240-260 degree Centigrade and having specific gravity of 1.34 to 1.40 complete all as specified and as directed.
Demolition of plain cement concrete (unreinforced) of any mix / grade of ground floor and paving not exceeding 30 cm thickness (below or above ground level) including removal of debris to a distance exc. 1.5 Km but n.exc. 5 Km complete all as specified & directed .
S&F Sub main wiring using two runs of single core PVC insulated, unsheathed stranded copper conductor cable of size 2 x 6 .0 Sq.mm of voltage rating 1100V & drawn in and including concealed PVC conduit of dia not less than 20mm with standard accessories, alongwith one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 1 x 6.0 Sq.mm as earth continuity conductor complete all as specified and directed. Note-Two runs of single core PVC cable 6.0 Sq.mm with one run of 6.0 Sq.mm as earth wire conductor and conduit shall be measured as one unit.
S&F Sub main wiring using two runs of single core PVC insulated, unsheathed stranded copper conductor cable of size 2 x 4 .0 Sq.mm of voltage rating 1100V & drawn in and including concealed PVC conduit of dia not less than 20mm with standard accessories, alongwith one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 1 x 4.0 Sq.mm as earth continuity conductor complete all as specified and directed. Note-Two runs of single core PVC cable 4.0 Sq.mm with one run of 4.0 Sq.mm as earth wire conductor and conduit shall be measured as one unit.
S&F Sub main wiring using two runs of single core PVC insulated, unsheathed stranded copper conductor cable of size 2 x 2.5 Sq.mm of voltage rating 1100V & drawn in and including concealed PVC conduit of dia not less than 20mm with standard accessories, alongwith one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 1 x 2.5 Sq.mm as earth continuity conductor complete all as specified and directed. Note-Two runs of single core PVC cable 2.5 Sq.mm with one run of 2.5 Sq.mm as earth wire conductor and conduit shall be measured as one unit.
S & F factory made epoxy powder coated Distribution Board double door TPN 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts suitable for one FP- MCCB incommer and MCBs as outgoing complete all as specified and directed.
S&F MCB SPN 32 – 40 Amps, 240 Volts C curve 10 KA, complete all as specified & directed .
S&F MCB SP 5 – 30 Amps, 240 Volts C curve 10 KA, complete all as specified & directed
S&F MCCB, 4 pole , 40 Amps, 16 KA curent rating with adjustable thermal and magnetting setting confirming to IEC- 609472 & IS- 139473 to be fixed in distribution board complete all as specified.
S&F MCCB, 4 pole , 32 Amps, 16 KA curent rating with adjustable thermal and magnetting setting confirming to IEC- 609472 & IS- 139473 to be fixed in distribution board complete all as specified.
S&F flood light with new generation energy saving and environmental friendly long life, exclusive innovative die- cast aluminium IP-65 luminaire with high power LED as light source with toughened glass complete of capacity 150 watts fixed properly on steel column with provisional of MS clamps made out of 50X6 mm flat iron and two Nos bolts with nuts etc complete all as specified & directed.
S&F integral LED aviation light fitting luminaries suitable for 230 volts, single phase, 50 Hz supply complete with aluminium housing with polycorbonate enclosures body, with 302 LED, LED 10 watt provided in single fitting complete all as specified & directed. Make:- BGAV 302 LED or equivalent in Havells/Philips/CG
S&F energy saving environment friendly and robust open type vertical highbay LED luminaire with high power COB LED of capacity 150 watt hang properly at directed location/ height and testing complete all as specified & directed.
M&L for Earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15mm bore medium grade protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre. 2. Earth filling shall be done by vegetable soil. 3. Soil should be free from stone, boulders, aggregate, gravels etc.
M & L earthing complete with GI electrode 600x600x6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 2.50 mtr below normal ground level connected to GI strip 32 mm x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of brass connected all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing medium grade and necessary fitting for protection of GI strip including laying of charcoal, dust and common salt PCC (1:3:6) type C-I (using 20 mm graded crushed stone aggregate) earth pit with 40 mm x40 mm x 6mm mild steel angle iron frameincluding 40 mm thick pre-cast RCC cover (1:2:4) type B-1( using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 20mm dia round bar , plastering 15mm thick CM (1:6:) internally and upto 150mm below ground level externally, funnel with wire mesh 20mm dia GI pipe light grade for watering complete all as shown on electrical plate No.3 of SSR Part- 1( 2009) and connected in earth test including testing completed all specified and directed.NOTE :- (i) The rates quoted shall also deemed to include the cost of Earth test point and earth strip and protection pipe upto 7.5 meter beyond the earth plates electrode and the earth resistance of the whole system shall be as near as possible to 0 but shall not in any case exced one ohm. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed / permitted.
Supply and fixing Air termination, single pointed Aluminium rod 12 mm dia and 300 mm long, single pointed at top and mounted on GI pipe with two numbers of MS clamp of suitable size and connecting up with Aluminium strip complete with clamps and all accessories complete all as specified and directed
Supply and Fixing of aluminium Strip Size 25 x 3 mm with saddles and fixing screws for roof conductors and down conductors above ground fixed to roof by means of stand-of hold fast placed and fixed to wall / parapet on insulated saddles complete all as prescribed and all as directed.
Supply and Fixing of test point terminal block made of gun metal or phosphorous bronze 75x75x25 mm of 6 mm thickness 100 mm long drilled and screwed including 3 Nos 8 mm dia 25mm long hexagonal head brass screws including box of size 90 X 90 x 90 mm made of 1.6 plain sheet painted with two coat of SE paint over a coat of red oxide primer and screwed to wall for protection of test point complete all as specified and directed
S&F for galvanised steel water tubing light grade 40 mm bore for fixing up the air termination rod complete all as specified and directed
S&F GI strip 32 x 6 mm burried in groung complete all as specified & directed.
S&F high density polyethylene pipes (HDPE) of pressure rating 6 Kgf / Sqcm and of size 40 mm dia laid in trenches / PCC hard standing complete all as specified & directed.
Supply, installation, commissioning and testing LT feeder pillar box CPRI approved oytdoor type made out of mild steel CRCA sheet of 3.15 mm thick of suitable size with angle iron frame of size 40 X 40 X 6 mm with canopy top, two side ventilators, front openable hinged double door shutters with locking arrangement (including lock and key), weather & vermin proof suitable for working on 440 volts AC supply including bus bar chamber and aluminium bus bar of suitable size - 04 Nos mounted on hygroscopic insulators fixed in separate bus bar chamber and separate compartment for incoming and outgoing feeder, all pre wired with suitable sizeof copper conductor cable including painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer on out side surface and two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer on internal surface and providing necessary foundation / plateform of the LT panel with PCC 1:2:4 type B2 including provision of lugs and cable gland for housing with the following fitment accessories:- Incoming (a) MCCB 4 pole , 100 amps, 415 volt of volt of braking capacity not less than 16 KA - 01 No. (b) Digital ammeter composite type with CT, 0-100 Amps -01 No. (c) Indiactor lamp LED type set of three - 01 No. (d) Digital voltmetre composite type with CT, 0-440 Volts - 01 No. Outgoing (a) MCCB 4 pole, 63 Amps, 415 Volts of breaking capacity not less than 16 KA - 02 Nos (Spare - 01 No) (b) Isolator double pole 32 Amps 240 Volt - 02 Nos (Spare - 01 No)
Boring of holes under road, pavements hard standing by trenchless technology using ultra sound technique with necessary machine not harming the road section including drawing inside HDPE pipe of 150 mm dia of suitable length for 10 Kgf / Sqcm working pressure complete all as specified & directed.
Supply, installing, commissioning and testing complete of manufacturer or OEM (Original equipment Manufacturer) manufatured and tested silent static Diesel Engine driven generating set capable of delivering 35 KVA continuous rating, 10% overload for 1 hour in 12 hours of operation, 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and shall comprises of the following :- (i) Engine (prime mover) : Diesel engine 1500 RPM, 56 BHP, fluid cooled, turbo changed, volts electric 01 number maintenance free batteries, complete with fly wheel and vibration damper, radiator and all standard fittings/fixtures as per standard manufacturing design practices and including suitable instrument panel with RPM meter, lubricant oil temperature & pressure gauge, water temperature gauge and freqency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT & LLOP alarm and shut down safeties.
(ii) Alternator : AC alternator, brushless, 415V, AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 35 KVA, PF 0.8, 1500 RPM, insulation class 'H' enclosure SPDP (IP 23), self excited & self regulated with AVR for +1% voltage regulation, coupled directly/suitably to and to match the above engine. (iii) Base plate : Made out of structural steel as per manufacturer's recommended design/specifications. (iv) Fuel tank : Fuel tank shall be of 24 hours capacity, made of 14 Gauge CRCA MS sheet, duly powder coated and provided with level indicator, draining plug, air vent float, gauge and fuel float switch. (v) Safeties : for high enclosures temperature and emergency shut-down from outside. 01 number, 150 AH, 12V lead acid batteries and adequate size copper conductor cable leads. (vi) Engine control panel : Made of 14 gauge CRCA MS sheet, dust and vermin proof, (protection class IP 41 or superior), duly fitted with the equipment/ metres specified in particular specifications. (vii) Automatic mains failure (AMF) control panel fabricated from minimum 14 gauge CRCA steel sheet (including CPRI type certified), dust & vermin proof, protection class IP -54 suitable for 35 KVA, 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with single phase protection including adequate layers of powder coating floor mounting type with front opening, & panel shall comprises of all necessary accessories as per design by Manufacturer or OEM. (viii) Platform/Plinth/Base shall be provided as per manufacturers recommendations. Cost of the same shall deemed to be included in this item of work.
(ix) Tool kit : Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. (x) Protection : Over load relay, Earth fault Relay, Under Volt release – 01 No each Make of Engine : Cummins/ Kirloskar/Crompton Greaves, Make of Alternator : Kirloskar/ Stamford/ Greaves Crompton.
Disconnecting the cable connection including control panel for high mast and taking down carefully the existing serviceable high Mast light fitting (Set of 9 fittings) with High Mast pole of 12 Metre from their PCC plateform & foundation and mounting, fixing & erecting vertically to another location n.exc. the distance of 500 mtr from existing location alongwith control panel including connecting, testing of high mast light fitting & control panel complete all as specified & directed including consisting the following works:- (a) Excavation in trenches not exceeding 1.5 mtr wide & 1.57 mtr deep for pole foundation & getting out in soft/loose soil, returning filling in the excavated of soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 mtrs complete all as specified and directed. (b) M&L for PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) in foundation of size 2000mmx2000mm and depth 3000mm below ground leveland 500 mm above ground level for encasing the pole complete all as specified and directed (c) M&L for rendering in CM(1:4) on external surface of plateform and painting with 2 coat of SE paint over a coat of primer on control panel. (d) Necessary grouting of pipe for passing the cable etc all as specified & directed. (Note:- Cost of all minor & greasing of cable / motor / rope & transportation charges from existing location to another location are deemed to be included in the quoted rate. Contractor are required to quote their rate accordingly.
M&L for taking out of old existing MES cables of size upto 95 Sqmm 3.5 core, 1100 Volts grade, LT armoured (bunch of 02 runs of any sizes), from directed location and to be shifted to another directed location . Note:- Required earth work shall be measured under respective item of Schedule 'A' Part- V
Material and labour for chemical earthing complete with copper plate electrode 900mm X 600mm X 5 mm buried directly in ground vertically to a depth not less than 4.5 meter below normal ground level (with top edge of earth plate not less than 4.50 meter below ground level) size of earth pits not less than 1.60 x 1.60mtr connected to copper strip 50 mm x 5 mm as main earthing lead by means of tinned copper / brass bolts, nuts, check nuts and washers besides brazing at all joints all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to test point, adequate quantity of charcoal dust (200 Kg), MgSo4 (200 Kg) and common salt (250 Kg) in six alternate layer 100 mm thick around earth plate ,the bottom of earth plate before laying two alternate layer of salt & charcole shall be filled with compacted earth upto deapth of 600 mm & bottom of plate shall be at 900 mm from the bottom of excavation pit & 80 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 25mm dia light grade for watering pipe, funnel & wire mesh including necessary earth work and PCC (1:3:6) type C-1 (using 40mm graded black trap/granite/Basalt stone aggregate) for earth pit and 40mm thick precast RCC cover in 1:2:4 type B1 with 03 Nos 8 mm dia MS bars both ways and the pit will be painted with red colour paint complete all as specified and directed. Note : Earth continutiy conductor upto 7.5 M included in unit rate.
Supply/fixing/installation of Frequency convertor suitable for output of 115 Volts AC, 400 Hz frequency, single phase 20 Amps complete all as specified & directed. Make:- R&E Electronics, Uniline
Supply/fixing/installation of Frequency convertor suitable for output of 36 Volts AC, 400 Hz frequency, three phase, 20 Amps complete all as specified & directed. Make:- R&E Electronics, Uniline
Supply/fixing/installation of Rectifier unit suitable for output of 27 Volts DC, 20 Amps complete all as specified & directed. MAKE :- UNILINE/APLAB/ULTRON ELECTRONICS
Supply & fixing earthing lead 32X6 mm copper strip, laid in trench, fixed on walls with insulators or any other directed position including jointing by tinned copper /brass nuts, bolts and washer in addition to brazing at every joint, making hole - 01 No, 10 mm dia in every 2 mtr length of strip with its brass nuts, bolts, wshers complete all as specified & directed.
Supply & fix PVC conduit pipe ISI marked of size 25 mm dia, 2mm thick with all fittings/accessories/fixing/mounting arrangements such as tees, bends, elbows, saddles, clamps, screws etc all as reqd and directed at site. (For passing of CCTV cables).
Removal and re-installation and testing complete of all accessories of MAFI OFC and taxi light comprising to following complete all as directed :- (a) Trenching for laying conduits 350 mm X 650 mm depth = 60 Mtr (b) Dismantling and removal of ELEVATED TAXI WAY LIGHTS Make : AmA = 03 Nos (c) Removal of 45 W isolation transformer Make : AFLA , EMSTO = 03 Nos (d) Dismantling and removal of primary cable from the ducts = 60 Mtr (e) Dismantling and removal of TH box = 03 Nos. (f) Trench 750 mm X 350 mm (approx 600 mtr length considered ) = 158 Cum (g) OTDR (Note:- (i) Accessories required for this job shall be measured and paid separately under Srl item No. 1.58 to 1.66 ) (ii) The work under item No. 1.57 and fixing of accessories as per Srl item No. 1.58 to 1.66 shall be carriedout by M/S Tata Power (SED) under supervision of MES & Indian Air Force authorities.
(A) AFLS :- Supply only AFLS primary cable single core 5 KV 6 Sqmm complete & directed Make- NAXON
Supply only connector kit for 1C x 6 Sqmm Cable. Make- KD 5106 complete & directed.
Supply only conduit for cable 32 mm complete complete & directed.
Supply only G.I. wire 85 WG complete. Make:- ISI Std
(B) NETWORKING:- Supply only HDPE duct 40 mm complete. Make:- Duraline Sili core
Supply only route marker complete. Make- Cemenled
Supply only precast cement concrete manhole chamber 800 mm diameter and 1000 mm depth.
Supply only multi tube 48 core OFC AKSH - 6F- SM - G652 complete. Make:- AKSH - 6F- SM - G652D
Supply only 48 core splice enclosure complete. Make- Stil
Brahma Infra
NSC Projects Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .