Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹19.5 L+₹14,729.80 (0.76%)Rejected-AOC 21 NEAR LAL KOTHI CHANDER NAGAR SAHARANPUR UP 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L2 | Rejected-AOC Rejected being not L1 | |
| 3 | L3₹19.9 L+₹55,808.60 (2.89%)Rejected-AOC 93 BAPUJI NAGAR ITC ROAD SAHARANPUR 247001 UP | SAHARANPUR | UTTAR PRADESH | 247001 | L3 | Rejected-AOC Rejected being not L1 | |
| 4 | L4₹19.9 L+₹62,028.60 (3.21%)Rejected-AOC | L4 | Rejected-AOC Rejected being not L1 | |
| 5 | L5₹21.0 L+₹1.7 L (8.63%)Rejected-AOC | L5 | Rejected-AOC Rejected being not L1 |
Tender Value
₹28.3 L
EMD Value
₹56,600
Closing Date
9 Aug 2021, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Military Engineer Services Roorkee
SPECIAL REPAIR TO PLASTERING FLOORING ROOF DOORS WINDOWS AND FEEDING MANGERS INTERLOCKING TILES IN PATHWAY AND ELECTRIC POINTS IN SURGICAL WARD BLDG NO 169 OF RTS AND DEPOT SAHARANPUR PROVN OF WAITING SHED FOR COLLECTION PARTY AT 297 COY ASC SUP ROOR
2021_MES_458608_1
8392/021/E8
Open Tender
Civil Works
Item Rate
180 days
Roorkee
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (MES) Roorkee
₹56,600
Yes
19 Feb 2022
10 Jul 2021
11 Aug 2021
12 Jul 2021
9 Aug 2021
26 Jul 2021
Amount
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed .
Materials and labour, brick work with sub class ‘B’ bricks straight curved on plan exceeding 6 meter mean radius with old size bricks built in CM 1:6 complete all as specified & as directed.
All as per item 2.00 here-in-above but except bricks complete all as directed. Note :- Serviceable bricks obtained from demolition against item no 1.00 here-in-before shall be reused.
Taking down cement or cement lime plaster from brick or stone walls etc including racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed.
M & L for rendering 12mm thick on wall in CM 1:6 on other than fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement including preparation of new plastered surfaces of wall and applying three coats white wash complete all as specified and directed.
M&L Rendering 15 mm thick in CM 1:4 on external fair faces of brick/concrete work surfaces finished even and smooth (without using extra cement) including preparation of new plaster surfaces of wall and applying three coats colour wash complete all as specified and directed.
M & L for rendering 5mm thick in cement mortar 1:3 on ceiling surfaces and finished even and smooth without using extra cement including preparation of new plaster surfaces of ceiling and applying three coats white wash complete all as specified and as directed.
M&L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed.
M&L 50 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in floor etc finished even and smooth without using extra cement complete all as specified.
M&L 100 mm thick PCC 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in floor etc finished even and smooth without using extra cement laid in alternate bays, with spike rolling to surfaces or making impression of expended metal whilst the concrete is green complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in surface channels and drains slightly rounded or chamfered angles and throating, as directed incl finish the surfaces smooth without using extra cement complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L 50 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) in floors, plinth protection and pavings finishing cement concrete surface even and smooth using extra cement including construction joint 10 mm width and 50 mm depth complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in copping, benching of manhole / drain slightly rounded or chamfered angles and throating, as directed incl finish the surfaces smooth without using extra cement complete all as specified and directed.
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel staple etc complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25 mm thick over 20 mm thick cement screed (1:6) base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite polish, including dismantling of old tiles/Kota stone complete all as specified and directed
S&F tubes medium grade 15 mm bore galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed
S&F bib tap ISI marked cast copper alloy with crutch or butterfly handle screwed down high pressure and screwed for iron pipe of 15mm bore complete all as specified and directed.
S&F FRP based Air ventilator with stainless steel MOC fin and internal fittings , Throat Size 21" to 24", Max exhaust capacity 2700CFM double jet sealed ball bearings, all as per manufacturer instruction and complete all as specified and directed. Make :- Dura Plast (Rhino tuff) and equvalent.
Excavating in post holes (or similar holes) each n exc 0.5 cum getting out, retirning, filling in and ramming earth broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to distance n exc 50 m and making good surface complete all as specified and directed.
M& L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass-concrete complete all as specified and directed.
M&L for mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1998 Grade St-240 complete all as specified and directed.
M& L for hardcore of broken stone/boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M& L for 100 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub-floors, sub-bases, floors, complete all as specified and directed
M&L for joint free non skid coloured ceremic tiles 7 to 8 m thick (square/ rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection incl finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for 1.00mm thick 150 mm dia mild steel sheet eaves gutters, galvanised class 3, half round with rounded edges complete all as specified and directed.
M&L for 110mm PVC(SWR) rain water pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed.
M&L for 110 mm PVC(SWR) bends any radius complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-2 (using 40 mm garded stone aggegate) as in foundation filling and mass concrete complete all as specified and directed.
Supply only Plastic dividing strips, 1.5 mm thick and 38 mm wide, inserted in position, conform to design complete all as specified and directed.
M&L for rendering 15mm thick consist of two coats top layer 5 mm thick in CM 1:4 over 10 mm th in CM 1:6, on fair faces of brick work ( WPC shall be measured & paid seperately) finished even & fair all as specified.
M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete incl fixtures and fittings such as switches, ceiling rose, pendant, regulator, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
M & L for concealled Point wiring with PVC insulated PVC unsheathed electric (FRLS) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of pvc conduit surface casing capping will be used) & 1.5 Sqmm green PVC insulated unsheathed copper conductor (FRLS grade) as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes (normal and modular type) of 1.6 mm thick (duly painted with two coats of black bituminous paint over a coat of red oxide primer in and out sides) with and including plastic laminated bakelite sheet cover of hylam board of 2.8 mm thick including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc for the following:-
One light point controlled by one way switch
One fan point controlled by one way switch
One 3/5 pin socket outlet 5 Amp on the same board with other switches.
One 3/5 pin 5 Amps socket outlet on independent board.
All as per item No 38.00 above here in before but wiring in existing conduit for the following :-
One light point controlled by one way switch
One fan point controlled by one way switch and fan regulator
One 3/5 pin 5 Amps socket outlet on independent board, 1.5 sqmm size cable .
All as per item No 38.00 above here in but with 2.5 Sqmm (nominal area) FRLS cable PVC for the 15 Amp 3/5 pin socket power point including 1.5 Sqmm copper conductor green as colour for earth continuity all as specified.
All as per item No 47.00 above here in but in existing conduit with 2.5 Sqmm (nominal area) FR cable PVC for the 15 Amp 3/5 pin socket power point including 1.5 Sqmm copper conductor green as colour for earth continuity all as specified.
M&L for point wiring complete with PVC insulated and unsheathed (FRLS) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with stranded copper conductor single core in and including rigid PVC surface conduit not less than 19 mm dia, clip, with suitable MS terminal boxes (not less than 1.0 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including earth dolly with 3 mm thick plastic laminated sheet top cover of approved colours including 1.50 sqmm green stranded copper conductor (FRLS grade) as continuous earth wire with all accessories including lugs required, complete all as specified and as directed:-
(a) One light point controlled by one switch
(b) One fan point controlled by one switch & regulator.
(c) One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
(d) One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
All as per item No 49.00 above but using 2.5 sqmm single core multi stranded (FRLS)copper conductor PVC insulated and unsheathed flame retardant low smoke (FRLS) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
Taking down sub main wiring and supply and fixing Sub main wiring with two runs of single core PVC insulated and unsheathed multi stranded, copper conductor (FRLS) cable of size 4.0 sqmm LT, 1100V grade, drawn through and incl adequate sizes PVC non metallic conduit of 20mm/appropriate dia with accessories and fittings and one run of 2.5 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm/appropriate dia shall be measured as one run length. Note:- (i) Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. (ii) Earth wire shall run inside the conduit pipe (iii) Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.
S&F switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 15 Amps complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type complete all as specified.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type complete all as specified.
S&F Ceiling rose 3 phase / PVC / polycarbonate, insulated body complete all as specified and directed.
S&F stepped type electronic fan regulator flush type complete all as specified and directed.
S&F Lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings with 9 watt LED bulb PAG series B-22 base complete all as specified and directed.
S&F LED Tube light fitting 1x18/20 Watt surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser & integrated electronic driver complete with all accessories internally prewired and incl connecting up three core single wire complete all as spd and directed. Make : Havells ENDURALINEARNEOBS20WLED830SPCWH or equivalent Phillips Smart Bright cat Part No. BN021CLED20SPSUCWGRS2
Taking down carefully UNSV main switches, DBs including MCBs etc complete of any size and capacity complete all as specified and directed.
S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 415 Volts 200 amps rated busbar 8 way complete all as specified and directed.
S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 415 Volts 200 amps rated busbar 4 way complete all as specified and directed.
S&F for Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar ,triple pole and neutral 415volts, flush to wall complete all as specified and directed.
M&L for MCB single pole,6 to 40 Amp 240 volt B curve 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed.
S&F Miniature circuit breakers ISI marked 240 Volt, 50 Hz, double pole 40 Amps, breaking capacity 10 KA suitable for cable upto 35 sqmm cross sectional area complete including suitable size copper lugs complete all as specified and directed
S&F Miniature circuit breakers ISI marked 240 Volt, triple pole 32 Amps, breaking capacity 16 KA suitable for cable upto 35 sqmm cross sectional area complete including suitable size copper lugs complete all as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interior dimensions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3 of SSR 2009 including testing after completion.
Supply and fix in repairs 1100 volt grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm dia suspension wire, one twin core cable flat or circular of size 6 Sqmm complete all as specified and directed.
Supply and fix in repairs 1100 volt grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm dia suspension wire, one twin core cable flat or circular of size 10 Sqmm complete all as specified and directed.
Dismantling of house service bracket of any type complete all as specified and directed.
Supply and fixing house service bracket (hook type) complete with 3.0 mtrs long GI pipe 40 mm dia medium grade two nos 90 degree bends, MS hook and stay or guy complete all as specified
Taking down ceiling fan of any discription including disconnecting of all electric connections, separating fan body and blades, depositing to store complete all as specified and directed
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed
Supply and fixing in replacement of building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP-65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 25 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete including taking old street light fitting any type and description and removing to store complete all as specified and directed. Make: Havells, Cat Part No ENDURAPEARLSL25WLED757SASYTOPCMP of Havells or equivalent in C&S/Phillips/Crompton/Bajaj/Syska
M&L for MCB single pole and neutral ISI marked 240 Volt, 50 Hz, 63 Amps, breking capacity 10 KA complete including suitable size copper Lugs complete all as specified and directed.
M&L for laying GI tubing light grade 40 mm dia with all fittings on floor, wall or for cable protection on pole including GI clamps nut bolts and washer etc complete all as specified and directed.
S& F in repair bulk head energy saving new generation 10W LED IP65 luminaire with opal diffuser and connecting with copper flexible three core 23/0.0076 and all necessary fixing accessories complete all as specified and directed.
Taking down service bracket with all fitting from wall of any size and making good disturbed surface of wall complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming excavated hard/soft soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested complete all as specified and directed.
Removing excavated surplus materials obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
Material and labour for clean dry sand in trenches/ducts for cushioning to cable, complete all as specified and directed. Note:- Punned depth of sand shall be mesured for payment purpose.
Supply and laying burnt bricks sub class 'B' old size for cable protection laid length wise perpendicular to the axis of cable, complete all as specified and directed.
JBN CONSTRUCTION
G.H. INFRASTRUCTURE PRIVATE LIMITED
M/s Inderlal
M/S IRFAN AHMAD CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .