Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.2 L+₹4.6 L (26.1%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹22.8 L+₹5.2 L (29.4%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹23.1 L+₹5.5 L (31.3%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹48,500
Closing Date
19 Jan 2022, 6:00 pmClosed
GE (AF) Hakimpet
Secunderabad
REPAIRS AND MAINTENANCE OF INTERNAL ELECTRIFICATION SYSTEM AND OTHER ALLIED WORKS AT AF STN BEGUMPET UNDER GE (AF) HAKIMPET
2021_MES_496679_1
8357/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
BEGUMPET
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) HAKIMPET
₹48,500
Yes
22 Feb 2022
22 Dec 2021
22 Jan 2022
22 Dec 2021
19 Jan 2022
5 Jan 2022
Amount
Taking down carefully copper/ aluminium point wiring (light, fan,socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good disturbed surfaces of walls, floors etc. including paint touch up to match with the existing surface complete all as specified and as directed by the Engineer-in-charge.
M&L for Point wiring complete with 1.5 sq mm single core PVC insulated FRLS cable, with multi standard copper conductors, 1100 volts grade, drawn thorough and including double locking type PVC casing and caping and its accessories of suitable size and including provisoin of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, fabricated steel teminal box made out of 1.60 mm thick MS sheet concealed in walls and covered with 3 mm thick hylum sheet for fixing the switches /sockets/ regulators etc.all specified for :- Make: For Copper wire 1100V: Finolex, Havells, L&T, Anchor and For PVC casing caping : Precision, Modi, Presto Plast, Supreme, Polycab, Sudhakar
(a) One light point controlled by one one way switch.
(b) One light point controlled by Two 2-way switch.
(c) One ceiling fan/ exhaut fan point controlled by one one way switch.
(d) One 3 pin socket outlet 5 Amps on the same board with other switches.
(e) One 3 pin 5 Amps socket outlet the switch board of light point in the same vertical plane.
(f) One 3 pin socket outlet 5 Amps on the Independent board.
(g) One bell/ buzzer point controlled by one push button independent.
All as per item No. above here-in-before but with 4.0 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 4 Sq mm copper conductor green in colour as earth continuity conductor complete all as specified and as directed by the Engineer-in-charge. Make: For Copper wire 1100V: Finolex, Havells, L&T, Anchor and For PVC casing caping : Precision, Modi, Presto Plast, Supreme, Polycab, Sudhakar
All as per item No above here-in-before but conductor drawn through stove enamelled steel conduit (Surface) for one light point controlled by one flame proof switch complete all as specified and as directed by the Engineer-in-charge.
Point wiring complete with two runs of 1.5 sq mm single core PVC insulated FRLS cable 1100 volts grade with multi-stranded copper conductors, drawn thorough and including non metallic med grade rigid PVC conduit with all conduit accessories (including concealing and finising to match with the sorroundings) and including provisoin of 1.5 sqmm PVC indulated copper cable FRLS as earth continiuty conductor, fabricated steel teminal box made out of 1.60 mm thick MS sheet concealed in walls and covered with 3 mm thick hylum sheet for fixing the switches /sockets/ regulators etc.all as specified for :- Make: For Copper wire 1100V: Finolex, Havells, L&T, Anchor and For PVC Conduit: Tirupati, Supreme, Prince, Finolex, Dutron
(a) One light point controlled by one way switch.
(b) One light point controlled by 2-way switch.
(c) One ceiling fan/ exhaust fan point controlled by one way switch.
(d) One 3 pin socket outlet 5 Amps on the same board with other switches.
(e) One 3 pin 5 Amps socket outlet the switch board of light point ini the same vertical plane.
(f) One 3 pin socket outlet 5 Amps on the Independent board.
(g) One bell/ buzzer point controlled by one push button independent.
All as per item No. above here-in-before but with 4.0 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor complete all as specified and as directed by the Engineer-in-charge. Make: For Copper wire 1100V: Finolex, Havells, L&T, Anchor and For PVC Conduit: Tirupati, Supreme, Prince, Finolex, Dutron
Supply and fix Switch Piano, flush type single pole, one way 5 Amps. Make:Legrand / Crabtree / Anchor / Havells.
Supply and fix Switch Piano flush type two way 5 Amps. Make:Legrand / Crabtree / Anchor / Havells.
Supply and fix Switch socket combination 2 in 1, 5 Amps flush type. Make:Legrand / Crabtree / Anchor / Havells.
Supply and fix Switch socket combination, 3 pin, 5 and 15A, 5 IN 1 flush type. Make:Legrand / Crabtree / Anchor / Havells.
Supply and fix Switch bell push 5 Amps flush type. Make:Legrand / Crabtree / Anchor / Havells.
Supply and Fixing Stepped type electronic fan regulator flush type. Make:Legrand / Crabtree / Anchor / Havells.
Supply and fixing Ceiling rose PVC/ Polycorbonate insulated body with three terminals.
S&F CMRI Certified LED Flameproof 2X16/20W LED Tube Light fixture and including LED tube-02 Nos reccomended for gas/ vapour group IP 65 Protection with complete fittings and accessories all as specified and directed. Make : Crompton EXTN2LT8-16/20/ Sudhir or equivalent
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V. Make : Sudhir or equivalent.
Point wiring complete with 1.5 sq mm single core PVC insulated FRLS cable, with multi standard copper conductors, 1100 volts grade, drawn thorough and including non metalic, med. grade rigid PVC conduit with all conduit accessories (including concealing and finising to match with the sorroundings) and including provisoin of 1.5 sq mm PVC indulated copper cable FRLS as earth continiuty conductor, fabricated steel teminal box made out MS sheet suitable for Modular switches concealed in walls with front cover & base frame, screws, suitable for housing modular switches, socket outlets, fan regulators etc, all as specified and as directed for the following:- Make: For Copper wire 1100V: Finolex, Havells, L&T, Anchor and For PVC Conduit: Tirupati, Supreme, Prince, Finolex, Dutron
(a) One light point controlled by one way switch .
(b) One ceiling fan/ exhaut fan point controlled by one way switch.
(c) One 3 pin socket outlet 5 Amps on the same board with other switches.
(d) One 3 pin 5 Amps socket outlet the switch board of light point ini the same vertical plane.
(e) One 3 pin socket outlet 5 Amps on the Independent board.
(f) One bell/ buzzer point controlled by one push button independent.
All as per item No- above here-in-before but with 4.0 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor complete all as specified and as directed by the Engineer-in-charge.
Supply and fix Modular switch 6A, 1 way. Make:Legrand / Crabtree / Anchor / Havells.
Supply and fix Modular switch 16A, 1 way. Make:Legrand / Crabtree / Anchor / Havells.
Supply and fix Socket outlet 6A modular. Make:Legrand / Crabtree / Anchor / Havells.
Supply and fix Socket outlet 16A modular. Make:Legrand / Crabtree / Anchor / Havells.
Supply and fix switch bell push modular. Make:Legrand / Crabtree / Anchor / Havells.
Supply and fix Fan Step regulator, 120 W-2 modular.Make:Legrand / Crabtree / Anchor / Havells.
Supply and fix bell, Ding Dong AC, 230 volts, SP. Make:Legrand / Crabtree / Anchor / Havells.
M&L for sub main wiring with 2x4.0 Sq mm and 1x4 Sqmm(Earth), FRLS PVC insulated, unsheathed, multi-stranded, 1100 volts grade copper conductor calbe, single core, drawn through and including double locked type PVC casing & Capping and its all accessories of suitable size on wall/ roof surfaces complete all as specified and as directed by Engineer-in-charge. Note: Three runs 4 Sq mm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length including taking down existing sub main wiring.
All as per item above here-in-before but with 2x6.0 Sq mm and 1x6 Sqmm (Earth) complete all as specified and as directed by Engineer-in-charge. Note: Three runs 6 Sq mm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length.
All as per item above here-in-before but with 4x6.0 Sq mm (3Ph+1N) + 2x 6 Sq mm (Earth) complete all as specified and as directed by Engineer-in-charge. Note: Six runs of 6 Sq mm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length.
All as per item above here-in-before but with 4x10.0 Sq mm (3Ph+1N) + 2x 10 Sq mm (Earth) complete all as specified and as directed by Engineer-in-charge. Note: Six runs of 10 Sq mm copper cable and one run of suitable width of PVC casing and caping shall be measured as one unit length.
Supply and fix in repairs including taking down the following Items:-
(a) Lamp holder PVC/ Polycarbonate type with back plate suitable for batten/ angular type.
(b) Ceiling rose PVC/ Polycorbonate insulated body with three terminals.
(c) Switch Piano, flush type single pole, one way 5 Amps. Make:Legrand / Crabtree / Anchor / Havells.
(d) Switch Piano flush type two way 5 Amps. Make:Legrand / Crabtree / Anchor / Havells.
(e) Switch socket combination 2 in 1, 5 Amps flush type. Make:Legrand / Crabtree / Anchor / Havells.
(f) Switch socket combination, 3 pin, 5 and 15A, 5 IN 1 flush type. Make:Legrand / Crabtree / Anchor / Havells.
(g) Switch bell push 5 Amps flush type. Make:Legrand / Crabtree / Anchor / Havells.
(h) Stepped type electronic fan regulator flush type. Make:Legrand / Crabtree / Anchor / Havells.
(j) Modular switch 6A, 1 way. Make:Legrand / Crabtree / Anchor / Havells.
(k) Modular switch 16A, 1 way. Make:Legrand / Crabtree / Anchor / Havells.
(l) Socket outlet 6A modular. Make:Legrand / Crabtree / Anchor / Havells.
(m) Socket outlet 16A modular. Make:Legrand / Crabtree / Anchor / Havells.
(n) switch bell push modular. Make:Legrand / Crabtree / Anchor / Havells.
(o) Fan Step regulator, 120 W-2 modular.Make:Legrand / Crabtree / Anchor / Havells.
(p) Bell, Ding Dong AC, 230 volts, SP. Make:Legrand / Crabtree / Anchor / Havells.
(q) Surface mounting PVC/Poly carbonate Box suitable for fixing 5A Switch socket over existing wall
(r) Surface mounting PVC/Poly carbonate Box suitable for fixing 15A Switch socket over existing wall
(s) Plug top polycarbonate 3 pin 5 Amps. Make : Legrand/Crabtreet/Anchor/Havells
S&F Surface and wall mounted 9W LED 6K, 600X25x40 (LXWXH) batten, polycarbonate housing & integrated electronic driver ready to use pack etc. complete with all accessories internally pre-wired and fixing and connecting up with twin core twisted flexible copper conductor cable with suitable size upto ceiling rose. Make: Havells Model No: LUMILINEBS9WLED865SPCWH or equivalent in Phillips/ CG.
S&F Surface and wall mounted 20W LED 6K, 1150X25x40 (LXWXH) batten, polycarbonate housing & integrated electronic driver ready to use pack etc. complete with all accessories internally pre-wired and fixing and connecting up with twin core twisted flexible copper conductor cable with suitable size upto ceiling rose. Make: Havells Model No: LUMILINEBS20WLED865SPCWH or equivalent in Phillips/ CG.
M&L for Taking down ceiling fan of any description, sealing cable ends, dismantling blades, cleaning all dust, applying grease, filling cavaties with fillet, painting with synthetic enamel paint by spraying and writing MES No including reassembling blades and hanging ceiling fan and connecting up including provision of cable from ceiling rose to connector of fan all as specified and as directed.
All as per item No. above here-in-before but exhaust fans of any sweep.
All as per item No. above here-in-before but wall mounted fans/ Pedestal fans of any sweep.
Supply and fix in repair gun metal bush suitable for existing wall mounted/ pedestal/ exhasut fans complete all as specified and as directed by the Engineer-in-charge.
Supply and fix in repair capacitor 2.5 MFD suitable for ceiling fan / exhaust fan complete all as specified and as directed by the engineer-in charge.
All as per item No. above but of 4 MFD suitable for ceiling fan / exhaust fan complete all as specified and as directed by the engineer-in charge.
Dismantle the unserviceable shackle assembly comprising GI bolts, nuts, rubber bush and split pin complete all as specified and as directed by the Engineer-in-charge.
Material & labour for removing the defective fan winding and rewinding with super enamelled copper wire of existing gauge, applying insulation varnish, pre heating and binding with empire tubes, crimple sheet etc. as required for rewinding complete all as spedified and as directed by the Engineer-in-charge for the following:- (Note: Cost of transportation/handling from MES Store to workshop & back is deemed to be included)
(a) Ceiling fan of size upto 1400 mm sweep.
(b) Wall mounted/ Pedestal fan of size upto 450 mm sweep.
(c) Exhaust fan of size 350 to 450mm Sweep.
(d) Exhaust fan of size upto 300 mm Sweep.
Supply and fix new louvers suitable for exhaust fans of size upto 450 mm sweep including taking down existing and complete all as specifeid and as directed by the Engr-in-charge.
Taking down the electric Geyser of capacity 25 ltrs/ 50 ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, electrical connections, dismantling the unit, painting with one coat of synthetic enamel paint and refixing in its original position and reconnecting the inlet/ outlet water pipes and testing on completion complete all as specified and as directed by the Engineer-in-charge.
Supply and fixing of following items in repairs, suitable for single phase, 230 Volts, 50 Hz for existing type electric Geyser of capacity 25/50 ltrs:-
(a) Heating element 1500 watts push/ thread type porcelain / Circular / triangular type as required at site.
(b) Thermostat as per the existing type.
(c) Indication lamp red/ green.
(d) Fusible plug
Taking down the electric geyser of capacity 25 Ltrs / 50 ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, dismantling the unit, taking out the inner leaking copper shell, brazing the copper shell, testing for leaks, re-assembling the geyser including provision of additional glasswool as required, refixing in position, testing for functionality and commissioning.
Supply and fix PVC connection 15mm dia 450mm long with brass nuts, and rubber washers on both sides suitable for cold/ hot water including taking down complete all as specified and as directed by the Engineer-in-charge.
M&L in repair for Vertical Distribution board when MCCB Triple Pole upto 250A is used for in coming and MCBs for out going to be used VTPN 8 way, 415 volts, IP 43, busbar , earth bar & neutral link double door complete all as specified and as directed. Note: MCCB and MCB will be measured and paid seperately under relevant items. Make: Havells, HPL, Indo asian
M&L in repair for Vertical Distribution board when MCCB Triple Pole upto 160A is used for in coming and MCBs for out going to be used VTPN 4 way, 415 volts, IP 43, busbar , earth bar & neutral link double door complete all as specified and as directed. Note: MCCB and MCB will be measured and paid seperately under relevant items. Make: Havells, HPL, Indo asian
Supply and fix in repair MCB Distribution board double door type (for incoming MCB & out going MCBs) TPN 8 way vertical type IP 43 with bus bar neutral link & earth bar etc. complete all as specified and as directed by the Engineer-in-charge. Note: MCB will be measured and paid seperately under relevant items. Make: Havells, HPL, Indo asian
Supply and fix in repair Distribution Board's when MCBs to be used 240V, double door of size neutral link & earth bar etc. complete all as specified and as directed by the Engineer-in charge. Note: MCB will be measured and paid seperately under relevant items. Make: Havells, HPL, Indo asian
All as per item above here-in-before but of TPN 4 way with incoming MCBs. Note: MCB will be measured separtely
Supply and fix in repair Single pole & Neutral Metal clad enclosure with a two pin and earth plug and socket including one single pole MCB of 20amps complete all as specified and as directed by the Engineer-in-charge.
Supply & fix in repairs, MCCB 3 pole, 415V, fixed type suitable for Distribution Boards and connecting with terminating cables by using lugs as required complete all as specified and as directed by the Engineer-in-charge.
MCCB TP 200A, 25KA.
MCCB TP 160A, 25KA.
MCCB TP 125A, 16KA.
MCCB TP 63A, 16KA.
Supply and Fix in repairs, MCB ''C'' curve, including provision of copper lugs for cable termination, terminating cables by using lugs as required complete all as specified and as directed by the Engineer-in-charge.
MCB FP 63A, 10KA.
MCB FP 40A, 10KA.
MCB FP 32A, 10KA.
MCB DP 6-32A, 230 volts.
MCB DP 40A, 230 volts.
MCB SP 6-32A, 230 volts.
Supply and connect flexible FR PVC Insulated (unsheathed) single core stranded copper conductor cable of 1100 voltage grade IS 694 of size 1.5 Sqmm including taking down unsv flexible wire .
Supply and fixing 1100 volts gr. heavy duty cable, PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, twin core cable of size 6.0 Sqmm including taking down exisiting service cable . Make : Finolex/Nakoda/Finecab/Universal/Polycab
Supply and fixing, 1100 volts gr. heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, twin core cable of size 10 Sqmm including taking down exisiting service cable. Make : Finolex/Nakoda/Finecab/Universal/Polycab
M&L in repair for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 Mtr below ground with top edge of the earth plate not less than 1.5 mtr below normal ground level, Earth plate shall be connected with double bolts, nuts, check nuts & washers, to & including 32x6 mm galvanized iron strip as earth lead, extended upto 7.5 m or upto test terminal point, drawn through 40mm dia med. gr. GI pipe for protection of galvanized iron strip in the ground, including excavation, earth work, Bentonite 25Kg, Charcoal & Salt all as specified, PCC chamber, RCC cover slab, watering pipe 20mm dia bore med. grade, funnel etc. & testing on completion all as specified in plate No.3 of SSR Pt-I, complete all as specified and as directed. NOTE: a) GI Pipe for protection of earthing strip and earth strip beyond 7.5m shall be measured and paid seperately under relevant items.
S& F multi-sensor (smoke & heat) and Analog addressable type multi-sensor (smoke & heat) detector with dual optic's technology to distinguish and differenciate between real fire, steam and dust to avoid any false alarm with base powder, including other accessories as required including taking down existing unserviceable sensor complete all as specified and directed by Engineer-in-charge. Make: EST-3/Notifire/ Honey well/Ravel.
Supply and replacement of retrofit glass LED tube light, cool white, 20watt, suitable for T8 frame, including modification of wiring to suit LED tube and taking down old one. Make: Havells, Model:CRYSTAL1213T8DSTL20WLED865SGLASS 'OR' equivalent in Phillips/CG/ Instapower.
S & F LED Driver upto 42W suitable for 2'x2', recess mounted, 42W LED light fitting including making good to false ceiling as required at site including taking down the old unserviceable LED driver of any wattage from false ceiling. Make : Havells/Syska/CG/Philips/Bajaj
Supply, Installation, Testing and commissioning of New Addressable Fire Alarm control panel with power supply & battery back up at normal condition and 15 minutes alarm operation with battery charger etc. 2 Zone panel including taking down unserviceable Fire Alarm control panel complete all as specified and directed by Engineer-in-charge. Make: EST-3/Notifire/ Honey well/Ravel.
Supply and fixing of energy efficient, 25W LED light fitting with die cast aluminium housing with high power LEDs as light source and complete accessories, fitted to existing pipe bracket including taking down of unserviceable building security lights of any type, complete all as specified and as directed. Make:Havells / Phillips/CG/Instapower/Bajaj.
Supply and replacing of tamper proof, digital energy meter of Accuracy Class 1.0, AC, 240V, 50Hz, with Backlit LCD Display, of rating 5-30A (Measures & Displays kWh,V,I,kW,PF, Last month history of kWh & MD in kW) with special features like TOD,Tamper logging,Optical Communication Port , including taking down the old meter. Make: L&T Model - WM101BC5DDH 'OR' equivalent in Secure, HPL, AE.
Supply and replacing of tamper proof AC Three Phase Static Energy meter of Accuracy Class 1.0, 3 x 240V, 50Hz, with Backlit LCD Display, of rating 10-60A (Measures & Displays kWh, V,I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like TOD,Tamper logging, Optical Communication Port , including taking down the old meter. Make: HPL, Model:TPPB1521130000ME01 (Gurgaon) 'OR' equivalent in Secure, L&T , AE.
Supply and replacing of TP, 3x240V, 50Hz, CT operated, digital Multi-function Energy meters of accuracy class 0.5 with backlit LCD display. Measures and displays trivector energy, load survey, TOD, Tamper detection & logging, power on / off events, instantaneous parameters of rating -/5A with 160A/5A CT Coil -03 Nos with transperant hinged type box , including taking down the old. Make: L&T 'OR' equivalent in Secure, HPL, AE.
Excavation of three holes of size 15cm x 15cm x 60 cm depth sorrounding the existing earth pit, pouring of common salt (Sodium chloride) 5 Kgs in each hole, refilling the pit with the excavated soil and watering all as specified and as directed for increasing the earth conductivity and decreasing ER values, removing and clearing the surplus soil.
Servicing of solar geyser panel using mild cleaning agent, removing and replacing of rusted nuts and bolts with GI nuts and bolts.
Supply and fix geysor element, 3.0 KW, SP, suitable for Solar water heater backup including taking down the old element.
Supply and fix of geysor element, 2.0 KW, SP, suitable for Solar water heater backup. including taking down the old element.
Disconnecting the electrical, water supply connections of Solar geyser, repairs to leaking Solar geyser inner tank by removing glass wool, cutting/disconnecting the rusted inlet and outlet nipples, supply and connect new nipples of size as existing by brazing/ welding, leak testing, refilling the glass wool including additional glasswool as required, fixing in position, testing and commissioning all as directed by Engineer-in-Charge.
Supply and fix E171, made of EN 304 SS steel sheet of thickness 0.8mm, suitable for flat plate collector along with with stand including taking down unserviceable.
Supply and fixing heavy duty battery 12V 88 AH gen set having polypropylene container with ribs, recharging capability Make : Exide/ Amron/Luminous
Supply and fixing heavy duty battery 12V 150 AH gen set having polypropylene container with ribs, recharging capability Make : Exide/ Amron/Luminous
Supply and fixing heavy duty battery 12V 18 AH gen set having polypropylene container with ribs, recharging capability Make : Exide/ Amron/Luminous
Supply and fix automatic electronic voltage stabilizer, wall mounting type having features such as Intelligent time Delay system, Low and High Voltage Cut-off Protection, latest IC Technology to protect from power fluctuations, Thermal over load protection, wide input variation between 170V to 270V with output voltage stablized at 220 to 240V, with accuracy of +/- 2.5% and of following capacity and remove unserviceable electronic voltage stablizer and hand over to E/M store and complete all as specified and as directed by the Engineer -in -Charge.
(a) 4 KVA Capacity. Make: V-Guard, Model-VG 400 or equivalent
(b) 5 KVA Capacity. Make: V-Guard, Model-VG 500 or equivalent
M/s SHAIK ZAINULABDEEN
Sri Balaji Enterprises
SAI ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .