Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC WARD NO 1 BIJURI MADHYA PRADESH 484 440 | ANUPPUR | MADHYA PRADESH | 484440 | L1 | Accepted-AOC Awarded being valid and eligible L-1 Bidder as per
Tender Committee evaluation. Awarded value is as per
ONLINE Bid Price inclusive of Goods and Service Tax
(GST) Components. | |
| 2 | Rejected-Technical | - | Rejected-Technical NOT OPENED FOR TECHNICAL EVALUATION SINCE NOT BEING L1 BIDDER. HENCE REJECTED. | |
| 3 | Rejected-Technical | - | Rejected-Technical NOT OPENED FOR TECHNICAL EVALUATION SINCE NOT BEING L1 BIDDER. HENCE REJECTED. | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT OPENED FOR TECHNICAL EVALUATION SINCE NOT BEING L1 BIDDER. HENCE REJECTED. |
Tender Value
₹3.0 L
EMD Value
₹3,900
Closing Date
18 Apr 2023, 5:00 pmClosed
STAFF OFFICER (CIVIL), HASDEO AREA, SECL
OFFICE OF THE STAFF OFFICER (CIVIL), HASDEO AREA, GM OFFICE, SOUTH JHAGRAKHAND COLLIERY, DISTT.- MANENDRAGARH- CHIRMIRI-BHARATPUR (C.G.)-497 448. NAME AND MOBILE NUMBER OF CONTACT PERSON SHRI D.K.VISHWAKARMA,7587390016(Phone), 7771243056(Landline)
Modification for Resin Capsule Storage Room inside of Shed No. 6 of Regional Store under Bijuri Sub Area of Hasdeo Area.
2023_SECL_277050_1
GM/HSD/C/e-Tender/23-24/01 Date 06.04.2023
Open Tender
Civil Works - Others
Item Rate
45 days
BIJURI SUB AREA OF HASDEO AREA DISTT.-ANUPPUR (MP)
Please refer Tender Documents.
3 documents required · 3 mandatory
₹3,900
7 Jun 2023
7 Apr 2023
20 Apr 2023
8 Apr 2023
18 Apr 2023
8 Apr 2023
7 Apr 2023 - 13 Apr 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Brick work with Fly ash bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with Fly ash bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Structural steel work in single section, fixed with or without connecting plate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/ self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand and manufacture
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
Total impact of GST for the purpose of CTC
AMBE CONSTRUCTION
UTPAL BHATTACHARYA
LALAN KUMAR AKELA
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_286814.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .