Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC SHOP NO 82 6 TRANSPORT NAGAR NARWAL JAMMU 180004 | JAMMU | JAMMU | J K | 180004 | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.0 L+₹2.6 L (8.30%)Rejected-Finance 110 245 NEHRU NAGAR KANPUR UTTAR PRADESH 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹34.9 L+₹3.4 L (11.0%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹36.4 L+₹4.9 L (15.7%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹36.8 L+₹5.4 L (17.0%)Rejected-Finance JAJJAR KOTLI JAMMU J K 151222 | JAMMU | JAMMU | J K | 151222 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
11 Oct 2022, 6:00 pmClosed
GE (UTILITIES)
GE (UTILITIES) UDHAMPUR, PO-GARHI, PIN-182121
Repair/Replacement/Maintenance of centrifugal pump sets, electric motor, LT panels, DG sets capacity 62.5 KVA to 600 KVA and allied system installed in certain different locations under GE (Utilities) Udhampur.
2022_MES_551714_1
GE/U-49/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (UTILITIES) UDHAMPUR
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (UTILITIES) UDHAMPUR
₹97,000
Yes
9 Dec 2022
13 Sept 2022
13 Oct 2022
13 Sept 2022
11 Oct 2022
27 Sept 2022
Amount
Decoupling, disconnecting suction line and discharge line taking down from foundation, dismounting from base channels strip opening all parts, derusting, cleaning, overhualing comprising of repairs/replacement of unserviceable parts of pump sets and taking to workshop (if reqd) for repairs. Reassembling of pump set mounting and fixing on base channel, recoupling of suction & discharge line realignment commissioning and testing in respect of centrifugal/multistage pump of capacity 50 to 60 HP complete all as specified and directed by Engr-in-Charge. Note :(i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of parts shall be measured and paid separately under respective item of sch A (BOQ).
All as per serial item No 01.00 here-in-before but capacity 30 to 40 HP.
All as per serial item No 01.00 here-in-before but capacity 15 to 20 HP.
All as per serial item No 01.00 here-in-before but capacity 7.5 to 10 HP.
New parts for single/multistage pumps of capacity 50 to 60 HP as per manufacturer's composition of existing make of pump as below complete all as specified and directed by Engr-in-Charge.
Pump impeller made out of Stainless Steel. Make : Kirloskar/Wilo Mather Platt or equivalent make as approved by GE.
Pump shaft stainless steel shaft complete with check nut and keys.
Tyre coupling/star coupling.
Gland cup.
Shaft sleeves.
Bearing housing.
Casing housing.
New parts for single/multistage pump of capacity 30 to 40 HP as per manufacturer's composition of existing make of pump as below complete all as specified and directed by Engr-in-Charge.
Pump impeller made out of Stainless Steel. Make : Kirloskar/Wilo Mather Platt or equivalent make as approved by GE.
Pump shaft stainless steel shaft complete with check nut and keys.
Tyre coupling/star coupling.
Gland cup.
Shaft sleeves.
Bearing housing.
Casing housing.
New parts for single/multistage pump of capacity 15 to 20 HP as per manufacturer's composition of existing make of pump as below completeall as specified and directed by Engr-in-Charge.
Pump impeller made out of Stainless Steel. Make : Kirloskar/Wilo Mather Platt or equivalent make as approved by GE.
Pump shaft stainless steel shaft complete with check nut and keys.
Tyre coupling/star coupling.
Gland cup.
Shaft sleeves.
Bearing housing.
Casing housing.
New parts for single/multistage pump of capacity 7.5 to 10 HP as per manufacturer's composition of existing make of pump as below complete all as specified and directed by Engr-in-Charge.
Pump impeller made out of Stainless Steel. Make : Kirloskar/Wilo Mather Platt or equivalent make as approved by GE.
Pump shaft stainless steel shaft complete with check nut and keys.
Tyre coupling/star coupling.
Gland cup.
Shaft sleeves.
Bearing housing.
Casing housing.
Disconnecting electric connection of 50 to 60 HP motor, removing the UNSV motor from existing place by unscrewing the foundation bolts and nuts decoupling from the pump, setting aside and transporting to workshop for repairs including dismantling the motor,cutting/taking out burnt winding of stator, rotor, cleaning the slots, transporting back after repair/winding & re-assembling the same complete all as directed by Engr-in-Charge. Note: (a) Rewinding of motor will be measured and paid separately under relevent item. (b) The rates quoted shall be deemed to include the cost of loading/unloading, transportation, grease, nuts, bolts and washers of any size and shape as required at site and refixing of serviceable motor duly functional and testing complete at its existing location/position complete all as specified and directed.
All as per serial item No. 9.00 here-in-before but capacity 30 to 40 HP motor.
All as per serial item No. 9.00 here-in-before but capacity of 15 to 20 HP motor.
All as per serial item No. 9.00 here-in-before but capacity of of 7.5 to 10 HP motor.
Removing the burnt out winding from the rotor and stator, cleaning the slots, providing high quality of class'B' paper insulation inside the slots, rewinding the motor of capacity 60/50/40/30/20/15/12/10/7.5 HP with super enamel copper wire of same size and guage as per existing rapping up with high quality cotton tape and varnising with super quality oil including drying upto desired temperature and desired time complete all as specified and directed by Engr-in-Charge. Note:- Cost of labour for winding deemed to be included in the rate quoted. Make : Atlas/Devi Dayal or equivalent make.
In repair of 2 to 3 HP pumpset (including motor) by taking out from foundation, dismounting from base channels, strip opening all parts, derusting, cleaning, overhualing, etc for complete repair/ replacement of spare parts such as impeller, shaft, winding, bearings, coupling, body, etc and after repair/ replacement, reassembling of pumpset mounting and fixing on base channel, recoupling of suction & discharge line, realignment, commissioning and testing complete all as specified and directed by Engr-in-Charge.
In repair of 0.5 to 1 HP pumpset (including motor) by taking out from foundation, dismounting from base channels, strip opening all parts, derusting, cleaning, overhualing, etc for complete repair/ replacement of spare parts such as impeller, shaft, winding, bearings, coupling, body, etc and after repair/ replacement, reassembling of pumpset mounting and fixing on base channel, recoupling of suction & discharge line, realignment, commissioning and testing complete all as specified and directed by Engr-in-Charge.
Dismantling following spare parts of submersible pump and motor of cap 5 /3 HP and separating the unserviceable parts cleaning the serviceable parts, re-metalling machinery polishing and re-assembling including replacement of old parts and necessary painting complete all as specified and directed by Engr-in-Charge. Note:- Old unserviceable parts replaced will be measured and paid separately.
Impeller for submersible pump set and motor, complete all as specified and directed by Engr-in-Charge.
Bush for impeller for submersible pump set and motor, complete all as specified and directed by Engr-in-Charge.
Pump bearing No. 6307 C3 complete all as specified and directed by Engr-in-Charge. Make:-SKF/NBC/NRB or equivalent make.
Pump bearing No. 6308 2RS1/C3 complete all as specified and directed by Engr-in-Charge. Make:-SKF/NBC/NRB or equivalent make.
Motor bearing No. 7308 BECBJ complete all as specified and directed by Engr-in-Charge. Make:-SKF/NBC/NRB or equivalent make.
Pump bearing No. 3307 ATN9 complete all as specified and directed by Engr-in-Charge. Make:-SKF/NBC/NRB or equivalent make.
Pump bearing No. 7310 BECBJ complete all as specified and directed by Engr-in-Charge. Make:-SKF/NBC/NRB or equivalent make.
Motor bearing No. 7311 BECBJ complete all as specified and directed by Engr-in-Charge. Make:-SKF/NBC/NRB or equivalent make.
ON load change over switch(in replacement) 320 Amps, 415 volts 4 pole with stainless steel enclosure inculding taking down the old existing change over switch complete all as directed by Engineer -in-Charge. Make-Havells Cat part No IHCNFE0320 or equivalent in Indoasian/Legrand/L&T as approved by GE.
All as per serial item No. 23.00 here-in-before but of size 200 Amps. Make-Havells Cat part No IHCNFE0200 or equivalent in Indoasian/Legrand/L&T as approved by GE.
All as per serial item No. 23.00 here-in-before but of size 160 Amps. Make-Havells Cat part No IHCNFE0160 or equivalent in Indoasian/Legrand/L&T as approved by GE.
All as per serial item No. 23.00 here-in-before but of size 100 Amps. Make-Havells Cat part No IHCNFE0100 or equivalent in Indoasian/Legrand/L&T as approved by GE.
Load line (in replacement ) MCCB 320/350 Amps 4 pole 415 volts with adjustable thermal and fixed magnetic setting of breaking capacity 35/36 KA,Ics=100% Icu including taking down the old existing MCCB complete all as directed by Engr-in-Charge.
All as per serial item No. 27.00 here-in-before but of size 200 Amps.
All as per serial item No. 27.00 here-in-before but of size 160 Amps.
All as per serial item No. 27.00 here-in-before but of size 125 Amps.
All as per serial item No. 27.00 here-in-before but of size 100 Amps.
All as per serial item No. 27.00 here-in-before but of size 63 Amps.
Repair of automatic star- delta starter of capacity 40 - 60 HP with replacement of Phase preventer, Contactor, Timer Switch, Indicators, Start- Stop as push buttons, Thermal Overload relay, MCBs, fuse, etc complete all as specified and directed by Enge-in-Charge.
All as per serial item No. 33.00 here-in-before but of capacity 10 to 30 HP.
Fully automatic star delta motor starte (in replacement) in sheet metal enclosure with single phase protection feature motor rating AC 3 phase 415 volts, 50 Hz for motor of capacity 60 HP as per Havells cat part No. IHHASD1C*A completed all as specified and directed by Engr-in-Charge. Make-Havells/Indo Asian/L&T.
All as per serial item No. 35.00 here-in- before but of capacity 50 HP, Havells cat part No. IHHASDYC* completed all as specified and directed by Engr-in-Charge. Make-Havells/Indo Asian/L&T.
All as per serial item No. 35.00 here-in- before but of capacity 30 HP, Havells cat part No. IHHASDWB* completed all as specified and directed by Engr-in-Charge. Make-Havells/Indo Asian/L&T.
All as per serial item No. 35.00 here-in- before but of capacity 20 HP, Havells cat part No. IHHASDUB* completed all as specified and directed by Engr-in-Charge. Make-Havells/Indo Asian/L&T.
All as per serial item No. 35.00 here-in- before but of capacity 15 HP, Havells cat part No. IHHASDTB* completed all as specified and directed by Engr-in-Charge. Make-Havells/Indo Asian/L&T.
All as per serial item No. 35.00 here-in- before but of capacity 10 HP, Havells cat part No. IHHASDRA* completed all as specified and directed by Engr-in-Charge. Make-Havells/Indo Asian/L&T.
DOL starter (in replacement) of sheet steel enclosure single phase 220 volts, 50 Hz for motor of capacity 5 HP as per Havells cat part No. IHHDOLLA*E completed all as specified and directed by Engr-in-Charge. Make-Havells/Indo Asian/L&T.
Power contactor 3 pole (in replacement) with AC coil AC-3 duty rating at 415 Volts 50 Hz, frame size1 suitable for 60 HP centrifugal pump set as per Havells cat part No. IHPHA100400* complete all as specified and directed by Engr-in-Charge.
Supply and laying, jointing and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 150sqmm 3.5 core laid in trenches,ducts, pipes complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 43.00 here-in-before but of size 50 sqmm 3.5 core.
PVC insulated heavy duty industrial cables single core copper (in replacement ) conductor(flexible) PVC insulated cable 1100 volt nominal area of conductor 95 sqmm inculding taking down existing old unserviceable cable of complete all as directed by Engr -in-Charge.
Copper thimble suitable for 95 Sqmm single core copper cable including taking down the existing unserviceable one complete, all as specified and directed by Engr-in-Charge.
Aluminium thimble of 150sqmm size for cables complete all as specified and directed by Engr-in-Charge.
Digital type Ampere meter (96mm x96 mm) complete (in replacement) with suitable CTs 0-300 Amps as per existing,complete all as specified and directed by Engr-in-Charge. Make : AE/L&T/ABB
In replacement of indicating lamps RYB as per existing, complete all as specified and directed by Engr-in- Charge. Make : AE/L&T/ABB
Digital type (in replacement) volt meter (96mm x96 mm) 0-500 volts as per existing, complete all as specified and directed by Engr-in-Charge. Make : AE/L&T/ABB
Material , labour and fixing of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 52.00 here-in-before but 25 x4 mm galvanised iron strip complete all as specified and directed by Engr-in-Charge.
Painting of pump and motor, frame including surface preparation by scrapping with emery paper and painting two coats of synthetic enamel paint over one coat of red oxide primer of existing colour of approved make to the satisfaction complete all as specified and directed by Engr-in-Charge.
Gland packing type 3 of size 8 mm made of asbestos grip (in replacement) with silicon complete all as specified and directed by Engr-in-Charge. Make : Turner/ Champion/Jyoti.
All as per serial item No. 55.00 here-in- before but of size 10 mm.
MS stud bolts (in replacement ) of existing size suitable for pumps and motors of various capacity installed at installations complete all as specified and directed by Engr-in-Charge.
Grouting nuts and bolts (in replacement) of existing size suitable for pumps and motors foundation of various capacity installed at installations complete all as specified and directed by Engr-in-Charge.
Cement concrete type B-2, 1:2:4 (40mm graded aggregate) as in sub base filling and mass concrete all as specified and directed by Engr-in-Charge.
Cement concrete in foundations, type E-2, 1:5:10 (40mm graded aggregate) as in filling and mass concrete complete all as specified and directed by Engr-in-Charge.
Servicing of diesel engine generating set of capacity 500 KVA/600KVA of any make, including the following works are as under: - (a) Servicing of Engine (i) Re-greasing all grease points. (ii) Tighten the nuts, bolts of pipe lines of fuel oil, lubricating oil, water and check for leakages and examine the all main connections. (iii) Check water/coolant level in radiator. (iv) Check crank case oil level. (v) Clean/replaced lubrication oil filters. (vi) Clean/replaced air filters. (vii) Check that lubricating oil contains no water. Examine lubricating oil and renew if needed under relevent item. (viii) Check tappet clearance and all nuts for tightness. (ix) Wash felt pads of fuel filter. (x) Drain air receiver. (xi) Grease valve stems. (xii) Check all wiring, battery water level, gravity of battery, inspect all bushes and bush holder, cleaning of surface of commutators.
(b) Servicing of alternators (i) Check temp rise of bearings. (ii) Check bushes on exciter commutator and the alternator slip rings run without chattering or sparking. (iii) Check if bushes freely slide in holder and whether bush springs are in order. (iv) Check if oil rings are freely rotating in the bearings. (v) Check oil level in bearings. (vi) Wipe clean the alternator and exciter. (vii) Check all wiring and rectify any defect with new wiring. (viii) Surface and clean the commutator. (ix) Take insulation and earth test on alternator and exciter and if defective investigate cause and remedy. (x) Check joints, clamping and bolting in all the wiring including control panels and rectify any defects. (xi) Check greases in all roller and ball bearings and make up if inadequate. (xii) Check the degree of wear of commutator bushes and renew if necessary. (xiii) Tighten all nuts in the rotors of alternator and exciter. (xiv) Check air gaps between starters and rotors and clean off any projections on the rotor. Note for item No. 1 to 4. items to be replaced will be measured and paid separately, as spupply only and labour for fixing deemed to be include as part of servicing.
All as per serial item No.61.00 here- in- before but 250 KVA to 320 KVA any make complete all as specified and directed by Engr-in-Charge.
All as per serial item No.61.00 here- in- before but 160 KVA to 200 KVA any make complete all as specified and directed by Engr-in-Charge.
All as per serial item No.61.00 here- in- before but 62.5 KVA to 100 KVA any make complete all as specified and directed by Engr-in-Charge.
Supply and fuel filter primary & secondary. (Set of Two) suitable of existing make & specification for 500/600 KVA DG set complete all as specified and directed by Engr-in-Charge.
Supply only fuel filter primary & secondary. (Set of Two) suitable of existing make & specification for 250 KVA to 320 KVA DG set complete all as specified and directed by Engr-in-Charge.
Supply only fuel filter primary & secondary. (Set of Two) suitable of existing make & specification for 160 KVA to 200 KVA DG set complete all as specified and directed by Engr-in-Charge.
Supply only fuel filter primary & secondary. (Set of Two) suitable of existing make & specification for 62.5 KVA to 100 KVA DG set complete all as specified and directed by Engr-in-Charge.
Supply only Oil filter element suitable (in replacement) of existing make & specification for 500/600 KVA DG set. Complete complete all as specified and directed by Engr-in-Charge.
Supply only Oil filter element suitable (in replacement)of existing make & specification for 250KVA to 320 KVA DG set complete all as specified and directed by Engr-in-Charge.
Supply only oil filter element suitable (in replacement)of existing make & specification for160 KVA to 200 KVA DG set complete all as specified and directed by Engr-in-Change.
Supply only oil filter element suitable (in replacement)of existing make & specification for 62.5 KVA to 100 KVA DG set complete all as specified and directed by Engr-in-Charge.
Supply only air cleaner filter element including outer and inner element suitable (in replacement) of existing make & specification for 500/600 KVA set complete all as specified and directed by Engr-in-Charge.
Supply only air cleaner filter element (in replacement) including outer and inner element suitable of existing make & specification for 250 KVA to 320 KVA set complete all as specified and directed by Engr-in-Charge.
Supply only air cleaner filter element (in replacement) including outer and inner element suitable of existing make & specification for 160 KVA to 200 KVA set complete all as specified and directed by Engr-in-Charge.
Supply only air cleaner filter element including outer and inner element suitable (in replacement)of existing make & specification for 62.5 KVA to 100 KVA set complete all as specified and directed by Engr-in-Charge.
Supply only ‘V' belt for dynamo A-49/50 or suitable of existing make & specification for 62.5 KVA to 600 KVA set, complete all as specified and directed by Engr-in-Chrge.
Supply only air cleaner hose pipe with clamps suitable of existing make & specification for 250 KVA to 600 KVA set, complete all as specified and directed by Engr-in-Charge.
Supply only air cleaner hose pipe with clamps suitable of existing make & specification for 62.5 KVA to 200 KVA set complete all as specified and directed by Engr-in-Charge.
Supply only flexible pipe for fuel pump to PT pump with banjo, banjo washer and nut, bolts suitable of existing make & specification for 500/600 KVA set complete all as specified and directed by Engr-in-Charge.
Supply only flexible pipe for fuel pump to PT pump with banjo, banjo washer and nut, bolts suitable of existing make & specification for 250 to 320 KVA set complete all as specified and directed by Engr-in-Charge.
Supply only flexible pipe for fuel pump to PT pump with banjo, banjo washer and nut, bolts suitable of existing make & specification for 160 to 200 KVA set complete all as specified and directed by Engr-in-Charge.
Supply only flexible pipe for fuel pump to PT pump with banjo, banjo washer and nut, bolts suitable of existing make & specification for 62.5 to 100 KVA set complete all as specified and directed by Engr-in-Charge.
Repair/replacement and calibration of FIP of capacity 500/600 KVA DG Sets including replacement of plunger, manifold washer, etc all as required other minor items and testing after re-fixing on engine and setting the rated RPM complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 84.00 here- in- before but of capacity 250 KVA to 320 KVA any make.
All as per serial item No. 84.00 here- in- before but of capacity 160 KVA to 200 KVA any make.
All as per serial item No. 84.00 here- in- before but of capacity 62.5 KVA to100 KVA any make.
Servicing/overhauling of injector nozzle assembly of capacity 500/600 KVA DG Set including nozzles,washers, etc and pressure setting as required and timing shaft with coupling all as required other items complete all as specified and directed by Engr-in-Charge
All as per serial item No. 88.00 here- in- before but of capacity 250 KVA to 320 KVA.
All as per serial item No. 88.00 here- in- before but of capacity 160 KVA to 200 KVA.
All as per serial item No. 88.00 here- in- before but of capacity62.5 KVA to100 KVA.
Dismantling and taking out of self-starter from mounting and to carryout complete servicing/overhauling of the same with carbon brush, armature coil, field coil, solenoid switch, bush and pinion and other related components of DG set capacity 500/600 KVA suitable of existing make & specification complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 92.00 here- in- before but of capacity 250 KVA to 320 KVA.
All as per serial item No. 92.00 here- in- before but of capacity 160 KVA to 200 KVA.
All as per serial item No. 92.00 here- in- before but of capacity 62.5 KVA to100 KVA.
Repair/servicing and overhauling of unserviceable dynamo by dismantling the same from DG set after taking down the fan belt and pulley. Repair of the same with armature coil, carbon (1 set) field coil, clutch bearing etc and other related items and duly re-assembling all the dismantled items and refixing the same on mountings and testing complete of DG set capacity 500/600 KVA suitable of existing make & specification complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 96.00 here- in- before but of capacity 250 KVA to 320 KVA.
All as per serial item No. 96.00 here- in- before but of capacity 160 KVA to 200 KVA.
All as per serial item No. 96.00 here- in- before but of capacity62.5 KVA to100 KVA.
Automatic voltage regulator, Diode forward and reverse rotating rectifier assembly complete including taking down unserviceable AVR of DG set capacity 500/600 KVA suitable of existing make & specification complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 100.00 here- in- before but of capacity 250 KVA to 320 KVA.
All as per serial item No. 100.00 here- in- before but of capacity 160 KVA to 200 KVA.
All as per serial item No. 100.00 here- in- before but of capacity 62.5 KVA to100 KVA.
Turbo repair kit complete of DG set capacity 500/600 KVA suitable of existing make & specification complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 104.00 here- in- before but of capacity 200 KVA to 320 KVA.
Dismantling of radiator complete from DG Sets cleaning/ scraping of depositing manually from outside of the radiator, cleaning of all copper tubes of radiator with descaling solution from inside & outside with forced feed method & with water and air compressor (by using separate chemical pump water pump & all compressor ) plugging of all leakage in welding, brazing of copper tubes, cleaning of fins and gaskets etc of DG set capacity 500/600 KVA suitable of existing make & specification complete all as specified and directed by Engr-in-Charge.
All as per serial item No. 106.00 here- in- before but of capacity 250 KVA to 320 KVA.
All as per serial item No. 106.00 here- in- before but of capacity 160 KVA to 200 KVA.
All as per serial item No. 106.00 here- in- before but of capacity 62.5 KVA to 100 KVA.
Dismantling/opening of alternator by disconnecting of cable connection and flexible coupling nut, bolted and alternator foundation nut bolts including taken back on temporary flat form including strip opening of alternator and checking out warn out part of DG sets of make and capacity 62.5 KVA to 600 KVA complete all as specified and directed by the Engr-in-Charge.
Taking out work out rotor armature winding/outfield coil stator winding and rewinding of rotor armature/field coil stator with supper enamelled copper winding wire of existing gauge and Make: Altas, complete all as specified and directed by the Engineer-in-Charge, for the DG sets of make and capacity 62.5 KVA to 600 KVA. Make: Kirloskar/Cummins/Crompton Greaves.
Insulation of armature with class 'B' insulation and varnishing of armature winding and drying up to desired temperature of DG sets of capacity 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
Insulation of field coil with class ‘B’ Insulation and varnishing of armature winding and drying up to desired temperature of DG sets of capacity 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
Re-assembling of rotor and starter after rewinding and re-fixing of alternator with engine by assembling flexible coupling with alternator, mounting with nuts & bolts including making cable connection complete load of DG set capacity 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
Self-starter 12 V sutable for DG set capacity 62.5 KVA to 100 KVA of existing make and specification including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
Self-starter 24 V suitable for DG set capacity 160 KVA to 600 KVA suitable of existing make and specification including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
Unserviciable governor control card (in replacement ) as per site requirment and existing specifications suitable for 62.5 KVA to 200 KVA as per sample complete all as specified and directed by Engr-in-Charge.
Unserviciable governor control card (in replacement) as per site requirment and existing specifications suitable for 250 KVA to 600 KVA as per sample comlete all as specified and directed by Engr-in-Charge.
Repair/replacement old unserviciable of external battery charging unit 12/24 Volt as per make and specifications complete all a specified and directed by Engr-in-Charge.
Battery cable lead (copper) (in repalcement) positive terminal size 35 Sqmm (198cm long) or as per sample complete all as specified and directed by Engr-in-Charge.
Battery cable lead (copper) (in repalcement) negative terminal size 35 Sqmm (198cm long) or as per sample complete all as specified and directed by Engr-in-Charge.
Inter connection battery cable lead (copper) (in repalcement) with terminal size 35 sqmm (30cm long) or as per sample complete all as specified and directed by Engr-in-Charge.
Carrying out top overhauling to the DG set 320 KVA, 3 Phase 440 volts Make Kirloskar by decarb opening/cleaning cylinder head, valves, rocker arms, plungers, head gaskets packing sets turbo chargers by replacing the piston oil/lubricant compression rings complete, top cover head and cam shift rockers arm gaskets matching of heads valves seat if required for all 12 cylinder and repairs to lubrication and cooling system, by rectifying defects removing of the defective parts for complete replacing defective/damaged metal clamps/rubber houses/dampers/packing pads/gaskets/manifolds/vibration dampers/pipe lines and minor corroded accessories completely required and making necessary control wiring for low lube oil high water temperature, oil pressure gauges/sensors by replacing the defective parts and testing of the DG sets complete all as specified and directed by Engr-in-Charge.
Supply and top up Engine Oil SAE 15W/40 complete all as specified and directed by Engr-in-Charge. Make: HP/Indian oil/Castrol.
Supply and top up Engine Oil SAE 20W/40 complete all as specified and directed by Engr-in-Charge. Make: HP/Indian oil/Castrol.
Supply and re-filling of coolant in sealed pack. suitable for capacity 62.5KVA to 600 KVA complete all as specified and directed by Engr-in-Charge. Make: Valvoline /Castrol super/equivalent as approved by GE.
Supply and re-filling of distilled water in sealed pack, suitable for battery of capacity 62.5KVA to 600 KVA, complete all as specified and directed by Engr-in-Charge.
Replacement battery acid as per sample,complete all as specified and directed by Engr-in-Charge.
Battery terminal with bolt & nuts complete all as specified and directed by Engr-in-Charge.
Engine start push button green suitable for any capacity of DG sets complete all as specified and directed by Engr-in-Charge.
Engine stop push button red colour suitable for any capacity of DG sets complete all as specified and directed by Engr-in-Charge.
Fan belt A-44, A-42, A-41, A-40 or as existing size suitable for DG sets of capacity 62.5 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge.
Alternator (Dynamo) 12 Volts (in replacement) suitable for DG sets 62.5 KVA to 200 KVA complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Mahindra & Mahindra/Crompton Greaves.
Alternator (Dynamo) 24 Volts (in replacement) suitable for DG sets 250 KVA to 600 KVA complete all as specified and directed by Engr-in-Charge. Make: Kirloskar/Mahindra & Mahindra/Crompton Greaves.
Dismantling the broken door of sound proof canopy of the DG set ranging from 500/600 KVA DG set and taking it to nearest workshop for repair, repairing the door with new hings and nut bolts etc and reassembling the same at existing position & testing for proper opening & closing of the doors, including repair of the locking system if required complete all as specified and directed by Engr-in-Charge. Note:- Any cutting/ drilling / welding work required to complete the entire job is deemed to be include in the quoted rate.
All as per serial item No. 135.00 here-in-before but of capacity 250 KVA to 320 KVA.
All as per serial item No. 135.00 here-in-before but of capacity 62.5 KVA to 200 KVA.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 sq. mm 3.5 Core complete all as specified and as directed by Engr-in-Charge.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 sq. mm 3.5 Core complete all as specified and as directed by Engr-in-Charge.
MCCB 4 Pole, 415 V, Adjustable type, 630 Amps with breaking capacity 50 KA complete all as specified and directed by Engr-in-Charge.
MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and directed by Engr-in-Charge.
180 AH 12 Volts batteries (in replacment) for DG sets 62.5 to 600 KVA DG sets complete all as specified and directed by Engr-in-Charge.
Stop solenoid assembly for S12 V DC micro pump (single coil) heavy duty electrical control suitable for 250 KVA to 600 KVA. DG set of existing make & specification complete all as specified and directed by Engr-in-Charge.
SHARMA SALES CORPORATION
MOHAN LAL AND SONS
K S BUILDERS
BARU ENTERPRISES
FANGALIA TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .