Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L1 | Accepted-AOC OK | |
| 2 | L2₹47.1 L+₹2.1 L (4.75%)Rejected-Finance 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹48.8 L+₹3.8 L (8.48%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹61.5 L+₹16.5 L (36.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹63.8 L+₹18.8 L (41.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
24 Nov 2020, 6:00 pmClosed
GE E/M BASE HOSPITAL DELHI CANTT
Garrison Engineer E/M Base Hospital Delhi Cantt-110010
PROVN OF PACKAGE AND DUCTABLE ACS AND CONNECTED INFRASTURUCTURE FOR DENTAL SURGERY ROOMS AND PROVN OF PACKAGE AIR CONDITIONER ALONG WITH HEATING AHU FOR ORTHO WARDS AND CERTAIN OTHER SANCTIONED WORKS AT BASE HOSPITAL UNDER GE E/M BASE HOSPITAL DELHI
2020_MES_343153_4
GE/BH-14/2020-21
Open Tender
Electrical and Maintenance Works
Works
120 days
GE E/M BASE HOSPITAL DELHI CANTT
Class D Category
c(i)
7 documents required · 7 mandatory
₹500
Yes
GE E/M BASE HOSPITAL DELHI CANTT
₹86,000
Yes
27 Jan 2021
2 Nov 2020
26 Nov 2020
2 Nov 2020
24 Nov 2020
10 Nov 2020
Amount
Supply, installation, commissioning and testing Air Cooled, Package Type Air conditioners with Nominal cooling capacity 11 TR, Capacity 132000 BTU/Hour, with charged refrigerent Gas R410A/ 407C, 3 Phase, 415 V, 50 HZ made with Pure polyester powder coated GI steel, comprising of Scroll compressor equipped, copper refirgerant piping as per OEM recommendation upto 25 Mtr (set of two for suction and discharge for each compressor circuit from indoor to outdoor), Anti -corrosion condenser Fin coating for out door unit condenser unit with suitable size condenser coil, fan motor etc, electrtical interconnection between indoor and outdoor units as per OEM recommendation, with precharged refrigerent 407C/R - 410A, antivibration pads with following detailed specifications (as elebroted at Srl Nos 1.01 to 1.02 here in after) complete all as specified and as directed. Make : Voltas Model No :- ACDPUASC1102P or equivalent Model of Carrier/ Hitachi/ Daikin/ O-General/Blue star or equivalent Model of any other Make mentioned in PS.
The intelligent microprocessor controller of Air Conditioners shall be consisting of following :- (a) Seven segment LCD display (b) Touch - Key on/off switch (c) Auto restart after power failture (d) Single phasing/ Phase loss/ Phase reversal (e) Over voltage/ Under Voltage protection (f) Over load / Over curret protection (g) Fault display (h) Time delay for compressor operation (j) Run time equalisation (k) Provision for fire alarm input
The Touch screen controller installed at indoor unit of Air Conditioners shall be consisting of following features :- (a) Compressor status indication (b) Room temperature display (c) Wide temperature range 19-32 °C (d) ON -OFF timer (e) Error Indication (f) Error Reset (g) High speed two way communicatin:- High speed two way communication (RS485) between indoor controller and outdoor unit.
Supply, installation, commissioning and testing Air Cooled, Package Type Air conditioners with Nominal cooling capacity 16.5 to 17TR, Capacity 198000 BTU/Hr with charged refrigerent Gas R410A/ 407C, 3 Phase, 415 V, 50 HZ made with Pure polyester powder coated GI steel, comprising of Scroll compressor, copper refirgerant piping as per OEM recommendation upto 25 Mtr (set of two for suction and discharge for each compressor circuit from indoor to outdoor), Anti -corrosion condenser Fin coating for out door unit condenser unit with suitable size condenser coil, fan motor etc electrtical interconnection between indoor and outdoor units as per OEM recommendation, with precharged refrigerent 407C/R - 410A , antivibration pads with following detailed specifications (as elebroted at Srl Nos 2.01 to 2.02 here in after) complete all as specified and as directed. Make :- Voltas Model No :- ACDPUASC1702P or equivalent model of Carrier/ Hitachi/ Daikin/ O-General /Blue star or equivalent Model of any other Make mentioned in PS
The intelligent microprocessor controller of Air Conditioners shall be consisting of following (a) Seven segment LCD display (b) Touch - Key on/off switch (c) Auto restart after power failture (d) Single phasing/ Phase loss/ Phase reversal (e) Over voltage/ Under Voltage protection (f) Over load / Over curret protection (g) Fault display (h) Time delay for compressor operation (j) Run time equalisation (k) Provision for fire alarm input
The Touch screen controller installed at indoor unit of Air Conditioners shall be with following features :- (a) Compressor status indication (b) Room temperature display (c) Wide temperature range 19-32 °C (d) ON -OFF timer (e) Error Indication (f) Error Reset (g) High speed two way communicatin:- High speed two way communication (RS485) between indoor controller and outdoor unit
Supply, assembly and erection of GI sheet of thickness as mentioned below with C & SS rectangular/square duct made out of 'L' shaped hollow profile, incl all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc, complete with necessary angle iron work for supporting /hanging of duct with fastner/ grouting in wall with necessary cement work and making good complete all as specified and as directed :-
(a) 24 Gauge GI sheet
(b) 22 Gauge GI sheet.
S&F fire proof, double layered, convass clath connection for AHU outlet including inspection opening complete with flanges made our of 22 GSS Sheet on both side for connection to AHE and duct with nuts, bolts complete all as specified and as directed.
Supply, installation, testing and commission of fire dampers complete with smoke detector/ thermister linkage etc and actuator as required for operation complete all as specified and as directed.
Supply, installation, commissioning and testing Air Cooled, ductable Split Type Air conditioners with Nominal cooling capacity 5.5 TR, Capacity 66000 BTU/Hr with charged refrigerent R410A/ 407C, 3 Phase, 415 V, 50 HZ made with Pure polyester powder coated GI steel, comprising of compressor, copper refirgerant piping as per OEM recommendation upto 25 Mtr Appx (set of two for suction and discharge for each compressor circuit from indoor to outdoor), Anti -corrosion condenser Fin coating for out door unit, condenser unit with suitable size condenser coil, fan motor etc electrtical interconnection between indoor and outdoor units as per OEM recommendation, with precharged refrigerent 407C/R - 410A , antivibration pads with following detailed specifications (as elebroted at Srl Nos 6.01 to 6.02 here in after) complete all as specified and as directed. Make :- Voltas Model No :- ACADS05512 or equivalent model of Carrier/ Hitachi/ Daikin/ O-General /Blue star or equivalent Model of any other Make mentioned in PS
The intelligent microprocessor controller of Air Conditioners shall be consisting of following: - (a) Seven segment LCD display (b) Touch - Key on/off switch (c) Auto restart after power failture (d) Single phasing/ Phase loss/ Phase reversal (e) Over voltage/ Under Voltage protection (f) Over load / Over curret protection (g) Fault display (h) Time delay for compressor operation (j) Run time equalisation (k) Provision for fire alarm input
The Touch screen controller installed at indoor unit of Air Conditioners shall be with following features :- (a) Compressor status indication (b) Room temperature display (c) Wide temperature range 19-32 °C (d) ON -OFF timer (e) Error Indication (f) Error Reset (g) High speed two way communication:- High speed two way communication (RS485) between indoor controller and outdoor unit.
Supply, installation, commissioning and testing Air Cooled, ductable Split Type Air conditioners with Nominal cooling capacity 8.5 TR, Capacity 1,02,000 BTU/Hr with charged refrigerent R410A/ 407C, 3 Phase, 415 V, 50 HZ made with Pure polyester powder coated GI steel, comprising of compressor, copper refirgerant piping as per OEM recommendation upto 25 Mtr Appx (set of two for suction and discharge for each compressor circuit from indoor to outdoor), Anti -corrosion condenser Fin coating for out door unit condenser unit with suitable size condenser coil, fan motor etc electrtical interconnection between indoor and outdoor units as per OEM recommendation, with precharged refrigerent 407C/R - 410A, antivibration pads with following detailed specifications (as elebroted at Srl Nos 6.01 to 6.02 here in after) complete all as specified and as directed. Make :- Voltas , Model No :- ACADS08722 or equivalent model of Carrier/ Hitachi/ Daikin/ O-General /Blue star or equivalent Model of any other Make mentioned in PS
The intelligent microprocessor controller of Air Conditioners shall be consisting of following :- (a) Seven segment LCD display (b) Touch - Key on/off switch (c) Auto restart after power failture (d) Single phasing/ Phase loss/ Phase reversal (e) Over voltage/ Under Voltage protection (f) Over load / Over curret protection (g) Fault display (h) Time delay for compressor operation (j) Run time equalisation (k) Provision for fire alarm input
The Touch screen controller installed at indoor unit of Air Conditioners shall be with following features :- (a) Compressor status indication (b) Room temperature display (c) Wide temperature range 19-32 °C (d) ON -OFF timer (e) Error Indication (f) Error Reset (g) High speed two way communicatin:- High speed two way communication (RS485) between indoor controller and outdoor unit.
S&F motorized spring return actuator for device with control panel and temprature sensor complete all as specified and as directed.
Supply, installation, testing and balancing of square shape supply air diffusers with removable core and antismudge ring and volome control dampres, powder coated, extruded alminium construction complete all as specified and as directed.
Supply, installaiton, testing and balancing of square shape returen air diffusers with removable core and antismudge ring and without control dampers, with powder coated, extruded aluninium construction complete all as specified and as directed.
Supply, erection and fixing in position 25 mm thick nitrile duct insulation with Aluminum foil. The thermal insulation shall be 25 mm thick non-fibrous, fire retardant, closed cell, tri- dimensional chemically crosslinked polythylene foam, conforms to class 'O' for fire propagation and class 1 for surface spread of flame & factory laminated aluminum foil complete all as specified and as directed.
S&F Acoustic treatment/ lining of area of AHU room with 22G, GI channels of 50x50 mm size fitted at 600x600mm grids. These griids shall be fitted with 50mm thick, 32 Kg/Cum fiber glass insulation, covered by fiber glass tissue and 24 Gauge, Aluminium perforated sheet and as required. The joint shall be with minimium overlapping of 75mm with 30mmx 3mm aluminium strip covering. All corners shall be provided with 20x20x2mm aluminium angle with stainless steel counter sunk screws complete all as specified and as directed.
S&F acoustic lining of supply air ducting complete with GI frame, tissue paper, 26 Guage perforated AL Sheet, 25mm thick of density 32 Kg/Cum fiber glass insulation complete all as specified and as directed.
M&L Earthing complete with galvanised Iron earth plate eletrode 600x600x6.3 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of the plate not less than 1.5 metre below normal grond level, surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all round the plate with using 4mm dia GI wire as earth wire electrode welded and revetted to earth plate at one end connected to main DBs of Bldg at another end GI earth wire encased in and including 15mm bore GI light grade pipe through upper end of earth plate upto 7.5 Mtr, with 20mm bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, MS funnel with wire mesh fixed on water pipe including execvation earth work, Provn of PCC pit in PCC 1:2:4 type B-1 chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B1 duly reinforeced with MS bars 8mm dia @ 150 mm centre to centre, both ways complete with lifting handle all as shown in electrical plate No 3 of SSR of part-I complete all as specified and as directed.
Supply, laying and connecting XLPE insulated, screemed PVC bedded, galvanised steel strip or wire armoured, electric power cables, heavy duty, 1100 Volts grade with standard aluminium conductor of the following size complete all as specified and directed:-
95 Sqmm, 3 ½ core
10 Sqmm , 4 core
16 Sqmm , 4 core
35 Sqmm, 3 ½ core
S & F distribution board (DB), double door type, made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, MCCB DB, TPN 8 way, with 200 Amps rated copper busbar, 415 Volts, with in built MCCB 125 Amps, 10 KA, 01 No, earth bar, IP 43 protection, flush to wall complete all as specified and as directed. Make : Legrand Model: 5077 47 or equivalent model of Make Metioned in PS
S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 4 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 10 or equivalent model of Make Metioned in PS
S & F MCB TPN, C Curve, 240 Volts, 63 Amp complete all as specified and directed.
M&L for sub main wiring with 4 runs of 16 Sqmm single core, FRLS PVC insulated & unsheathed cable 1100 Volts grade, with multi stranded copper conductor drawing in to and including concealed conduit including PVC rigid conduit medium grade 40 mm dia as per IS with boxes (junction/terminal) all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories, pipe hook etc including all fixtures /fittings and one run of 16 sqmm size FRLS PVC insulated copper conductor as earth wire complete all as specified and directed. (Note: Four runs of 16.00 Sqmm copper FRLS cable & one run of 16.00 Sqmm copper earth wire in and including 40mm dia PVC conduit, medium grade shall be measured as one unit)
S&F angle iron, MS flat to support duct angle iron, flats, nut bolt washers etc, with anchor fastener. Necessary welding work involved shall also deemed to be included in quoted rate include cutting fabrication welding of angle iron / MS Flat, repair to RCC wall, cost of anchor fastener etc complete all as specified and directed.
Supply, fixing and connecting 32 Amp Industrical type Plug and socket suitable for OT equipment connection, suitable for Flush Mounting and surface mounting with Neutral Links with provision for mounting modular devices with inbuilt MCB TP 32 Amp complete all as specified and as directed. Make :- Legrand, Model No 5078 61 or equivalent model of Make Metioned in PS
Supply, installation, testing and commissioning air cooled inverter based split AC unit of capacity 1.5 TR with both heating and cooling functions, electric driven, single phase, charged with Eco friendly Refrigerent, with special health filter and all connected accessories, including provision of copper tubing from indoor unit to outdoor unit of length required at site and making hole in any type of wall, ceiling including PVC drain pipe from indoor unit upto plinth protection of building, Outdoor split AC hanging wall mounted stand and flexible PVC casing pipe minimum 40mm dia, covered on all exposed copper insulated pipe line and PVC wire including taking down old split AC complete set of indoor and outdoor AC with connected accessories etc complete all as specified and as directed. Make : Mitsubishi Cat part No. MSZ/MUZ-HP18VA/ O' General Cat part No. ASGG18LFCD-B or equivalent model of Make mentioned in PS. (Note : Copper tubing required upto 3 mtr shall also deemed to be included in qouted rates.)
S&F Voltage stabilizer for automatic operation, capacity 4 KVA, single phase, naturally air cooled, indoor type & designed for input voltage variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and as directed. Make: V-guard/Bluebird/Emerson
S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 12 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand Model: 5076 12 or equivalent model of Make Metioned in PS
S & F MCB SPN, C Curve, 240 Volts, 100 Amp complete all as specified and directed.
S & F MCB SP, C Curve, 240 Volts, 6 to 32 Amp complete all as specified and directed.
S&F sheet metal enclosure with socket plug top, single pole and neutral, with a two pin earth plug and socket complete with one MCB of capacity 25 Amps, 240 Volts complete all as specified and as directed.
M & L Sub main wiring using two run of single core PVC insulated FRLS cable 4.00 Sqmm copper conductor, multi stranded and 4.00 Sqmm copper conductor insulated cable using as earth wire, drawing in to and including 25 mm dia, medium grade PVC conduit with boxes (junction/terminal) all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with PVC saddles complete all as specified and directed. Note: - Two runs of 4.00 Sqmm copper FRLS cable & one run of 4.00 Sqmm copper earth wire in and including 25mm dia PVC conduit, medium grade shall be measured as one unit.
Supply, installation, testing and commissioning water cooler, five star rating, fully stainless steel, electric driven, single phase, charged withRefrigerent Gas 410R, having storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour complete all as specified and directed. Make:- USHA /Blue star / Sidwal
S&F Voltage stabilizer for automatic operation, capacity 2 KVA, single phase, naturally air cooled, indoor type & designed for input voltage variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and as directed. Make: V-guard/Bluebird/Emerson
Supply, installation, testing and commissioning Reverse Osmosis Plant of out put capacity of 40 Litres per hour, to be attached with water cooler complete all as specified and as directed. Make : Model Kent Elite or equivalent Model of Aquaguard/Blue Star/Livpure
M&L point wiring with 1.5 Sqmm, single core, multi stranded copper conductor, PVC insulated and unsheathed cable (FR), 1100 Volts grade, drawn through and including Surface, rigid, non-metallic, 25mm dia PVC Conduit, as required at site as per IS, including sunk type CI/ steel terminal boxes, including cadmium plated screws as per IS and provision of 3 mm thick phenolic laminated sheet top covers, including 1.5 Sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One 5 Amp socket point controlled by one switch, one way on independent board complete all as specified and directed.
M&L point wiring with 2.5 Sqmm, single core, multi stranded copper conductor, PVC insulated and unsheathed cable (FR), 1100 Volts grade, drawn through and including Surface, rigid, non-metallic, 25mm dia PVC Conduit, as required at site as per IS, including sunk type CI/ steel terminal boxes, including cadmium plated screws as per IS and provision of 3 mm thick phenolic laminated sheet top covers, including 2.5 Sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One 15/5 Amp socket point controlled by one switch, one way on independent board complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way 5 Amps complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way 15 Amps complete all as specified and directed.
S&F Socket outlet 2 in 1, 3 pin, 5 Amps complete all as specified and directed.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 Amps combination complete all as specified and directed.
Supply, installation, testing and commissioning air cooled inverter based split AC unit of capacity 2.0 TR with both heating and cooling functions (Auto Defost), electric driven, single phase, charged with Eco friendly Refrigerent Gas (R-410/R-32), with special health filter and all connected accessories, including provision of copper tubing from indoor unit to outdoor unit of length required at site and making hole in any type of wall, ceiling including PVC drain pipe from indoor unit upto plinth protection of building, Outdoor split AC hanging wall mounted stand and flexible PVC casing pipe minimum 40mm dia, covered on all exposed copper insulated pipe line and PVC wire including taking down old split AC complete set of indoor and outdoor AC with connected accessories etc complete all as specified and as directed. Make : Mitsubishi Cat Part No : MSZ/MUZ-HP24VA/ O General Cat part No : ASGA24JCC or equivalent model of Make mentioned in PS. (Note : Copper tubing required upto 3 mtr shall also deemed to be included in qouted rates.)
S&F Voltage stabilizer for automatic operation, capacity 5 KVA, single phase, naturally air cooled, indoor type & designed for input voltage variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and as directed. Make: V-guard/Bluebird/Emerson
S & F MCB SPN, C Curve, 240 Volts, 63 Amp complete all as specified and directed.
M & L Sub main wiring using two run of single core PVC insulated FRLS cable 6.00 Sqmm copper conductor, multi stranded and 6.00 Sqmm copper conductor insulated cable using as earth wire, drawing in to and including 25 mm dia, medium grade PVC conduit with boxes (junction/terminal) all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with PVC saddles complete all as specified and directed. Note: Two runs of 4.00 Sqmm copper FRLS cable & one run of 4.00 Sqmm copper earth wire in and including 25mm dia PVC conduit, medium grade shall be measured as one unit.
S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN, 6 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand/Siemens/ Schnieder (Multi-9)/HPL.
Supply, installation, testing and commissioning Deep freezer, hard top, capacity 192 litre, having Single door with refregerant R134a (eco friendly refrigerent gas), anologue temp setting, door gasket, having basket shelves, temperature range (-)18 degree to (-) 20 degree range having Castor wheel arrangement with minimum dimentions (1180 x 665 x 830) mm complete all as specified and as directed. Make : Blue star Model No. CHF200 or equvilent Model of Voltas/Carrier
M & L Sub main wiring using two run of single core PVC insulated FRLS cable 2.5 Sqmm copper conductor, multi stranded and 2.5 Sqmm copper conductor insulated cable using as earth wire, drawing in to and including 25 mm dia, medium grade PVC conduit with boxes (junction/terminal) all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook including all fixtures /fittings fixed on wall/ceiling with PVC saddles complete all as specified and directed. Note: - Two runs of 4.00 Sqmm copper FRLS cable & one run of 4.00 Sqmm copper earth wire in and including 25mm dia PVC conduit, medium grade shall be measured as one unit.
Leo Network power systems
RUCHIKA ENGG.WORKS
ARE ESS ENGINEERING SERVICES
M/S SUVIDHA ENGINEERS (PROJECT)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .