Executive Engineer (E), BSNL, Bhubaneswar
Door Sanchar Bhawan, Unit-IX, Bhubaneswar-751022
Misc Electrical works
2026_BSNL_831198_1
NIT NO- 69/BSNL-EDB/2025-26
Open Tender
Electrical and Maintenance Works
20 days
Koraput BSNL BA
3 documents required · 3 mandatory
₹590
A O (Cash), BSNL, O/o GMTD, Bhubaneswar.
₹2,317
Yes
3 Mar 2026
3 Mar 2026
13 Mar 2026
3 Mar 2026
13 Mar 2026
3 Mar 2026
3 Mar 2026 - 9 Mar 2026
Dismantling the defective 62.5 KVA Alternator from the base frame and from the Engine for rewinding with proper tools and tackles etc. complete as reqd. (At T E Malkangiri)
Rewinding of following windings of the Kirloskar Stamford make alternator for 62.5 KVA DG set in an authorized service center/workshop with suitable size and turns super enameled copper conductor as per the original windings i/c insulating, heat varnishing, heating in heat chamber, functional and performance testing etc. complete as required. At least one-year warranty shall be given for the rewinding (At T E Malkangiri)
Stator winding
Stator exciter winding
Re-installation and re-assembling of the repaired 62.5 KVA Alternator at site with suitable tools and tackles and skilled authorized manpower of the Engine /Alternator, making alignment, load testing, commissioning etc. complete as reqd. (At T E Malkangiri)
Replacement of faulty Automatic Electronic voltage Regulator by a new one for 62.5 KVA brushless type 3 phase, 415 volts Alternator (for excitation circuit) i/c connection, setting the excitation and output voltage at rated frequency with load and testing etc. as required. (Make: Crompton Greaves /Kirloskar/ As recommended by manufacturer) (At T E Malkangiri)
Transportation of the above 62.5 KVA alternator from Site ( T E Malkangiri) to Work shop (At Jeypore/Bhubaneswar) and back including loading, unloading & escorting etc as reqd.
Replacement of defective Engine Radiator for 15 KVA (Make, Escorts) including draining coolant/water, disconnecting the inlet and outlet pipes/hoses, dismantling the damaged one and fixing the new radiator, connecting the inlet and outlet pipes/hoses, pouring coolant/water, testing etc as required. (At Mottu BTS site)
Replacement of Radiator short piece pipes by new one of GI pipes with clamps etc. as required.