Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LQualified 101 1ST FLOOR HANSRAJ HABITATS 27 GREAT NAG ROAD BAIDYANATH SQUARE NAGPUR NAGPUR MAHARASHTRA 440009 | 440009 | L1 | Qualified | |
| 2 | L3₹12.4 L+₹2.4 L (24.3%)Qualified DRANGBAL PAMPORE PULWAMA JAMMU KASHMIR 192121 | PULWAMA | JAMMU AND KASHMIR | 192121 | L3 | Qualified | |
| 3 | Qualified | - | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
28 Jan 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GCCM 8MM THICKNESS
GCCM 13MM THICKNESS BOQ Title BOQ GCCM
3060302
GEM/2022/B/1868961
GCCM 8MM THICKNESS,GCCM 13MM THICKNESS
30 days
Jammu And Kashmir; Jammu
Total value wise evaluation
BOQ
6 documents required · 6 mandatory
3 yrs
₹5 L
₹5 L
50%
Exempted
4 Feb 2022
18 Jan 2022
28 Jan 2022
60 days from bid end date (until 29 Mar 2022)
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | GCCM 8MM THICKNESS | Supplying, Providing, Laying and Fixing of GCCM 8 mm specified as per ASTM D8364 for Project Name.
GCCM Technical Specification: Geosynthetic Cementitious Composite Mat (GCCM) should have the following in-service performance properties & having minimum testing values mentioned below:
1. GCCM Classification as per ASTM D8364
(GCCM specification assure the quality parameters of GCCMs in three types to comply against different erosion control applications. It gives standards for testing of Thickness, Mass, Density, Flexural strength, Compressive strength, Puncture resistance, Abrasion resistance, Tensile strength, Freeze-Thaw resistance, etc.)
2. Minimum Thickness as per ASTM D5199 must > 6.5 mm
(Thickness of GCCM must be same before and after curing to ensure the finished lining of product)
3. Initial Flexural Strength (1day) ASTM D8058 should be > 3.5MPa
(Initial Flexural strength is measure of tensile strength. It provides great connect with soil and absorbs ground movement behaviour that allow it to stretch up to 5% of its original size i.e., 50mm per 1m width. Also, it gives plastic bucket failure mode to product.
4. Compressive Strength (28 days) as per ASTM D8329 should be > 50Mpa
(Compressive Strength gives weight carrying which as per ASTM D8364 standards must meet capacity up to 50 metric tonnes per square meter area for type 2 GCCMs and important to sustain high loads for long-term durability)
ASTM D8364 are only standards acceptable to worldwide engineers and private/government organizations which ensures proper quality of GCCMs and any company can test their product for GCCM categories under ASTM D8364 to get proper certifications by undergoing testing procedure. Previous standards such as ASTM C109-02 (for compressive strength) are now modified as per industry applications needs and to maintain overall quality of GCCM products. | 110 | Sqm | Jammu | 30 |
| 2 | GCCM 13MM THICKNESS | Supplying, Providing, Laying and Fixing of GCCM 13mm specified as per ASTM D8364.
GCCM Technical Specification: Geosynthetic Cementitious Composite Mat (GCCM) should have the following in-service performance properties & having minimum testing values mentioned below:
1. GCCM Classification as per ASTM D8364
(GCCM specification assure the quality parameters of GCCMs in three types to comply against different erosion control applications. It gives standards for testing of Thickness, Mass, Density, Flexural strength, Compressive strength, Puncture resistance, Abrasion resistance, Tensile strength, Freeze-Thaw resistance, etc.)
2. Minimum Thickness as per ASTM D5199 must > 12 mm
(Thickness of GCCM must be same before and after curing to ensure the finished lining of product)
3. Initial Flexural Strength (1day) ASTM D8058 should be > 3.5MPa
(Initial Flexural strength is measure of tensile strength. It provides great connect with soil and absorbs ground movement behaviour that allow it to stretch up to 5% of its original size i.e., 50mm per 1m width. Also, it gives plastic bucket failure mode to product.
4. Compressive Strength (28 days) as per ASTM D8329 should be > 60Mpa
(Compressive Strength gives weight carrying which as per ASTM D8364 standards must meet capacity up to 50 metric tonnes per square meter area for type 2 GCCMs and important to sustain high loads for long-term durability)
ASTM D8364 are only standards acceptable to worldwide engineers and private/government organizations which ensures proper quality of GCCMs and any company can test their product for GCCM categories under ASTM D8364 to get proper certifications by undergoing testing procedure. Previous standards such as ASTM C109-02 (for compressive strength) are now modified as per industry applications needs and to maintain overall quality of GCCM products. | 45 | Sqm | Jammu | 30 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_3060302.pdf
GEM_BID
tech-spec-gccm_2022-01-18-12-08-11_cc9c3e9fd508ddf97ec8ebb1fe1e25b5.pdf
BOQ
boq_item_sample_file_2022-01-18-12-08-11_1dbacb6b864da873997ab273e3c76617.csv
BOQ
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .