| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAdmitted-Finance | ₹44.8 L | L1 | Admitted-Finance |
| 2 | L2₹45.9 L+₹1.1 L (2.44%)Admitted-Finance | ₹45.9 L+₹1.1 L (2.44%) | L2 | Admitted-Finance |
| 3 | L3₹46.8 L+₹1.9 L (4.33%)Admitted-Finance | ₹46.8 L+₹1.9 L (4.33%) | L3 | Admitted-Finance |
| 4 | L4₹47.0 L+₹2.2 L (4.83%)Admitted-Finance | ₹47.0 L+₹2.2 L (4.83%) | L4 | Admitted-Finance |
| 5 | L5₹48.5 L+₹3.7 L (8.19%)Admitted-Finance | ₹48.5 L+₹3.7 L (8.19%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | S.S.ENGINEERING CORPORATION L3 | Indu Electricals L5 | CHAVA CONSTRUCTIONS AND ELECTRICAL PROJECTS L7 | BRITE INDUSTRIES L1 | DARSHAN CONSTRUCTION Co. L4 | SUN LIGHT HOUSE L6 | AIRDOT ENGINEERING L2 | SRI SAI ENTERPRISES L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Draining out the old existing unserviceable compressor oil from the AC plant compressor of any capacity and type, supply and Charging of suitable/ same as existing make Compressor Oil complete all as directed by Engineer-in-Charge. | 40 | Ltr | 1,410 ₹56,400 | 1,050 ₹42,000 Lowest | 1,350 ₹54,000 | 1,450 ₹58,000 | 1,300 ₹52,000 | 1,190 ₹47,600 | 1,500 ₹60,000 | 1,255 ₹50,200 |
| 2.00 | Supply and re-filling of Refrigerant gas R-134A / R-22 / 407 complete all as directed.
Make : Refron/Mefron/Freon | 300 | KG | 1,515 ₹4,54,500 | 1,175 ₹3,52,500 Lowest | 1,500 ₹4,50,000 | 1,200 ₹3,60,000 | 1,300 ₹3,90,000 | 1,335 ₹4,00,500 | 1,280 ₹3,84,000 | 1,455 ₹4,36,500 |
| 3.00 | Descaling of condenser any capacity by circulating descaling agent (DC-96) through condensers by forced feed method by removing the end covers of the condensers, cleaning the each tube of condenser thoroughly by brushing, re-fixing the end covers with new rubber gasket, nuts bolts, washers and testing complete all as directed. | 9 | Each Job | 14,510 ₹1,30,590 Lowest | 15,900 ₹1,43,100 | 20,000 ₹1,80,000 | 15,000 ₹1,35,000 | 15,600 ₹1,40,400 | 16,855 ₹1,51,695 | 15,300 ₹1,37,700 | 16,225 ₹1,46,025 |
| 4.00 | Opening covers of AHU, descaling of the AHU coil/ Condensor coil to bring down the high pressure, cleaning of the dust particles formed on the coil system with diluted 'ASFOCLEAN' chemical or Caustic Soda by pouring on the coil with leg pump or mechanical system till the clearing of the dust on the coil as primary wash and using detergent powder or surf water as final wash, testing complete all as directed. | 10 | Each Job | 26,000 ₹2,60,000 | 25,500 ₹2,55,000 | 30,000 ₹3,00,000 | 25,000 ₹2,50,000 Lowest | 26,000 ₹2,60,000 | 28,010 ₹2,80,100 | 25,500 ₹2,55,000 | 27,525 ₹2,75,250 |
| 5.00 | Engineering charges for Inspection, testing, programming & commissioning, draining, vacuumising, re-filling including replacement of spares, re-commissioning, pressure testing of 50 TO 125 TR capacity chiller in AC plant of any type and make to run the smooth functioning all as specified and directed (work should be carried out through OEM)
Notes:1. The unit rate quoted shall be deemed to include for Copper Brazing rods, Nitrogen Gas, LPG Gas Tins, copper filter and capillary, pin type valves as required at site
2. Refrigerant Gas and major spares will be measured & paid separately under relevant items of this BOQ. | 4 | Each Job | 47,500 ₹1,90,000 | 47,300 ₹1,89,200 | 60,000 ₹2,40,000 | 45,000 ₹1,80,000 Lowest | 46,800 ₹1,87,200 | 51,200 ₹2,04,800 | 45,900 ₹1,83,600 | 48,525 ₹1,94,100 |
| 6.00 | Leak / pressure testing of the system of 50 TO 125 TR capacity compressor unit in AC Plant with nitrogen (N2) pressure. After evacuating of existing gas from the system in to empty cylinder by separating the entire system like compressors, condensors, cooling coil and refrigerant lines and rectifying of the leakage including cutting, welding, brazing etc and reconnecting with ‘O’ rings, washers, gaskets etc and flushing out the Nitrogen and vacuumising, recharging the taken out refrigerant gas complete all as directed. | 4 | Each Job | 10,350 ₹41,400 | 9,925 ₹39,700 Lowest | 12,500 ₹50,000 | 10,000 ₹40,000 | 10,400 ₹41,600 | 11,230 ₹44,920 | 10,200 ₹40,800 | 10,525 ₹42,100 |
| 7.00 | M& L for Lathe machine work of Chiller at site or in work shop as required and directed. | 3 | Each Job | 86,200 ₹2,58,600 | 89,900 ₹2,69,700 | 1,20,000 ₹3,60,000 | 84,500 ₹2,53,500 Lowest | 87,880 ₹2,63,640 | 94,940 ₹2,84,820 | 86,190 ₹2,58,570 | 91,525 ₹2,74,575 |
| 8.00 | Disconnecting the unserviceable VFD Drive from the existing position and repair,fix, connecting & testing VFD drive complete all as specified and directed by the Engr-in-Charge. | 1 | Each Job | 5,125 ₹5,125 | 5,200 ₹5,200 | 7,500 ₹7,500 | 5,000 ₹5,000 Lowest | 5,200 ₹5,200 | 5,560 ₹5,560 | 5,100 ₹5,100 | 5,425 ₹5,425 |
| 9.00 | Disconnecting and removing the Headder Line and servicing with chemical and refixing in original position all as specified and directed | 2 | Each Job | 5,125 ₹10,250 | 5,125 ₹10,250 | 8,000 ₹16,000 | 5,000 ₹10,000 Lowest | 5,200 ₹10,400 | 5,615 ₹11,230 | 5,100 ₹10,200 | 5,412 ₹10,824 |
| 10.00 | Disconnecting and removing the un-serviceable TCPM board of chiller unit of 50 TO 75 TR chiller in AC plant of Any Model,Type and Make, from the existing position, replace same board after repair all as specified and directed | 1 | Each Job | 97,100 ₹97,100 | 99,545 ₹99,545 | 1,25,000 ₹1,25,000 | 95,000 ₹95,000 Lowest | 98,800 ₹98,800 | 1,07,850 ₹1,07,850 | 96,900 ₹96,900 | 1,03,752 ₹1,03,752 |
Tender Value
₹47.0 L
EMD Value
₹94,000
Closing Date
18 Aug 2026, 6:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONERS AT VARIOUS LOCATION AT RCI UNDER GE I RND RCI HYDERABAD
2026_MES_781238_1
8456
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(I) R AND D RCI
MES enlisted Class D category c i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹94,000
Yes
8 Sept 2026
28 Jul 2026
20 Aug 2026
28 Jul 2026
18 Aug 2026
11 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Draining out the old existing unserviceable compressor oil from the AC plant compressor of any capacity and type, supply and Charging of suitable/ same as existing make Compressor Oil complete all as directed by Engineer-in-Charge. | 40 | Ltr | - | - |
| 2 | Supply and re-filling of Refrigerant gas R-134A / R-22 / 407 complete all as directed.
Make : Refron/Mefron/Freon | 300 | KG | - | - |
| 3 | Descaling of condenser any capacity by circulating descaling agent (DC-96) through condensers by forced feed method by removing the end covers of the condensers, cleaning the each tube of condenser thoroughly by brushing, re-fixing the end covers with new rubber gasket, nuts bolts, washers and testing complete all as directed. | 9 | Each Job | - | - |
| 4 | Opening covers of AHU, descaling of the AHU coil/ Condensor coil to bring down the high pressure, cleaning of the dust particles formed on the coil system with diluted 'ASFOCLEAN' chemical or Caustic Soda by pouring on the coil with leg pump or mechanical system till the clearing of the dust on the coil as primary wash and using detergent powder or surf water as final wash, testing complete all as directed. | 10 | Each Job | - | - |
| 5 | Engineering charges for Inspection, testing, programming & commissioning, draining, vacuumising, re-filling including replacement of spares, re-commissioning, pressure testing of 50 TO 125 TR capacity chiller in AC plant of any type and make to run the smooth functioning all as specified and directed (work should be carried out through OEM)
Notes:1. The unit rate quoted shall be deemed to include for Copper Brazing rods, Nitrogen Gas, LPG Gas Tins, copper filter and capillary, pin type valves as required at site
2. Refrigerant Gas and major spares will be measured & paid separately under relevant items of this BOQ. | 4 | Each Job | - | - |
| 6 | Leak / pressure testing of the system of 50 TO 125 TR capacity compressor unit in AC Plant with nitrogen (N2) pressure. After evacuating of existing gas from the system in to empty cylinder by separating the entire system like compressors, condensors, cooling coil and refrigerant lines and rectifying of the leakage including cutting, welding, brazing etc and reconnecting with ‘O’ rings, washers, gaskets etc and flushing out the Nitrogen and vacuumising, recharging the taken out refrigerant gas complete all as directed. | 4 | Each Job | - | - |
| 7 | M& L for Lathe machine work of Chiller at site or in work shop as required and directed. | 3 | Each Job | - | - |
| 8 | Disconnecting the unserviceable VFD Drive from the existing position and repair,fix, connecting & testing VFD drive complete all as specified and directed by the Engr-in-Charge. | 1 | Each Job | - | - |
| 9 | Disconnecting and removing the Headder Line and servicing with chemical and refixing in original position all as specified and directed | 2 | Each Job | - | - |
| 10 | Disconnecting and removing the un-serviceable TCPM board of chiller unit of 50 TO 75 TR chiller in AC plant of Any Model,Type and Make, from the existing position, replace same board after repair all as specified and directed | 1 | Each Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
BOQ_875173.xls
BOQ • 0.31 MB
8456PS.pdf
Tender Documents • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .