Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC H NO 1 BLOCK NO 2 SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.1 L+₹5.4 L (36.9%)Rejected-Finance | L2 | Rejected-Finance L2 FOR REJECTED |
Tender Value
Refer Docs
EMD Value
₹38,340
Closing Date
13 Apr 2021, 6:00 pmClosed
HQ COMMANDER WORKS ENGINEER SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA No CWE SGNR 104 of 2020-21 SPECIAL REPAIRS TO BUILDING NO. P-163 (MES-IB) AT SRI GANGANAGAR MILITARY STATION
2021_MES_428843_1
CA NO. CWE SGNR - 104 OF 2020-21
Open Tender
Civil Works
Item Rate
120 days
SRI GANGANAGAR
CLASS E
CATEGORY a (i)
10 documents required · 10 mandatory
₹500
₹38,340
Yes
11 Jun 2021
15 Mar 2021
16 Apr 2021
15 Mar 2021
13 Apr 2021
30 Mar 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding and rubbish off the premises complete all as specified and directed by Engineer - in - Charge.
M&L glazed ceramic coloured tiles, (600x300)x7mm thick as on vertical surfaces like dados or skirting over 10mm thick rendering in CM 1:4, set & jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floor etc set and jointed in cement slurry and pointed in white cement mixed with pigment to match the shade of tiles over and including 15 mm thick screed in CM 1:4 complete all as specified and directed by Engr-in-charge.
Demolition concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed by Engineer - in - Charge.
M&L 75 mm thick PCC 1:4:8 type D2 using 40mm graded aggregate as in sub base fininshing even and fair complete all as specified and directed by Engineer - in - Charge.
M&L 25 mm thick cement concrete flooring type B-0, 1:2:4 (12.5 mm graded stone aggregate) as in flooring finish even and fair complete all as specified and directed by Engineer - in - Charge.
M&L for Vitrified coloured light shade Ceramic tiles 10 mm thick (square/rectangular) polished area of each tiles not exc 0.36 sqm , over 15 mm thick screed bed CM 1:6,in floors etc set and jointed in neat cement slurry and pointed in white cement slurry and pointed in white cement or coloured cement to match the shade of tiles complete all as specified and directed by Engineer-in-charge.
M&L for Vitrified coloured Ceramic tiles 10 mm thick (square/rectangular) polished area of each tiles not exc 0.36 sqm , on vertical surfaces over and including 10mm rendering in CM 1:4 finished even and fair, complete all as specified and directed by Engineer - in - Charge.
Taking down chowkhats or frames (without taking off shutters from the frames) not exceeding 1.5sqm each complete all as specified and directed by Engineer - in - Charge.
Taking down and refixing shutters in same opening after easing Resecuring of any description exc 1 sqm n exc 2.0 sqm each complete all as specified and directed by Engineer - in - Charge.
M& L Plain fillets square, rectangular or triangular in section exc 13 & n exc 25 Sqcm, clean sawn, secured with nails or brads complete all as specified and directed by Engineer in charge
S&F in repair 25 mm prelaminated particle board ,interior grade ,preliminated both sides with decorative choice laminations fixed with screws complete all as specified and directed by Engineer - in - Charge..
Supply solo single piece WC with UF soft close seat cover,hinges,Fixing Accessories ,Accessories set and cistern fittings size : 360*725*735 mm ,s trap-300mmcomplete all as specified and directed by Engineer - in - Charge..
S&F 35mm thick gauged skelton shutters open rebeted and prepared to receive gauze etc edges of framing plain, chamfered or rounded fitted with cut and mitred beady for receiving gauze etc of 35 mm thick and door for first class hard wood rail and style complete all as specified and directed by Engineer - in - Charge.
S&F 35mm thick factory made first class hard wood plain framed panelled shutterrs (Two Panels) with lock rails designers door on both faces the size of rail and style as per IS:1003 (Part-I) kin seasoned and chemically pressure treated all as specified complete all as specified and directed by Engineer - in - Charge.
S&F continous piano hinges mild steel bright finish or galvanised of 30 mm width complete all as specified and directed by Engineer - in - Charge.
M&L two coats of synthetic enamel on wooden surfaces (ordinary tint) over one coat of pink primer over 10cm width or girth including preparation of surface complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
M&L two coats of synthetic enamel paint (ordinary tint) on steel surface over 10 cm width or girth, not otherwise described including preparation of new steel surfacecomplete all as specified and directed by Engineer - in - Charge.
S&F mild steel butt hinges “medium weight” 100mm long cold rolled mild steel complete all as specified and directed by Engineer - in - Charge.
S & F Fiber Glass Reinforced plastic (FRP) Door Frames of three legged of cross section 90mmx45mm having single rebate of 32mmx45mm having single rebate of 32mmx15mm to receive shutter of 30 mm thickness. The laminate door frame molded with fire retardant grade unsaturate polysterresinn and chopped mat.Doorframe laminate shall be 2 mm thick and shall be filled with suitable wooden black in all the three legs. The frame shall be covered with fiberglass from all sides MS stay shall be provided at the bottom to steady the frame complete all as specified and directed by Engineer - in - Charge.
S & F 30mm thick glass fiber reinforced plastic (FRP) paneled door shutter of required color and approved brand and manufacture made with fire retardent grade unsaturated polyster resin moulded to 3mm thick FRP laminated for forming hollow rails and style with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP laminate for panels for conforming to IS:14856-2000 complete all as specified and directed by Engineer - in - Charge.
S&F 150 mm Fabricated Extruded aluminium alloy handles D- type complete all as specified and directed by Engineer - in - Charge.
S&F 150 mm Fabricated Aluminium anodised barrel tower bolts complete all as specified and directed by Engineer - in - Charge.
S&F 100 mm Butt hinges stainless steel complete all as specified and directed by Engineer - in - Charge.
Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engineer - in - Charge.
M&L 15mm thick rendering in CM 1:6 to brick / concrete wall surfaces finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L 15mm thick rendering in CM 1:4 to brick / concrete wall surfaces finished even & smooth without using extra cement complete all as specified and directed .
M&L 5 mm thick rendering in CM 1:3 on fair faces of concrete surfaces as on ceilings finished even and smooth complete all as specified and directed by Engineer - in - Charge.
Dismantling of brick work built in cement mortar of any description complete all as specified and directed by Engineer - in - Charge.
M&L brick work with sub class 'B' Old size Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No.32 here in before but except bricks complete all as specified and directed by Engineer - in - Charge.
M & L brick work with sub class 'B' old size ' Bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed by Engineer - in - Charge.
M&L preparation of new plastered wall surfaces, and chalk whiting as preparatory to distempering and applying two coats of distemper oil emulsion on complete all as specified and directed by Engr-in-Charge.
M & L complete removal of existing treatment on old plastered wall surfaces and applying two coats of oil bound distemper oil emulsion complete all as specified and directed by Engineer - in - Charge.
M & L two coats of cement base paint over a coat of white wash on newly plastered surface of wall including preparation ofsurface complete all as specified and directed by Engineer - in - Charge.
M&L three coats of white wash to undecorated ceiling surfaces including preparation of new surfaces complete all as specified and directed by Engineer - in - Charge.
Demolition of stone slabs and tiles of any description or thickness in floor,aprons laid bedded and pointed in any mortar etc complete all as specified and directed by Engineer - in - Charge.
M&L 20 mm thick granite(Approved colour) table moulded and polished machine cut in jambs,pillars ,skirting/dado, sehlves etc laid over 15 mm thick cement mortar 1:3 screed set and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing polishing all as specified and directed by Engr-in-charge.
S&F MS work as in Stairs framed including strangers traders landing,balusters hand rails etc including cleats,brackets of grade Fe-290 (Gde -165 )etc complete all as specified and directed by Engineer - in - Charge.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engineer - in - Charge.
S & F in repair brass chromium plated tubular towel rail 20mm dia “D” type 60 cm long between flanges including brackets complete all as specified and directed by Engineer - in - Charge.
S&F in repair stainless steel curtain rod 25 mm dia with brackets knob rings(20 cm c/c) etc all as specified and directed by Engr-in-charge.(Approx size of each rod 1.5meters)
S&F in repairs, Brass CP mixer for mixing hot and cold water screwed down for iron pipe and fied complete all as specified and directed by Engineer - in - Charge.
S & F in repairs bib taps with wall flange 15mm dia, cast copper alloy chromium plated, fancy type with crutch or butterfly handle, screwed down screwed for iron pipe complete all as specified and directed by Engineer-in-charge.
S&F in repair Grating doom 100mm dia PTMT (minimum weight 25gms) complete all as specified and directed by Engineer - in - Charge.
S & F in repairs stop/Angle valves 15mm dia, cast copper alloy fancy type chromium plated with long shank and cup (concealed type) serewed down, high pressure , with crutch or butter fly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
Taking up or down for 15 mm bore steel water tubing galvanised with connection including cleaning for refixing complete all as specified and directed by Engineer - in - Charge.
S&F steel water tubing galvanised 15mm bore, “medium grade” with all fittings and fixed to walls and ceiling or in floor complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 50 here in before but fixing with new fittings only complete all as specified and directed by Engineer - in - Charge.
Taking up or down for 20mm bore steel water tubing galvanised with connection including cleaning for refixing complete all as specified and directed by Engineer - in - Charge.
S&F steel water tubing galvanised 20mm bore, “medium grade” with all fittings fixed to wall and ceiling or in floor complete all as specified and directed.
All as per Srl item No. 53 here in before but fixing with new fittings only complete all as specified and directed by Engineer - in - Charge.
M&L mortice lock with two lever (vertical type) with brass body 100 mm long complete all as specified and directed by Engineer - in - Charge.
S&F 40 mm dia brass polished cupboards knobs fixed with nut screw and washer of mild steel bright finished complete all as specified and directed.
S&F in repairs health faucet 2 in 1 with 1.5 m tube and hook of same complete all as specified and directed by Engineer - in - Charge.
Dismantling water tank capacity exc 500 ltrs N. exceeding 1000 complete all as specified and directed by Engineer - in - Charge.
S&F rotational moulded polyethylene water storage tank 1000 ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer - in - Charge. (Note : PVC tanks shall be ISI marked and having two layers)
S&F in repair stainless steel toilet paper holder complete all as specified and directed by Engineer - in - Charge.
S&F in repairs 125 mm size over head shower swivel type chromium plated with arm compllete all as specified and directed by Enginer-in-charge.
S&F in repair door stoper and silencer rubber 50-70 mm dia complete all as specifed and directed by Engineer-in-charge.
M & L mild steel TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 63 here in before but 5mm dia and over upto and including 10 mm dia in stirrups, spacers and binder etc complete all as specified and directed by Engineer - in - Charge.
M&L providing 75 mm thick cement concrete type 1:3:6 (20 mm graded) C-2 as in Plinth protection all as specified and directed by Enginer-in-charge.
S&F in repair thin rim table top basin ,shape triangle of size :600x 410x100 mm model code :Jaquar LYS-WHT-38901N complete all as specified and directed by Engineer - in - Charge.
Fixing only in repair water closet (Padestal pattern) complete all as specified and directed by Engineer - in - Charge.
Dismantling brick tiles, single layer on roof complete all as specified and directed by Engineer - in - Charge.
Demolition of old mud phuska, removing rubbish of the premises cleaning surface and preparing to receive new mud plaster complete all as specified and directed by Engineer-in-Charge.
M&L 40mm thick brick tiles laid on 15 mm thick CM 1:6 & joint grouted flush in CM (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 70 here in before but except brick tiles complete all as specified and directed by Engineer - in - Charge.
M&L applying bitumen 85/25 hot @ 1.2 Kg per sqm including cleaning surfaces, over 80mm thick average consolidated thick mud phuska on flat roofs incl 25mm thick mud plaster and 3 mm thick leeping plaster all as specified and directed by Engr-in-charge.
M&L for 80mm thick average consolidated thickness mud puska on flat roofs including 25mm thick mud plaster complete and 3 mm thick leeping plaster all as specified and directed by Engineer-in-Charge.
M&L machine cut Kota stone slab flooring 20-25mm thick over cement screed base 20 mm thick in cement mortar 1:6 laid and jointed withgrey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including Mirror Polishing finishing comple all as specified and directed by Engineer-in-Charge.
S&F in repairs 5mm thick 3 tier Glass Shelf Glass fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed by Engineer - in - Charge.
SF in repair towel ring brass glossy finish complete all as specified and directed by Engineer - in - Charge.
SF in repair soap dish brass glossy finish complete all as specified and directed by Engineer - in - Charge.
Taking down eaves gutters and rain water pipes (any size or pattern) including all fittings, heads, shoes, bends, swan – necks, etc. including cleaning of any description complete all as specified and directed by Engineer - in - Charge.
M&L bands straps supports or stays for rainwater ventilating pipes including bolts confirming to Fe 410 -0 or Fe 310-0 all as specified and directed by Engr-in-charge.
Cutting holes into brick wall for inserting hold fast etc built in C:M n exc half brick wall and making good in cement conc 1:2:4 complete all as specified and directed by Engr-in-charge.
S&F 110mm bore PVC (SWR) rain water pipe single socketed in any length with rubber ring joints, jointed with solvent joint fixed to wall complete all as specified and directed by Engineer - in - Charge.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed by Engineer - in - Charge.
M&L for PCC 1:2:4 type B2(20 mm graded aggregate) as in roof padding/mass concrete complete all as specified and directed by Engineer in chgarge.
Providing and applying waterproofing work with polyester reinforced APP membrane sheet of thickness 3mm by Mechanically clean the RCC slab and wall with wire brush / coir brush to freee from all loose materials like dust, dirt ect make wattah / coving of 50x50 mm at all horizontal and vertical joints to avoid right angle turning with polymer based mortar. Apply one coat of solvent based bitumen primer on cleaned & leveled surface @ 3-5 Sqmtr / ltr per coat. Unroll the Dr. FIxit Torchshield roll after application of primer. Align the Dr. FIxit Torchshield roll correctlv & re-roll it in alignment before torching. Use gas burner to heat substrate and underside to softening points. When the embossing disappers, roll forward and press fimly against substrate to bond from the lower end towards the higher end. Keep overlap margin for minimum 100mm. Heat both the overlaps and use round tipped trowel to seal overlap. Excess compound shold be smoothened and pressed into seam using hot trowel complete all as specified and directed by Engineer - in - Charge.
M&L for heat resistant aluminium painting on roof water proffed surface complete all as specified and directed by Engineer in charge.
Repair to damaged concrete slab by using micro mortar and concrete in following stages:-(a) Removing the falling mortar and concrete from RCC slab and cutting the affected area in geometrical shape.(b) Cleaning the rusted reinforcement and applying rust removal.(c) Inserting addl reinforcement in case the cross sectional area reduction is more than 20 percent. Welding the reinforcement with existing one and supporting the new supporting adequately on walls if required with grout.(d) Providing micro mortar and concrete over bond coat to cover the reinforcement and slab surface.(e) Providing adequate formwork and scaffolding if required.(f) Curing the surfaceRust removal, Bonding agent, grout, micro mortar and concrete and related chemicals shall be of Dr Fixit/BASF and STP. Work is to be got executed from authorized applicators of company.
Dismantling cast iron work of any description and any position complete all as specified and directed by Engineer - in - Charge.
S&F 100mm bore cast iron sand cast soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer - in - Charge.
S&F 75mm bore cast iron sand cast soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer - in - Charge.
S&F 100mm bore cast iron bends sand cast (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed by Engineer - in - Charge.
S&F 75mm bore cast iron bends sand cast (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access door complete all as specified and directed by Engineer - in - Charge.
Extra over 100 cast iron pipes and fittings if lead joint is provided in lieu of cement jointcomplete all as specified and directed by Engineer - in - Charge.
Extra over75 mm cast iron pipes and fittings if lead joint is provided in lieu of cement joint complete all as specified and directed by Engineer - in - Charge.
Providing and applying tow component cementitious and acrylic flexible waterproofing and protective coating ,two coats with 1mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance cm / km is 0.09 of Dr. Fixit PIDIFIN 2K / SMART CARE 2K or equivalent with a paint brush over existing roof surface. The polyesterreinforced coated net of 45 g / m2, 2.5mm x 2.5mm is laying on the surface immediately on the first coat of two component modified polymer Dr. Fixite pidifin 2K or equivalent. After removal of all loose materials like dust etc wtih wire brush coir brushes from roof surface to get absolutely cleaned surface free of foreign contaiminant filling of crack and patches with polymer based reapir mortar / micro concrete,after the repairing work making the gola on surrounding walls junction and seal the vertical walls upto 300mm in case of core cutting on the surface, the joint is seal with non-shrink grout. The work complete as per the direction of Engineer-in-Charge. (Work shallbe executed through specialized agency) Note: Waterpofing treatment is carried out in the complete sunken area and upto 450 mm outer walls of the sunken area. This wall area should be including in the measurement book.
M&L for CI floor trap 75 mm with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified and directed by Engr-in-charge.
M&L for CI floor trap 100 mm with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified and directed by Engr-in-charge.
S&F stainless (grade 304) railing made of hollow tubes, channels, plates etc., including welding , grinding, buffing , polishing and making curvature ( wherever required) and fitting the same with necesssary stainless steel nuts and bolts complete , i/c fixing the railing steel olts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangements as per approval of engr-in-charge.
S&F 5mm thick plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining, Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of Solvent Cement and fixing at site. complete all as specified and directed by engr-in-charge
S&F 5 mm thick PVC sheet fillet of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing
Demolation of cement concrete in sunken portion and floor all as specified and directed by Engr-in-charge.
Supply only Water proofing compound
M&L for cement concrete type E2 1:5:10 (40mm graded aggregate) as in filling and mass concrete etc complete all as specified and directed by Engr-In_charge
Taking down chowkhats or frames (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 sqm each complete all as specified and directed by Engineer - in - Charge.
M&L for two coats French polishing on wooden surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler complete all as specified & directed by Engineer-in charge.
S & F 150 mm long Brass handles, cast type, polished bright (Handles shall be of pattern/design as approved ) complete all as specified and directed by Engineer - in - Charge.
S&F 200 mm Brass barrel tower bolts, but with barrel of extruded section complete all as specified and directed by Engineer - in - Charge.
S&F Brass,sliding door bolt with sand or die-cast brass hasp ,staple (Bolt type) and fixing bolt with rolled or drawn brass bolts and fixed ,Length of bolt in 300 mm complete all as specified and directed by Engineer - in - Charge.
S&F Aluminium frame for window, ventilators with one or more rebates including joining cleat for fixing etc complete with powder coating on Aluminium minium thickness of powder coating 50 micron as per the specification the top and bottom horizontal members and vertical members adjacent walls shall be fixed with floor, ceiling walls and cills where required and fixing with the help of rawl plug and screw or with fixing clip or with expansion hold plate fasteners . Aluminium section shell be smooth, rust free, straight mitred and jointed mechanically where ever required all complete as per the direction of Engineer-in-charge
S&F Anodised aluminium window and ventilator shutters,side hung type without sash bars aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles two Nos. in each door, hinges, anodized aluminium snap beading, screws with powder coating of any colour (thickness of powder coating not less than 50 micron) and complete all as specified and directed by Engineer-in-Charge.(Note:- Sheet glass will paid separately.)
S&F Aluminum Grill any pattern fixed with Aluminum Frame ccomplete all as specified and directed by Engineer - in - Charge. Note- Aluminum frame shall be Measured and paid seperately
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed by Engineer - in - Charge.
S&F 100 mm Aluminium anodised barrel tower bolts complete all as specified and directed by Engineer - in - Charge.
S & F pressed steel door frames with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., size of frame 105x60mm complete all as specified and directed by Engineer - in - Charge.
Demolition of RCC slabs, chajjas and similar items complete all as specified and directed by Engineer - in - Charge.
M & L RCC 1:1½:3, Type A–1 for slabs supported on walls, beams, columns and in shelves, the like complete all as specified and directed by Engineer - in - Charge.
Form work to soffits of suspended slabs, such as roof slab, chajjas and similar work not exceeding 200mm thick with rough finished surface of concrete complete all as specified and directed by Engineer - in - Charge.
Taking down carefully aluminium point wiring (light, fan, socket or power, bell complete fitting such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc complete all as specified and directed by Engineer - in - Charge.
M & L for concealed conduit point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for modular metal flush boxes in suitable length and thickness for mounting, switches, sockets,fan regulator with frame and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and direced by the Engineer in charge. (Make of cable -Havells/Anchor and conduit pipe:-AKG/Plaza/Suprem)
All as per Srl item No -115 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No -115 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 115 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed by Engineer - in - Charge.
All as Srl item No. 115 here in before but for one light point controlled by two 2 ways switches complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 115 here in before but for call bell point complete all as specified and directed by Engineer - in - Charge.
S & F modular switch 5/6 Amps single pole one way,one module complete alongwith modular cover plate frame and flush box all as specified and directed by Engineer - in - Charge.
S & F modular switch 5/6 Amps single pole two ways complete alongwith modular cover plate frame and flush box all as specified and directed by Engineer – in - Charge.
S & F modular switch socket combination 5 pin, type 5/6 Amps 5 in 1 flush type complete alongwith modular cover plate frame and flush box all as specified and directed by Engineer - in - Charge.
S & F modular switch socket combination 6 Pin, 5/16 Amps flush type complete alongwith modular cover plate frame and flush box all as specified and directed by Engineer - in - Charge.
S & F modular socket outlet 5 pin 5 Amps flush type complete alongwith modular cover plate frame and flush box all as specified and directed by Engineer - in - Charge.
S&F modular bell push 5 Amp complete alongwith modular cover plate frame and flush box all as specified and directed by Engineer – in - Charge.
S & F modular stepped type, fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in - Charge
S&F Electronic Bell AC 230 Volt single pole ding dong type complete all as specified and directed by Engineer - in - Charge.
S & F ceiling rose surface bakelite three terminals complete all as specified and directed by Engineer - in - Charge.
Supply and fix in replacement Industrial socket metal clad plug and socket with MCBs single pole 20 Amp complte all as specified and directed by Engineer - in - Charge.
S & F in replacement of existing light fitting with LED batten with aliminium housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. Make:Havells cat part No: LUMILINEPLUSBS20WLED865SPCSS, Bajaj cat part no.: BCLSBAL 20W CW ,Crompton cat part no. : CCS-100-20-65-HL2-DP-NWH).
S&F in replacement security light fitting LED TYPE 25 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge (Make:Havells cat part no: ENDURAPEARLSL25WLED757SASYTOPCMP, Bajaj cat part no. BRLEP 25W LED WH, Crompton cat part no. LSTS-25-CDL-M)
S&F in replacement decorative wall light fixture made up of poly carbonate suitable for 10 watt LED lamp complete all as specified and directed by Engineer - in - Charge. ( make- havells cat part no: LHFOFWE1TZ1W012 or equivalent make in bajaj,crompton)
S & F in replacement LED Bedside Light (White,3000k) 3 Watt, with flexible arm suitable for reading complete all as specified and directed by Engineer - in - Charge. Make : Philips 48042 or equivalent make in Havells,Bajaj
S & F in replacement Water tight bulk head fitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LED lamp all as specified and directed by Engineer - in - Charge (Make:Havells cat part no : HEXAFT10WLED857SSYMBOPC, Bajaj cat part no. BIBWP 10W LED, Crompton cat part no. LBHP-10-CDL)
S & F in repair compact & decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1X10 watt fitting 2 ft version including LED lamp 10 watt ccomplete all as specified and directed by Engineer - in - Charge. Make : Havells cat part no LUMILINEPLUSBS10WLED865SPCSS, Bajaj cat part no. BCLSB 10 WH, Crompton cat part no. LDL-10-CDL)
S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge.
S&F LED lamp 9W for angle holder complete all as specified and directed by Engineer - in - Charge.
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FR/FRLS stranded copper conductor drawn in and including steel dia 25mm “medium quality” conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge.
S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 4 sqmm including cutting chasing and grouting PVC pipe including Tee, Elbow, Bend etc and including 4.0 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia concealed PVC conduit, medium grade, ISI marked.Make;- HPL/Indo Asian/Havells/ Anchor(Note :- two lengths of 4.0 sqmm cable and one length of 4.0 sqmm earth cable along with PVC conduit will be measured as one running length) complete all as specified and directed by Engineer - in - Charge.
S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 2.5 sqmm including cutting chasing and grouting PVC pipe including Tee, Elbow, Bend etc and including2.5 sqmm copper conductor single core wire connected by common earth all as specified. Including 20 mm dia concealed PVC conduit, medium grade, ISI marked.Make;- HPL/Indo Asian/Havells/ Anchor(Note :- two lengths of 2.5 sqmm cable and one length of 2.5 sqmm earth cable along with PVC conduit will be measured as one running length) complete all as specified and directed by Engineer - in - Charge.
S & F in replacement sheet metal enclosure for double door BDs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S&F in repairs Sheet metal enclouser for doble door Vertical DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mouting VTPN 12 Way 415 Volt ISI marked 250Amps busbar stove enameled dust and vermin proof,IP:43 protection suitable for incorporation FP MCCB(V-Tech) N1 Frame upto 125A ,Isolators and including give connection with wire and cable etc complete all as specified and directedby engineer -in-charge .
S&F in repairs MCCB TP&N 63 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GI and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on completion all as specified and directed by Engr -In - Charge
S&F 3 pin telephone socket RJ-11 with metal flush box having holes for 20mm conduit entry for telephone connection all as specified and directed by Engr-in-Charge. Make : Havells/Legrand/ABB
S&F RJ-45 data socket for connection of data network all as specifed and directed by Engr-in-Charge.
S&F rigid non metaliic PVC conduit 20mm dia inclusive of all tees, bends , elbows ,reducers , bell mouth tube ends and complete with all fixing accessories such as couplers , lock nuts, saddles, pipe hooks etc all as specified and directed by Engr-in-Charge. ---------------------------------------------------------------------------------------------- Note : A sum of Rs. 46,413.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 32 (Schedule of Credit) of Tender document
Aggarwal brothers and company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .