Electrical Works in connection to "Raising of platform at BARN, DAKE, BLYG , BLYH ,TALA, PQS, LKF , MJT , SNR (Total = 16 nos) with cement concreting with all ancillary works under the jurisdiction of Sr. DEN/I/SDAH."
ELEG-OT-1341-2026-27
ELEG-OT-1341-2026-27
Open
8 Months
Rae Bareli, Uttar Pradesh
₹0
₹1.5 L
30 Jun 2026
30 Jun 2026
9 Jul 2026
I-NS Schedule - (Cabling and Wiring Works) 2928099.00 Below/P
"Trenching and laying of cable underground by soil cutting through suitable dia HDPE 1 pipe, without sand and bricks including refilling of trench by excavated soil and make good of surface as its original condition, (The cable trench should be of minimum 1000 mm depth).. (HDPE Pipe Make: Skipper/ Capital Polyplast/ Chaika Polymers/ Utkarsh/ Ashirvad/Arpan/Ori Plast) (L.T. Cable will be supplied by Railway)"
"Cable laying through 2" dia. GI Pipe along with supply of GI Pipe as per General Specification. (G.I. Pipe Make: TATA/ Jindal / Bansal ) (L.T. Cable will be supplied by Railway)"
"Cable laying through 3" dia. GI Pipe along with supply of GI Pipe as per General Specification. (G.I. Pipe Make: TATA/ Jindal / Bansal ) (L.T. Cable will be supplied by Railway)"
"Drawing of L.T. cable through PF wall / Structure by cleating / clamping etc as per General Specification. (L.T. Cable will be supplied by Railway)"
"Drawing of LT cable in Concealed way through PF wall / structure / building wall etc. as per General specification. 'L' hook should be provided at approx. every half meter length. (L.T.Cable will be supplied by Railway)"
"Drawing of LT cable through inside of GI octagonal/tubular pole for loop in & loop out. (L.T.Cable will be supplied by Railway)"
Wiring of light point with 1.5 sq.mm PVC copper wire FRLSH through PVC conduit pipe from inside JB with porcelain fuse kit-kat / MCB of rating 16 A to top of G.I Octagonal pole 5.5 mt. long along with copper ECC of size 1.5mm2 as per General specification of IE Rule. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/ KEI/Mescab)"
"Wiring/Re-wiring of Light and Fan points with 1.5 sq.mm., PVC insulated 1100V grade FRLSH single core, M/Strand copper wire through suitable size (ISI marked) PVC conduit 8 pipe/casing/concealed way along with ECC of 1no. 1.5 sq.mm. , PVC insulated single core, M/Strand FRLSH copper wire as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GM Modular/ Legrand/Crabtree/ Havells/Hager)"
"Wiring of 6 Amp plug board consisting with one 6A plug socket and one 6 amp switch by 2 nos. single core FRLSH grade, PVC insulated, copper conductor wire of size 1.5 mm2, 9 1100V grade for phase and neutral alongwith 1 no. single core FRLSH grade, PVC insulated, copper conductor wire of size 1.5 mm2, 1100V grade for Earth Continuty Conductor (ECC) through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way as per General specification of IE Rule. (PVC wire Make: Havells/Gloster/Polycab/RR Kabel/KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GM Modular/ Legrand/Crabtree/ Havells/Hager)"
"Supply, laying, and termination of sub-main wiring comprising 2 run of 4mm² single- 10 core copper conductor PVC FRLSH insulated wires, along with one run of 2.5mm² copper Earth Continuity Conductor (ECC), through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way as per General specification of IE Rule. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/ KEI/ Mescab)"
"Supply, laying, and termination of main/sub-main wiring comprising 2 run of 6mm² 11 multi-stranded single-core copper conductor PVC FRLSH insulated wires, along with one run of 2.5mm² copper Earth Continuity Conductor (ECC), through suitable size (ISI marked) PVC conduit pipe/casing/ concealed way as per General specification of IE Rule. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/ KEI/ Mescab)"
"Supply, laying, and termination of sub-main wiring comprising 2 run of 4mm² single- 12 core copper conductor PVC FRLSH insulated wires, along with one run of 2.5mm² copper Earth Continuity Conductor (ECC), through G.I. conduit pipe, for shed etc. as per General specification of IE Rule. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/ KEI/ Mescab)"
"Supply, laying, and termination of sub-main wiring comprising 2 run of 6mm² single- 13 core copper conductor PVC FRLSH insulated wires, along with one run of 2.5mm² copper Earth Continuity Conductor (ECC), through G.I. conduit pipe, for shed etc. as per General specification of IE Rule. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/ KEI/ Mescab)"
"Supply, laying, and termination of sub-main wiring comprising 3 run of 4mm² single- 14 core copper conductor PVC FRLSH insulated wires, along with one run of 2.5mm² copper Earth Continuity Conductor (ECC), through G.I. conduit pipe, for PF shed etc. as per General specification of IE Rule. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/KEI/Mescab)"
"Supply and fixing of 3 pin, 5 amp, ceiling rose on the supplied metal box of size (75 mm x 75mm x 60 mm deep) on surface or in recess with suitable size of phenolic laminated sheet 15 cover in front, painting etc. as required including electrical connection for Light & Fan points with 2 nos. 2.5 sq.mm, 1100V grade Copper PVC FRLSH, Single core, Multi-strand wire(for phase and neutral) along with 1 no. single core FRLSH PVC insulated copper wire of size 1.5 sq.mm, 1100V grade for ECC through flexible PVC conduit from ceiling rose connected with Sub-main. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/ KEI/Mescab) " Above/
II-NS Schedule - (LED Luminaries) (LED luminaries should cover a
"Design of mounting layout ,Supply, installation of LED Flood light Luminaire 1 100W(approx), luminaire efficacy>= 120lm/W as per General Specification with high pressure die cast housing complete with all accessories and conform to minimum IP66 protection rating or higher.. (Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic/ Orient/ Signify/Ecolink) "
"Designing of mounting layout, Supply, installation, connection and commissioning of 2 LED luminaire 4ft., 2X18W or above (min. IP:65, indoor type) as per General Specification including batten complete with all accessories including fixing with G. I. clamps made of G. I. Flat of suitable size & G. I. Nut, bolts etc. (Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic/ Orient/ Signify/Ecolink) "
"Design,Supply, installation and mounting layout for integrated LED TUBE LIGHT 4ft. 3 luminaires 1 X 20W (approx.) (Extruded Aluminium LED Batten) (IP:20) (indoor type) as per General Specification including fixing with G. I. clamps made of G. I. Flat of suitable size & G. I. Nut, bolts etc. (Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic/ Orient/ Signify/Ecolink)"
"Design of mounting layout, supply, connection, fixing, testing, and commissioning of integrated LED trunking light fixtures, 40W, 4-ft (1200 mm)/80W, 8 ft (2400 mm)/ 120 W, 12-ft (3600 mm) length length, as per General Specification with linear extruded aluminium housing, sturdiness 4 & excellent corresion resistance powder coated, LED chip efficacy >140 lm/W, Polycarbonate Diffuser, IP>54 luminaire, BuiltIn industrial grade Constant Current electronic LED driver, suitable for Seamless surface or suspended mounting includes all required accessories and suitable installation arrangement for complete functional deployment. (Quantity of this item will be assessed in multiple of 1200 mm, i.e; 4 ft = 1 nos/ 8 ft = 2 nos/ 12 ft = 3nos.) (Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic/ Orient/ Signify/Ecolink)"
"Design of mounting layout ,Supply, installation for LED street light luminaires of approximately 60W rating, having a minimum luminous efficacy of 120lm/W as per General 5 Specification. The luminaires shall be housed in pressure die-cast aluminium enclosures and conform to minimum IP65 protection rating or higher. Installation/fixing of street light fitting should be made with existing/supplied arm bracket of G.I. pole / Rail pole. (Make - Bajaj/ Philips/ Havells/ Crompton/ Panasonic/ Orient/ Signify/Ecolink)" Above/
III-NS Schedule - (General Electrical Works) 2460968.00 Below/P
Supply and fixing of GI fabricated cable end box, 4 way as per Sr. DEE (G)/SDAH's Drg. No. SDAH/G/MISC/40 dt. 10.12.07.
"Supply and Fixing of thermoplastic fabricated cable end box, 4 way. As per Sr. DEE/G/SDAH's Drg no.- SDAH/G/4/2024, Dt.- 13.09.2024. Scale: N.T.S (Make: Grasp/Legrand/Hensel/CAPE)"
"Supply, concrete foundation & erection of GI Octagonal Pole 5.5mtr. Pole section bottom dia 150mm, top dia 75mm, pole thickness-3mm with base plate 240 x 240x16mm with 4nos. 3 foundation bolts having 25mm dia & of length 700mm along with single/double arm bracket as per General Specification. Loop in & loop out box to be provided inside the pole. Foundation and erection of G.I octagonal pole along with grouting of supplied 4 nos. foundation bolts as per Drg. No. Sr. DEE(G)'s Drg. No. SDAH/G/SS/115 dt. 23.10.09. (Make-B. P. Projects/Transrail/ Crompton/ Bajaj/ Utkarsh)"
Concrete muffing of existing Tubular / Rail pole with provision of Thermoplastic cable 4 junction box (IP:65) with terminals including MCB SP,6A,B/Cap:10KA-2 nos.(Dimension of JB=200X160X98mm)(Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)
Dismantling of existing Tubular pole / Rail Pole / octagonal pole and concrete foundation , erection of G.I Octagonal Pole along with grouting of supplied 04 Nos. foundation bolts as per Drg. No.- Sr.DEE(G)'s Drg. No. SDAH/G/SS/115 dt. 23.10.09.
"Supply, fixing, connection & commissioning of junction Box made of 14 SWG GI 6 sheet of size 450 mm x 300 mm x 250 mm on AT Mast, consisting with 1 No. MCB DP 63A with G. I. Channel suitable for fixing of MCB, complete with hinged door with locking arrangement. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)"
"Supply, Fixing, connection & commissioning of A.C. Exhaust Fan, 300 mm sweep, 230V, 50 c/s complete with all accessories including fixing with G. I. clamps made of G. I. flat of suitable size & G. I. Nut, Bolts alongwith necessary Masonry works. (Make: Havells/ Usha/ Anchor/ Orient/ Crompton/ Bajaj)"
"Supply, Fixing with suitable G.I clamping arrangement, connection and commissioning of AC Wall Mounting Air Circulator Fan,3 blades, 600mm sweep, 230V, 50c/s complete with all accessories. (Make: Havells/ Usha/ Anchor/ Orient/ Crompton/ Bajaj)"
"Supply & fixing of 16A, MCB protected socket with sheet steel enclosure. (MCB rating taken 6A-16A) (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)"
"Supply, installation, testing, and commissioning of single-phase 8-way MCB distribution board (surface/concealed mounting type), comprising the following components: a) 1 No. 10 Double Pole MCB, 32A, 10kA breaking capacity (incoming) b) 6 Nos. Single Pole MCB, 10A, 10kA breaking capacity (outgoing) Work shall include complete incoming and outgoing wiring terminations, provision of all necessary mounting hardware, accessories, and interconnections, executed as per site conditions and in compliance with IS/IEC standards (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)"
"Supply, installation, testing, and commissioning of 3-phase, 4-way TP&N vertical type distribution board (metal double door enclosure, IP:43 rated), comprising the following 11 components: a) 1 No. MCCB, 4-pole, 50-63A, breaking capacity 25kA b) 12 Nos. MCB, single-pole, 16- 32A, breaking capacity 10kA The distribution board shall be fixed using suitable ISI-marked G.I. fixtures and accessories, complete in all respects as per site conditions and conforming to relevant IS/IEC standards (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)"
"Supply,fixing,testing and commissioning of light control panel with contactor and electro mechanical timer comprising of the following - 1) MCB 32A, Three pole,10KA,415V,50Hz - 1 No., 2) Timer switch- 2 Nos., 3) Power Contactor,3pole,32A - 2 Nos., 4) Toggle switch 6A - 2 Nos., 5) 12 LED Indicators, Indication R,Y,B - 5 Nos. 6) Enclosure made of 14SWG GI sheet fabrication, Panel paint powder coated colour siemens gray and internal wiring with suitable size copper wire etc. (As per Sr.DEE/G/SDAH's drawing number, SDAH/G/1/2024 Dt. 26.02.2024).Fixing should be done by necessary GI fixture and connection with 70%,30% lighting circuit. (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)"
"Supply,fixing and connection of Multi mobile charging point board made of 12mm ply and sunmica size 8inchesX15ichesX3inches with wooden tray for resting mobile phones consisting of 4 nos. piano type switch 6A, 4nos 2-in-1 socket 6A, 01 no LED indicator, 01 no MCB SP 13 10A including internal wiring with 1.5sq.mm copper wire as per General Specification of I.E. Rule.Fixing and connection of mobile charging point board etc should be done with wooden tray by necessary GI fixtures (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/ KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GM Modular/ Legrand/Crabtree/ Havells/Hager) (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)"
"Supply and fixing of multi-plug board for Computer power points with hylam sheet cover consisting of a) Plug Socket 5Pin/6Amp. - 3 nos. b) Piano Switch 6 Amp - 3 nos. c) Plug Socket 6 Pin /16 Amp. - 1 no. d) Piano Switch, 16 Amp - 1 no. e) MCB SP 16Amp,B/cap:10KA. - 1 no. f) LED 14 indication lamp - 1no. including wiring with 2.5 mm2 single core, multi strand, PVC FRLS Cu wire through suitable size (ISI marked) PVC conduit pipe/ casing/ concealed way and along with copper ECC of size 1.5mm2 as per General Specification of I.E. Rule. (PVC Wire Make: Havells/ Gloster/ Polycab/ RR Kabel/ KEI/Mescab) (Switch & Plug Socket Make: Panasonic/ Anchor/ GM Modular/ Legrand/Crabtree/ Havells/Hager) (Switchgear Make: Siemens/ ABB/ Schneider/ Lauritz Knudsen/ Havells/Legrand/ Hager)"
Dismantling of existing damaged Rail Pole/Tubular Pole. Rail Pole/Tubular Pole to be 15 cut by Gas cutter from the least bottom level. Released Rail Pole to be stacked in an isolated area apart from platform. Released Tubular Pole to be deposited to the custody of concerned Sr. SEE (G) by the Firm. Exposed Cables to be cleared or buried in to the ground"
"Supply and installation of GI Standard Earth pipe, 40 mm dia, 2000 mm long, medium gauge complete with provision of Earth pit and there connection with 4 SWG GI wire complete with testing and commissioning, strictly in accordance with relevant IS codes, electrical safety standards.as per Sr. DEE(G)/SDAH's Drg. No. SDAH/G/MISC/47 dt.21.11.2008(Alt-1). (G.I. Pipe Make: TATA/ Jindal / Bansal )"
Supply and installation of G.I. strip of size 25 mm x 3 mm (thick), fixed along walls by 17 grouting suitable size bolts with nuts at 450 mm intervals for earthing, including provision of necessary connections. The G.I. strip shall be separated from the wall using suitable size insulators with the bolts. The work shall be completed with testing and commissioning, strictly in accordance with relevant IS codes, electrical safety standards.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
FormatofGuaranteeBond.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14_07_20221.pdf
ATTACHMENT
GCC-April-2022.pdf
ATTACHMENT
LTHTElectricalBooklet.pdf
ATTACHMENT
2026_03_13AdvanceCorrectionSlipNo_111.pdf
ATTACHMENT
2025_01_09IIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_9ACS-9.pdf
ATTACHMENT
OpenTenderDocument.pdf
ATTACHMENT
Download all tender documents and submit your bid