| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹77.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹92.5 L+₹14.1 L (18.1%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹97.8 L+₹19.5 L (24.9%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹99.8 L+₹21.4 L (27.4%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Reccomended Due to not enlisted in Category b(i) |
Tender Value
₹98.8 L
EMD Value
₹1.7 L
Closing Date
30 Apr 2024, 6:00 pmClosed
CWE (AF) Nagpur
HQ CWE AF NAGPUR VAYUSENA NAGAR, NAGPUR 440007 MILITARY ENGINEER SERVICES
IMPROVEMENT TO AEROLUBE SHED AND WATER PROOFING TREATMENT FOR OTHER STORAGE HANGERS AT 25 ED AF STN DEVLALI
2024_MES_646305_1
80604
Open Tender
Civil Works
Item Rate
365 days
GE (AF) Ojhar
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (AF) OJHAR
₹1.7 L
27 Jun 2024
13 Mar 2024
4 May 2024
13 Mar 2024
30 Apr 2024
16 Apr 2024
Amount
Material and labour for 25 mm thick PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base complete all as specified and directed.
Material and labour for Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate) in rounded or chamfered on edges in channels of rails, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed.
Material and labour for Precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) set in cement mortar 1:4 as in slab for water tank/shelf, landings, cover slabs (for manholes etc) chullah hoods, chajjas, water trough, managers, shelves & similer articles with plane faces complete all as specified and directed.
Supply and fix Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Supply and fix rolled mild steel angle/tubuler/square/rectanguler Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
Material and labour for preparation of new steel surfaces of any description not exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Material and labour for false ceiling work of aluminium snap grid system size 605x605mm for false ceiling with aluminium angles of size 23.5 mmx23.5,,x1.5mm fixed to wall with GI screws and aluminium tee of size 37.5x37.5x1.5mm in main and cross runners fixed 60 cm c/c and tied to existing roof/truss/rafters complete all as specified and directed.
Material and labour for hanging of aluminium false ceiling grid with 3 mm dia GI wire(upto necessary required length & 1.2 Mtr c/c) fixed to slopping roof (rafter/purlin/trusses) complete all as specified and directed.
Material and labour for Non asbestos fibre cement building boards 6 mm thick (one side embosed design), fixed or laid/ inserted to Aluminium grid frame work in ceiling with clips complete all as specified and directed.
Taking down chowkat or frames exe 1.5 sq.m but not exc 4 sq.m each with shutters (without taking of shutter from the frame).
Material and labour for providing ,cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) in roof kerb or mud stops, rounded or chamfered on edges complete all as specified and directed.
Material and labour for 10mm thick bedding layer in CM 1:4 on concrete surfaces (when concrete as green) mixed with WPC @ 3% by weight of cement finished the surfaces fiar and even complete) complete all as specified and directed.
Supplying only liquid water proffing compound.
Material and labour for water proofing with high solids content polyurethene based liquid membrane cold applied coating as per ASTMC 836-89 as under: (a) Surface preparation cleaning the surface and make free of dirt, foregn particle balance followed by grinding all prolusions to make surface modulated thereafter all cracks, construction joints undulation shall be corrected adequetly by standerd procedure with polymer mortar. (b) Priming the surface supply & application of priming coat by diluating original water proofing liquid membrane as per below specification with equal amount of water and mix well, therafter applying the mix @ 400 gm per sqm and allowing it to dry for 4 to 6 hrs (c) Application methology (i) Providing and laying of polyurethene based liquid 1.5UV stable alongwith BTD or equivalent from reputed manufacturer like STP SIKA , BASF @ 1.0 Kg/sqm in first coat amnd applying a layer non woven polyster made Gro textile of 40 gm/sqm or equivalent when the surface is lacky and allowing it to dry completely to form a thickness of 1.15mm DFT finally and shall be tested against any leakage/seepage by water ponding test. complete all as specified and directed. 1. Water proofing works shall be carried out by approved applicator of the manufacturer and shall be gauranteed against any leakage/seepage for a period of minimum 7 years from date of completion of work. 2. Water proofing treatment shall be extended upto minimum 300mm on the verticle surface of parapet/brick work.
Demolition of cement Concrete (unreinforced) in ground floors (below or above ground level) exceeding 15cm thickness and including removing demolished PCC from site exc 500mtr but nexc 1500 mtr depositing where directed.
Excavation in trenches n exc 1.50m wide and nexc 1.50m in depth for foundation shafts , wells, manholes etc n exc 10 sqm on plan and n exc 1.50m in depth and getting out in hard/dense soil, complete all as specified and directed.
Material and labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Material and labour for reinforcement cement concrete M-25 (Design Mix) as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns and basement slabs etc complete all as specified and directed.
Material and labour for einforcement cement concrete M-25 (Design Mix) as in columns, pillars, piers, posts and struts etc complete all as specified and directed.
Material and labour for reinforcement cement concrete M-25 (Design Mix) as in beams, cantilever, bressummeres lintels over 1.50m spam complete all as specified and directed.
Material and labour for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, including flat rough finished surfaces of concrete complete all as specified and directed.
Material and labour for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square , rectanguler or polygonal in shape, including flat rough finished surfaces of concrete complete all as specified and directed.
Material and labour for Formwork to sides and soffits of floor and roof beams, beams haunching. girders, bressummers, lintel and cantilever, shelves including supports over hangs etc rough finished surfaces of concrete (flat) complete all as specified and directed.
Supply and fix Mild steel TMT bars 6 to 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns,(as in stirrups) hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Material and labour for brickwork with fly ash bricks (Old size bricks) straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Material and labour for rendering 15mm thick plaster on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick/stone walls/ concrete surface etc including raking out joints, hacking for key, scrubbing down with water etc all as directed.
Material and labour for rendering 20 mm thick on stone masonry in two layers, with 10mm thick in inner layer over 10mm thick rendering (as in backing course) as first layer on stone masonry surfaces of walls, in cement mortar 1:6 finshed even and smooth (without using extra cement) complete all as specified and directed.
Material and labour for prepariation of new plastered surfaces and applying two coats of distemper oil emulsion over 2mm thick wall care putty on walls complete all as specified and directed.
Material and labour for complete removal of existing treatment and applying two coat of cement base paint over a coat of primer on walls complete all as specified and directed.
Material and labour for repatation of new plastered surface of wall by applying two coats of cement base paint over a coat of primer on walls complete all as specified and directed.
Material and labour for complete removal of existing treatment of walls by steel wire brushing, preparation of surfaces and applying two coats of distemper oil emulsion ovedr the walls after application of JK wall care putty 2mm thick all as specified and directed by engineer in charge. and applying two coat of cement base paint over a coat of primer on walls complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removal of surplus soil to a distance exceeding 250m and n exc 500m and depositing where directed at a level not exceeding and depositing where directed at a level not execeeding 1.5m above the starting point and disposal complete all as specified and directed.
Material and labour for complete removal of existing treatment etc on steel and iron of any description not otherwise described and applying two coats of synthetic enamel paint on steel surfaces including preparing old steel surfaces complete all as specified and directed.
Material and labour for forming contrcation (Dummy) joints 65mmx20mm wide filed with preformed bituminous filler sealing compound Grade -A complete all as specified and directed.
Material and labour for coloured (light shade) vitrified ceramic tiles 10mm thick (Square/rectangular) polished, area of each tiles n. exc 0.36 Sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match and the shade of the tiles including 15mm screed bed or bedding layer CM 1 : 6 complete all as specified and directed.
Material and labour for coloured (light shade) vitrified ceramic tiles 10mm thick (Square/rectangular) polished, area of each tiles n. exc 0.36 Sqm in skirting, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of the tiles including 10 mm thick rendering CM 1 : 4 complete all as specified and directed.
Material and labour for Non Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors set and jointed in neat cement slurry and pointed in coloured cement to match including 15mm screed bed or bedding layer CM 1 : 6 complete all as specified and directed.
Dismantling of stone slab and tiles of any description or thickness in floors, aprons etc laid bedded & pointed in any mortar complete all as specified & directed.
Material and lavour for 20mm thick granite (of any type and any colour) work (table rubbed & polished),in steps, jambs, pillars, window-cill, cooking platforms & like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite,over M & L 15mm thick screed bed or bedding layer in CM 1:4 for laying floor finish including roughning surfaces of old concrete floor by picking ,sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.00 kg per sqm complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Material and labour for glazed coloured (digital/printed/design) ceramic tiles in vertical surface 450 mm x 300 mm x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including 15 mm thick bedding layer/backing coat in CM 1:4 complete all as specified and directed
Taking up or down GI tubing 15mm bore and connections from walls and ceiling or laid in floor including cleaning for refixing or removal to store complete all as specified and directed.
Supply and fix GI tubing 15 mm bore medium grade with all fittings and fixed to wall, ceiling or laid in floor with suitable clamps & nuts etc complete all as specified and directed.
Taking up or down GI tubing 20mm bore and connections from walls and ceiling or laid in floor including cleaning for refixing or removal to store complete all as specified and directed.
Supply and fix GI tubing 20 mm bore medium grade with all fittings and fixed to wall, ceiling or laid in floor with suitable clamps & nuts etc complete all as specified and directed.
Supply and fix in repairs bib taps 15mm bore cast copper alloy chromium plated, fancy type with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Supply and fix in repairs stop valves 15mm bore ,chromium plated, fancy type screwed down, high pressure with crutch or butterfly handle chromium plated fancy type screwed both ends for iron pipe or for unions for 15 mm bore dia of pipe complete all as specified and directed.
Supply and fix in repair low density polythelene pipes 40mm bore fixed complete to walls ,ceiling or in floor complete all as specified and directed.
Supply and fix in repairs wash hand basins, vitreous china (flat back) white of size 550mm X 400mm including cutting for and pinning in ends of brackets or erecting stand including waste fitting, brass chromium plated 32 mm size with long screwed shucks and fly nuts and including PVC discharge pipe complete all as specified and directed.
Supply and fix in repairs waste fittings , brass chromium plated 32mm dia with long screwed shanks and fly nuts fly end bedded in red lead cement and other end fixed complete all as specified and directed.
Supply and fix in repair 15mm bore dia of pipe fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
Supply and fix in repairs vitreous china water closet (Squatting pan) Orisa pattern of size 580x440mm white with integral footrest & 'P; trap (excluding flushing cistern and flush pipe) including connection to trap, to flushing pipe etc complete including PCC for making good to floor etccomplete all as specified and directed.
Supply and fix in repairs PVC low level flushing cistern of syphonic action type 10 ltr capacity fixed to wall with bracket and screwed including PVC flush pipe complete fitting including taking out unserviceable flushing cistern and flush pipe etc complete all as specified and directed.
Supply and fix PVC connections 15mm size with PTMT nuts and PVC washers of length 600mm complete all as specified and directed.
Supply and fix in repairs float valves 20mm bore of high pressure, PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe anfd fixed ccomplete all as specified and directed.
Supply and fix in repairs Grating doom 125mm dia with waste hole of PTMT (minimum weight 50gms) complete all as specified and directed.
Dismantling unserviceable water tank of capacity n exc 500 ltrs complete all as specified and directed.
Supply and fix Rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
Supply and fix in repairs brass chromium plated tubular towel rail, 20 mm dia., D Type, 60 cm long between flanges complete all as specified and directed.
Supply and fix Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
Material and labour for preperation of new steel surfaces of any desciption over 10 cm in width or girth not other wise descibed and applying two coats of synthetic enamell paint over a coat of red oxide complete all as specified and directed.
Supply and fix 5.5mm thick frosted sheet glass ,ordinary quality and glazing with oil putty in squres exc 0.5 sqm in each pane complete all as specified and directed.
Supply and fix Solar control film 50 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
Supply and fix stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Material and labour for powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters and frames of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings complete all as specified and directed.
Supply and fix plain sheet glas 5mm thick tinted, fixed to aluminium doors/windows/ventilators complete all as directed by Engr-in-charge (Note:- Beading/rubber packing is included in the rates for aluminium sections above) complete all as specified and directed.
Material and labour for 12 mm thick prelaminated particle boards, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
Taking down chowkat or frames n exe 1.5 sq.m (without taking of shutter from the frame) complete all as specified and directed.
Material and labour for preparation of old surfaces with complete removal of existing treatment by scrapping down smoke soot, moulds, mass and efflorescent salts and greasy spots etc, and applying two coats of exterior acrylic emulsion of camouflage pattern or pattern approved by Engineer -in-charge over one coat of exterior water based wall priming including provision of scafolding required for the treatment to external surfaces of buildings with required safety measures etc complete all as specified and directed. Note : The work shall be executed stage wise and each stage will be approved by Engr-in-charge. 1. Complete removal of existing treatment. 2. Priming with exterior wall based wall primer.
Supply and fix pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.6 mm thick of an colour having tensile strength of 550 Mpa as in roof covering to wall fixed with self tapping screws complete all as specified and directed.
Dismantling of 150mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortar complete all as specified and directed.
Supply and fix 150mm dia cast iron rain water pipes with cement joints with ears, all accessories ,clamps and fixing with existing valley gutter after cutting the valley gutter sheets and provisioning funneling system to pass the roof rain water through this down take pipe to the existing drains at any hieght any description etc complete all as specified and directed.
All as per item No 75 here in above but as in reffixing of 150mm di CI pipe complete all as specified and directed.
Supply and application of two coats solvent based solar IR Heat Reflective Coating system for undamaged, rust free coated metal surfaces confirming to BIS STD IS 17218:2019 on existing galvalume sheet/Galvanised corrugated sheet to reduce the temperature as well as increasing life of existing sheets with thorough surface preparation to remove dust ,dirt, moulds etc followed by 2 coats application of Thermocool 0.3M , 2 component ,PU based UV resistant, Non- yellowing, solar IR Heat reflective coating with pull off adhesion 3.25 Sqm/Ltr/2 coat (total dft 100-200 microns) and must have been tested at NABL certified Lab with a minimum service lie of 8 years complete all as specified and directed.
Supply and fix Sub main wiring of copper conductor, single core multi stranded PVC insulated 1100 Volts FRLSH grade 2 run single core 1.5 Sq.mm cable and one run of 1.5 Sqmm copper earth wire for continuous earth fixed on wall/ceiling/floor etc. drawn in stove enammeled metallic conduit complete all as specified and directed.
Supply and fix Sub main wiring of copper conductor, single core multi stranded PVC insulated 1100 Volts FRLSH grade 2 run single core 2.5 Sq.mm cable and one run of 2.5 Sqmm copper earth wire for continuous earth fixed on wall/ceiling/floor etc. drawn in stove enammeled metallic conduit complete all as specified and directed.
Supply and fix Sub main wiring of copper conductor, single core multi stranded PVC insulated 1100 Volts FRLSH grade 2 run single core 4.0 Sq.mm cable and one run of 4 Sqmm copper earth wire for continuous earth fixed on wall/ceiling/floor etc. drawn in stove enammeled metallic conduit complete all as specified and directed.
Supply & fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Supply & fix flame proof exhaust fan 380 mm (15") sweep1440 RPM 230 V including all fixing arrangement, wall cutting and cement work complete all as specified and directed.
Supply & fix flame proof weather proof 90 W LED flood light fittings including necessary fixing arrangements and connections complete all as specified and directed.
Supply and fix flame proof weather proof distribution board 8 way with and including MCB 2P, 32 A 01 and Outgoing 1 P , 6 A- 06 Nos with complete internal busbar and wiring upto terminals complete all as specified and directed.
Taking down carefully aluminium/copper sub main wiring on TW batten/PVC casing capping, surface steel/PVC conduit including all fitting/fixtures and making good disturbed surfaces of wall/floor/ceiling etc to match the adjoining surfaces.
Taking down carefully LED focus fitting/fixtures any type and making good disturbed surfaces of wall/floor/ceiling etc to match the adjoining surfaces.
Taking down carefully exhaust fan any type and making good disturbed surfaces of wall/floor/ceiling etc to match the adjoining surfaces. Exhaust fan to be deposit to MES store yard
Taking down carefully old DB and MCB s any type and making good disturbed surfaces of wall/floor/ceiling etc to match the adjoining surfaces and depositing in MES store.
Material and labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI strip 25 x 4 mm dia through GI pipe 32 mm dia light grade by means of bolts,nuts, check nuts and washers of galvanised iron or steel,with adequate quantity of charcoal and salt, proper watering arrangements including 20 mm dia medium grade GI tubing.PCC chamber,Chamber Cover all as shown in electrical plate no 3of SSr part I 2009 connected to earthing test point all as specified or indicated and testing on completion. The end point connection of eatrhing will be carried out with the help of GI bolt grouted and washer and nut complete all as specified and directed.
Material and labour for Shifting of existing sheet metal enclosures Distribution board 415 volt, Vertical TPN 8 way with provision for DPx160 series MCCB of legrand make or equivalent in L&T as incomer and SP/TP MCB's as outgoing as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface/reccess mountingIP-43 IK-09 protection with the following complete all as specified and directed.:- (i) MCCB DPx160 series thermal magnetic, 25 KA rupturing capacity,125A, 4 pole as incomer-01 Nos (ii) MCB SP 6 to 32 Amp,10 KA - 10 Nos
Supply & fix flameproof weather proof plug in switch socket 16 A , 3 pin ( 2P + E) complete all as specified and directed.
Supply & fix flameproof weather proof ceiling fan 1200 mm (48") sweep1440 RPM 230 V including flameproof regulator, all fixing arrangement, wall cutting and cement work complete all as specified and directed.
Supply and fixing flameproof weather proof LED tube light fitting 1x 20 Watt, 4 feet , CMRI certified P 65 protection with die cast aluminum hosing with heat resistanttoug hened glass with LED tube light fixtures driver,holders, connector etc.Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
Material and labaur for point wiring complete with two single core, PVC insulated, unsheathed, multi stranded bright annealed copper conductor cable, 1.5 Sq.mm 1100 Volts, FRLS grade drawn through and including heavy duty PVC casing and capping not less than 25 mm width and accessories surface mounted on walls, ceilings etc. on & including PVC box and plate for mounting switches, sockets, regulators etc and one run of 1.5 Sq.mm PVC insulated, unsheathed, multistranded, copper conductor cable FRLS grade as earth wire and connected to common earth dully complete all as specified and directed for the following :-
One light/fan point controlled by one switch
One 3 pin socket out let 5 Amps on same board.
One 3 pin socket out let 5 Amps on independent board.
One bell point controlled by one bell push
Ditto- all as per Sl item No 94 above but with two runs of 2.5 Sq.mm cable and one run of 2.5 Sq.mm cable as earth wire for one 3 pin socket outlet/power point 15 Amps controlled by one switch complete all as specified and directed.
Supply and fix in repairs Switch piano flush type single pole one way 5 Amp complete all as specified and directed.
Supply and fix in repairs switch piano flush type single pole one way 15 Amp complete all as specified and directed.
Supply and fix in repairs Bell push flush type 5 Amps complete all as specified and directed.
Supply and fix in repairs Bell, Ding Dong AC 230 Volts single pole complete all as specified and directed.
Supply and fix in repairs Socket out let 2 in 1, 5 pin 5 Amps flush type complete all as specified and directed.
Supply and fix in repairs Socket out let 2in1,3 pin 5 and 15 Amps flush type complete all as specified and directed.
Supply and fix in repairs Lamp holder PVC/polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed.
Supply and fix in repairs Ceiling rose surface type, PVC/Polycarbonate isulated body size 50x28 mm two to three terminals complete all as specified and directed.
Supply and fix in repairs Fan regulator electronic step type 5 step suitable for 1200/1400 mm sweep complete all as specified and directed.
Supply and fix in repair Sheet metal enclosure for DB’s with bus bar ,MCB SPN 8way ,240 volts double door with detachable gland platecomplete all as specified and directed.
Supply and fix MCB SP 6-32 Amp single phase 240 volts including making connection complete all as specified and directed.
Supply and fix MCB SPN 6-32 Amp single phase 240 volts including making connection complete all as specified and directed.
Supply & fix in decorative ultra slim square profile LED light fittinh minimum rating 20 W lighting fixture with aluminium housing atd intergrsted LED driver, energy efficient ready to use pack 20W LED 6000K, complete all as specified and directed. Make: Havells cat Part No Lumiline+BS20WLED840SPCSS or equivalent in Philips/Bajaj/CG/Wipro.
Taking down and Hanging only ceiling fans of any make and sweep connecting the complete with & including provision of copper conductor cord 3 core PVC insulated and sheathed from ceiling rose to fan connector and testing as directed and specified( Note: The fan shall be fitted with new set of clamps, rubber shackle split pins and top and bottom nut bolts etc complete all as specified and directed.
Supply & fix ventilating fan made out of high quality engineering plastic, resistant to colour change with anti static properties, 250mm sweep suitable to work on 230 Volts 50 Hz AC supply of Havells or equivalent of CG/Bajaj including connecting to ceiling rose complete all as specified and directed.
Material and labour for insulator porcelain/ polycarbonate with suitable fixing arrangements for roof and down conductor duly insulated from wall surface/ roof complete all as specified and as directed .
Material and labour for fixing air termination, single pointed aluminium rod 12mm dia and 300 mm long complete all as specified and as directed .
Material and labour for aluminium strip 25x3.15 mm with saddles and fixing screws etc for roof and down conductor isolated from building above ground level all as specified and as directed .
Material and labour for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25 mm long hex head screw complete all as specified and directed .
Supply and fix medium grade GI tube 20mm dia after cutting in to required length for fixing air termination including fixing arrangements all as specified and directed .
Material and labour for fixing arrangements for GI tube using PCC 1:3:6 C1 (20 mm graded aggregate) all as specified and directed .
nd labour inrepairs for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI strip 25x4 mm through GI pipe of suitable dia light grade by means of bolts,nuts, check nuts and washers of galvanised iron or steel,with adequate quantity of charcoal and salt, proper watering arrangements including 20 mm dia medium grade GI tubing.PCC chamber,Chamber Cover all as shown in electrical plate no 3of SSr part I 2009 connected to earthing test point all as specified or indicated and testing on completion. The end point connection of eatrhing will be carried out with the help of GI bolt grouted and washer and nut complete all as specified and directed.
Supply & fix aluminium strip 25x3.15 mm burried under ground through GI pipe of 40mm dia light grade with fittings like bend elbow etc including connecting with nuts, bolts, washers etc complete all as specified and directed.
Supply and fixing flameproof weather proof LED panel light fitting 1x30 watt flame proof, CMRI certified complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
taking down carefully aluminium/copper point wiring (light, fan, Socket power etc) on TW batten / PVC casing capping, surface steel/ PVC conduit including all fitting/ fixtures and making good distrubed surfaces of wall/floor/ceiling etc to match the adjoining surfaces complete all as specified and directed.
Note : The amount against Schedule of Credit on Page No. 42 shall be deducted from the total amount quoted against Sch 'A' while deriving item rate for Acceptance.
Vinod Enterprises
MAHIMA CONSTRUCTION
shubham Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .