| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹14.9 L+₹2.0 L (15.7%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹15.4 L+₹2.5 L (19.5%)Rejected-Finance | L3 | Rejected-Finance In order but L3 | |
| 4 | L4₹15.8 L+₹2.9 L (22.9%)Rejected-Finance | L4 | Rejected-Finance In order but L4 | |
| 5 | L5₹16.6 L+₹3.7 L (28.7%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L5 | Rejected-Finance In order but L5 |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
15 Jun 2023, 6:00 pmClosed
GE(U) E/M Meerut
Roorkee road Meerut Cantt
REPAIR TO LED STREET LIGHTS ALONG WITH REPLACEMENT OF LT DAMAGED CABLE INCLUDING ALLIED ITEMS AND UPGRADATION OF STREETLIGHT SYSTEM IN BHAGAT LINE AREA UNDER AGE E/M (ES) AT GE (U) E/M MEERUT CANTT.
2023_MES_598241_1
8508/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE(U) E/M Meerut
₹46,000
Yes
30 Jun 2023
25 May 2023
17 Jun 2023
25 May 2023
15 Jun 2023
8 Jun 2023
Amount
Preventing/servicing unserviceable LED Street light/flood light fitting, 45 to 210 watts any type from pole/wall to checking out serviceability of parts/circuit such as drivers, PCB etc if necessary taking down the fittings and repair of unserviceable parts,including soldering with existing circuit board, replacing with new of aluminium wire of 1.5 Sqmm 3 core upto 1.5 mtr and reassembling and refixing in same position including connecting, testing complete all as specified and directed.
Taking down existing street light fitting of any wattage and size all as directed.
Material and labour for replacement of existing unsv street light fittings with LED street light fitting 60 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses and Driver shall be IP-67 for water protection, including surge protection device 4 Kv including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed.
Material and labour for replacement of existing unsv street light fittings with LED street light fitting 70 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses and Driver shall be IP-67 for water protection, including surge protection device 4 Kv including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed.
M & L in replacement UNSV GI bracket made out of GI pipe 40 mm bore medium grade bent to required shape of 1.2 mtr long and fixing to pole/wall with suitable size of nut, bolts and clamps all as spd and directed.
Material and labour for replacement of existing unsv street light fittings with LED flood light fitting 120 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 Kv and Driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed.
S&F in repair of highmast light luminaire flood light, pressure die cast aluminium housing, IP-66 protection, 200 Watt / 210 Watt flood light with and including high power SMD LED lamps with inbuilt surge protection with SPD 10 KV and connecting with and including 2.5 Sqmm, 3 core copper conductor cable from box to connector of light fitting, complete all as specified and directed.Note (i) The driver should be polted anti vibration type, IP 66 should be sustain 440 Volts for 2-4 hrs. (ii) LM-79 and LM-80 test report with 50000 burning hrs LED life from NABL lab shall be provided. (iii) Systems lumon efficiency shall be 110 lumon/watt,
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any type of soil complete all as specified and directed.
Returning filling o;f soil in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil.
Removing surplus excavated material soil from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point.
M & L for local sand coushioning with dry and clean sand over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and punned down complete all as directed
M&L fly ash old size bricks,straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cable for protection all as specified.
M & L for boring in any type of soil under road 1.5 Mtr below the top surface of road by convential method complete for passing through 40mm to 100mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed. NOTE :- Pipe will be measured and paid for separately. Any damage to existing cables of any type and road will made good by the tenderer without any extra payment.
Labour for Re-laying of old serviceable bricks item retreived from Sl No. 8 here-in before for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable all as directed.
M&L Taking down and after finding faults in cable Re-Laying XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 10 to 25 Sqmm 4 Core (Item retreived from SI No.8 here-in-before) laid in trenches or fixed on wall/floor/poles after removing fault complete all as specified and directed.
Supply and Laying including taking down of old unserviceable XLPE LT UG cable PVC insulated,bedded armoured heavy duty electric cable 1100volt grade with aluminium conductor of size of cable 25 Sqmm 4 Core complete all as spd and directed. Make:-Havells,Glostar,Grandlay
All as per Srl No 15 here-in-before but size of cable 16 Sqmm, 4 Core complete all as spd and directed. Make:-Havells,Glostar,Grandlay
All as per item No 15 here in before but size 10 Sqmm 4 core complete all as spd and directed. Make:-Havells,Glostar,Grandlay
All as per item No 15 here in before but size 10 Sqmm 2 core complete all as spd and directed. Make:-Havells,Glostar,Grandlay
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor, along the wall or along the pole, including taking down complete all as specified and directed .
Scraping, cleaning and preparation of old surfeces of steel tubular pole (9 Mtr long) steel fitting complete and M&L for preparation of old painted surfaces of erected steel tubular swaged poles / Rails/Girder poles of LT over head line (Except embedded portion), 9 M long including all MS work mounted on pole, earth protection & water pipe ( if exists) and providing one coat of aluminium paint and providing 05 Nos bands/ straps with two coats of Retro Reflective paint ( black, green and red 20 cm wide each) from top of plinth block and numbering of poles with white Retro Reflective paint on yellow Retro Reflective piant ground (50mm wide and 100mm high letters) including encircling the letters or figures complete all as specified
Supply and fix in repair including taking down pole mounting type junction box factory made of size 300x200x105 mm of FRP sheet, shockproof and rustproof, fire retardant as per IS:11731 with front openable hinged door, locking arrangement with 4 Nos aluminium bus bar 40 Amp rating mounted on porcelain insulator, cable gland, lugs consisting DIN type rails for fixing MCB SP 6 Amps, 10 KA, including mild steel flat iron clamp made out of 40x4 mm FI and nut, bolts & washers duly painted clamps, nuts and bolts with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. (Note:-Rate of MCB shall be included in the quoted unit rate)
Supply and fix in repair including taking down pole mounting type junction box factory made of size 200x140x95 mm of FRP sheet, shockproof and rustproof, fire retardant as per IS:11731 with front openable hinged door, locking arrangement with 2 Nos aluminium bus bar 40 Amp rating mounted on porcelain insulator, cable gland, lugs consisting DIN type rails for fixing MCB SP 6 Amps, 10 KA, including mild steel flat iron clamp made out of 40x4 mm FI and nut,bolts & washers duly painted clamps, nuts and bolts with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. (Note:-Rate of MCB shall be included in the quoted unit rate)
Supply, fixing, in replacement installation and testing including taking down LT panel out door (Kiosk type) type, wheather & vermin proof MS sheet housing 3.15mm thick, double door front & rear openable type mounted on 50 X 50 X 6mm angle iron frame, floor mounted type with coloured horizontal Tinned aluminium bus bar 4 pole mounted on insulators of rating 200 Amps, one MCCB, 4 pole 100 Amps, 25 KA 415 volts at incoming supply. The panel size not less than 600x450x300mm with cable gland, duly powder coated, locking arrengement complete and including grouting in PCC block of suitable size all as directed by Engr-in-Charge.
Supply and fix in replacement including taking downsheet metal busbar chamber for multiple Nos of service connection made out of 2mm thick CRCA sheet powder coated suitable for pole mounted outdoor type complete with 04 pole aluminium colour code busbar, 200 Amp rating, 30cm long horizontal type installed on porcelain insulators including fixing on pole FI clamp 40mmx4mm with nuts, bolts and washers complete all as specified and directed.
Taking down of old earthing material and material and labour for Earthing complete with galvanised MS earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected g, soldered and revetted to earth platealvanised earth lead wire 4.0mm dia by means of bolts, nuts , check nuts and washers of galvanised iron or steel. GI earth wire will be protected by using 40mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I.
Taking down old u/s copper cable and Supply and fix fire retardant low smoke (FRLS) PVC insulated unsheathed multi stranded three core copper conductor 1100 volts grade of size 1.5 Sqmm cable complete all as specified
Taking down old u/s pvc conduit and S&F 20mm external dia rigid non metallic PVC conduit, medium grade including required fittings and fixing accessories such couplers, lock nuts, saddles, pipe hook, etc fixed to poles with suitable size clamps (3 Nos) with nut & bolts complete all as specified.
Taking down old u/s timer switch and Supply and fixing of nature switch complete with timer , contactor, relays and suitable rating MCBs for incoming and out going in built in suitable IP 66 enclosure of three phase integrated models of capacity 8 KW complete all as specified and directed. Make : Cat Part No. SWADEEP-66, 8kW 3P of Healer Enterprises or equivalent
Taking down old u/s MCB and S & F i MCB single pole 240 volts, 'c' curv of rating from 6 to 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables. Make:- Legrand / Schenieder/ Seimens
M/S Ex Soldiers Mechanical Works
NITHYA INFRATECH
D S Enterprises
Shikha Enterprises
M/S Konark Electric Sales Corporation
Narender Construction
automation and switchgear control
Natwadia Electrical Company
Ramesh Traders Govt Contractors & General OrderSuppliers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .