| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAdmitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | L1 | Admitted-Finance | |
| 2 | L2₹8.3 L+₹42,687.68 (5.46%)Admitted-Finance PROP NO A 80 FIRST FLOOR FLAT NO 3 CHATTAR PUR ENCLAVE PHASE 2 NEW DELHI SOUTH WEST DELHI DELHI 110074 | SOUTH DELHI | DELHI | 110074 | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Premier Engineering Company L1 | M G Traders and Engineers L2 |
|---|---|---|---|---|---|
| 1.01 | Disconnection from LT panel taking out the installed A.C.B from the panel, removing defective parts of A.C.B. & from the metering section of Panel. | 7 | Job | 10,500 ₹12,390 Lowest | 11,550 ₹13,629 |
| 1.02 | Air circuit breaker 800 Amp. 50 ka 3 Pole MDO 415V microprocessor release. Make: L&T | 1 | No | 1,71,200 ₹2,02,016 Lowest | 1,75,300 ₹2,06,854 |
| 1.03 | MCB Single pole 6Amp. Make L&T | 3 | No | 684 ₹807.12 Lowest | 750 ₹885 |
| 1.04 | Under voltage trip unit. Make: L&T | 7 | No | 31,850 ₹37,583 Lowest | 32,550 ₹38,409 |
| 1.05 | Digital Amp. Meter. Make L&T | 7 | No | 7,840 ₹9,251.2 Lowest | 8,470 ₹9,994.6 |
| 1.06 | Digital Volt Meter 0-500V. Make L&T | 2 | No | 2,240 ₹2,643.2 Lowest | 2,420 ₹2,855.6 |
| 1.07 | Arcing contact. Make: L&T | 12 | No | 57,000 ₹67,260 Lowest | 60,000 ₹70,800 |
| 1.08 | Indicating lights LED type RYB & On/off. Make : L&T | 10 | No | 2,100 ₹2,478 Lowest | 2,500 ₹2,950 |
| 1.09 | Motor protection relay. Make L&T | 5 | No | 1,29,900 ₹1,53,282 Lowest | 1,42,500 ₹1,68,150 |
| 1.10 | Making of outgoing/incoming bus bar links for main & cable connection duly sleeve with heat shrinkable PVC sleeve. | 1 | Set | 14,250 ₹16,815 Lowest | 15,500 ₹18,290 |
Tender Value
Refer Docs
EMD Value
₹16,200
Closing Date
10 Oct 2025, 3:00 pmClosed
EXECUTIVE ENGINEER (SDW) IX
RITHALA STP SEC-11 ROHINI DELHI-110085
Repair and Renovation of LandT make LT panel board installed at Avantika SPS.
2025_DJB_279170_7
NITNo5 SDWIX
Open Tender
Miscellaneous Works
Works
60 days
RITHALA STP SEC-11 ROHINI DELHI-110085
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJB SABpaisa
₹16,200
23 Oct 2025
3 Oct 2025
10 Oct 2025
3 Oct 2025
10 Oct 2025
3 Oct 2025
Disconnection from LT panel taking out the installed A.C.B from the panel, removing defective parts of A.C.B. & from the metering section of Panel.
Air circuit breaker 800 Amp. 50 ka 3 Pole MDO 415V microprocessor release. Make: L&T
MCB Single pole 6Amp. Make L&T
Under voltage trip unit. Make: L&T
Digital Amp. Meter. Make L&T
Digital Volt Meter 0-500V. Make L&T
Arcing contact. Make: L&T
Indicating lights LED type RYB & On/off. Make : L&T
Motor protection relay. Make L&T
Making of outgoing/incoming bus bar links for main & cable connection duly sleeve with heat shrinkable PVC sleeve.
Retrofitting of ACB (800A, 3 Pole) as above in existing panel by carrying out following works :- 1) • Supply of necessary hardware, supports etc. 2) • Making /supply of M.S angle base frame/supports of size as suitable to the mounting of new ACB. Fixing of the same at the panel chamber with the help of nuts bolts /welding etc. as suitable for installation of new ACB /their cradles. 3) • Dismantling the existing circuit breaker from the chambers of the LT panel including its cradles and disconnecting the bus bar connections with the main bus bars, disconnecting the outgoing cables etc. 4) Installation of new ACB cradle in the panel by the help of nuts bolts etc in proper alignment for connecting the bus bars. Fixing the ACB in the cradles in the proper condition including checking the movement. Making control wiring connections for the ACBs. 5) • Connecting the main bus bars to the incoming sides of the ACB by re-arrangement /modification/addition of bus bar lengths in Aluminum construction for retrofitting of ACB. 6) making a new M.S. door or modification in 2 mm CRCA Sheet, powder coated as suitable size to match symmetry, Connecting the bus bar at the outgoing side of the ACB by re-arrangement/ modification/addition of bus bar lengths in Aluminum for retrofitting of ACB.
Calibration of Protection relays having sensitive earth fault, over current, S/C protection with following features - High set elements, highly immune to harmonics, both 1A & 5A CT input in one relay, 6 output contacts. Make: L&T
Cleaning of complete ACB of installed as incomer & Bus coupler. in panel 2000 Amp., removal of old grease and re-greasing of all movable parts with recommended grease, setting of tripping mechanism, re-wiring of under voltage coil, complete servicing of ACB Fixing of components in place of defective components as required complete with control wiring & re-installation of A.C.B. in existing LT Panel complete with all incoming & outgoing cable connection with thimbling
Cleaning of complete ACB of installed as outgoing feeder in panel 800 Amp., removal of old grease and re-greasing of all movable parts with recommended grease, setting of tripping mechanism, re-wiring of under voltage coil, complete servicing of ACB Fixing of components in place of defective components as required complete with control wiring, & re-installation of A.C.B. in existing LT panel complete with all incoming & outgoing cable connection with thimbling.
Fixing of Ampere Meter, indicating lights, under voltage, relay etc., complete with wiring etc.
Testing & commissioning of panel & allied accessories as per required parameters with relevant IS .Testing of the panel prior to switching on as follow i) Continuity and earth testing ii) Meggaring of all equipment for phase to phase, neutral to body, neutral to earth and phase to earth.
M G Traders and Engineers (BID ID -1629173)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .