Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.3 LAccepted-Finance AT KHANDBARA POST KUNTAMODI TAL DHADGAON DIST NANDURBAR 425414 | DHADGAON | NANDURBAR | MAHARASHTRA | 425414 | ₹54.3 L | L1 | Accepted-Finance Accept |
| 2 | L2₹54.8 LAccepted-Finance AT POST LONDHARE TAL SHAHADA DIST NANDURBAR 425409 | NANDURBAR | MAHARASHTRA | 425409 | ₹54.8 L | L2 | Accepted-Finance Accept |
| 3 | L3₹55.4 LAccepted-Finance NA | NA | NA | 121004 | ₹55.4 L | L3 | Accepted-Finance Accept |
Tender Value
₹54.3 L
EMD Value
₹55,000
Closing Date
29 Jan 2026, 10:00 amClosed
EE
ZP Nandurbar
Construction of Additional Class Room 5 Building at Dhadgoan Tal Dhadgoan Dist Nandurbar
2026_NANDU_1271164_1
ETN - 04/ 2025-2026
Open Tender
Civil Works
120 days
Nandurbar
As Per Tender Notice
2 documents required · 2 mandatory
₹2,000
₹55,000
27 Mar 2026
23 Jan 2026
30 Jan 2026
23 Jan 2026
29 Jan 2026
23 Jan 2026
Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area .
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete.
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
FIRST FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
FIRST FLOOR
Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
FIRST FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
FIRST FLOOR
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
FIRST FLOOR
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
FIRST FLOOR
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete.
FIRST FLOOR
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.
FIRST FLOOR
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
FIRST FLOOR
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
FIRST FLOOR
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.
FIRST FLOOR
Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm .
FIRST FLOOR
Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
FIRST FLOOR
Providing and fixing steel window C.R.C. sheet as per I.S. 1513 : 1986. gauge sect. 65 x 40 x 25 mm shutter single sheet of 24 gauge single leaf joined by fusion welding at appropriate points with vertical grooves of 15 mm wide and 15 mm deep at a distance of 45 mm. The first and last rib should be 60 mm away from vertical edge of the shutter. the shutter shall be welded, with angle to from the periphery of the shutter. At the center of the frame there shall be angle welded to bifurcate the frame into segments with two leaf shutter square 12 mm square guard bars at 120 mm center with all accessories
FIRST FLOOR
Providing and fixing mild steel grill railing weighing 15Kilogram/ One Square Metre. with teak wood hand rail of size 75mm.x 60mm. and sill 75mm.x 25mm.and posts for verandah including fabricating, fixtures, erecting and painting the grill work with one coat of anticorrosive paint and two coats of oil paint and polishing the grill, hand rail with French polish. Spec. One Number : Bd.U.3
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete.
FIRST FLOOR
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.
FIRST FLOOR
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.
FIRST FLOOR
Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to new plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.
FIRST FLOOR
a) Fine Modulus (Sieve Analysis), Silt and Clay Content
b) Silt Factor
a) Water absorption
b) Sieve Analysis
c) Abrasion Value
d) Flakiness index & Elongation index
f) Soundness
L) Gradation plastory index
m) P. I. Value
a)Standard consistancy Fineness, Specific Gravity, Setting (Initial and Final), Compressive Strength
a) Compressive Strength ( Kg per Square meter)
a) Upto 16 milimeter (Set of 3 Bars) 1 Test 1200.00
a) Crushing Value, Water absorption, Effloresences
Royalty Charges For Sand
Royalty Charges For Other Minerals
Point wiring in PVC trucking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wier,flush type switch,earthing and required accessories as per specification No.WG-PW/SW.
Wiring for plug on bord with flush Switch socket,copper wiring and earthing as per specification No: WG-PW/SW.
Suppling & erecting 5W-7W,230V integral type LED Lamp suitable for B-22/E-27 base.
Suppling and erecting flush type shockproof plug socket 6A & 16A (6 pin) with 16A switch combined with indicator lamp and fuse with gang box on wooden bord.
Suppling & erecting ready to use retrofit T8 LED 18/20 tube light with polycarbonate bodyh, heat sink, interated HF elctronic driver compatible to T8 /T12 LED luminaire by disconnecting starter & ballast if necessary.
Suppling and erecting enrgy saving ceilling fan 230 V A.C. 50 cycles 1200 mm complet erected in [position as per specification no. FG-FN/CF.
Suppling and erecting 'B' class G.I. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 Sq.mm copper PVC wire.
Suppling and erecting electronic type step regulator for ceilling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board.
Suppling, erecting & marking SPMCP 6A to 32A, B-series with rated short-circuit breaking capacity (lcn)10kA in provided distribution board as per specification no. SW-SWR/MCB.
Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Suppling and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outing SP MCBs, with door, 1.2 mm thickness surface / flush mounted, IP 43 Protection on iron / GI Frame as per Specification no. SW-SWR/MCBDB.
Suppling and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking / inside pole / Bus bars or anyother places as per specification No. WG-MA/BW.
Suppling and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking / inside pole / Bus bars or anyother places as per specification No. WG-MA/BW.
Suppling and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking / inside pole / Bus bars or anyother places as per specification No. WG-MA/BW.
Suppling and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit / trunking / inside pole / Bus bars or anyother places as per specification No. WG-MA/BW.
Providing pipe type earthing with 40mm dia. G.I. pipe or 20 mm dia. G.I. road complete with all materials testing and recording the results as per specification no. EA-EP.
Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting street light Wall bracket made from 25 mm. dia.G.I.pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.86 MB
B1.pdf
Tender Documents • 1.50 MB
BOQ_2188724.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid