Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.3 LAccepted-AOC | L1 | Accepted-AOC Work Order Issued | |
| 2 | L2₹54.3 L+₹2,000 (0.04%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹54.3 L
EMD Value
₹1.1 L
Closing Date
30 Nov 2023, 2:00 pmClosed
EE, PWD(B AND NH), UB Dist. Territorial Bldg Div
O/O The EE, PWD(B AND NH), UB Dist. Territorial Bldg Div
Construction of Staff Quarter at Naokata MPHC in Baksa District under Health deptt. BTC for the year 2023-24
2023_PWBNH_34206_3
TECH/U_BDTD/BLDG/IFB/2023-24/4 Dated.21.11.2023
Open Tender
Civil Works - Building
Item Rate
300 days
Baksa
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹1.1 L
Yes
14 Mar 2024
24 Nov 2023
4 Dec 2023
24 Nov 2023
30 Nov 2023
24 Nov 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.1 Mild steel and Medium Tensile steel bars
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.1 Mild steel and Medium Tensile steel bars
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.3 Suspended floors, roofs, landings, balconies and accessplatform sqm 766.55
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand).
Steel work in built up tubular (round, square or ractangular hollow tubes etc) trusses ets. Including cutting, hoisting, fiaxing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washer etc. complete Hot finished welded type tubes
12.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.2 0.80 mm thick with zinc coating not less than 275 gm/m²
12.4 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 12.4.1 0.80 mm thick with zinc coating not less than 275 gm/m² metre
12 mm cement plaster of mix : 13.4.2 1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.2 1:6 (1 cement: 6 coarse sand)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of Tile 600x600 mm
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete. sqm 1063.45
11.5 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.3 Kiln seasoned and chemically treated hollock wood.
9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1.2 30 mm thick shutters sqm
9.3 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. 9.3.2 Kiln seasoned and chemically treated hollock wood
12.25 Providing and fixing flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS: 3087 marked, in ceiling with necessary nails etc. complete (frame work to be paid separately): 12.25.1 12 mm thick
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth. .
13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.2 Painting wood work with Deluxe Multi Surface Paint ofrequired shade. Two or more coat applied @ 0.90 ltr/10sqm over an under coat of primer applied @0.75 ltr/10sqm of approved brand and manufacture.
13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
13.44 Finishing walls with water proofing cement paint of required shade : 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
Providing and fixing ISI marked oxidised MS sliding door bolt with nuts and screws etc. completed: 250x16mm
Providing and fixing ISI marked oxidised MS sliding tower bolt black finished (Barrel type) with nuts and screws etc. completed: 200x10mm
Providing and fixing ISI marked oxidised MS handles conforming to IS: 4992 with necessary screws ctc. Complete. 125mm
Dismentling roofing including ridges, hips valleys and gutter etc. and stacking the materials within 50 metre lead of:
15.18 Dismantling steel work in built up sections in angles, tees, flats andchannels including all gusset plates, bolts, nuts, cutting rivets, weldingetc. including dismembering and stacking within 50 metres lead.
15.2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix)
15.12 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.2 Of area beyond 3 sq. metres each 414.55
10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
12.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.2 0.80 mm thick with zinc coating not less than 275 gm/m²
Providing ridges or hips of width 60 cm overall width plain GS sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia. GI limpet and bitumen washer complete 0.63 mm thick with zinc coating not less than 275 gm/m2
Providing wood work in frames of doors, windows, clearstory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or with dash fasteners shall be paid separately) kiln seasoned and chemically treated hollock wood
Providing wood work in frames of false ceilling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.
Providing and fixing panelled or panelled and glazed shutter for doors, windows and clearstoey windows fixed with butt hinges of required size with necessary screws, excluding pannelleding which will be paiid for separately, all complete as per direction of Engineer-in-charge (Butt hinges and necessary sdrews shall be paid separately) kiln seasoned and chemically treated hollock wood 35mm thick shutter
Providing and fixing insulating board ceilling of approved quality with necessary nails etc. complete (frame work to be paid separately) Natural colour insulating board ( 12mm tk.
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of Tile 600x600 mm
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth. .
INTERIOR Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : .New work (two or more coats) over and including waterthinnable priming coat with cement primer .Interior walls
EXTERIOR Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinnable cement primer
EXTERIOR Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqmover and including one coat of Special primer applied @0.75 ltr /10 sqm
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
Providing and fixing ISI marked oxidised MS sliding door bolt with nuts and screws etc. completed:250x16mm
Providing and fixing ISI marked oxidised MS sliding tower bolt black finished (Barrel type) with nuts and screws etc. completed: 200x10mm
Providing and fixing ISI marked oxidised MS handles conforming to IS: 4992 with necessary screws ctc. Complete. 125mm
Dismentling roofing including ridges, hips valleys and gutter etc. and stacking the materials within 50 metre lead of:
15.18 Dismantling steel work in built up sections in angles, tees, flats andchannels including all gusset plates, bolts, nuts, cutting rivets, weldingetc. including dismembering and stacking within 50 metres lead.
15.2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix)
15.12 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.2 Of area beyond 3 sq. metres each 414.55
10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
12.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.2 0.80 mm thick with zinc coating not less than 275 gm/m²
Providing ridges or hips of width 60 cm overall width plain GS sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia. GI limpet and bitumen washer complete 0.63 mm thick with zinc coating not less than 275 gm/m2
Providing wood work in frames of doors, windows, clearstory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or with dash fasteners shall be paid separately) kiln seasoned and chemically treated hollock wood
Providing wood work in frames of false ceilling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.
Providing and fixing panelled or panelled and glazed shutter for doors, windows and clearstoey windows fixed with butt hinges of required size with necessary screws, excluding pannelleding which will be paiid for separately, all complete as per direction of Engineer-in-charge (Butt hinges and necessary sdrews shall be paid separately) kiln seasoned and chemically treated hollock wood 35mm thick shutter
Providing and fixing insulating board ceilling of approved quality with necessary nails etc. complete (frame work to be paid separately) Natural colour insulating board ( 12mm tk.
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of Tile 600x600 mm
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth. .
INTERIOR Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : .New work (two or more coats) over and including waterthinnable priming coat with cement primer .Interior walls
EXTERIOR Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinnable cement primer
EXTERIOR Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqmover and including one coat of Special primer applied @0.75 ltr /10 sqm
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
Providing and fixing ISI marked oxidised MS sliding door bolt with nuts and screws etc. completed:250x16mm
Providing and fixing ISI marked oxidised MS sliding tower bolt black finished (Barrel type) with nuts and screws etc. completed: 200x10mm
Providing and fixing ISI marked oxidised MS handles conforming to IS: 4992 with necessary screws ctc. Complete. 125mm
Dismentling roofing including ridges, hips valleys and gutter etc. and stacking the materials within 50 metre lead of:
15.18 Dismantling steel work in built up sections in angles, tees, flats andchannels including all gusset plates, bolts, nuts, cutting rivets, weldingetc. including dismembering and stacking within 50 metres lead.
15.2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalentdesign mix)
15.12 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.2 Of area beyond 3 sq. metres each 414.55
10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes
12.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.2 0.80 mm thick with zinc coating not less than 275 gm/m²
Providing ridges or hips of width 60 cm overall width plain GS sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia. GI limpet and bitumen washer complete 0.63 mm thick with zinc coating not less than 275 gm/m2
Providing wood work in frames of doors, windows, clearstory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or with dash fasteners shall be paid separately) kiln seasoned and chemically treated hollock wood
Providing wood work in frames of false ceilling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.
Providing and fixing panelled or panelled and glazed shutter for doors, windows and clearstoey windows fixed with butt hinges of required size with necessary screws, excluding pannelleding which will be paiid for separately, all complete as per direction of Engineer-in-charge (Butt hinges and necessary sdrews shall be paid separately) kiln seasoned and chemically treated hollock wood 35mm thick shutter
Providing and fixing insulating board ceilling of approved quality with necessary nails etc. complete (frame work to be paid separately) Natural colour insulating board ( 12mm tk.
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of Tile 600x600 mm
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stoneaggregate 20 mm nominal size derived from natural sources) over 75mmthick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth. .
INTERIOR Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : .New work (two or more coats) over and including waterthinnable priming coat with cement primer .Interior walls
EXTERIOR Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinnable cement primer
EXTERIOR Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqmover and including one coat of Special primer applied @0.75 ltr /10 sqm
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
Providing and fixing ISI marked oxidised MS sliding door bolt with nuts and screws etc. completed:250x16mm
Providing and fixing ISI marked oxidised MS sliding tower bolt black finished (Barrel type) with nuts and screws etc. completed: 200x10mm
Providing and fixing ISI marked oxidised MS handles conforming to IS: 4992 with necessary screws ctc. Complete. 125mm
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.1 Mild steel and Medium Tensile steel bars
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.1 Mild steel and Medium Tensile steel bars
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand).
Steel work in built up tubular (round, square or ractangular hollow tubes etc) trusses ets. Including cutting, hoisting, fiaxing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washer etc. complete Hot finished welded type tubes
12.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.2 0.80 mm thick with zinc coating not less than 275 gm/m²
12 mm cement plaster of mix : 13.4.2 1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.2 1:6 (1 cement: 6 coarse sand)
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
11.5 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing wall with water proofing cement paint of required shade 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm.
16.38 'Planting of Trees and their Maintenance for one Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trenches, watering , fixing the tree guatrd and maintaining the plants for one year.
17.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mmwith a pair of 15 mm C.P. brass pillar taps
17.32 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 17.32.1 Circular shape 450 mm dia
17.65 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work :
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.17.73.2 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms.
17.35 Providing and fixing soil, waste and vent pipes : 17.35.1 100 mm dia 17.35.1.1 Sand cast iron S&S pipe as per IS: 1729
17.32 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 17.32.1 Circular shape 450 mm dia
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.1 Mild steel and Medium Tensile steel bars
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.3 Suspended floors, roofs, landings, balconies and accessplatform sqm 766.55
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand).
12 mm cement plaster of mix : 13.4.2 1:6 (1 cement: 6 coarse sand)
13.9 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 13.9.1 12 mm cement plaster
19.18 Supplying and fixing C.I. cover without frame for manholes : 19.18.2 500 mm diameter C.I. cover (medium duty) the weight ofthe cover to be not less than 58 kg
18.42 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested : 18.42.1 Up to 6 metres depth 18.42.1 Up to 6 m depth
18.42.2 Beyond 6 m Up to 12 m depth
18.42.3 Beyond 12 m Up to 18 m depth
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 18.9.6 50 mm nominal dia Pipes
18.43 Providing and placing in position filters of 40 mm diameter G.I. pipewith brass strainer of approved quality.
23.12 Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well is fullydeveloped, measuring yield of well by "V" notch method or any otherapproved method, measuring static level & draw down etc. by stepdraw down method, collecting water samples & getting tested inapproved laboratory, i/c disinfection of tubewell, all complete, includinghire & labour charges of air compressor, tools & accessories etc.,all as per requirement and direction of Engineer-in-charge.
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 18.7.5 40 mm nominal dia Pipes
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 18.8.1 15 mm nominal dia Pipes
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 18.8.3 25 mm nominal dia Pipes
18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 18.52.1 15 mm nominal bore
18.49 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 18.49.1 15 mm nominal bore
Wiring for light -point / fan point /exhaust fan point/call bell point with 2x1.5 sq. mm. FRLS P.V.C. insulated copper conductor single core cable in surface /recessed steel conduit,with modular switch,modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. 1.10.1 Group A
1.10.1 Group A
Wiiring for circuit/submain wiring alongwith earth wire with following sizes of FRLS PVC insulated copper conductor ,single core cable in surface/recessed medium class PVC conduit as required. 2x2.5 sq.mm + 1x2.5 sq.mm earth wire
2x4 sq.mm + 1x4 sq.mm earth wire
2x6 sqmm+1x6 sqmm earth wire
Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch
15/16A switch
3 pin 5/6A Socket outlet
6 pin 15/16A Socket outlet
Supplying and fixing two modular type electrinic fan regulator on the existing plate switch - - - - - as required.
Supplying and fixing 3 pin 5 A ceilling rose on the existing junction box/ wooden box - - - - as required
Supplying and fixing PVC batten/angle holder including connection etc as required
Supplying and fixing following way ,single pole and neutral sheet steel ,MCB distribution board ,240V on surface/recess complete with thinned copper bus-bar ,neutral bus-bar,earty bar,din-bar,interconnections ,powder painted including earthing etc as required (But without MCB/RCCB/Isolator)
Supplying & fixing 5 Amps to 32 Amps rating 240/415 V "C" Curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections testing & commissioning etc as required. 2.10.1 Single pole
2.10.2 Double pole
Supplying and fixing following rating double pole ,240V,MCB in the existing MCB DB complete with connections ,testing and commissioning etc.as required 2.12.2 63A
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories,and providing massonary cover plate havng locking arrangement and wih charcoal /coke and sal as required
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode,including connection/terminationwith GI thimble etc.as required.
Laying of one no of PVC/XLPE insulated and PVC sheathed,XLPE power cable of 1.1 KV grade of following size direct in ground including excavation sand cushioning protected covering and refilling the trench etc as required.
Supplying and fixing of 32 mm dia x2.00m long GI pipe braket for mounting of fluoresent /HPMV street light fitting on pole - - -- - flate iron clamp as directed
Supplying fitting fixing of Ceilling Fan etc as directed by the deptt.
Supplying including fitting of 18 W Slim LED batten with polycarbonate round shape difuser Grey end cap housing is an idea - - - - - as directed by the deptt.
Supplying with including fitting fixing ADORE LED PLUS 9W/10W. Etc as required & directed by the deptt.
Supplying with including fitting fixing Exhaust Fan . Etc as required & directed by the deptt.
Supplying with including fitting fixing of highly efective front openable 45 W IP66 Street light/Campus light with alluminium presure dia-cost housing thughtened glass in the front and peanut lens for batwing light distribution - - - - - as directed by the deptt. (Orient, Bajaj or equivelent)
Supplying with including fitting fixing of 1 H.P. Motor pump set (Crompton, Kirlosker as required and directed by the deptt.
Supplying of following size PVC/XLPE insulated 1.1 KV Gd Solid Alluminium conductor up to 10 SQMM - - - - as approved by the deptt. (i) 10.00 sq. mm 2 Core U.G. Cable
(ii) 95.00 sq. mm 3&1/2 Core U.G. Cable
Supplying with erection of PSC Pole 8.50 Mtrs length with PCC grounting as required complete as specified and directed by the deptt.
Supplying and fitting and fixing Single Phase Digitel type Energy Metre tested with APDCL including Load sequrity Metre security, Labour charge and connection charge with all accessories materials as required complete as directed by the deptt.
Sri Mukul Mochahari
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .