Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC PLOT NO 8 5179 SAILASHREE VIHAR CHANDRASEKHARPUR BHUBANESWAR DIST KHURDA ODISHA 751 021 | KHORDHA | ODISHA | 751021 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹6.6 L+₹11,459 (1.77%)Rejected-Finance | L2 | Rejected-Finance Being L2 bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to documents required to meet enlistment criteria in compliance of Para 8 b of Appx A to NIT not found uploaded |
Tender Value
₹6.7 L
EMD Value
₹13,300
Closing Date
24 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Avinash Mishra IDSE EE
Garrison Engineer (I) (CG) Bhubaneswar, Plot No 190/702, Kokila Residency, 2nd Floor, Anant Vihar, Post-Pokhariput, Bhubaneswar- 751020
MAINTENANCE AND OPERATION OF LIFT THROUGH OEMS(JOHNSON)/ACCREDITED AGENCIES AT CGRA BHUBANESWAR 5 ACRES LAND BHUBANESWAR UNDER GE (I) (CG) BHUBANESWAR
2023_MES_603683_2
8397/BBSR/04/E8
Open Tender
Miscellaneous Works
Item Rate
335 days
Bhubaneswar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (I) (CG) Bhubaneswar
₹13,300
Yes
9 Sept 2023
3 Jul 2023
31 Jul 2023
3 Jul 2023
24 Jul 2023
10 Jul 2023
Amount
Maintenance and Operation of lift No G7728 through AMC (Minimum Gold Level) under repair, replacement, Overhaulling, Maintenance of Lifts through OEMs (Johnson) / accredited Agencies installed at CGRA Bhubaneswar of capacity 13 passengers including necessary minor repair / replacement of defective parts work if required in any emergency and kept the the lift in working condition at round the clock complete all as specified and directed.
Maintenance and Operation of lift No G7729 through AMC (Minimum Gold Level) under repair, replacement, Overhaulling, Maintenance of Lift through OEMs (Johnson) / accredited Agencies installed at CGRA Bhubaneswar of capacity 13 passengers including necessary minor repair / replacement of defective parts work if required in any emergency and kept the the lift in working condition at round the clock complete all as specified and directed.
NOTES FOR ITEM NO 1.00 & 2.00 :- 1. Service the lifts at regular intervals and as frequently as the company deems necessary based on the age, nature and condition of the elevator and will take all responsible care and maintain the lift equipment in safe and proper working condition. 2. Carry out the services work whenever possible on day convenient to the customer other than sunday and holiday and during regular working hours. 3. Depute an entitled authorised service personnel to attend all call backs during normal working hours and also if any emergency even after working hours. 4. Replenish the gear and motor bearing with necessary Johnson/authorised lubricants whenever necessary including checking /cleaning of all moving parts and keep them both electrically and mechanically in perfect working condition .
NOTES FOR ITEM NO 1.00 & 2.00 (Contd):- 5. Checking of minimum/maximum oil levels of gear, motor and guide lubricant tank complete all as directed. 6. Lubrication of motor bearing , brake pivets , weel bearing , mechanical limit switches, gate rollers and tracks, safety gear mechanisum, lock and rollers, connecting wires , retiring ram etc complete all as directed. 7. The rate quoted is deemed to be inclusive to tools and safety equipment, CRC SPARY, minor consumables such as PVC insulation tape, screws, fuse wire, clips,freuuel,locks,First Aid Box required for running and maintenance of plants 8. Inspection of electrical system such as main switch, over load protection, control relays , connecting wires, single phase preventor, main and lighting fuses, contact allingments etc all as directed. 9. Checking and inspection of motor terminals, brake liners, coupling bushes, limit switches, ultimate limit switch magnetic switches , push button movements, brake shoes, noise level, working condition of LEDs, gate lock, spindle movement, condition of lock brake condition of rubber roller , mechanical lock plate , rope anchorages, tightness of rope clips, position of equaliser , trailing of cables, condition of cable , door allingment clearance between vain and rollers, all mechanism bolts , door bearings, floor anounciator working condition, door skate, conditon of door switches, safety edges etc complete all as directed. 10. Checking of all emergency devices such as ARD working condition, Battery condition, over load device working condition, over load anounciator and display condition, emergency ligh working condition, emergency siren alaram condition , charing unit condition etc.complete all as directed. 11. Checking of lift well lighting, machine room lighting, machine room ventilators , machine room door including cleaning of machine room, lift well, enclosure, landing gates, car gates, car inside, lift pit etc
NOTES FOR ITEM NO 1.00 & 2.00 (Contd):- 12.Checking the following devices :- (a) Breake releasing mechanisum working condition (b) Break lock nut measurement in mm (c) Break arm switch (d) Emergency battaery condition (e) Trap door access condition. (f) Breake plunger lock nut tightness (g) Additional car gate lock contact (h) Controller light working condition (j) Press and speek working condition (k) Shaft controller wiring tightness (l) Oil buffer working condition and oil level (m) Any abnormal noise obseerved. (n) Carryout the load testing ones in a year (o) Regularly Cheaking of ARD System (p) Consequence cheakinh of fault electrical System. (q) Consequence cheakinh of Earthing System.
Material and labour for replacement of the 3 Nos harness cable kit for lift No. L-G7728 at CGRA Bhubaneswar complete all as specified and directed.
Material and labour for repair work to maintain the clearance between CWT Frame and buffer for Lift No.L-G7728 or L-G7728 complete all as specified and directed.
Supply only following Spare parts for Lift No L-G7728/ L-G7729:-
Three way intercom (Press and Speak) speaker BH123/Z
Three way intercom (Press and Speak) speaker BH123/M
Screen sensor WECO917B,220V AC,212BEAMS
ECW-S110 (For overload device)
PM Inverter BG201
Encoder extn cable ERN 1387, encoder end Male D & VVVF end Male D to suit nice 3000+ drive
Encoder HEIDENHAIN ERN 1387-2048-62814-70-F8 (ID NO:385488-02)
12" Cabin fan regular black guard and silver coloue blade (remi)-02 Nos
LED Downlighter (wipro)-3W-Model LD80-200-XXX-60-XX - (05 Nos)
Orange square dot matrix display with gong driver SG1005
Logic board for Johnson make © ARD -25 PIN-1.5 KVA and 2.5 KVA
Power board for Johnson make © UPS
SMPS 12V DC,50W,4A
POD processor CPU card- G/GR230 Card ver 3
POD processor display cum logic card- G/GR221 ver 3
GR interface board for landing (G107 R1)
GR serial car card (GR 227)
10A 110 V DC contactor Siemens
10A 110 V DC contactor Siemens
NARESH KUMAR BEHERA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .