CWE (AF) AMBALA
HQ CWE (AF) Ambala Ambala cantt
SPECIAL REPAIR / REPLACEMENT OF CONTROL and RELAY PANEL FOR 33/11 KV POWER TRANSFORMERS IN MRS AND FEEDER PROTECTION RELAYS AT AFS SARSAWA UNDER GE (AF) SARSAWA
2024_MES_667548_2
CWE/AF AMB/SAR-29/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
SARSAWA
For MES enlisted contractor Class E Category b(iii) and for un-enlisted contractor refer NIT
8 documents required · 8 mandatory
₹500
GE (AF) SARSAWA
₹48,480
Yes
16 Jan 2025
7 Oct 2024
31 Oct 2024
7 Oct 2024
29 Oct 2024
16 Oct 2024
7 Oct 2024 - 10 Oct 2024
Amount
Taking down old unserviceable Control and relay panel after dismantling all cable and earthing connection complete with proper safety arrangement complete all as specified & directed.
S&F 33 KV control and relay panel indoor type for above 36 KV Vaccum circuit breaker. The panel shall be with back access double door arrangement, dust and vermin proof, IP 54 class protection and made up of 2mm thcik CRCA MS sheet powder coated finish over one coat of red oxide primer, both side operating type, including internal wiring using 1.1 KV FRLS insulated multistrand cable 2.5 Sqmm for CT/PT and control circuit, numbered and colour code as per IS-5578/1984 having suitable entry for cable consisting of the following complete all as specified & directed.:- (a) Main transformer differential protection relay with LCD displaying mimic bay for ON/OFF control and monitoring of feeder current, Built in disturbence recorder and event logger to monitor the sequence of events (SoE) using upto 1000 event codes. The relay shall be communicable on IEC 61850 GOOSE platform, using RJ45/USB/OF port and capable of binary signal transfer between local and remote relay over fibre optic. (i) Line differential with high set and low set (stabilised) with second harmonic restraint to by pass transformer inrush. The scheme will be implemented using single mode fibre optic protection communicable link between local and remote relay, suitable single mode fibre optic port shall be part of the relay including connected items like LIU and patch cord etc. (ii) Over current and earth fault protection with minimum pickup at low set of 5% and 1% respectively.
BOQ item No. 2.00 Continued....../- (iii) Transient/intermittent earth fault protection. (iv) Phase discontinuity protection. (b) Flush mounted auxiliary relay for:- (i) Trip circuit supervision. (ii) Master Trip. (iii) Fuse fail (PT) supervision operated. (iv) SF-6 gas pressure low. (v) DC Supervision scheme. (c) Metering:- (i) Metering equipment including 01m x Digital voltmeter (Acc. Cl. 0.5), 01 x Digital Ammeter (Acc.CI.0.5), 01 x Tri-vector meter (Acc.C1.0.0) (ii) 01 No. Multifunction meter (Acc.C1.0:5) shall be provided with LCD display for measuring current voltage, power, power-factor and energy parameters, total Harmonic Distortion and Maximum Demand Indication, same shall be communicable on Mod Bus via RS485 port. (d) Indicating lamp. (i) Bus-01 Isolator ON/OFF. (ii) Bus-02 Isolator ON/OFF
BOQ item No. 2.00 Continued....../- (iii) Line isolator ON/OFF/Earth. (iv) CB Auto trip. (v) CB ON. (vi) CB OFF (vii) CB Spring charge. (viii) Trip circuit healthy. (ix) DC Available LED with Push button. (x) R-Y-B phase LED indication. (e) Semaphore indicator (i) Circuit breaker ON, OFF (ii) Bus-01 isolator ON, OFF (iii) Bus-02 isolator ON, OFF (iv) Line isolator ON, OFF, EARTH (f) Control switches/Push Buttons (i) Trip-Neutral-Close switch for circuit Breaker control - 01 No. (ii) MCB for AC isolation - 01 No. (iii) MCB for DC isolation - 01 No. (iv) Heater switch with thermostat - 01 No.
BOQ item No. 2.00 Continued....../- (v) 3-pin socket with ON/OFF switch - 01 No. (vi) CFL lamp with ON/OFF switch - 01 No. (g) 12-window Annunciator with hooter and mute, acknowledge, Reset and test Buttons for:- (i) OC Trip Alarm. (ii) EF Trip Alarm. (iii) Line differential Trip alarm. (iv) PT fuse failure Alarm. (v) Trip circuit alarm. (vi) Spare. (h) Test Terminal Block for CT. (j) Suitable terminal arrangement along with light Interface unit, Patch-Cord and associated port for spliced connection with external armoured fibre optic cable shall be provided for achieving pilots-wire connection (Line-differential). Notes for BOQ Item No. 2.00:- (i) All cable termination, lugs, gland are deemed to be included in quoted rate.
Notes for BOQ item No. 2.00 Continued....../- (ii) Contractor shall submit all type test certificates as per IEC-61850 and GA/Equipment drawings with control wiring diagram of 33 KV control & relay panel to GE for the approval of Accepting officer before approval of sample and confirming firm order of C&R Panel to the manufacturer. (iii) The routine tests of C&R Panel shall be carried out by representative of Accepting Officer at factory premises as and when requested by contractor through GE and all T&P & equipments required for testing shall be arranged by contractor. (iv) Commissioning and testing of C&R Panel after installation shall be done through AEI/EI/SEI as and when requested by contractor to GE. GE shall request the concerned AEI/EI/SEI directly for early testing. (v) Suitable training to be provided to the staff deployed at 33 KV substation in respect of following items:- (a) Relay setting and parameteirzation. (b) Relay configuration with respect to I/P, O/P and functional block for protection. (c) Goose configuration. (d) Configuration and interfacing required for third party. (e) SCADA system integration if applicable. (f) Diagnostic features.
S&F in replacement of 11 KV feeder protection numerical IDMT relay 3OC + 1EF with high instantaneous high set function complete all as specified & directed. Make:- Model No. CGI 14 N of CG or equivalent of ABB / L&T
S&F in replacement of control cable to 1 MVA/ 2MVA Transformer and AVR breaker panel installed in 33 KV yard of size 2.5 Sqmm 12 core solid armoured copper cable with necessary fastening element and with saddles complete all as specified & directed.
Taking down / dismantling old unserviceable GI Earthing complete all as specified & directed
M&L earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm, 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level, connected to GI earth lead strip 32mm x 6mm upto 7.5 mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly including watering pipe GI 20 mm bore medium grade 2.5 mtr long and protection pipe GI medium grade 40mm bore upto 7.5 mtr long, wire mesh, funnel,lugs, salt, charcoal dust, excavation & earthwork in any type of soil and refilling, pit chamber of PCC 1:3:6 type C1 using 20 mm graded mechnically crushed stone aggregates , RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates as in pit cover slab 40mm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways including necessary form work all as shown in Electrical plate No 3 of SSR Part-I, including testing on completion at site complete all as specified & directed. Notes:- (i) On testing if the desired earth resistance less than 05 ohm is not obtained, earthing will be generated at No extra cost, till the desired earth resistance is obtained. (ii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
Supply, installation, testing & commissioning of DC battery bank with charger having input connection of 230 volt AC and output 30 volt DC comprising of following inculding taking down of old unserviceable battery bank with charger complete all as specified & directed.:- (a) Battery bank of 15 Nos. 2 volt 100 AH with stand capacity with VRLA battery bank conforming to IS 1651-1979, performance as per IS 8702, nominal cell voltage 2 volt plastic resin / ABS / PP container , epoxy coated exhaust fans to remove the gas emissions, suitable rack / stand for continous operation of 30 minute back up. (b) Float cum Boost charger of required rating with regulator including for trickle charging . (c) Control panel with LED indication & Alarm annunciation on the panel for main ON, DC ON, charging position etc.
For Credit Schedule refer tender documents. The amount of credit schedule shall be deducted from total quoted amount of BOQ to arrive contract sum.
M/s Shiksha Enterprises (BID ID -3153216)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .