Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 1170 BENGALI MOHALLA NEAR PRABHAKAR HOSPITAL AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹10.1 L+₹30,778.88 (3.16%)Rejected-AOC | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹10.6 L+₹86,753.88 (8.90%)Rejected-AOC 217 ARHAT BAZAR KASAULI DISTT SOLAN HP 173204 | SOLAN | HIMACHAL PRADESH | 173204 | L3 | Rejected-AOC Quoted L3 |
Tender Value
₹14.9 L
EMD Value
₹29,800
Closing Date
9 Aug 2021, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
REPAIR TO INTERNAL WIRING, REPAIRS TO GEYSER AND COOLING APPLIANCES AT AF STN KASAULI UNDER GE AF CHANDIGARH
2021_MES_459108_1
GE (AF)/CHD/T-17/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kasauli
All as per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹29,800
Yes
19 Dec 2021
12 Jul 2021
11 Aug 2021
12 Jul 2021
9 Aug 2021
26 Jul 2021
12 Jul 2021 - 19 Jul 2021
Amount
Taking down carefully aluminium/copper point wiring (light/fan/socket/ power) complete including fittings such as switches, sockets, ceiling roses pendents, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall all as specified and directed by Engineer-in- charge
Taking down unserviceable any type of Main Switch, industrial sockets, DB's including MCBs incl wooden/GI/MS sheet board,removing the materials/debris and making good the disturbed surfaces of wall, floors and ceiling etc. to match with the original existing finish all as directed etc all as directed.
Point wiring with approved colour coding as per IS with multistranded copper conductor 1.5 Sq mm (nominal area), single core, flame retardent low smoke (FRLS), PVC insulated and un sheathed cable 1100 Volts grade, ISI 694 marked TEC and FIA approved in and including PVC concealed conduit medium grade, suitable for light/bell/fan point terminated in and including mild steel terminl boxes covered with new 3 mm thick HYLAM Make plastic laminated sheet and controlled by one switch including flame retardent low smoke (FRLS) PVC insulated un sheathed multistranded copper conductor 1.5 Sq mm (nominal area)single core cable as earth continuity conductor to common earth and connected to earth dolly , complete all as specified and directed. Note :-The cost of making good to the disturbed surfaces to match with the adjacent surfaces shall be deemed to be included in the quoted rate.
(a) One light point controlled by one switch one way
(b) One fan point controlled by one switch one way
(c) 2 in 1,3 pin Switch socket Combination , 5 Amps on the same board with other switches, with cables 1.5 sq.mm size
All as per item No 3, here in before but with cable size 1.5 Sq mm for 2 in 1, 3 pin 5 Amps Switch socket Combination on independent board using 2.5 sqmm multistrand insulated copper earth continuity conductor of size 1.5 sqmm all as specified and directed by Engineer-in-Charge.
All as per item No 3, here in before but with cable size 4 Sq mm for 2 in 1, 3 pin, 15 Amps Switch socket Combination on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed by Engineer-in-Charge.
All as per item No 3 above but one light point controlled by 2 - two way switches with 1.5 sqmm size.
Point wiring with approved colour coding as per IS with multistranded copper conductor 1.5 Sq mm (nominal area),single core,flame retardent low smoke (FRLS), PVC insulated and unsheathed cable 1100 Volts grade, ISI 694 marked TEC and FIA approved in existing concealed/surface conduit/ casing caping, without mild steel sunken boxes (Terminal boxes) suitable for light/bell/fan point terminated in existing terminl boxes covered with new 3 mm thick HYLAM Make plastic laminated sheet including flame retardent low smoke (FRLS) PVC insulated un sheathed stranded copper conductor 1.5 Sq mm (nominal area)single core cable as earth continuity conductor to common earth and connected to earth dolly , complete all as specified and directed. Note :-The cost of replacement of disturbed/broken fittings/ saddles/ nails/ screws etc and making good to the disturbed surfaces to match with the adjescenet surfaces shall be deemed to be included in the quoted rate.
(a) One light point controlled by one switch one way
(b) One fan point controlled by one switch one way
All as per item No 7 here in before but with cable size 1.5 Sq mm for 2 in 1 3 pin 5 Amps Switch socket Combination on independent board using 2.5 sqmm multistrand insulated copper earth continuity conductor of size 1.5 sqmm all as specified and directed by Engineer-in-Charge.
All as per item No 7 here in before but with cable size 4 Sq mm for 2 in 1 3 pin, 15 Amps Switch socket Combination on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs for switch piano flush type 5 amps single pole one way complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs for switch Socket combination 2 in 1 3 pin 5 and 5 Amp flush type Universal .complete all as specified and directed by Engineer-in-Charge.
S & F in repairs for ceiling rose surface bakelite two to three terminalscomplete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs for switch piano flush type 6 amps single pole Two waycomplete all as specified and directed by Engineer-in-Charge.
S&F in repairs decorative LED 20 watt batten fitting 20 watt prewired suitable for retrofit LED tubes prewired upto connection block and connecting with three core PVC cpper flexible cable of 1.5 sqmm from ceiling rose to connector block including taking down old Unserviceable surface mounted fitting of any type any wattage and type complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repairs fluorescent tube rod 36/40 watts , 240 volts complete all as specified and directed.
S & F in repairs recess mounting LED slim ceiling light fitting extrured aluminium housing and milky diffuser suitable for 36 W 2' X 2' Ceiling Cell of 36 watt complete complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs LED Bulk head luminaires ,1X10 Watts with IP 65 & heat resistant complete prewired .complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs lamp holder ,PVC / Polycarbonate type with back plate suitable for batten fittingscomplete all as specified and directed by Engineer-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI wire 4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.3, including exc & earth work in any type of soil, disposal of soil, providing alternate layer of charcoal and common salt, construction of pcc earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B1 cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funneland wire mesh and wateing pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed at site. Note : Main earth lead beyond 7.5 meter shall be measured and paid saperatly.
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through PVC conduit concealed as reqds size confiming to IS: 9537(Part-3), and including dismantling & taking down exsiting wire with accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area.
Supply and fixing, in repairs factory made sheet metal enclosure single pole & neutral with a two pin & earth plug and socket etc complete with one single pole 'B' series MCB 20 Amps 240 Volts, all as specified and directed.
Supply and fix, in repairs of ceiling fan regulators step type electronic for 1200/1400 mm sweep ceiling fan and connecting up complete with provision of PVC flexible cable size 1.5 Sqmm twin core copper conductor , complete , all as specified and directed.
S & F in repairs Sheet metal distribution board double door , vertical type VTPN suitable for mounting of MCCB 4 pole as incoming and MCBs as outgoing, including earth dolly made of CRCA sheet of thickness 1.6 mm with IP- 43 protection, 8 ways, 415 volt, fixed flush to wall, complete all as specified and directed by Engineer-in-Charge.
Supply fix in repairs Sheet metal distribution board double door , vertical type VTPN suitable for mounting of MCCB 4 pole as incoming and MCBs as outgoing, including earth dolly made of CRCA sheet of thickness 1.6 mm with IP- 43 protection, 4 ways, 415 volt, fixed flush to wall, complete all as specified and directed by Engineer-in-Charge.
S & F MCCB, four pole, 100 Amp, 415 Volts, 16 KA, including making in coming/ outgoing connections, fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing, in repairs of MCBs , SP , 240 Volts , 5 Amps to 40 Amps , B curve , 10 kA , complete all as specified and direc
Supply and fixing, in repairs of MCBs , SP , 240 Volts , 5 Amps to 40 Amps , C curve , 10 kA , complete all as specified and direc
Supply and fixing, in repairs of MCBs , SPN , 240 Volts , 5 to 40 Amps , B curve , 10 kA , complete all as specified and directed.
Supply and fixing, in repairs of MCBs, TPN ,415 Volts, 32 Amps , B curve , 10 kA , complete all as specified and directed.
Supply and fixing, in repairs of MCBs, TPN ,415 Volts, 63 Amps , B curve , 10 kA , complete all as specified and directed.
Supply and fixing, in repairs of MCBs Distribution board , sheet metal enclosure, SPN 240 Volts , 08 ways with 200 amps rated bus bar , double door for MCBs, ,with IP 43 protection ,complete all as specified and directed.
Supply and fixing, in repairs of MCBs Distribution board , sheet metal enclosure, SPN 240 Volts , 12 ways with 200 amps rated bus bar , double door for MCBs, ,with IP 43 protection ,complete all as specified and directed.
Taking down and dismantling any type of exhaust fan/ceiling fan and servicing, greasing, oiling and remove silt particles complete and re-assembling the same and refixing , testing and commissioning of exhaust fan for smooth running, as per entire satisfaction of Engineer-in-Charge. Note : (a) Cost of items like fixing clamps for capacitors with screws, insulation sleeves, internal wiring connections, connectors, clips etc are deemed to be included in the quoted rate. (b) Replacement of ball bearings will be measured and paid separately.
Supply only Ball bearing for exhaust fan 300 to 380 mm sweep, complete all as specified and directed by Engineer-in-Charge
Supply only Ball bearing for exhaust fan 450 mm sweep, complete all as specified and directed by Engineer-in-Charge.
Supply only Ball bearing for ceiling fan 1200 mm sweep, complete all as specified and directed by Engineer-in-Charge.
Dismantling exhaust fan 300 to 380 mm sweep of any make & type, cutting and taking out old burnt windings, cleaning thoroughly, rewinding the fan motor with super enameled copper winding wire of appropriate gauge including replacement of necessary allied insulating material like vanish, sleeves, insulation sheet etc. reassembling and testing, complete all as specified and directed.
Dismantling exhaust fan 450 mm sweep of any make & type, cutting and taking out old burnt windings, cleaning thoroughly, rewinding the fan motor with super enameled copper winding wire of appropriate gauge including replacement of necessary allied insulating material like vanish, sleeves, insulation sheet etc. reassembling and testing, complete all as specified and directed.
Dismantling ceiling fan 1200 mm sweep of any make & type, cutting and taking out old burnt windings, cleaning thoroughly, rewinding the fan motor with super enameled copper winding wire of appropriate gauge including replacement of necessary allied insulating material like vanish, sleeves, insulation sheet etc. reassembling and testing, complete all as specified and directed.
Disconnecting from socket out lets Split type AC of capacity upto 2 ton of any brand, servicing by dusting, cleaning of indoor and out door units, rectifying gas leakage by applying necessary brazing, adjusting and rectifying faulty operation of elect and electronic remote control panels, replacing of perished elect wires for proper connection from voltage stablizer, reinstalling the units to its original position, replacement of remote cell and testing complete all as specified and directed.
Disconnecting from socket out lets Split type AC of capacity upto 1.5 ton of any brand, servicing by dusting, cleaning of indoor and out door units, rectifying gas leakage by applying necessary brazing, adjusting and rectifying faulty operation of elect and electronic remote control panels, replacing of perished elect wires for proper connection from voltage stablizer, reinstalling the units to its original position, replacement of remote cell and testing complete all as specified and directed.
Disconnecting elect connections of refrigerators of capacity upto 310 ltr from wall socket, servicing by dusting, cleaning of the appliance in all respect, rectfying gas leakage by applying necessary brazing, defrozing of the deep freezing unit, replacing of perished elect wires for proper connection from voltage stablizer/ wall socket, reinstalling the units to its original position, and testing complete all as specified and directed.
Supply and charging refrigent gas R-22/307 in Acs , refriferators etc installed at various buildings including brazing and testing to the satisfaction of Engr in charge complete all as specified.
Dismantling of old unserviceable compressor from split type AC 2 ton, supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed. Make of compressor : Carrier/Kirloskar/Voltas/Techumseh
Dismantling of old unserviceable compressor from split type AC 1.5 ton, supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed. Make of compressor : Carrier/Kirloskar/Voltas/Techumseh
Dismantling of old unserviceable compressor from refrigerator 300/310 ltr capacity., supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed. Make of compressor : Carrier/Kirloskar/Voltas/Techumseh
Dismantling of old unserviceable compressor from refrigerator 210/230 ltr capacity., supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed. Make of compressor : Carrier/Kirloskar/Voltas/Techumseh
Supply and replace thermostat for Split/window type AC 1.5 Ton complete all as specified and directed
Supply and replace PCB of suitable size and configuration and as per sample for split type AC of capacity upto 2 TR all as specified and directed.
Supply and replace asynchronous PSC motor single phase for AC suitable to work on 230 volts, 50 Hz elect supply, complete all as specified and directed.
Supply and replacing cooling coil of Refrigerator capacity 210/230 ltr of any make/model, complete all as specified.
Supply and replacing cooling coil of Refrigerator capacity 300/315 ltr of any make/model, complete all as specified.
Supply and replacing Thermostatic switch of Refrigerator capacity upto 210/310 ltr of any make/model, complete all as specified.
Supply and replacing starting relay of Refrigerator capacity 210/230 ltr of any make/model, complete all as specified.
Supply and replacing starting relay of Refrigerator capacity 300/315 ltr of any make/model, complete all as specified.
Supply and replacing over load relay of Refrigerator capacity 210/230 ltr of any make/model, complete all as specified.
Supply and replacing over load relay of Refrigerator capacity 300/315 ltr of any make/model, complete all as specified.
Supply and replace thermostat for Split/window type AC 2 Ton complete all as specified and directed
supply and replace running capacitor 45 Mfd for air conditioner 2 ton capacity complete all as specified and directed.
supply and replace running capacitor 36 Mfd for air conditioner 1.5 ton capacity complete all as specified and directed.
supply and replace starting capacitor 100 to 120 Mfd for air conditioner 2/1.5 ton capacity complete all as specified and directed.
Taking down geyser of any capacity 25/50 from wall mountings after disconnecting elet and water connections to carry out repairs. Refixing of geyser of any capacity to wall mountings and making elect and water connections, testing and commissioning (Note :- Repairs/replacement of parts carried out will be measured and paid seperately under resp items.)
Taking out complete internal assy i.e. inner tank, inlet and outlet assy, heating element, thermostat etc,of geyser of capacity 25 litres, de-scaling the geyser inner tank using appropriate chemical(descaling agent), cleaning and washing complete accessories, replacing of glass wool and reassembling the same all as directed.
Taking out complete internal assy i.e. inner tank, inlet and outlet assy, heating element, thermostat etc,of geyser of capacity 50 litres, de-scaling the geyser inner tank using appropriate chemical(descaling agent), cleaning and washing complete accessories, replacing of glass wool and reassembling the same all as directed.
Supply and replace inner copper container of 25 litres capacity as per sample including replacement of glass wool of superior quality, testing complete all as specified and directed.
Supply and replace inner copper container of 50 litres capacity as per sample including replacement of glass wool of superior quality, testing complete all as specified and directed.
Supply and replace inner steel container of 25 litres capacity as per sample including replacement of glass wool of superior quality, testing complete all as specified and directed.
Supply and replace inner steel container of 50 litres capacity as per sample including replacement of glass wool of superior quality, testing complete all as specified and directed.
Supply and fixing in replacement of apparatus plate assembly of brass suitable for 25 ltr capacity geyser with collar, gasket, inlet and outlet facilities, housing to accommodate heating element, thermostat, thermal cut out complete all as specified and directed. Note :- Cost of drilling work, fixing accessories like nuts, bolt, washer/check nut etc and taking down and refixing of geyser are deemed to be included in the quoted rate.
Supply and fixing in replacement of apparatus plate assembly of brass suitable for 50 ltr capacity geyser with collar, gasket, inlet and outlet facilities, housing to accommodate heating element, thermostat, thermal cut out complete all as specified and directed. Note :- Cost of drilling work, fixing accessories like nuts, bolt, washer/check nut etc and taking down and refixing of geyser are deemed to be included in the quoted rate.
Supply and replace glass wool of superior quality for geysers all as directed.
Supply and replacement of MS sheet bottom cover in two halves of semi circle of dia and thickness as per sample, duly painted with two coats of white synthetic enamel paint over a coat of red oxide primer and necessary preparatory works, suitable for geyser of capacity 25 ltrs all as specified and directed.
Supply and replacement of MS sheet bottom cover in two halves of semi circle of dia and thickness as per sample, duly painted with two coats of white synthetic enamel paint over a coat of red oxide primer and necessary preparatory works, suitable for geyser of capacity 50 ltrs all as specified and directed.
Replacement of MS sheet top circular cover made to shape with necessary holes for inlet and outlet pipes, thick and dia as per sample duly painted with two coats of white synthetic enamel paint over a coat of red oxide primer and necessary preparatory works, suitable for geyser of capacity 25 ltrs all as specified and directed.
Replacement of MS sheet top circular cover made to shape with necessary holes for inlet and outlet pipes, thick and dia as per sample duly painted with two coats of white synthetic enamel paint over a coat of red oxide primer and necessary preparatory works, suitable for geyser of capacity 50 ltrs all as specified and directed.
Supply and replace non return valve cast copper alloy screwed both end for iron pipe 15 mm dia complete all as specified and directed.
Supply and replace fusible plug cast copper alloy screwed one end for iron pipe 15 mm dia ,complete all as specified and directed.
PVC connections heavy duty, 15mm size with brass nuts of length 300mm ,complete all as specified and directed.
Suplly and replace heating element 2 KW A/C 230 Volts (Cup / Trianle Type ) ISI marked complete all as Specified .
Suplly and replace heating element 1.5 KW A/C 230 Volts (Cup / Trianle Type ) for 25 Litrs, 35 liters ISI marked complete all as Specified .
Supply and replcing thermostatic switch A/C 230 Volts ISI marked suitable for 25 to 50 litres water heater / Geyser
Suplly and replace heating element 1.5 KW A/C 230 Volts (Cup / Trianle Type ) 03 liters ISI marked complete all as Specified .
Note:- Amount of credit of Rs. 32149.50 for retrieved materials is mentioned in Schedule of Credit Page No 108 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Varindera And Varindera Construction
Vinod Kumar Aggarwal
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .