Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹98.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹1.0 Cr+₹3.4 L (3.41%)Rejected-Finance BANPUR BATWARA SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹1.0 Cr+₹3.6 L (3.64%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹1.0 Cr+₹4.8 L (4.85%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹1.1 Cr+₹5.8 L (5.78%)Rejected-Finance HOUSE NO 138 B HILL VIEW LANE NO 03 INDRA NAGAR SRINAGAR 190004 J K | SRINAGAR | JAMMU AND KASHMIR | 190004 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
26 Oct 2023, 6:00 pmClosed
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS
ADDN ALTN OF FLOORING AND SANITARY FITTINGS OF TOILETS AND PROVN OF FLOOR TILLING IN SINGLE LIVING OR ACCN OF EW BN AT BB CANTT SRINAGAR UNDER GE 864 EWS
2023_MES_619657_1
CWEK-39/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE 864 EWS
Class B Categories a i ii AND b i
6 documents required · 6 mandatory
₹1,000
GE 864 EWS
₹1.9 L
HQ 133 WORKS ENGRS
2 Feb 2024
19 Sept 2023
3 Nov 2023
19 Sept 2023
26 Oct 2023
13 Oct 2023
19 Sept 2023 - 30 Sept 2023
1 Oct 2023
Amount
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and directed by Engr in Charge.
M & L 25 mm thick PCC 1:2:4 Type B-1 (using 20 mm graded aggregate ) complete all as specified and directed by Engr in Charge.
Dismantling floor, hearth or wall tiling including CM bedding (but not backing),skirting complete all as specified and directed by Engr in Charge.
M&L Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles and including 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed by Engr in Charge.
M&L Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles and including 15mm thick screed bed in cement mortar 1:4 , complete all as specified and directed by Engr in Charge.
M&L Glazed ceramic colour tiles in vertical surface 350x 250x 7 mm/ 450X350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and including 10mm thick bedding layers in cement mortar 1:3 complete all as specified and directed by Engr in Charge.
M & L Machine cut kota stone/ Marble slab flooring 20 - 25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including 15mm thick screed bed in cement mortar 1:4 and jointed with grey cement slurry @ 2 Kg per square complete all as specified and directed by Engr in Charge.
M & L Machine cut kota stone/ marble slab 20 - 25 mm thick in riser of steps, dado and pillar laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing and including 10mm thick bedding layers in cement mortar 1:3 complete all as specified and directed by Engr in Charge.
M & L granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr in Charge.
Taking down cement plaster from brick walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr in Charge.
M&L 15 mm thick rendering on fair faces of brick work or concrete surface in cm 1:4 two layer 10+5mm thick and mixed with integral water proofing compound @ 3% by weight of cement as in top layer of plaster and finished the surface even and smooth without using extra cement complete all as specified and directed by Engr in Charge. (Note : supply only WPC shall be measured and paid separately against respective item).
M & L 10mm thick rendering on fair faces of brick work or concrete surface in cm 1:6 to be finished even and smooth without using extra cement and mixed with WPC complete all as specified and directed by Engr in Charge. (Note : supply only WPC shall be measured and paid separately against respective item).
M&L Rendering 5mm thick in cement mortar (1:3) & finishing the surface even & smooth without using extra cement as in ceiling, soffits of slab and mixed with WPC complete all as specified and directed by Engr in Charge. (Note : supply only WPC shall be measured and paid separately against respective item).
Supplied only Integral waterproofing compound complete all as specified and directed by Engr in Charge.
M&L Preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed by Engr in Charge.
M & L preparing surface of newly plastered walls and applying two coats of oil bond distemper over chalk whitening preparatory to distempering complete all as specified and directed by Engr in Charge.
M&L preparing newly prepared surfaces of ceiling and applying three coats of white wash complete as specified and directed complete all as specified and directed by Engr in Charge.
M&L Preparing old surface of walls and applying one coats of cement base paint complete all as specified and directed by Engr in Charge.
M & L preparing old surface of walls and applying one coats of oil bond distemper complete all as specified and directed by Engr in Charge.
M & L Preparing old decorated surfaces of ceilings and applying one coats of white wash complete all as specified and directed by Engr in Charge.
M & L preparation of old wooden surfaces of any description , not other wise described, over 10cm width or girth including and applying one coat of synthetic enamel paint complete all as specified and directed by Engr in Charge.
Taking down and refixing in same opening for shutters of any description exc 1sqm but n. exc 2 sqm each complete all as specified and directed by Engr in Charge.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) n. exe 1.50 sqm in each complete all as specified and directed by Engr in Charge.
S&F 35 mm thick 2nd class soft wood plain framed panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board with commercial face veneers complete all as specified and directed by Engr in Charge.
S&F solid PVC door frames of size 50mm X 47mm made out of 5mm plain color PVC sheet reinforced with MS square tube complete all as specified and directed by Engr in Charge.
S&F factory made solid panel PVC door shutter, 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded, plain colour PVC "C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as per specification and drawing complete all as specified and directed by Engr in Charge.
S&F stainless steel butt hinges medium weight with stainless steel pins 100mm long complete all as specified and directed by Engr in Charge.
S&F, aluminium anodised, barrel tower bolts of extruded section with length of bolt 200 mm complete all as specified and directed by Engr in Charge.
S&F extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed by Engr in Charge.
S&F Aluminium alloy, anodised, sliding door bolt 300 mm with hasp, staple (bolt type) and fixin glips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed by Engr in Charge.
Demolition of cemen Concrete of any description and in any position not otherwise specifically complete all as specified and directed by Engr in Charge.
Providing PCC (1:2:4) type B0 using 12.5 mm graded aggregate 25mm average thickness of bottom & top surface of sunken floor of wc/bath/toilet finished even and smooth without using extra cement mixed with water proofing compound Dr Fixid pidiproof LW+ or equivalent at 200ml/50Kg of cement and fixed with 32 mm GI Pipe 450 mm long spout complete all as specified and directed by Engr in Charge.
M&L for rendering 15mm thick, in cement mortar (1:3) on concrete/ brick surface of sunken portion, mixed with Dr Fixit pidiproof LW+ or equivalent @ 200ml/50Kg of cement complete all as specified and directed by Engr in Charge.
M&L for applying 2 coats of flexible polymer acrylic water proofing coating, 1mm thick (Dry film in two coats) using Dr Fixit pidifin 2K of M/S Pidilite Industries or equivalent including necessary pond testing for 48 hrs in sunken portion complete all as specified and directed by Engr in Charge.
M&L for Plain cement concrete (1:5:10), type E2, using 40mm graded stone aggregate in sunken floor surface finished fair and complete all as specified and directed by Engr in Charge.
M&L for treatment to sunken stab by applying primer @ 0.5 Kg/Sqm over the prepared suface and hot blown cutback bitumen @ 0.70 Kg/Sqm providing and laying polythene film 150 microne thick with cutback bitumen adhesive on min 15cm overlap complete all as specified and directed by Engr in Charge.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 15 mm dia complete all as specified and directed by Engr in Charge.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 20 mm dia complete all as specified and directed by Engr in Charge.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 25 mm dia complete all as specified and directed by Engr in Charge.
S & F 15 mm dia GI tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr in Charge.
S & F 20 mm dia GI tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr in Charge.
S & F 25 mm dia GI tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engr in Charge.
S&F in repair for 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr in Charge.
S&F in repair for 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engr in Charge.
S&F in repairs for Vitreous China wash basin, size 550 x 400mm, white, flat back, with waste, coupling, chain and plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and directed by Engr in Charge.
S&F in repairs for Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed by Engr in Charge.
S&F in repair vitreous china wash down water closet pan (pedestal pattern ), white (excluding fixing bolts, flushing cistern and flush pipe), including connection to drain (or out going pipe) and to flushing pipe, antisyphonage pipe etc. complete all as specified and directed by Engr in Charge.
S&F in repairs for Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe), with integral foot rest including provision of lime concrete bedding, connection to trap and anti syphonage pipe etc complete including making good to floor complete all as specified and directed by Engr in Charge.
S&F in repairs for 10 litre capacity PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed by Engr in Charge.
S&F in repairs for toilet paper holder of vitreous china fixed to walls with chromium lated (CP) brass screws complete all as specified and directed by Engr in Charge.
S&F in repairs CP Jet spray (Butterfly) with 1Mtr tube complete all as specified and directed by Engr in Charge.
S&F in repairs, 15mm bore, PVC connecting pipe 450mm long with PTMT nuts at both ends complete all as specified and directed by Engr in Charge.
S&F in repair PVC (SWR) floor trap/nahani traps/ Gully traps, 75mm dia bore plain with grating including jointing with solvent cement all as specified complete all as specified and directed by Engr in Charge.
S&F in repairs, 15mm bore, bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engr in Charge.
S&F in repairs 15 mm bore, Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engr in Charge.
S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60 cm long between flanges complete all as specified and directed by Engr in Charge.
S&F in repairs CP brass shower rose with swival joints complete fancy type for 15mm bore pipe, fixed as in repairs, complete all as specified and directed by Engr in Charge.
S & F in repairs for Stop valves, 15mm bore fancy type, chromium plated (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr in Charge.
Taking down PVC pipes including all fittings like shoes, bends, swan necks etc of any dia complete all as specified and directed by Engr in Charge.
S&F 110 mm dia PVC (SWR) pipes single sockets, in any length with rubber ring joints, laid in wall complete all as specified and directed by Engr in Charge.
S&F PVC (SWR) bend any radius for 110 mm bore pipe incl jointing material complete all as specified and directed by Engr in Charge.
S & F PVC ( SWR ) junction single, ( double T ) equal or unequal of 110 mm bore complete all as specified and directed by Engr in Charge.
S & F PVC ( SWR ) vent cowl 110 mm bore complete all as specified and directed by Engr in Charge.
S&F PVC 75mm dia (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed by Engr in Charge.
S&F PVC (SWR) bend any radius for 75 mm bore pipe incl jointing material complete all as specified and directed by Engr in Charge.
S & F PVC ( SWR ) junction single, (Double T+B61) equal or unequal of 75 mm bore complete all as specified and directed by Engr in Charge.
S & F PVC ( SWR ) vent cowl 75 mm bore complete all as specified and directed by Engr in Charge.
Demolition of brick work built in cement mortar complete all as specified and directed by Engr in Charge.
M & L brick work with sub class 'B' bricks straight or curved on plan to any radius built in CM 1 : 4 in half brick thick walls complete all as specified and directed by Engr in Charge.
M & L PCC 1 : 2 : 4 Type B1 ( 20 mm graded aggregate) as in providing, cement concrete cills, steps, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs complete all as specified and directed by Engr in Charge.
S & F 32 mm dia GI tubing 'light grade' with all fittings and fixed complete to walls or laid in floors as a spout pipe complete all as specified and directed by Engr in Charge.
S & F Compound girders & stanchions, lattice griders, aerial masts, staging for water tanks & the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates etc. of Gde Fe 410-W (Gde- E-250) Qty-A complete all as specified and directed by Engr in Charge.
M & L preparation of new painting steel surface with two coats of synthetic enamel paint over a coat of red oxide primer over newly prepared steel surface complete all as specified and directed by Engr in Charge.
M & L preparation of old painting steel surface with one coats of synthetic enamel paint prepared steel surface complete all as specified and directed by Engr in Charge.
S&F in repairs, rotational moulded polythene water storage tanks, double layered (Cylindrical vertical with closed top) of capacity 1000 lit, hoisted and fixed in position as in repair including taking down old tanks complete all as specified and directed by Engr in Charge.
S&F in repairs, rotational moulded polythene water storage tanks, double layered (Cylindrical vertical with closed top) of capacity 500 lit, hoisted and fixed in position as in repair including taking down old tanks complete all as specified and directed by Engr in Charge.
S&F 20mm bore ball brass valves high pressure, with polythene float & fly nuts complete, screwed for iron pipe or brass ferrule complete all as specified and directed by Engr in Charge.
M & L 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection / hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed by Engr in Charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets , light fittings etc. removing material for taking credit and making good distrubed surfaces to walls, floors etc complete all as specified and directed by Engr in Charge.
M&L for point wiring with single core PVC insulated 1100V grade cable with multistranded copper conductor of size 1.5 Sq. mm (Nominal area) drawn in and PVC conduit (medium grade) of suitable size with all fittings and accessories including sunken box/PVC rectangular board of suitable size,and drawing continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 sqmm complete all as specified and directed. (a) For one light/fan point controlled by one, one way Switch complete all as specified and directed by Engr in Charge.
(b) For one 3 pin socket outlet 5/6 Amps on indepented board complete all as specified and directed by Engr in Charge.
M&L for point wiring with single core PVC insulated 1100V grade cable with multistranded copper conductor of size2.5 Sq. mm (Nominal area) drawn in and including non metallic rigid PVC concealed conduit, medium grade ISI marked not less than 20 mm dia, concealed in wall, ceiling with saddles, screw & Plugs with all fittings including tee, junction boxes and drawing continuous earth wire of PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 2.5 sqmm and terminated in and including sunken box for modular switches/sockets, regulators etc complete all as specified and directed. S&F switch piano flush type single pole, one way 5 Amps.
S&F switch piano flush type single pole, one way 5 Amps complete all as specified and directed by Engr in Charge.
S&F socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and directed by Engr in Charge.
S&f switch socket combination (ISI marked) 5/15 Amps, flush type, 240 volts complete all as specified and directed by Engr in Charge.
M&L for ceiling rose 3 phase/PVC/ Polycarbonate, isolated body complete all as specified and directed by Engr in Charge.
S & F LED light fitting fixture 20W, 6500K, 2000 lm decorative ultra slim with co extruded channel in thermally conductive material with plastic housing, heat sink, environmental friendly having power factor >0.95, surge protection 2.5KV energy efficient ready to use complete all as specified. Make-Wipro/Philips/GE complete all as specified and directed by Engr in Charge.
S & F LED light fitting fixture 2 Feet, 10W, 6500K, 2000 lm decorative ultra slim with co extruded channel in thermally conductive material with plastic housing, heat sink, environmental friendly having power factor >0.95, surge protection 2.5KV energy efficient ready to use complete all as specified. Make-Wipro/Philips/GE complete all as specified and directed by Engr in Charge.
Material and labour for sub main wiring with two single core 6.0 sqmm FRLS, ISI marked PVC insulated multi stranded, unsheathed copper conductor cable and one single core unsheathed FRLS , ISI marked, PVC multistranded copper conductor cable of size 6 sqmm green colour as earth lead including PVC conduit/ casing capping of suitable size complete all as specified and directed, including taking down unservicable one.(Note: two run of 6.0 sqmm cable , one run of earth wire of 6 sqmm and one run of PVC casing capping shall be measured as one RM).Make- Cable- Finolex/RR cable/Havells, PVC Casing Capping- Presto plast/Finolex/Kalinga complete all as specified and directed by Engr in Charge.
S&F of VTPN distribution board iron clad, double door with IP-43 IK-09 protection suitable for 415 Volts 3 phase 50 C/s 4 way, MCCB as incommer and MCB as outgoing with appropriate size of copper bus bar and neutral link complete with one MCCB 4 pole 415 Volts 160 Amps rating with rupturing cap 25 kA with thermal magnetic release and 12 Nos of MCB SP 63 Amps 'C' curve type of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and directed. Make :Cat Part No.VYV04DM-P of Hager or technocommercially equivalent make of Legrand / Schenider complete all as specified and directed by Engr in Charge.
Supply and fix MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 6 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed including taking down. Make: Havells/ Schnieder/GE complete all as specified and directed by Engr in Charge.
Supply and fix Isolator DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed including taking down old one. Make: Havells/Schnieder/GE complete all as specified and directed by Engr in Charge.
Supply and fix Isolator DP, 240 Volts, 32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed including taking down old one. Make: Havells/Schnieder/GE complete all as specified and directed by Engr in Charge.
Supply and fix isolator SP, 240 Volt, 6-32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed iIncluding taking down old one. Make: Havells / Schnieder/GE complete all as specified and directed by Engr in Charge.
M/S SUHEEL CONSTRUCTIONS
M/S MARVEL ELECTRICALS
M/S Tajamul Ah Buchh
M/S Vivek Gupta and Co
M/s Lal Enterprises
M/S GHULAM AHMAD WANI
M/S MIR AND CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .