Loading…
Loading…
Tender Value
₹13.9 L
EMD Value
₹28,000
Closing Date
17 Jul 2026, 5:00 pm5d left
EXECUTIVE ENGINEER
Drinking Water and Sanitation Division, Khunti
Khijur Toli SVS Group of Scheme Under Block- Torpa
2026_DWSD_116103_2
DWSD/KH-03(SVS)/2026-27 (1st Call)
Open Tender
Civil Works - Water Works
180 days
KHUNTI
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,500
₹28,000
11 Jul 2026
11 Jul 2026
18 Jul 2026
11 Jul 2026
17 Jul 2026
11 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Tola: Khijur Toli, Village: Udikel, Block: Torpa (Khijur Toli Group of SVS) Model- 3 | - | - | - | - |
| 2 | Designing, Supplying, Installation, Testing & Commissioning with all tools & Parts of following Solar Photovoltaic (SPV) Solar Submersible D.C. Water Motor Pump Suitable for minimum 125mm x 115mm bore well as per MNRE Guideline with following specifications & accessories. | - | - | - | - |
| 3 | SPV arrays contains specified No of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual PV modules should be minimum 200 watt peak. | - | - | - | - |
| 4 | i) The SPV modules should be as per IEC-61215 and IEC 61730 part 1.0) | - | - | - | - |
| 5 | ii) All external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required. | - | - | - | - |
| 6 | iii) The PV modules should be mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & High wind pressure up to 200Km/h. | - | - | - | - |
| 7 | iv) The module mounting structure should be hot dip galvanized according to IS 4759. | - | - | - | - |
| 8 | v) To enhance the performance of SPV water pumping system & arrangement for seasonal tilt angle Adjustment should be provided | - | - | - | - |
| 9 | vi) Necessary arrangement should be provided in controller automatic start-run-stop through out the day with water level detection system. (As per MNRE Specification) | - | - | - | - |
| 10 | vii) Necessary protection such as lightening arrestor etc. should be provided to protect the controller & SPV | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
term_cond.pdf
Tender Documents • 2.38 MB
BOQ_156956.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid