Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | ₹18.5 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹21.0 L+₹2.5 L (13.5%)Rejected-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹21.0 L+₹2.5 L (13.5%) | L2 | Rejected-AOC NOT LOWEST |
| 3 | L3₹23.7 L+₹5.3 L (28.5%)Rejected-AOC | ₹23.7 L+₹5.3 L (28.5%) | L3 | Rejected-AOC NOT LOWEST |
| 4 | L4₹24.7 L+₹6.2 L (33.8%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹24.7 L+₹6.2 L (33.8%) | L4 | Rejected-AOC NOT LOWEST |
| 5 | L5₹28.9 L+₹10.5 L (56.6%)Rejected-AOC | ₹28.9 L+₹10.5 L (56.6%) | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
8 Nov 2022, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD,MUMBAI-400088
REPAIR/MAINTENANCE OF LT UG CABLE AND ALLIED WORKS AT MANKHURD AREA AND REPAIR/MAINTENANCE OF CAPACITOR PANEL, LT PANEL AND ALLIED WORKS AT MANKHURD AREA UNDER GE (NW) MANKHURD
2022_MES_556714_1
8178/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (NW) MANKHURD
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹56,000
Yes
15 Feb 2023
10 Oct 2022
10 Nov 2022
10 Oct 2022
8 Nov 2022
25 Oct 2022
Amount
Excavation in trenches not exc. 1.5 metre wide and not exc. 1.50 mtr depth for laying of underground cable, erection of poles etc. and getting out in soft/loose soil including separating serviceable bricks for re-use at site obtained during excavation complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removal of surplus soil not exc 50mtr distance and depositing where directed.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified..
Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid Note :- Serviceable cable cover obtained from Ser Item No 1 shall be reused.
M & L for sand cushioning by spreading in trenches fine crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Taking out only old unserviceable underground cable XLPE insulated, PVC sheathed armoured heavy duty aluminium conductor LT 1100 Volts grade of size 3.5 core 400 sqmm, fixed on pole, wall and laid in tranches etc after disconnecting complete all as specified and directed. (Note :- Excavation and earth work will be measured and paid seprately)
-Ditto- all as per item No 7 above but 35 Sqmm 3.5 Core -do-
-Ditto- all as per item No 7 above but 240 Sqmm 3.5 Core -do-
-Ditto- all as per item No 7 above but 150 Sqmm 3.5 Core -do-
-Ditto- all as per item No 7 above but 120 Sqmm 3.5 Core -do-
-Ditto- all as per item No 7 above but 95 Sqmm 3.5 Core -do-
-Ditto- all as per item No 7 above but 70 Sqmm 3.5 Core -do-
-Ditto- all as per item No 7 above but 50 Sqmm 3.5 Core -do-
-Ditto- all as per item No 7 above but 25 Sqmm 3.5 Core -do-
-Ditto- all as per item No 7 above but 16 Sqmm 4 Core -do-
-Ditto- all as per item No 7 above but 10 Sqmm 3 Core -do-
-Ditto- all as per item No 7 above but 6 Sqmm 3 Core -do-
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 95 Sqmm 3.5 core in trenches, along the wall including necessary connection and providing cable lugs as required including disconnection/taking down of existing unsvcable all as specified.
-Ditto- all as per item No 18 above but 70 Sqmm 3.5 Core -do-
-Ditto- all as per item No 18 above but 50 Sqmm 3.5 Core -do-
-Ditto- all as per item No 18 above but 25 Sqmm 3.5 Core -do-
-Ditto- all as per item No 18 above but 16 Sqmm 4 Core -do-
-Ditto- all as per item No 18 above but 10 Sqmm 3 Core -do-
-Ditto- all as per item No 18 above but 6 Sqmm 3 Core -do-
Laying and fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 400 Sqmm 3.5 core in trenches, along the wall including necessary connection and providing cable lugs as required including disconnection/taking down of existing unsvcable all as specified.(Note :- Cable will be issued under schedule 'B' Store under free for fixing.)
-Ditto- all as per item No 25 above but 240 Sqmm 3.5 Core -do-
-Ditto- all as per item No 25 above but 150 Sqmm 3.5 Core -do-
-Ditto- all as per item No 25 above but 120 Sqmm 3.5 Core -do-
-Ditto- all as per item No 25 above but 35 Sqmm 3.5 Core -do-
M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLE/PILC/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core up to to 50 Sqmm incl taking down existing terminal joints. Make : Reychem/3-M/M-Seal
-Ditto- all as per item No 30 above but 3.5/4 core 70 Sqmm to 150 Sqmm size -do-
-Ditto- all as per item No 30 here-in-before but 3.5/4 core 185 Sqmm to 400 Sqmm size -do-
S& F in replacement of GI pipe medium grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protection including necessary fittings , clamps for supports, etc all as directed by Engineer in charge.
Supply and fix Power Capacitors of Rating 25 KVAR 415 Volt in repairs Naturally air cooled Double dielectric heavy duty, MPP type 440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR conforming to IS 13340 and 13341 ISI Marked all as specified.
All as per item No 34 above but Power Capacitors of Rating 20 KVAR 415 Volt
All as per item No 34 above but Power Capacitors of Rating 15 KVAR 415 Volt
All as per item No 34 above but Power Capacitors of Rating 10 KVAR 415 Volt
All as per item No 34 above but Power Capacitors of Rating 7.5 KVAR 415 Volt
All as per item No 34 here in before but Power Capacitors of Rating 5 KVAR 415 Volt
Equipment and labour for servicing of ACB including drawing/taking out from LT Panel, cleaning the Contacts, checking the breaker accessories, replacing the burnt out control wiring, burnt fuse units, old unsversiable spring units for proper function and carrying out ratio test by applying primary injection all for LT ACB 630 Amps to 800 Amps and refixing the breaker in position and testing all as directed by Engineer in Chare at site Note :The Contractor shall brought all T & P and testing equipments.
Supply and fix in repairs power factor controller relay 8 Stage RPM 8, 415 volts, 50 cycles suitable for manual / automatic operation with indication for each stage, power factor adjustment setting knob / screw, display. Cat no -ETACONM008R Of L & T or equivalent from Conzerv / Neptune /SCHNIDER/SYNTRON/ABB/ C&S
M & L for testing of APFC panel for proper functioning in manual & auto mode, including re-wiring the burnt out wires, replacing the wiring ducts/casing Capping, fuse units and cleaning and testing complete all as specified and directed.
Supply and Fix in replacement of Contactor Three Pole 415 volts 25 Amps AC 3 Rating, Conforming to Type MNX 25 & Cat No - CS94110 of L & T or Equivalentt from Schnider Electric, ABB including add on Blocks suitable for driving POWER Capacitors, including making addition/Alternation to existing Wiring/circuit system
All as per item No 45 above but Contactor Three Pole 415 volts 32 Amps AC 3 Rating Conforming to Type - MNX 32 & Cat no - CS94111 of L & T or equivalent from Schnider Electric, ABB/ C&S
All as per item No 45 above but Contactor Three Pole 415 volts 40 Amps AC 3 RatingConforming to Type - MNX - 40 & Cat no - CS94190 of L & T or equivalent from Schnider Electric/ABB/ C&S
All as per item No 45 above but Contactor Three Pole 415 volts 50 Amps AC 3 Rating Conforming to Type -MNX - 50 & Cat no ST19001 of L & T or equivalent from Schnider Electric/ABB/ C&S
All as per item No 45 above but Contactor Three Pole 415 volts 70 Amps AC 3 Rating Conforming to Type - MNX - 70 & Cat no - ST19002 of L & T or equivalent from Schnider Electric/ABB/ C&S
All as per item No 45 above but Contactor Three Pole 415 volts 110 Amps rating Conforming to Type - MNX - 110 & Cat no - CS94137 of L & T or equivalent from Schnider Electric/ABB/ C&S
All as per item No 45 above but Contactor Three Pole 415 volts 140 Amps AC 3 Rating Conforming to Type - MNX 140 Cat no - CS94138 of L & T or equivalent from Schnider Electric/ABB/ C&S
S & F in repair MCCB 400 Amps, 36 KA Triple Pole 415 Volts including connecting up complete in existing panel with Lugs/Glands all as specified and directed.
All as per item No 52 above but MCCB 250 Amps, 25/36 kA Triple Pole 415 Volts
All as per item No 52 above but MCCB 200 Amps, 25/36 kA Triple Pole 415 Volts
All as per item No 52 above but MCCB 63 Amps, 16 kA Triple Pole 415 Volts
Supply, fix and testing Euroload Four pole onload changeover with advanced Neutral of current rating 250 Amps of open excution cat code No IHCNFO0250 of Make - Havells/C & S / L & T
Supply and fix in repair add on Blocks suitable for Power contactors of range 25 Amps to 140 amps (MNX 25 to MNX 140 including making addition/Alternation to existing Wiring/circuit system all of Make- L&Tor equivalent from Schnider Electric/ABB/ C&S
Supply and Fix in repairs 230 Volts push buttons complete of colour red/ green with NO/NC elements. Makes : C & S / L & T/ Schneider
S & F in repairs 230 Volts indication lamp complete(R Y B ) for mounting on LT panel
S & F in repair Closing coil 415 V/230 V for ACB of rating from 630 Amps to 800 Amps all as specified.
S & F in repair Shunt Release 415 V/230 for ACB of rating from 630 Amps to 800 Amps all as specified
M & L for rewiring of old burnt out copper wiring in LT Panels/LT Feeder, replacing of cable Glands, cable lugs, bus bar link, connectors, insulators, door hinges, panel door locks & scrapping of old paints & applying two coats of paint all as directed.
M&L in repairs of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 2.50 M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification.
S&F in repairs GI strip size 25 x 4 mm all as directed including welding brazing and taking down of old copper strips as required at site
M & L spray painting inside, outside complete to the LT panel boards outdoor type of size not exceeding 2.0 Mtr width 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface incl lettering of I/C & (O/G) feeders and danger notice board complete.
Supply and installed factory made feeder pillar box complete made out of MS sheet 3.15 mm thick duly painted internally/externally powder coated with paint including 4 Nos busbar (3 phase) made out of copper strip 32 x 3.5 mm with front door operated (size of feeder pilar box 0.60 x 0.60 x 0.3 m) on suitable size of PCC foundation complete with including taking down old UNSV feeder pillar box of any description/specification complete all as specified and directed.
Supply and fix in repairs stainless steel cable glands required for cable entry in Panel of size from 10 sqmm to 50 sqmm etc. complete all as specified and directed.
-Ditto- all as per item No 74 above but for 70 sqmm to 120 sqmm -do-
-Ditto- all as per item No 74 above but for 150 sqmm to 300 sqmm -do-
Supply and fix in repairs alluminium cable lugs of size 16 sqmm to 50 sqmm for cable connection etc. complete all as specified and directed.
Supply only CTC/ CRC solution spray to remove out the moisture and corrosion content from electrical equipement complete all as specified and directed.
Supply only cotton waste industrial type for cleaning of electrical equipment , Panel board etc complete all as specified and directed.
Supply and fix analog time switch FM/1 Quartz, supply voltage 240 Volts 50 Hz, Type- QT(DAILY) of Cat No J648B1-1 of Make L&T.
M&L for testing of old earthing using calibrated earth tester & submitting result to Engr -in -charge all as directed. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 20Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted.
Material & Labour for service cable of PVC insulated unsheathed weather proof twin core aluminium standed conductor 4 Sqmm 1100 volts grade for street light service cable as directed.
Supply only 2.5 Sqmm weather proof flat, single core stranded copper conductor cable 1100 Volts grade for connecting street/Security light complete including connection and testing all as specified and directed.
Supply & Fix 8/9watts LED Bollard Garden light fittings with efficient high output LED, Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation 0.3 Meter x 0.3 Meter x 0.3Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, provision of GI bend of size 50 mm dia in the PCC for cable entry , the Fitting Shall Conform to Cat No - CONEBL8WLED857SSYMTOPC of Havells or Equivalent from Bajaj/Jaguar/Wipro Note : A sum of Rs 34685.00 towards sch of credit shall be deducated to arrive the contract sum.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .