| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC | ₹32.7 L Quoted ₹33.7 L | L1 | Accepted-AOC Accepted for lowest bid quoted |
| 2 | L2₹39.7 L+₹6.0 L (17.7%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | ₹39.7 L+₹6.0 L (17.7%) | L2 | Rejected-Finance Highest bid quoted |
| 3 | Rejected-Technical | - | - | Rejected-Technical Rejected due to not enlisted in apprpriate cat i.e. b (i) |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Jan 2023, 6:00 pmClosed
GE (AF) Gurgaon
Gurgaon
CERTAIN REPAIRS TO BARBED WIRE FENCING GATES SECURITY WALL STROM WATER DRAIN FOOTPATH HARDSTANDING AND REPAIR REPLACEMENT AND CLEANING OF SEWAGE LINE MANHOLE SEPTIC TANK SOAKAGE WELL ETC AT AFSSR GURGAON AND REPAIR MAINTENANCE AND IMPROVEMENT DEVELO
2022_MES_570436_1
CA NO GE/GUR-/NIT-54/2022-23
Open Tender
Miscellaneous Works
Piece-work
240 days
GE (AF) Gurgaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹90,000
21 Feb 2023
21 Dec 2022
20 Jan 2023
21 Dec 2022
18 Jan 2023
4 Jan 2023
Amount
M&L for Removing Complaint of Blockage (viz Blockage in Bath, Kitchen, WC & Drainage in Traps/Line from Trap to 1st Manhole, Blockage in Sewage Line from 1st Manhole to Septic Tank, Cleaning of Manhole) by deploying Trades Men as per Stipulated Time Frame from 9.00 AM to 5.00 PM and maintaining proper Records of COMPLETED and PENDING Complaints including updating status of Complaints through SMS/Manually for AFSSR, complete all as specified and as directed. NOTE : FOR ITEM No. 1 (a) If the Complaint is not attended/removed within a Day the Recovery will be levied on the Contractor for non-complelion of the Complaint at the Rate of Recovery included in Tender Document here-in-after. (b) It is mandatory on the Part of Contractor to deploy minimum 2 No. of Safaiwala/Mazdoor with requisite T&P throughout the Entire Contract Period. However required manpower and T & P, if required more to meet the requirement as mentioned in Item No. 1 is also to be arranged by the Contractor at his own Arrangements and Cost. Quoted Rates shall be deemed to include this factor and nothing Extra will be admissible on this account other than Quoted Rates for Item No. 1. In case of any dispute on this factor, the decision of Accepting Officer shall be final, conclusive and binding.
M&L for Clearning Choked Sewer Lines of upto 150mm dia of any depth, Manually or thorough Mechanical Appliances and Making Sewer Line Functional complete including Working Under Foul Condition and depositing the sludge, rubbish, etc. off the Premises outside the MOD/AF Land or Sewage Treatment Plant, complete all as specified and as directed.
M&L for Clearning Choked Sewer Lines of 200mm to 250mm dia of any depth, Manually or thorough Mechanical Appliances and Making Sewer Line Functional complete including Working Under Foul Condition and depositing the sludge, rubbish, etc. off the Premises outside the MOD/AF Land or Sewage Treatment Plant, complete all as specified and as directed. NOTE : FOR ITEM No. 2&3 (a) If the Complaint is not attended within a Day the Recovery will be levied on the Contractor for non-complelion of the Complaint at the rate of recovery included in Tender document here-in-after. (b) It is mandatory on the Part of Contractor to deploy minimum 2 No. of Safaiwala/Mazdoor with requisite T&P throughout the Entire Contract Period. However required manpower and T & P, if required more to meet the requirement as mentioned in Item No. 2 & 3 is also to be arranged by the Contractor at his own Arrangements and Cost. Quoted Rates shall be deemed to include this factor and nothing Extra will be admissible on this account other than Quoted Rates for Item No. 2 & 3. In case of any dispute on this factor, the decision of Accepting Officer shall be final, conclusive and binding.
M&L for Removing Manhole Cover and Desludging/Desilting/Cleaning of existing Manholes of depth upto 1.50 Metre filled with Sludge by means of Manually or through Mechanical Appliances complete, Working Under Foul Condition and resetting the Manholes Cover in same Position and depositing and removal of Sludge, Rubbish, etc. off the Premises Outside Defence Land, complete all as specified and as directed.
M&L for Removing Manhole Cover and Desludging/Desilting/Cleaning of existing Manholes of depth exc. 1.50 Metre and not exc. 4.50 Metre filled with Sludge by means of Manually or through Mechanical Appliances complete, Working Under Foul Condition and resetting the Manholes Cover in Position and depositing and removal of Sludge, Rubbish, etc. off the Premises Outside Defence Land, complete all as specified and as directed.
M&L for Dewatering Sludge from Soakage Wells by Pumping out as required to keep the Complete Sewage System in order and as to avoid any Over flowing of Sewage Water including removing of Soak Well water pumped out as such out side of Defence Land by means of Pumps and Tankers (Capacity of Water Tanker shall be 5000 Litres) as required including Operating and Supervisory Staff(s) so as to keep the whole Station area Pollution Free, complete all as specified and as directed. NOTE : Each Trip of Tanker to be taken Out side of MOD/AF Land in presence of JE in-Charge. This includes deployment of necessary T&P and nothing shall be Paid Extra.
M&L for Desilting/Cleaning of Septic Tank and the like including Sludge Water and Solids Mechanically by HCV Mounted Suction Discharge Machine having Blow Back Facility with Sludge Tank and disposal of the same to Outside of MD/AF Land, complete all as specified and as directed. NOTE : Disilting/Cleaning of Septic Tanks shall be done for TWICE in the entire Contract Period.
Cleaning of Sewage pipe line (RCC/SGSW) of Upto 300mm bore by means of sewage cleaning jet machine / compressors/Drain jetters Pumps and clean out the sluge /liquid mud or any other obstruction material to any depth including nesesarry rodding, working in foul position and depositing of sludge/silt/liquid mud beyond the premises of MOD land etc complete with all specified pressure rating and complete all as directed by Enge-in-charge. Note :- All other arrengment of electricity, water, etc included in quoted cost. Nothing will be paid extra on this account.
Taking down PVC soil waste/rain water pipes/bends ( any size or pattern,fixed in any position or laid in floor/earth) including all fittings head shoes etc complete all as specified and as directed.
S&F 110mm bore PVC(SWR) pipes single socketed in any length medium Grade fixed to walls in any position or laid in floor/earth with dash true nuts and bolts at every 2mtr length including) including all fittings complete all as specified and directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) bends any radius With or without access door complete all as specified and directed by Engr-in-charge.
M&L for Stack Clamp for Pipe 75mm/110mm/150mm bore (dia), made out of Flat Iron 50mmx5mm and 16mm dia Round Iron Stay including Bolts and Nuts and securing Ends of Stays to Wall or Roof and Fixed-in-repairs, complete all as specified and as directed.
Excavation in trenches n.exc 1.50 m wide and n.exc 1.50 m in depth for foundation or shafts,wells,cesspits,manholes,pier holes,cable laying,sewage/water lines etc complete and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches n.exe 1.5m wide and exc 1.5 mtr but not exc 3.0 mtr in depth for foundation or shafts,wells,cesspits,manholes,pier holes,cable laying,sewage/water lines etc complete and getting out in soft/loose soil complete all as specified and directed.
Demolition and breaking of drain pipes of 150 mm dia (Salt galzed ware, AC or Reinforced concrete set in cement mortar etc complete all as specified and as directed
Demolition and breaking of drain pipes of 200 mm dia (Salt galzed ware, AC or Reinforced concrete set in cement mortar etc complete all as directed
M&L for reinforced cement concrete drain pipes of 150 mm dia bore class NP-2, laid and jointed complete with collars etc complete all as specified and as directed.
M&L for reinforced cement concrete drain pipes of 200 mm dia bore class NP-2, laid and jointed complete with collars etc complete all as specified and as directed.
M&L for concrete bed to drain pipes 150 mm bore including packing under and hunching against the sides of pipe, after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregagte) etc complete all as specified and as directed
M&L for concrete bed to drain pipes 200 mm bore including packing under and hunching against the sides of pipe, after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregagte) etc complete all as specified and as directed
Returning filling in including spreading leveling watering and well ramming in layer not exc 25cm thick. Complete all as specified and as directed
Removal of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.50 mtr above the starting point complete all as specified and as directed
Demolition of cement concrete (reinforced) in any description and in any postion not otherwise specifically provided for etc complete all as directed
M&L for Separating, scraping and cleaning of reinforcement (Demolition of concrete measured separately) complete all as specified and directed
M&L for Pre-Cast reinforced cement concrete 1:2:4 type B-1 with using 20 mm graded crushed stone aggregates as in cover slabs (for manholes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plan faces set in cement mortar (1:4) including necessary use and waste form work etc complete all as specified and as directed Note - Reinforcement shall be measured and paid separetly
M&L for TMT bars upto 10mm dia as in reinforcement for concrete, cut to length, bent to shape required including cranking , bending spiraly for hooping for columns, hooking with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and as directed
S&F framed work such as grills, gratings etc with ends of bars shouldered and or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walk way railing frame work of water tanks and similar work confiming to Fe.290, Gde E-165 etc complete all as specified and as directed
Taking down cement plaster of any description on brick walls, etc including raking out joints, hacking for key scrubbing down with water etc.
M&L for Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement, complete all as specified.
Getting out soft/loose soil from existing Drain of any size complete all as specified and directed.
Dismantling of brickwork or stone boulder masonry, built in cement mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of cement Concrete/lime concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in bed of drain foundation, filling and mass concrete complete all as specified and directed.
M&L for Brick work with sub class "B" Old size bricks, straight or curved on plan to any radius in cement mortar (1:4) as in half brick wall and pointed flush in same mortar as work proceeds on one side complete all as specified.
M&L Brick work with sub class ‘B’ bricks(old size brick), straight or curved on plan exc 6 mtr mean radius built in cement mortar (1:4) and external face of brick work pointed flush in the same mortar as the work proceeds, complete all as specified and as directed
M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone agggregate as in surface channel drain and bedding including necessary form work and weathering, slightly rounded or chemfered angles complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds,mitred/stopped ends etc complete all as specified and as directed
M&L for cement concrete 1:2:4 type, B1 (using 20 mm graded crushed stone aggregates) as in copings including necessary use and waste of formwork, weathering, slightly rounded or chamfered angles and throating etc complete all as specified and as directed
Demolition of cement concrete in ground floors and paving not exceeding 15 cm thickness ( below or above ground level) and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) in sub base of floor complete all as specified and as directed .
M&L for Kerb stone of pre-cast PCC (1:2:4) type B-1, using 20mm graded stone aggregates, solid block or slab of size 30 cm x 20cm x 45 cm laid dry on end vertically as in road edging, jointed in cement mortar (1:6) and struck flush complete including necessary excavation, earthwork removal of spoil and temping around all as specified and as directed by Engr-in-Charge.
M&L for refixing of Kerb stone made of precast concrete solid block or slab incl taking out blocks from any position laid dry on end vertically as in road edging, jointed in cement mortar (1:6) and struck flush complete including necessary excavation, earthwork removal of spoil and temping around all as specified and as directed by Engr-in-Charge.
M&L for 25mm thick sand cushioning including watering and consolidations etc complete all as specified and directed.
M&L for Rubber Pressed, Glossy finsh Pre-Cast concrete interlocking coloured paving block of glass fibre reinforced vibro compacted any shape and size conforming to IS-15658:2006 of 60mm thickness made with M35 grade concrete match with grey cement and pigment etc complete all as specified and directed.
M&L for preparation of old painted/new concrete surface of kerb stone and applying Two coats of synthetic enamel paint etc complete all as specified and as directed
M&L for Rough Cast plaster on brick walls consisting under coat of cement and sand mortar 1:3 not less than 10mm thick and while it is still in plastic state the Rough cast mixture consisting of crushed stone or fine gravel mixed of size 6mm with coarse sand and cement in the ratio 1:1:1 shall be applied and finish even, complete all as specified and directed
M& L preparing newly for rough cast plastered surfaces of walls and applying two coat of arcylic weather coat exterior paint with approved tint over a coat of primer (as per manufacturer instructions) ,complete all as per specified and directed
Dismantaling old barbed wire of any Description complete all as Specified.
Dismantaling concentrina coil of any type complete all as Specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for incl taking out embedded portiojn in Concrete, brick work etc and making good disturbed area complete all as specified.
M&L for galvanised, 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining & fixing to any type of standard nails, straining bolts including securing or tying at crossings with and provision of galvanised steel wire, staples or steel pins etc (each line of wire to be measured) all as specified and directed.
S & F hot dipped galvanised concertina razer tape coil 600mm dia, spring steel high tensile centre core wire 2.5 mm dia having 200-250gm zinc coating, 0.5 mm thick razer sheet having 90-120gm, zinc coating & min 10 mm width ( before wraping centre core wire),with GI clip 1.6 mm thick complete all as specified and directed by Engineer-in-Charge
M&L for Preparing of new steel surfaces over 10cm in width or girth and painting two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr in Charge.
M&L for completely removal of the existing treatment from wall,chajjas,facia and preparing plaster surface of wall and applying two coat of exterior weather proof paint over a coat of primer etc complete all as specified and directed.
M&Lfor applying two coats of synthetic enamel painting on steel surfaces of any description including prepration of surfaces.
M&L for replacement of fire extinguisher Carbon Dioxide (CO2) type of capacity 4.5 Kgs incl fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn etc complete all as specified and directed.
M&L for replacement of fire extinguisher Dry Chemical Powder type of capacity 6 Kgs incl fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn etc complete all as specified and directed.
M&L for replacement of fire extinguisher Gas Cartridge type of capacity 9 Kgs incl fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn etc complete all as specified and directed.
Taking up or down CI Pipes including all fittings such as spigot and socket ends, bends, belows tee etc laid complete in trenches all as specififed of sizes
80mm bore
100mm bore
150mm bore,
200mm bore
Taking up or down DI water mains pipes including all fittings with spigot and socket ends and rubber tytan joints including removing out joints complete in trenches all as specified and directed of sizes :-.
100mm bore
200mm bore,
Supply, Laying and Testing of cast iron pipes with spigot and socket ends and centrifugally cast class LA, in any length, laid in trenches complete all as specified and directed of following sizes :-
80mm bore
100mm bore
150mm bore
200mm bore
Supply, Laying and Testing of DI water mains pipes including all fittings with spigot and socket ends and rubber tytan joints Class K9 in any length laid in trenches complete all as specified and directed.
100mm bore
200mm bore,
Taking up or down steel tubing and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-
15mm bore
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
100mm bore
S & F in repair steel tubing and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-
15mm bore
20mm bore
25mm bore
40mm bore
50mm bore
80mm bore
100mm bore
S & F in replacement Gun metal Gate valve with iron wheel head screwed both ends complete all as specified and as directed by the Engineer-in-Charge of sizes :-
40 mm dia
50 mm dia
20 mm dia
25 mm dia
S & F check valve heavy duty of gun metal both end threaded and leaf spring loaded vertical type including removing unserviceable foot valve from the suction pipe of the pump set complete all as specified and directed by Engr in charge of following sizes :-
100 mm dia
80 mmm dia
50 mm dia
S & F in replacement CI non return valve complete all as specified and directed by Engr in charge of following sizes :- .
150 mm dia
100 mm dia
80 mmm dia
50 mm dia
M & L for Cutting existing CI or steel tubing of any size for alterations or additions and screwing all as specified and directed by Engg-in-charge
Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and as specified and directed for the following sizes:-
900mm x 750mm x 900mm
900mm x 600mm x 1000mm
S & F in replacement Cast Iron sluice valve, class PN- 1.6 with flanged and drilled ends any pattern including necessary jointing and jointing materials complete (with rubber gaskets, bolts and nuts etc) complete all as specified and directed by Engr in charge including taking down the old worn out sluice valve complete all as specified and directed by Engr in charge for the following sizes :-
150 mm dia
100 mm dia
80 mm dia
Supply only high strength Calcium Hypochlorite based granular chlorination chemical having 60% to 70% available chlorine granuler must contain appropriate quantities of disinfectants/corrosion inhibitors to prevent encrustation/scaling in distribution, packed in 40/45 Kg plastic Drum. Make :- DECLIBAC TECHNOLOGIES, PURI CHLOR BY RAYALASEEMA, POTTER & WATTS, BRIOZING or equivalent as approved by GE
S&F, in repair, cast iron, water meter, Bulk enclosed Dry Dial type both end flanged, confirming to IS-2373, including rubber gasket joint at both ends for 100mm bore with nuts, bolts & washers and fixed in existing DI pipe line by cutting and providing flange on both sidecomplete all as specified and directed.
S & F in replacement MCB TPN of capacity 40 Amp,3 phase, AC complete all as specified and as directed by the Engineer-in-Charge.
S & F in replacement MCB TP of capacity 63 Amp,3 phase, AC complete all as specified and as directed by the Engineer-in-Charge.
S & F in replacement MCB TP of capacity 100 Amp,3 phase, AC complete all as specified and as directed by the Engineer-in-Charge.
S & F in replacement FASD starter suitable for motor of capacity of 15 HP, 3 phase, AC, 415 Volt with single phase preventer Make- L&T or equivalent complete to be fixed in existing LT panel all as specified and as directed by the Engineer-in-Charge.
S & F in replacement FASD starter suitable for motor of capacity of 25 HP, 3 phase, AC, 415 Volt, complete with single phase preventer, Make- L&T or equivalent complete to be fixed in existing LT panel all as specified and as directed by the Engineer-in-Charge.
S & F in replacement FASD starter suitable for motor of capacity of 40 HP, 3 phase, AC, 415 Volt, complete with single phase preventer , Make- L&T or equivalent complete to be fixed in existing LT panel all as specified and as directed by the Engineer-in-Charge.
S & F in replacement FASD starter suitable for motor of capacity of 60 HP, 3 phase, AC, 415 Volt, complete with single phase preventer , Make- L&T or equivalent complete to be fixed in existing LT panel all as specified and as directed by the Engineer-in-Charge.
S & F in replacement FASD starter suitable for motor of capacity of 10 HP, 3 phase, AC, 415 Volt, complete with single phase preventer, Make- L&T or equivalent complete to be fixed in existing LT panel all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement of flat submersible 3 core 6 Sqmm cable PVC insualted, unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
Lifting and lowering submirsible pump moter with the help of machine/ hydra/chain pully block with sufficent manpower including taking submersible cable dismentling and reconnectioing the pipe line including replacement of worn out/ rusted/old nuts & bolts, gasket with new proper size . Job includes cutting, welding any rusted pipe and flanges for safe working of submersible pump with motor of capacity UPTO 25 HP Note:- During lifting/lowering of pump motor from borewell if falls in the borewell then contractor will arrange to take out the pump motor without any extra cost.
M&L for CI fittings for flanged pipes upto 150 mm bore ,bends ,cross Tee any type any radius and straight connecting pieces complete all as specified and directed by Engr in charge.
M&L for repairing unserviceable submersible pump to make the pump functional, Servicing of defective submersible pump of following capacity by dismantling the pump & removing unserviceable parts and assemble the pump properly after replacements of unserviceable parts complete all as specified and as directed. Note:- (a) The quoted rates are inclusive of transporting the pump from bore well site to repair work shop & back to site. (b) The quoted rates are inclusive of any spare required including seal, bearing/bush of pump to make the pump functional irrespective of item in this schedule.
For motor of capacity 25 HP
For motor of capacity 15 HP
For motor of capacity 12.5 HP
For motor of capacity 10 HP
For motor of capacity 5 HP
M&L for rewinding of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enamelled copper winding wire. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable for the pump of following capacity complete all as specified and as directed :-
For submerible motor of capacity 25 HP
For submerible motor of capacity 15 HP
For submerible motor of capacity 12.5 HP
For submerible motor of capacity 10 HP
For submerible motor of capacity 5 HP
Supply and fixing in replacement of flat submersible 3 core 10 Sqmm cable PVC insulated unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
S & F in replacement GI Coloumn pipe of bore 50 mm and 6 meter length with socket/flange of size 50 mm dia and 5 mm thick duly screwed as well as welded on both ends , lowering and fixing into the borewell by using nuts, bolts , gasket and washers complete all as specified and diected by Eng-in-charge. Note:- Cost of welding of flange nuts,bolts & gasket is included in the unit rate.
S & F in replacement GI Coloumn pipe of bore 80 mm and 6 meter length with socket of size 80 mm dia 6 mm thick duly screwed as well as welded on both ends , lowering and fixing into the borewell by using nuts, bolts , gasket and washers complete all as specified and diected by Eng-in-charge.
Supply and fixing in replacement of fully automatic star delta starter suitable for 15 HP summersible/monoblock pump motor set AC 440V 50 Hz with single phase priventor over current, short circuit protection built in voltmeter, ammeter complete with sheet metal enclosure including fixing/mounting as per L&T Cat No MU-20 (SS9985) and dismentling old unservicable all as directed and specified. Make L&T/ BCH/Siemens
Supply and fixing in replacement of fully automatic star delta starter suitable for 25 HP summersible/monoblock pump motor set AC 440V 50 Hz with single phase priventor over current, short circuit protection built in voltmeter, ammeter complete with sheet metal enclosure including fixing/mounting as per L&T Cat No MU-G30 (CS96008) and dismentling old unservicable all as directed and specified. Make L&T/ BCH/Siemens
M&L for rectification of defective run lead joing by burning out lead joint in position including recovering lead and making new lead joint all as specified including bailing out water coming from defective joints by means of electric/diesel driven pump set, testing of the joint under full working pressure for the following CI Pipe lines all as directed by Engineer-in-charge.
200 /150mm dia
100/80 mm dia
M&L for rectification of defective rubber gasket flanged joints including replacing rubber gasket, bolts, nuts and washers for the following CI/MS pipe line.
200/150 mm dia
100/80 mm dia
M & L for development of existing deep borewell to improve yield of the borewell by using compressed air blowing method & with 25% extra capacity pump by pumping of muddy water and lifting up water complete all as directed. Note:- (a) The quoted rates are inclusive oflifting/lowerging of the pump motor from bore well. (b) During lifting/lowering of pump motor from borewell if falls in the borewell then contractor will arrange to take out the pump motor without any extra cost.
Disconnecting/removing the old unserviceable burnt parts from the FASD starters and supply and fix the new items as per exiting the model for AC 415 V,50 HZ 3 phase suitlable for lthe motors all as directed by the Engineer-in-charge.
Power Contactor MNX-25 with Aux contacts 1 NO + 21NC of range AC1 - 45 A & AC3 - 25 A of Make - L&T Cat No. CS94110
Power Contactor MNX-40 with Aux contacts 1 NO + 1 NC of range AC1 - 55 A & AC3 - 40 A of Make - L&T Cat No. CS94190
Power Contactor MNX-45 with Aux contacts 2 NO + 2 NC of range AC1 - 80 A & AC3 - 45 A of Make - L&T Cat No. ST19000
Power Contactor MNX-50 with Aux contacts 2 NO + 2 NC of range AC1 - 80 A & AC3 - 50 A of Make - L&T Cat No. ST19001
Power Contactor MNX-70 with Aux contacts 2 NO + 2 NC of range AC1 - 70 A & AC3 - 100 A of Make - L&T Cat No. ST19002
Power Contactor MNX-80 with Aux contacts 2 NO + 2 NC of range AC1 - 80 A & AC3 - 100 A of Make - L&T Cat No. ST19003
Bimetal ver load relay MN-5 type directly mounted/operated of range 30-50 Amp of Make L&T Cat No. SS94136OOGO
Bimetal ver load relay MN-5 type directly mounted/operated of range 66-110 Amp of Make L&T Cat No. SS94137OOKO
single phase preventer suitable for 3 HP to 50 HP pump sets
Taking down the old deterioted/damaged rubber mats from the sub stations, supply & lay synthetic insulating rubber matsof size: 2m x 1mx 19 mm for up to 3.3 KV all as specified & directed MAKE: Jyothi/Electromat
M&L for earthling complete with galvanised iron earth plate electrode of the size 600 mm x 600 mm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip 32 x 6 mm by means of bolts ,nuts.chuck nuts and washers of galvanised iron or .steel watering pipe of 20 mm bore , galvanised iron medium grade of 40 mm bore galvanised iron light grade of earth wire protection including all excavation earth work in any type of soil ,PCC pit with RCC pit cover , charcoal,salt,funnel complete all as shown in electrical plate No-3 of SSR Part-I & Testing on completion. Note: Quoted rates shall be including for earth strip with protection pipe upto 7.5 mtr length.
M&L for removal and un-installation of existing solar leaked tank from the system
S&F, installation, testing and commissioning of new steel solar water heater tank of 200 litres capacity complete in replacement of existing unsserviceable/leaked solar tank with insulation and inlet and outlet connection for 6 Nos Md accn and over flow pipes including all GI fittings i.e GI Socket, Elbow, Union, Plug, rubber gasket etc as required at site complete all as specified and directed.
M&L De-scaling of existing solar flat plate collector brazing where ever required, all fittings and gaskets in place.
S&F insulation of existing hot water line with 9mm Nitrile insulation for better performace of the solar water heater.
SITC for fresh hose pipe for the solar water heaer system from solar water tank to collectors.
M&L for provision for electrical back up heating element 3 KW suitable for Solar heating system including electrical connection with DB and all accessories required for smooth functioning electrical backup complete all as specified and directed.
M&L for submain wiring in PVC conduit 2 x 6 Sqmm and 1 x 4 Sqmm as earth wire copper conductor multistanded, as PVC conduit not less than 20mm dia complete all as specified and directed.
Taking out unserviceable fire hydrant door complete and S&F New door of size 2.10m x 0.75m including chowkhat made of MS angle 40 x 40 x 6mm frame and lower half portion with MS Sheet of 3.15, thcik and half of upper portion fixed the glass of 4mm thick including painting with fire red and plaster/cement work etc as required at site complete all as specified and dircted.
Supply and fixing, erection and installation of Fire Hose Cabinet to be mounted externally near the Hydrant Post fabricated from 16 SWG MS Steel of appox size 750 mm x 600 mm x 250 mm with a canopy , door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accomodate one hydrant valve, one branch nozzle and two 7.5 mtrs hose, weather proof, Finished with P.O. fire red color ( Sample to be approved prior to entire supply) including taking down old complete all as specified and directed.
Supply ,fixing,testing and commissioning of wall mounting swinging type First aid fire hose reel with drum,hanging bracket,30 mtr long and 20mm dia high pressure hose reel as per IS 444 with gun metal shut off nozzle having 5mm dia orifice.The hose reel shall be conforming to IS 884-1985. Drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or MS stand as per site requirement and the rate for fixing/hanging items in the rates quoted(for internal hydrant and one each an either side of stage) including taking down old etc complete all as specified and directed by Engr-in-charge.
Supply and fix fire hydrant landing valve type A (single head outlet) gun metal of 80 mm dia landing valve with 63 mm dia female outlet complete and 80 mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63 mm with couplings concorming to IS 903 including taking down old complete all as specified and directed.
S & F, testing and commissioning of 100mm dia, heavy duty class "C" MS pipe 6 mm thick, ISI marked as per IS : 1239 with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer includingtaking down old etc complete all as specified and directed.
S & F, testing and commissioning of 80mm dia, heavy duty class "C" MS pipe 6 mm thick ,ISI marked as per IS: 1239 with all necessary fittings & fabrication like tees , elbows ,flanges ,reducers ,gaskets ,nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer includingtaking down old etc complete all as specified and directed.
Supply and fix fire hydrant landing valve type A (single head outlet) gun metal of 80 mm dia landing valve with 63 mm dia female outlet complete and 80 mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63 mm with couplings concorming to IS 903 (for internal hydrant at 1.5 mtr height including taking down old complete all as specified and directed.
M&L for making connection from riser to to hose reel drum with GI pipe Medium grage of size 25mm dia including GI Socket, Elbow, Tee, Nipple, socket etc all materials required at site complete all as specified and directed.
M&L for replacement of gate/butterfly valve 25mm dia of cast copper alloy including taking down old complete all as specified and directed.
M & L for replacement of CI non return valve of size 100mm dia including flage and Nut, bolts, wahsher etc including taking down old complete all as specified and directed by Engr in charge.
M & L for replacement of CI sluice valve class PN 1.6 of size 100mm dia including flage and Nut, bolts, wahsher etc including taking down old complete all as specified and directed by Engr in charge.
M & L for replacement of Fire Brigade inlet connection 2 way if size 80mm dia including Nut, bolts, wahsher etc including taking down old complete all as specified and directed by Engr in charge.
M & L for wheather protective cover for 15 HP Centrifugal/Jockey Pump made out of MS sheet of 3.15mm thick of size 1.2M x 1.0M screwed over MS Angle of size 30mm x 30mm x 5mm having four legs grouted with nuts and bolts with suitable height for proper working space including painting of two coat of synthic enamelled paint over ove coat of red oxide etc complete all as specified and directed by Engr in Charge.
M & L for replacement of Fire alarm control panel complying with BS EN 54 two loop panel of capacity from 99 detectors & 99 modules for 8 zone to detect 07 floor Addressable manual call point and modulesetc including taking down old complete all as specified and directed by Engr in charge.
M&L for replacement of Power contactor, 3 pole, MNX 22 type (AC3 rating 22 Amp and AC1 rating 32 Amp as per Cat No CS94980 of make L & T including taking down old & unserviceable complete all as specified and directed.
M&L for replacement of Bimetal Over load Relay, 3 pole, MN-2 direct mounting on MNX-22 type of relay range 14-23 Amp as per Cat No SS94144OODO of make L & T including taking down old & unserviceable complete all as specified and directed.
M&L for Single Phase Preventer, VSP2 type, 415 volts, 50 Hz including taking down old & unserviceable complete all as specified and directed.
M&L for MCB TP, 63 Amps, 415 volts including taking down old & unserviceable complete all as specified and directed.
M&L for MCCB TP, 100 Amps, 415 volts, breaking capacity 25 KA including taking down old & unserviceable complete all as specified and directed.
M&L for Submain wiring in PVC conduit with 2 x 2.5 Sqmm and 1x1.5 sq. mm earth wire wire copper conductor multistranded, run through existing PVC conduit not less than 20mm dia complete all as specified and directed.
M&L for Submain wiring in In existing surface/recessed steel/PVC conduit with 2 x 2.5 Sqmm and 1 x 1.5 sqmm earth wire wire copper conductor multistranded, PVC conduit not less than 20mm dia complete all as specified and directed.
M&L for Fire alarm MS Hooter including taking down old & unserviceable complete all as specified and directed.
M & L for replacement of Pressure gauge 4"dial 0-14 kgs rating complete all as specified and directed.
M & L for replacement of Pressure switch Universal type (HPLP) complete all as specified and directed.
M & L for replacement of Addressable manual call point resettable type coplete all as specified and directed.
Chaudhary Constructions
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .