| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 LAccepted-AOC CJSF ROAD GALI NO 12 NEAR SHRI RAM GARDEN VIKAS NAGAR PANIPAT 132103 HARYANA | PANIPAT | PANIPAT | HARYANA | 132103 | ₹7.9 L Quoted ₹8.0 L | L1 | Accepted-AOC After Negotiation OK |
| 2 | L2₹8.3 L+₹36,197 (4.55%)Rejected-AOC | ₹8.3 L+₹36,197 (4.55%) | L2 | Rejected-AOC Due to L2 |
Tender Value
₹9.0 L
EMD Value
₹18,100
Closing Date
17 Feb 2026, 5:00 pmClosed
Ashwani Gour
Electrical Faridabad
Annual maintenance of air conditioner units installed in HSVP Office Building Sector-12 Faridabad for the year 2026-27 (Excluding the period 11/2026 to 02/2027).
2026_HBC_502114_1
2026CAF4B9C8 2215 4D3F 99E4 5644C7776464364HSV
Open Tender
Electrical Works
Works
365 days
Faridabad (MC)
Annual maintenance of air conditioner units installed in HSVP Office Building Sector-12 Faridabad for the year 2026-27 (Excluding the period 11/2026 to 02/2027).
2 documents required · 2 mandatory
₹500
₹18,100
Yes
24 Apr 2026
11 Feb 2026
18 Feb 2026
11 Feb 2026
17 Feb 2026
11 Feb 2026
Overall maintenance of 1.5 TR Split type air conditioners including periodical servicing of indoor and outdoor units, repair of indoor and outdoor units, refilling of refrigerant as required, providing thermal insulation on cooper pipes, replacement of drain pipe, repair of defective compressor, exhaust motors, I/D unit blower fans, including electrical wiring, connection plates, PCB, contactor, remote, TandP required, ladder, safety equipments required with complete material and labour to make the A.C system always in running condition complete in all respect up to the entire satisfaction of the Engineer in-charge of the work. (Rate without GST)
Overall maintenance of 1.5TR Window type air conditioners including periodical servicing of indoor and outdoor units, repair of indoor and outdoor units, refilling of refrigerant as required, providing thermal insulation on cooper pipes, replacement of drain pipe, repair of defective compressor, exhaust motors, I/D unit blower fans, including electrical wiring, connection plates, PCB, contactor, remote, TandP required, ladder, safety equipments required with complete material and labour to make the A.C system always in running condition complete in all respect up to the entire satisfaction of the Engineer in-charge of the work. (Rate without GST)
Overall maintenance of 2TR Split type air conditioners including periodical servicing of indoor and outdoor units, repair of indoor and outdoor units, refilling of refrigerant as required, providing thermal insulation on cooper pipes, replacement of drain pipe, repair of defective compressor, exhaust motors, I/D unit blower fans, including electrical wiring, connection plates, PCB, contactor, remote, TandP required, ladder, safety equipments required with complete material and labour to make the A.C system always in running condition complete in all respect up to the entire satisfaction of the Engineer in-charge of the work. (Rate without GST)
Overall maintenance of 2TR Window type air conditioners including periodical servicing of indoor and outdoor units, repair of indoor and outdoor units, refilling of refrigerant as required, providing thermal insulation on cooper pipes, replacement of drain pipe, repair of defective compressor, exhaust motors, I/D unit blower fans, including electrical wiring, connection plates, PCB, contactor, remote, TandP required, ladder, safety equipments required with complete material and labour to make the A.C system always in running condition complete in all respect up to the entire satisfaction of the Engineer in-charge of the work. (Rate without GST)
Supply and erection of 2.5 Sqmm 3-core copper flexible cable , FRLS PVC insulated and round sheathed, bright annealed copper conductor heavy duty industrial flexible cable for voltage grade 1100 volts confirming to IS: 694:2010 complete in all respect up to entire satisfaction of the Engineer-in-Charge of the work. (Rate without GST). Make – Havells/ polycab/ KEI or make approved by DHBVN.
Supply and erection of drain pipe 25mm nominal dia PVC type suitable for air conditioners complete in all respect up to the entire satisfaction of the Engineer in-charge of the work. (Rate without GST) Make:- Finolex/Superme/Prince
Supply, Erection, Testing and Commissioning of copper pipe (set of liquid line and suction line) suitable for 1.5/2TR ACs complete in all respect up to the entire satisfaction of the Engineer in-charge of the work. (Rate without GST)
Supply, Installation, Testing and Commissioning of 4 KVA stabilizer copper wound complete in all respect up to the entire satisfaction of the engineer in-charge of the work. Make:- Microtek /Logistic (Rate without GST)
[23.22.3.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 3.2. Supply and erection of sheet steel enclosures 1pole/2 pole/4 pole on wall/on existing pedestal complete as required. S.P.N. or DP enclosure suitable for DP MCB
[23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.09 MB
BOQ_580770.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .