Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC DUE TO BEING L1 AND REASONABLE | |
| 2 | L2₹15.8 L+₹18,610 (1.19%)Rejected-Finance | L2 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 3 | L3₹16.7 L+₹1.1 L (6.91%)Rejected-Finance | L3 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 4 | L4₹17.2 L+₹1.6 L (10.5%)Rejected-Finance C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L4 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE | |
| 5 | L5₹17.7 L+₹2.1 L (13.8%)Rejected-Finance | L5 | Rejected-Finance DUE TO NOT BEING L1 AND REASONABLE |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
10 Jan 2024, 6:00 pmClosed
GE SOUTH AKHNOOR
GE SOUTH AKHNOOR
REPAIR REPLACEMENT OF STREET LIGHT , CONTROL SWITCHES AND OTHER CONNECTED ITEMS IN OTM AND MD ACCN AT SOUTH BANK AND NORTH BANK OF AKHNOOR UNDER GE (SOUTH) AKHNOOR.
2023_MES_632516_1
GES/AKH-44/2023-24
Open Tender
Civil Works
Item Rate
180 days
AKHNOOR
MES EN-LISTED CONTRACTOR WITH CLASS E AND ABOVE WITH CATEGORY b(i)
9 documents required · 9 mandatory
₹500
GE SOUTH AKHNOOR
₹40,000
11 Mar 2024
13 Dec 2023
18 Jan 2024
13 Dec 2023
10 Jan 2024
27 Dec 2023
Amount
Disconnecting and taking down the existing perimeter/street light fittings of any type and any specifications or any accessories related to tperimeter/street light fittings of any descriptions, fitted/ fixed on poles, buildings or watching towers of any heights and any location, and re-fixing the same after necessary repairs/ replacement of defective parts including rectifying the same as per directions by concerned JE E/M and Engineer-In-Charge, at various locations, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of T&P, ladder or mechanical lift shall be deemed included in quoted rate. (ii) Supply of spare parts of timer switch shall be measured and paid separately under relevant items of Schedule ‘A’/ BOQ. (iii) Cost of connecting up with twin core twisted flexible copper conductor cable with suitable size shall also deem to be included in the quote rates.
Supply only electronic driver , as per existing sample suitable for street light fitting 30 Watt
Supply only electronic driver , as per existing sample suitable for street light fitting 45/50 Watt
Supply only electronic driver , as per existing sample suitable for street light fitting 60 Watt
Supply only PVC insulated and PVC sheathed copper flexible cable stranded of 1.5 sqmm twin core flat or circular with connection from light fittings to OH conductor or upto junction box all as directed
S&F in replacement of SITC of high-quality integrated LED Street Light with a minimum system lumen of 4950 Lm and system wattage not exceeding 45W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection, complete all as specified, complete all as specified. Make: Crompton Model No RAPTOR PRO-I, cat part No- CRP-409-45-57-SL-LM-NSR or Equivalent makes in Philips/Wipro/GE LIGHTING /C&S. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
S&F in replacement of SITC of high-quality integrated LED Street Light with a minimum system lumen of 6600 Lm and system wattage not exceeding 60W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF > 0.95. Lifetime of 50K hours @L70.The Ingress protection should be minimum IP 66 with an IK rating of 07. The Luminaire should have 4KV internal 10KV external surge protection in the Luminaire.Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters and including suitable size and length of flexible copper wire and making the connection , complete all as specified, complete all as specified. Make: Crompton Model No RAPTOR PRO-I, cat part No- CRP-409-60-57-SL-GL-NSG or Equivalent makes in Philips/Wipro/GE LIGHTING /C&S. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
Supply and fixing in replacement of 1 x 30 Watt LED Flood Floodlight luminaire with polycarbonate optics, pressure die-cast housing along with IP66 ingress protection , CCT 5700K 4kV inbuilt surge protection. E cacy 110 lm/W all as directed Make : Bajaj cat part No GLEAM F 33L WH SY PC SD V2 or Equivalent makes in Crompton/ Havells. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
S&F in replacement of LED Post Top with a system lumen output of 2800 lumens and a minimum system efficacy of 80 lm/W. . The luminaire should have a color temperature of 3000K to 5700K and CRI > 70. The luminaire shall meet IP65 & IK07 protection with THD < 10% and PF > 0.95. The luminaire shall have Cast aluminium spigot housing with Opal acrylic diffuser. The total power consumption should not exceed 40W (including driver) and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make: Crompton Model No Maple, cat part No- LPTO-40-CDL-M or Equivalent makes in Philips/Wipro/GE LIGHTING /C&S. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
Supply and fixing in replacement of LED Bollard light fittings 10W IP65 protection with robust design and efficient light distribution complete including PCC foundation 30x30x30 cm all as directed .Make : Crompton cat No LBLTW-10-CDL/WW or equivalent makes in Philips/Wipro/GE LIGHTING /C&S.
S&F in replacement of LED Post Top with a system lumen output of 1625 lumens and a minimum system efficacy of 70 lm/W. The luminaire should have a color temperature of 3000K to 5700K and CRI > 70. The luminaire shall meet IP65 & IK07 protection with THD < 10% and PF > 0.95. The luminaire shall have Cast aluminium spigot housing with Opal acrylic diffuser. The total power consumption should not exceed 20W (including driver) and including suitable size and length of flexible copper wire and making the connection, complete all as specified and as directed by Engineer-In-Charge. Make: Crompton Model No HERITAGE, cat part No- LPTH-20-WW or Equivalent makes in Philips/Wipro/GE LIGHTING /C&S. Warranty certficate for 2 years to be provided by Employee of Organization of Terittory.
Disconnecting and taking down the existing street light timer from poles of any type and any specifications , fitted/ fixed on poles, and re-fixing the same after necessary repairs/ replacement of defective parts including rectifying the same as per directions by concerned JE E/M and Engineer-In-Charge, at various locations, complete all as specified and directed by Engineer-In-Charge. Note: (i) Cost of T&P, ladder or mechanical lift shall be deemed included in quoted rate. (ii) Supply of spare parts of timer switch shall be measured and paid separately under relevant items of Schedule ‘A’/ BOQ. (iii) Cost of connecting up with twin core twisted flexible copper conductor cable with suitable size shall also deem to be included in the quote rates.
Supply only Nature time switch, 230 V automatically switching ON/OFF as per seasonal changes single phase upto 5 KW capacity Make : Kakatiya/ Indoasian/Legrand
Supply only Timer switch 3 phase with 48 hours back-up charge programmable and operated within 5 minutes of preset time of current rating 32 amps Make Schneider/Legrand/BCH
Supply only Power contractor TP 415 volts, 32 amps without aux relay suitable for operating of timer switch Make : L&T / C&S/ BCH
MCB, single pole, 6 to 32 Amps, 240 Volts, 50 Hz, including necessary incoming and out going electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
MCB, Single Pole and Neutral, 40-63 Amps, 240 volts, 50 Hz, 'C' curve including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing in repalcement light bracket made out of GI pipe 1.5 Mtr long, 40 mm dia medium grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for PCC poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer all as specified and as directed.
Replacement of old cracked/ damaged, concrete poles with new pre-stressed concrete pole, 9.0 metres long, cross section 102mmx172mm at top and 102mmx279mm at bottom, class 10, including painting strips in black and white colour, 300mm thick, upto 1.50mtr height, from top of PCC coping with synthetic enamel paint after preparing the surface, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16.0 Sqmm, 4.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 50.0 Sqmm, 3.5-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10.0 Sqmm, 2.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed by Engineer-In-Charge.
Replacment of switch fuse iron clad of sheet metal SP fused and neutral link of capacity 32 Amps 240 volts, complete all as specified and directed by Engineer-In-Charge. Make: Schneider/ ABB/ Legrand.
Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable,erection of poles, stays, pipes etc and not exceeding 10sqm on plan and getting out all as directed.
Excavation in trenches, not exceeding 1.50 mtr wide and exceeding 1.50mtr but not exceeding 3.0mtrs in depth, not exceeding 10 Sqm on plan and getting out, in any type of soil, for laying electric cables or foundation of poles/ stays etc, complete all as specified and as directed by Engineer-In-Charge.
Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified.
Removal of excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above in starting point.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engineer-In-Charge. Note: Punned thickness shall be measured.
Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed by Engineer-In-Charge.
Material and labour for Plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregates ) as in foundation filling of pole etc complete all specified and directed.
M&L for providing cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete all as specified and directed by Engr in charge.
Material and labour GI tubing 40 mm dia, light grade galvanized for cable protection and fixing of post top lantern with all connecting items (like suitable size of clamps, angle, nut & bolts) for holding of pipe with pole duly painted complete all as specified and directed. Make : Tata /Jindal / Swastik.
Replacement of SMC junction box of size 250MMx200MMx100MM mounted on GI pipe with MS clamp made out of 40 mm x 6 mm flat for fixing box on pole/wall including terminal point mounted on epoxy insulator for cable connection with 01 No MCB SP 10 amps complete all as directed. Make : Sintex Model No GSJB-2520 or Equivalent makes in L&T/ Legrand/ ABB/ Siemens
Material & labour for earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3mm thick buried directly in ground less than 3.0m deep below normal ground level as earth electrode with top edge of the earth plate not less than 2.25mtr below ground level using GI strip 32x6 mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe of GI tubing light grade 40mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and kalmi shore all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. NOTE :- (i) Item of earthing includes cost of 7.5 m long GI strip of size 32x6mm with protection pipe of 40mm dia GI medium grade, any variation in length shall be adjusted through deviation order based on SSR rates enhanced by (-20)%. (ii) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost.
Amount of Schedule of credit of for Rs 77,510.00 shall be deducted from quoted amount.
RAJINDER ELECTRICAL WORKS
CHOPRA CONSTRUCTIONS
Usha Engineering Co.
M/S DC CONSTRUCTIONS
SHSS ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .