Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC | ₹43.5 L Quoted ₹44.1 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹44.4 L+₹29,904.65 (0.68%)Rejected-Finance | ₹44.4 L+₹29,904.65 (0.68%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹45.1 L+₹99,052.85 (2.25%)Rejected-Finance | ₹45.1 L+₹99,052.85 (2.25%) | L3 | Rejected-Finance Being L3 |
| Sl No | Description | Qty | Unit | M/S Sunshine Construction L1 | Goyal Construction L2 | M/S DADISA CONSTRUCTION L3 |
|---|---|---|---|---|---|---|
| 1.00 | S&F in repairs 1000 Ltrs capacity double layer (ISI marked) rotational moulded polyethylene triple layeredwater storage tanks, (cylindrical vertical with closed top) hoisted and fixed in position including dismantling, all as specified in SSR part I complete all as specified and directed. | 6 | Each | 7,000 ₹42,000 Lowest | 7,500 ₹45,000 | 7,200 ₹43,200 |
| 2.00 | S&F in repairs ball valve/float ball high pressure of PTMT 25mm with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed minimume weight 210 gm etc complete all as specified and directed. | 6 | Each | 200 ₹1,200 Lowest | 550 ₹3,300 | 300 ₹1,800 |
| 3.00 | Taking up or down existing 15 mm bore steel tubing and connection complete all as specified and directed. | 46 | RM | 30 ₹1,380 | 13 ₹598 Lowest | 20 ₹920 |
| 4.00 | Taking up or down existing 20 mm bore steel tubing and connection complete all as specified and directed. | 285 | RM | 40 ₹11,400 | 15 ₹4,275 Lowest | 30 ₹8,550 |
| 5.00 | Taking up or down existing 25 mm bore steel tubing and connection complete all as specified and directed. | 80 | RM | 60 ₹4,800 | 20 ₹1,600 Lowest | 40 ₹3,200 |
| 6.00 | Supplying, fixing, jointing and testing galvanised steel water tubing 25mm bore medium grade with all fittings such as bend, elbow, socket reducer etc fixed to walls and ceilings or laid in floors complete all as specified and directed. | 20 | RM | 350 ₹7,000 | 320 ₹6,400 Lowest | 330 ₹6,600 |
| 7.00 | S&F CPVC 15 mm outer dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and directed. | 46 | RM | 180 ₹8,280 Lowest | 270 ₹12,420 | 200 ₹9,200 |
| 8.00 | S&F CPVC 20 mm outer dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and directed. | 285 | RM | 220 ₹62,700 Lowest | 340 ₹96,900 | 220 ₹62,700 Lowest |
| 9.00 | S&F CPVC 25 mm outer dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and directed. | 60 | RM | 250 ₹15,000 | 380 ₹22,800 | 240 ₹14,400 Lowest |
| 10.00 | S&F CPVC brass elbow (3/4" X ½") for 20 mm outer dia CPVC pipe complete all as specified and directed. | 18 | Each | 200 ₹3,600 | 120 ₹2,160 | 100 ₹1,800 Lowest |
Tender Value
₹44.9 L
EMD Value
₹90,000
Closing Date
1 Aug 2026, 6:00 pmClosed
GE (MIS) Mhow
Garrison Engineer (Maint) Infantry School Mhow (MP) - 453441
SPL REPAIR TO ALL BATHROOMS IN MMG AGL KLP BLDG NO CB 271 OF SW DIV PROVN OF VIEW CUTTER ON BDY WALL OFFRS MESS AREA PROVN OF IRON LADDER FOR CB 354 CB 355 AT 5 JAK RIF PROVN OF 02 X SEPTIC TANK ALONGWITH 02 X SOAKAGE WELL NEAR BLDG NO SM 338 SM 339
2026_MES_774840_1
8962/GE (MIS)/Mhow
Open Tender
Civil Works - Others
Item Rate
150 days
GE (MIS) Mhow
All as per Tender document
8 documents required · 8 mandatory
₹500
GE (MIS) Mhow
₹90,000
Yes
3 Sept 2026
25 Jun 2026
3 Aug 2026
25 Jun 2026
1 Aug 2026
13 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F 1000 Ltrs capacity double layer (ISI marked) rotational moulded polyethylene triple layeredwater storage tanks, (cylindrical vertical with closed top) hoisted and fixed in position including dismantling, all as specified in SSR part I complete. | 6 | Each | - | - |
| 2 | S&F in repair ball valve/float ball high pressure of PTMT 25mm with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed minimume weight 210 gm etc all as specified and directed. | 6 | Each | - | - |
| 3 | Taking up or down existing steel tubing and connection complete for following sizes:-
(a) 15 mm dia | 30 | RM | - | - |
| 3.01 | (b) 20 mm dia | 240 | RM | - | - |
| 3.02 | (c )25 mm dia | 80 | RM | - | - |
| 4 | Supplying, fixing, jointing and testing galvanised steel water tubing medium grade with all fittings such as bend, elbow, socket reducer etc fixed to walls and ceilings or laid in floors, complete for the following sizes: -
(a) 25 mm dia | 20 | RM | - | - |
| 5 | S & F of CPVC 16 mm outer dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and directed. | 30 | RM | - | - |
| 6 | S & F of CPVC 20 mm outer dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and directed. | 240 | RM | - | - |
| 7 | S & F of CPVC 25 mm outer dia pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and directed. | 60 | RM | - | - |
| 8 | S & F of CPVC brass elbow (3/4" X ½") for 20 mm outer dia CPVC pipe complete all as specified and directed. | 18 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.22 MB
DetailsOfWorkInAndInHand.pdf
Additional Documents • 0.10 MB
ParticlularSpecifications8962.pdf
Tender Documents • 0.52 MB
ListOfMakeMake8962.pdf
Tender Documents • 0.51 MB
BOQ_867637.xls
BOQ • 0.48 MB
Tenderandspecialcondition8962.pdf
Tender Documents • 0.52 MB
datecorrigendum8962.pdf
PDF • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .