| Sl No | Description | Qty | Unit | HYDRAULIC ENGINEERING COMPANY L1 | SB Trading company L2 | HILL CONSTRUCTION AND ENGINEERING CO. SOLAN L3 |
|---|---|---|---|---|---|---|
| 1.00 | Providing ,Fixing ,testing and commissioning the horizontal spindle multistage centrifugal Ring section Non -API pump Model HGB 4/10 206 Cum/Hour with LIFT OFF DEVICE with section and discharge load as per KSB India Standred with Gland packing KSB STD quality plan will be Followedd. 1(i)Pressure gauge 1 each at section and discharge.(ii) Counter flange for section and discharge.(iii)Motor shims and foundation bolts, pump is ring oil lubricated with balacing disc type balacing device.(2).Conical suction strainer of size :-DN 250class 159 RF with suction adapter of size 250xDN 150 class 150. (3)Connecting gear coupling between pump and Motor Make :-Rathi transpower india. (4)Non-witness performance testing as per KSB india standred with KSB India test bed motor and cold water at ambient temperture for all pump.NPSHR 3 % test for one pump.(5)set for special tools common for these offered water pumps.(6)Commissioning spare per pump 1set of pump O ring and Gaskets-1 set. Packing and painting as per KSB India Standred. Specufication Of Motor:- Providing ,Fixing ,testing and commissioning BHEL/ABB make motor of 1250 KW,2960RPM with sleeve bearings ( forced oil lubricated bearings)foot mounted Horizontal squirrel cage induction Motor.Enclosure;-SPDP, Type of cooling :-IC01,Insulation/Temp Rise;-F class B, Ambient Temperture :-40 Deg C,Method of starting;-DOL. ,Type of bearing ;-sleeve,Type of Fan;-Uni-directional, Noise of vibration ;- as per IS/IEC,Space heater,winding RTD as per Mf.r std. ,Non- witness routing test shall be conducted on all Motros.Type tesr report for similar motor shall be submitted. ;- Standard relay panel as per Mfr Std. ( Make:-Southern lubrications /Eq. with all leads & lifts Complete in all respects. | 1 | Set | 1,33,00,000 ₹1,33,00,000 Lowest | 1,34,00,000 ₹1,34,00,000 | 1,35,50,000 ₹1,35,50,000 |
| 2.00Total Head :- 1480 mtrs. | ||||||
| 3.00Capacity/ Discharge :- 206 Cum/Hour | ||||||
| 4.00Dia of R/Main:- 175 mm. | ||||||
| 5.00SITE CONDITIONS:- | ||||||
| 6.00Location of Site:- | ||||||
| 7.00The altitude of place in which the motor is intended to work in ordinary service (in metres) :- To be filled by the Engineer Incharge. | ||||||
| 8.00Humidity:- Weather generally remains humid during monsoon season. | ||||||
| 9.00Nature of atmosphere:- | ||||||
| 10.00Detail of quality of water:- Clear cold water | ||||||
Tender Value
₹1.3 Cr
EMD Value
₹1.3 L
Closing Date
20 Jan 2023, 11:00 amClosed
AGM WSD SJPNL
AGM WSD SJPNL US CLB SHIMLA 171001
LWSS Shimla from Gumma SH Providing fixing testing of 1 No pump and motor complete set of KSB make Model HGB 4 10 along with induction motor 1250 KW 1675 HP at Bed No 1 old Gumma Pumping station under AMRUT Project
2023_MC_67056_1
41 dated 05/01/2023
Open Tender
Pumps/Motors
Item Rate
240 days
Shimla
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,000
GM MC
₹1.3 L
16 Feb 2023
5 Jan 2023
20 Jan 2023
5 Jan 2023
20 Jan 2023
5 Jan 2023
5 Jan 2023 - 20 Jan 2023
Amount
Providing ,Fixing ,testing and commissioning the horizontal spindle multistage centrifugal Ring section Non -API pump Model HGB 4/10 206 Cum/Hour with LIFT OFF DEVICE with section and discharge load as per KSB India Standred with Gland packing KSB STD quality plan will be Followedd. 1(i)Pressure gauge 1 each at section and discharge.(ii) Counter flange for section and discharge.(iii)Motor shims and foundation bolts, pump is ring oil lubricated with balacing disc type balacing device.(2).Conical suction strainer of size :-DN 250class 159 RF with suction adapter of size 250xDN 150 class 150. (3)Connecting gear coupling between pump and Motor Make :-Rathi transpower india. (4)Non-witness performance testing as per KSB india standred with KSB India test bed motor and cold water at ambient temperture for all pump.NPSHR 3 % test for one pump.(5)set for special tools common for these offered water pumps.(6)Commissioning spare per pump 1set of pump O ring and Gaskets-1 set. Packing and painting as per KSB India Standred. Specufication Of Motor:- Providing ,Fixing ,testing and commissioning BHEL/ABB make motor of 1250 KW,2960RPM with sleeve bearings ( forced oil lubricated bearings)foot mounted Horizontal squirrel cage induction Motor.Enclosure;-SPDP, Type of cooling :-IC01,Insulation/Temp Rise;-F class B, Ambient Temperture :-40 Deg C,Method of starting;-DOL. ,Type of bearing ;-sleeve,Type of Fan;-Uni-directional, Noise of vibration ;- as per IS/IEC,Space heater,winding RTD as per Mf.r std. ,Non- witness routing test shall be conducted on all Motros.Type tesr report for similar motor shall be submitted. ;- Standard relay panel as per Mfr Std. ( Make:-Southern lubrications /Eq. with all leads & lifts Complete in all respects.
Total Head :- 1480 mtrs.
Capacity/ Discharge :- 206 Cum/Hour
Dia of R/Main:- 175 mm.
SITE CONDITIONS:-
Location of Site:-
The altitude of place in which the motor is intended to work in ordinary service (in metres) :- To be filled by the Engineer Incharge.
Humidity:- Weather generally remains humid during monsoon season.
Nature of atmosphere:-
Detail of quality of water:- Clear cold water
Water free from sand or not :- Yes
Water corosive or not :- Not
Turbidity (if any):- 1.5 NTU.
NPSH available:- Positive suction.
Any other information or requirement:-
OPERATING CONDITIONS:-
Type of current:- AC three/single phase
Operating frequency:- 50 HZ
Rated voltage:- 400 (+/-) 10% volts
System of earthing if any to to be adopted.:- Double loop earthing as per BIS 3043-1987 latest with upto date ammendments
No. of working hours per day:- 16 hours
Speed of revolution in RPM:- To be quoted by tenderer
Direction of rotation:- To be quoted by tenderer
The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.:- 35 Degree Centigrade
MOTOR:-
Ref. to BIS code:- BIS 325-1978 read with BIS 900-1992 (latest)with upto date ammendments
Type of enclosure of motor:- SPDP(as per BIS 4691-1985 (latest)
Type of duty:- Continuous as per IS-12824-1989 or latest with up to date ammendments
Mechanical out put in KW:- 1250 Kw (2960 RPM) Suitable for driving centrifugal pumps required for duties specified against pumps.To avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover.
Class of insulation:- Class ~F~
Max.permissible temp.rise of motor reqd. if different from given in B(viii) above:- 16.5O
Particulars of test reqd. & where they are to be conducted:- As per terms & conditions
Motor :-Induction motor with F class insulation.
Details of shaft extension reqd.:- Just sufficient to provide direct drive by flexible coupling to pump.
Type of slip-ring gear whether continouly rated or for starting purposes only & whether to be fitted with brush lifting or short circuit arrangements or both if interlocks are rquired.:- Continously rated for Squirrel cage/ Slipring motor
Breakway torque in terms of rated load torque & the corresponding breakway starting current which may be taken from the supply with the starting apparatus in circuit.:- Breakway torque to be given by the tenderer but the starting current should not exceed 2.5 times of the full load current.
Nature of load & any information regarding the driven machine which has a bearing upon the torque reqd. during the accelerated period, the kinetic energy of the moving parts to be accelrated & No.of starts during a specified period.:- Sufficient to work the pump offered
Where possible fault capacity of the system to which the motor is connected.:- The motor should be able to withstand initial current of 2.5 times the rated current for two minutes without suffering damages or permanent deformations.
PUMP :-BIS 1520-1980 read with BIS 9137-1978 both with up to date ammendments
Nos of pumps reqd.:- 1 Nos pump.
Spare parts required:- For 10 years normal maintenance as recommended by manufacturer.
Optional fittings reqd.:- Air cock for exahausting air from each stage.
PUMP OPERATING CONDITIONS:-
Capacity (in LPS) 206 Cum/Hours
Total head (in Mts).:- 1480 Mtrs
If total head is not known then
following details be provided:-
i) Static head ( in mtrs) =1480
ii) Minimum depth of water( in mtrs)
iii) Variation in water level ( in mtrs)
iv) Ground level to max. water level ( in mtrs)
v) Ground level to delivery point ( in mtrs)
vi) Pressure in the suction tank (in Kg/cm^2 )
vii) Pressure in the delivery tank (in Kg/cm^2 )
Length of R/Main (in metres):- 3250 mtrs
Dia of R/Main (in mm):- 175mm.
Drive arrangement:- Direct through flexible coupling on a common base plate
Drive type:- Electric driven
NPSH reqd.:- To be quoted by the tenderer
Limits of total head in which
the pump is reqd. to operate.:- (-) 15% to (+) 10% of total head.
Suction/delivery size of pump:- To be specified by the tenderer
Efficiency of pump at:- To be specified by the tenderer
a) duty head
b) (+)10 % head
Material of construction:- To be specified by the tenderer (manufacturer,s certficate to be appended)
SB Trading company
HILL CONSTRUCTION AND ENGINEERING CO. SOLAN
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.49 MB
From6.pdf
Tender Documents • 0.30 MB
From8.pdf
Tender Documents • 1.80 MB
NIT.pdf
Tender Documents • 0.24 MB
BOQ_101084.xls
BOQ • 0.29 MB
Tc.pdf
Tender Documents • 0.17 MB
Undertaking.pdf
Tender Documents • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].