Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹8.1 CrAccepted-AOC | ₹8.1 Cr Quoted ₹8.4 Cr | 1 | Accepted-AOC Work Order |
| 2 | 2₹9.1 Cr+₹68.4 L (8.10%)Rejected-Finance 193 4 B APPA APARTMENT OLD PETH TALEGAON DABHADE TAL MAVAL DIST PUNE | PUNE | MAHARASHTRA | 412106 | ₹9.1 Cr+₹68.4 L (8.10%) | 2 | Rejected-Finance Reject |
Tender Value
₹7.7 Cr
EMD Value
₹3.8 L
Closing Date
27 Mar 2023, 5:00 pmClosed
superintending Engineer, PMGSY, Pune Region, Pune
Block No.306, 3rd Floor, New Administrative Building, Opp. Council Hall, Pune
Upgradation of 1 TR 02 to Shivandeshwar Road 2 TR 11 to Kille Morgiri Road 3 TR 01 to Shinganwadi Road 4 TR 16 to Aaral (Diwashi KH.) Road 5 LR 174 to Vittalwadi Road 6 TR 17 to to Kalambe Road Tal. Patan Dist Satara DPC SAT II 05
2023_MMGSY_881036_4
E-Tender NO.25/2022-23 DPC
Open Tender
Civil Works
Percentage
365 days
Satara
As Per NIT
8 documents required · 8 mandatory
₹15,000
Yes
₹3.8 L
Yes
superintending Engineer, PMGSY, Pune Region, Pune
13 Oct 2023
6 Mar 2023
29 Mar 2023
6 Mar 2023
27 Mar 2023
6 Mar 2023
14 Mar 2023
Amount
1) Proposed Upgradation/ Improvement and Maintenance of road from TR -02 to Shivandeshwar from ch 0/000 to ch 2/975 Tal- Patan, Dist-Satara., Clearing and Grubbing Road Land-By mechenical means-In area of non-thorny jungle- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including all lifts, leads and including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201, As per directed by Engineer Incharge.
Clearing and Grubbing Road Land-By Mechanical Means -In area of thorny jungle- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including all lifts, leads and including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201, As per directed by Engineer Incharge.
Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with all lifts and leads as per Technical Specification Clause 301.4, As per directed by Engineer Incharge.
Dismantling Stone Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material including all lifts and leads as per Technical Specification Clause 202, As per directed by Engineer Incharge. Rubble Stone Masonry in Cement Mortar
Above 600 mm to 900 mm dia Hume pipe-Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202, As per directed by Engineer Incharge.
Construction of Embankment with Material Obtained from Roadway Cutting- Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5, As per directed by Engineer Incharge.
Construction of Embankment with Material Obtained from borrow pits- Construction of embankment with approved material obtained from borrow pits with all lifts, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5, As per directed by Engineer Incharge.
Excavation in Soil using Hydraulic Excavator and Tippers with disposal - Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location including all lifts and leads as per Technical Specification Clause 302.3, As per directed by Engineer Incharge.
Removal of Unsuitable Soil and Disposal - Removal of unsuitable soil including excavation, loading and disposal including all lifts lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11, As per directed by Engineer Incharge.
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal - Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site including all lifts and leads, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5, As per directed by Engineer Incharge.
Excavation in Hard Rock (blasting prohibited) (Mechanical Means)-Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal including all lifts and leads, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5, As per directed by Engineer Incharge.
Construction of Subgrade and Earthen Shoulders-Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 including all lifts and leads as per Technical Specification Clause 303.1., As per directed by Engineer Incharge.
Granular Sub-base with Well Graded Material (Table 400.1) - By Mix in Place Method - For Grading II Material- Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401., As per directed by Engineer Incharge.
Water bound macadam with crushable screening (B) by mechenical means WBM grading 2-Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405., As per directed by Engineer Incharge.
Water Bound Macadam Sub-base/base ( using stone screening) (B) By Mechanical means Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.- WBM Grading 2, As per directed by Engineer Incharge.
Tack Coat ii)on the prepared dry and hungry bituminous surface Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503., As per directed by Engineer Incharge.
Modified Penetration Macadam- Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506. A) 50 mm thick Bitumen (S-65) 60/70- VG-30, As per directed by Engineer Incharge.
Tack Coat i) Prepared bituminous surface- Above MPM-Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503., As per directed by Engineer Incharge.
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade) Binder By Mechanical Means- Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (excluding seal coat)- Bitumen ( S- 65) 60/70- VG-30 @ 1.460 kg per sqm , As per directed by Engineer Incharge.
Seal Coat- Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A as per Technical Specification Clause 510, As per directed by Engineer Incharge.
cement concrete wearing course M 30 grade Including reinforcement- Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 600 MM Equilateral Triangle, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 600 MM circular, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 800 x 600 MM rectangular, As per directed by Engineer Incharge.
Direction and Place Identification signs upto 0.9 sqm size board - Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTM D4956-09 specifications , fixed over 4mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with are as not exceeding 0.9sqm .Supported in mild steel angle iron post 75x75x6mm-3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT&H specification No.801)(for are a Less than 0.9 sqm). 7 Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting., As per directed by Engineer Incharge.
Reinforced cement concrete M15 grade Kilometer stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703, As per directed by Engineer Incharge. ii) Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade 200 M. stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703, As per directed by Engineer Incharge. iii) 200 m stone (precast)
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704, As per directed by Engineer Incharge.- Boundary Pillar
Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete., As per directed by Engineer Incharge.
Providing and Fixing 'Logo' of PMGSY Project- Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1, As per directed by Engineer Incharge.
Sign Board of MMGSY / PMGSY Project Information-: Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor, As per directed by Engineer Incharge.
Citizen/Maintenance Information Board-MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDAP 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4, As per directed by Engineer Incharge.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures i) Ordinary Soil
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures i) Ordinary Rock ( not requiring blasting )
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures Hard rock ,IV. (blasting prohibited)
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, As per directed by Engineer Incharge.- P.C.C grade M 10
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204, As per directed by Engineer Incharge. P.C.C grade M 15
Providing and Laying Reinforced Cement Concrete Pipe NP3 of 1000 mm dia as per Design in Three/Two/Single Row- Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Providing and Laying Reinforced Cement Concrete Pipe NP2 of 600 mm dia as per Design in Single Row- Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Providing and Laying Reinforced Cement Concrete Pipe NP3 of 600mm dia as per Design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
R.C.C.pipe Np class of 300mm dia. 2m long- Providing and laying concrete pipes of I.S.NP.class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete., As per directed by Engineer Incharge.
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)", As per directed by Engineer Incharge.
PVC pipe 100mm dia along length-I) Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7, As per directed by Engineer Incharge.
2) Proposed Upgradation/ Improvement and Maintenance of road from TR - 11 to Kille Morgiri from ch 0/000 to ch 1/800 Tal- Patan, Dist-Satara. Clearing and Grubbing Road Land-By mechenical means-In area of non-thorny jungle- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including all lifts, leads and including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201, As per directed by Engineer Incharge.
Clearing and Grubbing Road Land-By Mechanical Means -In area of thorny jungle- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including all lifts, leads and including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201, As per directed by Engineer Incharge.
Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with all lifts and leads as per Technical Specification Clause 301.4, As per directed by Engineer Incharge.
Dismantling Stone Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material including all lifts and leads as per Technical Specification Clause 202, As per directed by Engineer Incharge. Rubble Stone Masonry in Cement Mortar
Above 600 mm to 900 mm dia Hume pipe-Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202, As per directed by Engineer Incharge.
Construction of Embankment with Material Obtained from Roadway Cutting- Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5, As per directed by Engineer Incharge.
Construction of Embankment with Material Obtained from borrow pits- Construction of embankment with approved material obtained from borrow pits with all lifts, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5, As per directed by Engineer Incharge.
Excavation in Soil using Hydraulic Excavator and Tippers with disposal - Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location including all lifts and leads as per Technical Specification Clause 302.3, As per directed by Engineer Incharge.
Removal of Unsuitable Soil and Disposal - Removal of unsuitable soil including excavation, loading and disposal including all lifts lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11, As per directed by Engineer Incharge.
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal - Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site including all lifts and leads, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5, As per directed by Engineer Incharge.
Excavation in Hard Rock (blasting prohibited) (Mechanical Means)-Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal including all lifts and leads, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5, As per directed by Engineer Incharge.
Construction of Subgrade and Earthen Shoulders-Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 including all lifts and leads as per Technical Specification Clause 303.1., As per directed by Engineer Incharge.
Granular Sub-base with Well Graded Material (Table 400.1) - By Mix in Place Method - For Grading II Material- Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401., As per directed by Engineer Incharge.
Water bound macadam with crushable screening (B) by mechenical means WBM grading 2-Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405., As per directed by Engineer Incharge.
Water Bound Macadam Sub-base/base ( using stone screening) (B) By Mechanical means Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.- WBM Grading 2, As per directed by Engineer Incharge.
Tack Coat ii)on the prepared dry and hungry bituminous surface Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503., As per directed by Engineer Incharge.
Modified Penetration Macadam- Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506. A) 50 mm thick Bitumen (S-65) 60/70- VG-30, As per directed by Engineer Incharge.
Tack Coat i) Prepared bituminous surface- Above MPM-Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503., As per directed by Engineer Incharge.
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade) Binder By Mechanical Means- Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (excluding seal coat)- Bitumen ( S- 65) 60/70- VG-30 @ 1.460 kg per sqm , As per directed by Engineer Incharge.
Seal Coat- Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A as per Technical Specification Clause 510, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 600 MM Equilateral Triangle, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 600 MM circular, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 800 x 600 MM rectangular, As per directed by Engineer Incharge.
Direction and Place Identification signs upto 0.9 sqm size board - Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTM D4956-09 specifications , fixed over 4mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with are as not exceeding 0.9sqm .Supported in mild steel angle iron post 75x75x6mm-3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT&H specification No.801)(for are a Less than 0.9 sqm). 7 Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting., As per directed by Engineer Incharge.
Reinforced cement concrete M15 grade Kilometer stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703, As per directed by Engineer Incharge. ii) Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade 200 M. stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703, As per directed by Engineer Incharge. iii) 200 m stone (precast)
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704, As per directed by Engineer Incharge.- Boundary Pillar
Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete., As per directed by Engineer Incharge.
Providing and Fixing 'Logo' of PMGSY Project- Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1, As per directed by Engineer Incharge.
Sign Board of MMGSY / PMGSY Project Information-: Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor, As per directed by Engineer Incharge.
Citizen/Maintenance Information Board-MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDAP 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4, As per directed by Engineer Incharge.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures i) Ordinary Soil
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures i) Ordinary Rock ( not requiring blasting )
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures Hard rock ,IV. (blasting prohibited)
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, As per directed by Engineer Incharge.- P.C.C grade M 10
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204, As per directed by Engineer Incharge. P.C.C grade M 15
Providing and Laying Reinforced Cement Concrete Pipe NP3 of 1000 mm dia as per Design in Three/Two/Single Row- Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Providing and Laying Reinforced Cement Concrete Pipe NP2 of 600 mm dia as per Design in Single Row- Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Providing and Laying Reinforced Cement Concrete Pipe NP3 of 600mm dia as per Design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
R.C.C.pipe Np class of 300mm dia. 2m long- Providing and laying concrete pipes of I.S.NP.class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete., As per directed by Engineer Incharge.
3) Proposed Upgradation/ Improvement and Maintenance of road from TR-01 to Shinganwadi from ch 0/000 to ch 1/560 Tal- Patan, Dist-Satara. Clearing and Grubbing Road Land-By mechenical means-In area of non-thorny jungle- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including all lifts, leads and including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201, As per directed by Engineer Incharge.
Clearing and Grubbing Road Land-By Mechanical Means -In area of thorny jungle- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including all lifts, leads and including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201, As per directed by Engineer Incharge.
Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with all lifts and leads as per Technical Specification Clause 301.4, As per directed by Engineer Incharge.
Dismantling Stone Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material including all lifts and leads as per Technical Specification Clause 202, As per directed by Engineer Incharge. Rubble Stone Masonry in Cement Mortar
Above 600 mm to 900 mm dia Hume pipe-Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202, As per directed by Engineer Incharge.
Construction of Embankment with Material Obtained from Roadway Cutting- Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5, As per directed by Engineer Incharge.
Construction of Embankment with Material Obtained from borrow pits- Construction of embankment with approved material obtained from borrow pits with all lifts, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5, As per directed by Engineer Incharge.
Excavation in Soil using Hydraulic Excavator and Tippers with disposal - Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location including all lifts and leads as per Technical Specification Clause 302.3, As per directed by Engineer Incharge.
Removal of Unsuitable Soil and Disposal - Removal of unsuitable soil including excavation, loading and disposal including all lifts lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11, As per directed by Engineer Incharge.
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal - Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site including all lifts and leads, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5, As per directed by Engineer Incharge.
Excavation in Hard Rock (blasting prohibited) (Mechanical Means)-Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal including all lifts and leads, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5, As per directed by Engineer Incharge.
Construction of Subgrade and Earthen Shoulders-Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 including all lifts and leads as per Technical Specification Clause 303.1., As per directed by Engineer Incharge.
Granular Sub-base with Well Graded Material (Table 400.1) - By Mix in Place Method - For Grading II Material- Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401., As per directed by Engineer Incharge.
Water bound macadam with crushable screening (B) by mechenical means WBM grading 2-Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405., As per directed by Engineer Incharge.
Water Bound Macadam Sub-base/base ( using stone screening) (B) By Mechanical means Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.- WBM Grading 2, As per directed by Engineer Incharge.
Tack Coat ii)on the prepared dry and hungry bituminous surface Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503., As per directed by Engineer Incharge.
Modified Penetration Macadam- Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506. A) 50 mm thick Bitumen (S-65) 60/70- VG-30, As per directed by Engineer Incharge.
Tack Coat i) Prepared bituminous surface- Above MPM-Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503., As per directed by Engineer Incharge.
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade) Binder By Mechanical Means- Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (excluding seal coat)- Bitumen ( S- 65) 60/70- VG-30 @ 1.460 kg per sqm , As per directed by Engineer Incharge.
Seal Coat- Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A as per Technical Specification Clause 510, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 600 MM Equilateral Triangle, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 600 MM circular, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 800 x 600 MM rectangular, As per directed by Engineer Incharge.
Direction and Place Identification signs upto 0.9 sqm size board - Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTM D4956-09 specifications , fixed over 4mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with are as not exceeding 0.9sqm .Supported in mild steel angle iron post 75x75x6mm-3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT&H specification No.801)(for are a Less than 0.9 sqm). 7 Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting., As per directed by Engineer Incharge.
Reinforced cement concrete M15 grade Kilometer stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703, As per directed by Engineer Incharge. ii) Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade 200 M. stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703, As per directed by Engineer Incharge. iii) 200 m stone (precast)
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704, As per directed by Engineer Incharge.- Boundary Pillar
Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete., As per directed by Engineer Incharge.
Providing and Fixing 'Logo' of PMGSY Project- Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1, As per directed by Engineer Incharge.
Sign Board of MMGSY / PMGSY Project Information-: Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor, As per directed by Engineer Incharge.
Citizen/Maintenance Information Board-MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDAP 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4, As per directed by Engineer Incharge.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures i) Ordinary Soil
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures i) Ordinary Rock ( not requiring blasting )
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures Hard rock ,IV. (blasting prohibited)
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, As per directed by Engineer Incharge.- P.C.C grade M 10
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204, As per directed by Engineer Incharge. P.C.C grade M 15
Providing and Laying Reinforced Cement Concrete Pipe NP3 of 1000 mm dia as per Design in Three/Two/Single Row- Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Providing and Laying Reinforced Cement Concrete Pipe NP2 of 600 mm dia as per Design in Single Row- Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Providing and Laying Reinforced Cement Concrete Pipe NP3 of 600mm dia as per Design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
R.C.C.pipe Np class of 300mm dia. 2m long- Providing and laying concrete pipes of I.S.NP.class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete., As per directed by Engineer Incharge.
Gabion wall- Providing and Constructing gabion structure 1 Meter high or required section made up of soft mechanically woven hexagonal shaped G.I. wire confirming to IS16014:2012 having zinc plus PVC coating of over all diameter of 3.7mm and tying lacingwire of 3.2 mm with edge wire confirming to over all dia meter 4.4 mm edges being mechanically selvedge including placing in position,fitting neatly with trap stone rubble(15 to23 cm) all loose ends to be securely tied( Excluding transportation) etc.complete.( In Dry condition and for under water installation extra cost to be considered), As per directed by Engineer Incharge.
4) Proposed Upgradation/ Improvement and Maintenance of road from TR-16 to Aral (Divshi Bk) from ch 0/000 to ch 3/430 Tal- Patan, Dist-Satara. Clearing and Grubbing Road Land-By mechenical means-In area of non-thorny jungle- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including all lifts, leads and including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201, As per directed by Engineer Incharge.
Clearing and Grubbing Road Land-By mechenical means-In area of thorny jungle-Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth up to 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned,up to a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as perTechnical Specification Clause 201., As per directed by Engineer Incharge.
Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with all lifts and leads as per Technical Specification Clause 301.4, As per directed by Engineer Incharge.
Dismantling Stone Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material including all lifts and leads as per Technical Specification Clause 202, As per directed by Engineer Incharge. Rubble Stone Masonry in Cement Mortar
Above 600 mm to 900 mm dia Hume pipe-Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202, As per directed by Engineer Incharge.
Construction of Embankment with Material Obtained from Roadway Cutting- Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5, As per directed by Engineer Incharge.
Construction of Embankment with Material Obtained from borrow pits- Construction of embankment with approved material obtained from borrow pits with all lifts, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5, As per directed by Engineer Incharge.
Excavation in Soil using Hydraulic Excavator and Tippers with disposal - Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location including all lifts and leads as per Technical Specification Clause 302.3, As per directed by Engineer Incharge.
Removal of Unsuitable Soil and Disposal - Removal of unsuitable soil including excavation, loading and disposal including all lifts lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11, As per directed by Engineer Incharge.
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal - Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site including all lifts and leads, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5, As per directed by Engineer Incharge.
Excavation in Hard Rock (blasting prohibited) (Mechanical Means)-Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal including all lifts and leads, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5, As per directed by Engineer Incharge.
Construction of Subgrade and Earthen Shoulders-Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 including all lifts and leads as per Technical Specification Clause 303.1., As per directed by Engineer Incharge.
Granular Sub-base with Well Graded Material (Table 400.1) - By Mix in Place Method - For Grading II Material- Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401., As per directed by Engineer Incharge.
Water bound macadam with crushable screening (B) by mechenical means WBM grading 2-Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405., As per directed by Engineer Incharge.
Water Bound Macadam Sub-base/base ( using stone screening) (B) By Mechanical means Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.- WBM Grading 2, As per directed by Engineer Incharge.
Tack Coat ii)on the prepared dry and hungry bituminous surface Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503., As per directed by Engineer Incharge.
Modified Penetration Macadam- Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506. A) 50 mm thick Bitumen (S-65) 60/70- VG-30, As per directed by Engineer Incharge.
Tack Coat i) Prepared bituminous surface- Above MPM-Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503., As per directed by Engineer Incharge.
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade) Binder By Mechanical Means- Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (excluding seal coat)- Bitumen ( S- 65) 60/70- VG-30 @ 1.460 kg per sqm , As per directed by Engineer Incharge.
Seal Coat- Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A as per Technical Specification Clause 510, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 600 MM Equilateral Triangle, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 600 MM circular, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 800 x 600 MM rectangular, As per directed by Engineer Incharge.
Direction and Place Identification signs upto 0.9 sqm size board - Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTM D4956-09 specifications , fixed over 4mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with are as not exceeding 0.9sqm .Supported in mild steel angle iron post 75x75x6mm-3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT&H specification No.801)(for are a Less than 0.9 sqm). 7 Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting., As per directed by Engineer Incharge.
Reinforced cement concrete M15 grade Kilometer stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703, As per directed by Engineer Incharge. ii) Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade 200 M. stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703, As per directed by Engineer Incharge. iii) 200 m stone (precast)
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704, As per directed by Engineer Incharge.- Boundary Pillar
Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete., As per directed by Engineer Incharge.
Providing and Fixing 'Logo' of PMGSY Project- Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1, As per directed by Engineer Incharge.
Sign Board of MMGSY / PMGSY Project Information-: Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor, As per directed by Engineer Incharge.
Citizen/Maintenance Information Board-MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDAP 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4, As per directed by Engineer Incharge.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures i) Ordinary Soil
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures i) Ordinary Rock ( not requiring blasting )
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures Hard rock ,IV. (blasting prohibited)
Rubble Filling (For B.C. Soil)- Filling in foundation trenches as per drawing and technical specification Clause 305.3.9, As per directed by Engineer Incharge.
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, As per directed by Engineer Incharge.- P.C.C grade M 10
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204, As per directed by Engineer Incharge. P.C.C grade M 15
Providing and Laying Reinforced Cement Concrete Pipe NP3 of 1000 mm dia as per Design in Three/Two/Single Row- Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Providing and Laying Reinforced Cement Concrete Pipe NP2 of 600 mm dia as per Design in Single Row- Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Providing and Laying Reinforced Cement Concrete Pipe NP3 of 600mm dia as per Design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
R.C.C.pipe Np class of 300mm dia. 2m long- Providing and laying concrete pipes of I.S.NP.class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete., As per directed by Engineer Incharge.
Gabion wall- Providing and Constructing gabion structure 1 Meter high or required section made up of soft mechanically woven hexagonal shaped G.I. wire confirming to IS16014:2012 having zinc plus PVC coating of over all diameter of 3.7mm and tying lacingwire of 3.2 mm with edge wire confirming to over all dia meter 4.4 mm edges being mechanically selvedge including placing in position,fitting neatly with trap stone rubble(15 to23 cm) all loose ends to be securely tied( Excluding transportation) etc.complete.( In Dry condition and for under water installation extra cost to be considered), As per directed by Engineer Incharge.
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)", As per directed by Engineer Incharge.
5) Proposed Upgradation/ Improvement and Maintenance of road from LR-174 to Vitthalwadi from ch 0/000 to ch 3/200 Tal- Patan, Dist-Satara. Clearing and Grubbing Road Land-By mechenical means-In area of non-thorny jungle- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including all lifts, leads and including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201, As per directed by Engineer Incharge.
Clearing and Grubbing Road Land-By mechenical means-In area of thorny jungle-Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth up to 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned,up to a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as perTechnical Specification Clause 201., As per directed by Engineer Incharge.
Compacting Original Ground- Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2for embankment construction as per Technical Specification Clause 301.4.1., As per directed by Engineer Incharge.
Scarifying Existing Bituminous Surface to a Depth of 150 mm by Mechanical Means Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with all lifts and leads as per Technical Specification Clause 301.4, As per directed by Engineer Incharge.
Dismantling Stone Masonry as per Technical Specification Clause 202. Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material including all lifts and leads as per Technical Specification Clause 202, As per directed by Engineer Incharge. Rubble Stone Masonry in Cement Mortar
Above 600 mm to 900 mm dia Hume pipe-Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202, As per directed by Engineer Incharge.
Construction of Embankment with Material Obtained from Roadway Cutting- Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5, As per directed by Engineer Incharge.
Construction of Embankment with Material Obtained from borrow pits- Construction of embankment with approved material obtained from borrow pits with all lifts, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5, As per directed by Engineer Incharge.
Excavation in Soil using Hydraulic Excavator and Tippers with disposal - Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location including all lifts and leads as per Technical Specification Clause 302.3, As per directed by Engineer Incharge.
Removal of Unsuitable Soil and Disposal - Removal of unsuitable soil including excavation, loading and disposal including all lifts lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11, As per directed by Engineer Incharge.
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal - Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site including all lifts and leads, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5, As per directed by Engineer Incharge.
Excavation in Hard Rock (blasting prohibited) (Mechanical Means)-Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal including all lifts and leads, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5, As per directed by Engineer Incharge.
Construction of Subgrade and Earthen Shoulders-Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 including all lifts and leads as per Technical Specification Clause 303.1., As per directed by Engineer Incharge.
Granular Sub-base with Well Graded Material (Table 400.1) - By Mix in Place Method - For Grading II Material- Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401., As per directed by Engineer Incharge.
Water bound macadam with crushable screening (B) by mechenical means WBM grading 2-Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405., As per directed by Engineer Incharge.
Water Bound Macadam Sub-base/base ( using stone screening) (B) By Mechanical means Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.- WBM Grading 2, As per directed by Engineer Incharge.
Tack Coat ii)on the prepared dry and hungry bituminous surface Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503., As per directed by Engineer Incharge.
Modified Penetration Macadam- Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506. A) 50 mm thick Bitumen (S-65) 60/70- VG-30, As per directed by Engineer Incharge.
Tack Coat i) Prepared bituminous surface- Above MPM-Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503., As per directed by Engineer Incharge.
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade) Binder By Mechanical Means- Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (excluding seal coat)- Bitumen ( S- 65) 60/70- VG-30 @ 1.460 kg per sqm , As per directed by Engineer Incharge.
Seal Coat- Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A as per Technical Specification Clause 510, As per directed by Engineer Incharge.
Cement Concrete Pavement- Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel,, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 600 MM Equilateral Triangle, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 600 MM circular, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 800 x 600 MM rectangular, As per directed by Engineer Incharge.
Direction and Place Identification signs upto 0.9 sqm size board - Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTM D4956-09 specifications , fixed over 4mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with are as not exceeding 0.9sqm .Supported in mild steel angle iron post 75x75x6mm-3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT&H specification No.801)(for are a Less than 0.9 sqm). 7 Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting., As per directed by Engineer Incharge.
Reinforced cement concrete M15 grade Kilometer stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703, As per directed by Engineer Incharge. ii) Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade 200 M. stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703, As per directed by Engineer Incharge. iii) 200 m stone (precast)
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704, As per directed by Engineer Incharge.- Boundary Pillar
Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete., As per directed by Engineer Incharge.
Providing and Fixing 'Logo' of PMGSY Project- Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1, As per directed by Engineer Incharge.
Sign Board of MMGSY / PMGSY Project Information-: Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor, As per directed by Engineer Incharge.
Citizen/Maintenance Information Board-MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDAP 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4, As per directed by Engineer Incharge.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures i) Ordinary Soil
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures i) Ordinary Rock ( not requiring blasting )
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures Hard rock ,IV. (blasting prohibited)
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, As per directed by Engineer Incharge.- P.C.C grade M 10
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204, As per directed by Engineer Incharge. P.C.C grade M 15
Providing and Laying Reinforced Cement Concrete Pipe NP3 of 1000 mm dia as per Design in Three/Two/Single Row- Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Providing and Laying Reinforced Cement Concrete Pipe NP2 of 600 mm dia as per Design in Single Row- Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Providing and Laying Reinforced Cement Concrete Pipe NP3 of 600mm dia as per Design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Gabion wall- Providing and Constructing gabion structure 1 Meter high or required section made up of soft mechanically woven hexagonal shaped G.I. wire confirming to IS16014:2012 having zinc plus PVC coating of over all diameter of 3.7mm and tying lacingwire of 3.2 mm with edge wire confirming to over all dia meter 4.4 mm edges being mechanically selvedge including placing in position,fitting neatly with trap stone rubble(15 to23 cm) all loose ends to be securely tied( Excluding transportation) etc.complete.( In Dry condition and for under water installation extra cost to be considered), As per directed by Engineer Incharge.
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)", As per directed by Engineer Incharge.
6) Proposed Upgradation/ Improvement and Maintenance of road from TR-17 TO Kalambe Road from ch 0/000 to ch 1/600 Tal- Patan, Dist-Satara. Clearing and Grubbing Road Land-By mechenical means-In area of non-thorny jungle- Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including all lifts, leads and including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201, As per directed by Engineer Incharge.
Clearing and Grubbing Road Land-By mechenical means-In area of thorny jungle-Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth up to 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned,up to a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as perTechnical Specification Clause 201., As per directed by Engineer Incharge.
Construction of Embankment with Material Obtained from Roadway Cutting- Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5, As per directed by Engineer Incharge.
Construction of Embankment with Material Obtained from borrow pits- Construction of embankment with approved material obtained from borrow pits with all lifts, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5, As per directed by Engineer Incharge.
Excavation in Soil using Hydraulic Excavator and Tippers with disposal - Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location including all lifts and leads as per Technical Specification Clause 302.3, As per directed by Engineer Incharge.
Removal of Unsuitable Soil and Disposal - Removal of unsuitable soil including excavation, loading and disposal including all lifts lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11, As per directed by Engineer Incharge.
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal - Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site including all lifts and leads, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5, As per directed by Engineer Incharge.
Excavation in Hard Rock (blasting prohibited) (Mechanical Means)-Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal including all lifts and leads, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5, As per directed by Engineer Incharge.
Construction of Subgrade and Earthen Shoulders-Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 including all lifts and leads as per Technical Specification Clause 303.1., As per directed by Engineer Incharge.
Granular Sub-base with Well Graded Material (Table 400.1) - By Mix in Place Method - For Grading II Material- Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401., As per directed by Engineer Incharge.
Water bound macadam with crushable screening (B) by mechenical means WBM grading 2-Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405., As per directed by Engineer Incharge.
Water Bound Macadam Sub-base/base ( using stone screening) (B) By Mechanical means Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.- WBM Grading 2, As per directed by Engineer Incharge.
Tack Coat ii)on the prepared dry and hungry bituminous surface Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503., As per directed by Engineer Incharge.
Modified Penetration Macadam- Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506. A) 50 mm thick Bitumen (S-65) 60/70- VG-30, As per directed by Engineer Incharge.
Tack Coat i) Prepared bituminous surface- Above MPM-Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503., As per directed by Engineer Incharge.
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade) Binder By Mechanical Means- Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (excluding seal coat)- Bitumen ( S- 65) 60/70- VG-30 @ 1.460 kg per sqm , As per directed by Engineer Incharge.
Seal Coat- Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A as per Technical Specification Clause 510, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 600 MM Equilateral Triangle, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 600 MM circular, As per directed by Engineer Incharge.
Traffic Signs - B) Semi Reflective Traffic Signs- Providing and Fixing of Retro Reflectorised 900 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTMD 4956 09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 25 x 25x3 mm mild steel angle as approved, supported on a mild steel angle iron post 65 mm X 65mm X6 mm 3.5 m tr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cmX 45cm X60cm, 60 cm below ground level as per approved drawing. Both border & background shall be retroreflective as per TypeIV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & acertified copy of thre eyears outdoor exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be atleast 2.6 mtr. above ground level)Specification: IRC 67: 2012. There shall be astamp behind the ACP sheet carrying then ame of the supplier ,Name of sheeting Manufacturer ,Type of retroreflective sheeting, Installation month & year ,Warranty period for retro reflective sheeting. 800 x 600 MM rectangular, As per directed by Engineer Incharge.
Direction and Place Identification signs upto 0.9 sqm size board - Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retroreflective sheeting of High Intensity prismatic grade conforming to IRC-67:2012 & Type IV standards of ASTM D4956-09 specifications , fixed over 4mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with are as not exceeding 0.9sqm .Supported in mild steel angle iron post 75x75x6mm-3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M20 grade cement concrete 45cmX45cmX60cm, 60cm below ground level complete (as per MoRT&H specification No.801)(for are a Less than 0.9 sqm). 7 Both border & back ground shall be retroreflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years out door exposurere port from an independent test lab for the product of fered shall be submitted by the contractor (Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting., As per directed by Engineer Incharge.
Reinforced cement concrete M15 grade Kilometer stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703, As per directed by Engineer Incharge. ii) Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M15 grade 200 M. stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703, As per directed by Engineer Incharge. iii) 200 m stone (precast)
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704, As per directed by Engineer Incharge.- Boundary Pillar
Thermoplastic Compound Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorizing glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete., As per directed by Engineer Incharge.
Providing and Fixing 'Logo' of PMGSY Project- Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1, As per directed by Engineer Incharge.
Sign Board of MMGSY / PMGSY Project Information-: Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor, As per directed by Engineer Incharge.
Citizen/Maintenance Information Board-MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDAP 013 (11) /3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4, As per directed by Engineer Incharge.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures i) Ordinary Soil
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures i) Ordinary Rock ( not requiring blasting )
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal including all lifts and leads, dressing of sides and bottom and backfilling in trenches with excavated suitable material., As per directed by Engineer Incharge. Excavation for Structures Hard rock ,IV. (blasting prohibited)
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, As per directed by Engineer Incharge.- P.C.C grade M 10
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204, As per directed by Engineer Incharge. P.C.C grade M 15
Providing and Laying Reinforced Cement Concrete Pipe NP3 of 1000 mm dia as per Design in Three/Two/Single Row- Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Providing and Laying Reinforced Cement Concrete Pipe NP2 of 600 mm dia as per Design in Single Row- Providing and laying reinforced cement concrete pipe NP2 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Providing and Laying Reinforced Cement Concrete Pipe NP3 of 600mm dia as per Design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106., As per directed by Engineer Incharge.
Gabion wall- Providing and Constructing gabion structure 1 Meter high or required section made up of soft mechanically woven hexagonal shaped G.I. wire confirming to IS16014:2012 having zinc plus PVC coating of over all diameter of 3.7mm and tying lacingwire of 3.2 mm with edge wire confirming to over all dia meter 4.4 mm edges being mechanically selvedge including placing in position,fitting neatly with trap stone rubble(15 to23 cm) all loose ends to be securely tied( Excluding transportation) etc.complete.( In Dry condition and for under water installation extra cost to be considered), As per directed by Engineer Incharge.
Metal Beam Crash Barrier -- Type - A, W : Metal Beam Crash Barrier (Providing and erecting a W "metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)", As per directed by Engineer Incharge.
UNITY BUILDERS AND ROAD CONSTRUCTIONS PVT LTD
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .