MANNING AND OPERATION OF CERTAIN AC PLANTS PUMP HOUSE AT COD AGRA AND REPAIR CERTAIN CONNECTED ITEMS UNDER AGE EM W OF GE W AGRA
2021_MES_420250_1
8012/786/E8
Open Tender
Civil Works
Item Rate
330 days
Ge West Agra
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Ge West Agra
₹75,000
19 Apr 2021
9 Feb 2021
22 Mar 2021
9 Feb 2021
18 Mar 2021
24 Feb 2021
Amount
Operation and routine maintenance of packaged type air conditioning plants of capacities (2 x 11TR- 03 Nos of Zone-1 B-1) , (2 x 11TR- 02 Nos of Zone-1 B-2), (2 x 11TR- 03 Nos of Zone-2 D-1) and (2 x 11TR- 02 Nos & 2x 5.5TR-01 No of Zone-1 D-2) of Adm Bldg of COD at Ground floor by one operator for one (01) shift, 8.00 to 16.00 hrs, of 08 Hrs each per day except Sunday and closed Holidays for its smooth functioning by maintaining temperature 25ºC+2ºC and humidity 50% + 5% inside the building including cleaning of plant and its surrounding, maintaining printed log sheet (daily, weekly, monthly, quarterly & half yearly) and routine maintenance and detection of leakage & its rectification including charging of refrigerant gas and compressor oil, maintaining temperature record register duly signed by user complete all as specified and directed.
Notes:- (i) Refrigerant gas for charging and compressor oil for filling shall be measured and paid separately as supply only under respective item here-in-after for charging/ filling only. (ii) Contractor shall provide the log sheets of Performa as approved by Engineer-in-Charge for maintain the records. (iii) Contractor shall responsible for maintain the temperature & humidity to the required level inside the bldg/ shed, failing which a recovery of Rs. 1000.00 per day shall be made from the contractor's dues. (iv) Contractor shall appoint the ITI trained operator in the trade of Ref Mechanic/ Electrical or equivalent qualification having minimum 3 years experience in similar trade. (v) Contractor shall be responsible for providing security pass to the operator.
All as per item No 1 above, but packaged type air conditioning plants of capacities (2 x 11TR- 03 Nos of Zone-3 B-1), (2 x 11TR- 02 Nos of Zone-3 B-2), (2 x 11TR- 03 Nos of Zone-4 D-1) , (2 x 11TR- 02 Nos of Zone-4 D-2) & (2 x 11TR- 03 Nos of Zone-5 C-1) of newly constructed Adm Bldg of COD Tech Area at First floor by one operator for one (01) shift, 8.00 to 16.00 hrs, of 08 Hrs each per day
All as per item No 1 above, but packaged type air conditioning plants of capacities (1 x 8.75 TR- 01 No & 2 x 11TR- 01 No of Zone-6 B-1), (2 x 11 TR- 02 Nos of Zone-6 B-2) , (2 x 11 TR- 02 Nos of Zone-7 D-1), (2 x 11 TR- 02 Nos of Zone-7 D-2) and (2 x 11 TR- 03 Nos of Zone-8 C-1) of newly constructed Adm Bldg of COD Tech Area at Second floor by one operator for one (01) shift, 8.00 to 16.00 hrs, of 08 Hrs each per day.
All as per item No 1 above, but packaged type air conditioning plants of capacities (2 x 11TR- 03 Nos AHU-1), (2 x 11TR- 03 Nos AHU-2), (2 x 11TR- 01 No), (1 x 8.75 TR-01 No AHU-3) and (2 x 11TR- 03 Nos AHU-4) of EDW Zone-1 Bldg of COD Tech Area by one operator for one (01) shift, 8.00 to 16.00 hrs, of 08 Hrs each per day.
All as per item No 1 above, but packaged type air conditioning plant of capacity (2 x 8.75 TR- 03 Nos Zone-1), (2 x 11 TR- 02 Nos Zone-2) & (2 x 11 TR- 02 Nos Zone-3) of P-3 Bldg of COD Tech Area at Ground floor by one operator for one (01) shift, 8.00 to 16.00 hrs, of 08 Hrs each per day.
Manning & Operation and comprehensive maintenance of central Air conditioning plant unit of capacity 2x5.5 TR-02 Nos of medical store and air conditioning plants of capacity 2x8.75TR -02 Nos at Medical Ward (Both plant shall be run for three shift of 08 hours each ir round the clock) both plants located within 200 mtrs distance at MH Agra by one operator on all days including Sunday and closed holidays for its smooth functioning by maintaining designed temperature & humidity in side the shed/ space including cleaning of plants and its surrounding maintaining log sheet (daily, weekly monthly, quarterly & half yearly) and routine maintenance and detection of leakage & its rectification including charging of refrigerant gas and compressor oil complete all as specified and directed Notes:- (i) Refrigerant gas for charging and compressor oil for filling shall be measured and paid separately as supply only under respective item here in after for charging/ filling only. (ii) contractor shall provided the log sheets of Performa as approved by Engineer -in-Charge for maintain the records. (iii) Contractor shall responsible for maintain the temperature & humidity to the required level inside the bldg/shed, falling which a recovery of Rs 1000.00 per day shall be made from the contractor's dues. (iv) Contractor shall be appoint the ITI trained operator in the trade of Ref Mechanic/ Electrical or equivalent having minimum 3 years experience in similar trade. (v) Contractor shall be responsible for security pass to the operator.
Manning & Operation of Central AC Plant of capacity mentioned in item No. 1 to 5 here in above but for additional period of time required after official timings on users requirement basis by employing ITI qualified Refrigerator Mechanic complete all as specified and directed. Notes for Item No. 1 to 5:- The staff employed shall be responsible to maintain Inside Temperature 25ºC+2ºC Humidity 50 + 5% during operation of plant :- (i) Lowest rate will be applicable if the rates of this item higther than the proportional rate of item no 1 to 5 above. (ii) Separate employee will be employed for this item. (iii) Engr-in-charge ensure that this item can not be applicable as daily or in rutine.
Manning and operation of PUMP HOUSE (Water supply installation) at newly constructed COD under GE (W) Agra including operation of DG set and FIRE fighting system such as pumps,electric control pannel, internal and external electrificaiton of water supply/ fire fighting system, operation of valves of over head tanks pertains under installation during staggered timings in morning, evening and night depending upon the availability of water from Yamuna river/ borewell, daily maintenance and upkeep of log book, daily/ weekly/ monthly maintenance of installation and complete machineries by employing 01 (ONE) No. skilled appropriate category of (FGM) per shift in 03 shifts i.e. 8.00 to 16.00 hrs, 16.00 to 24.00 hrs and 0.00 to 08 hrs per day i.e. for round the clock including Sunday & Holidays complete all as directed including comprising of the following :-
(i) Drinking water motor pump set of capacity 12.5 HP - 02 Nos (ii) Online Chlorination System with control Panel and pump set-01 No (iii) Dry motor submerssible pump set of capacity 2HP/ 1.5KW -01 No (iv) Jockey motor pump set of capacity 10 HP -01 No (v) Fire fighting water (electric driven) main pump set of capacity 100 HP- 01 No (vi) Fire fighting water (diesel engine driven) main pump set of capacity 105 HP- 01 No (vii) Submersible pump set of capacity 7.5 HP- 03 Nos with control Panels. (viii) All sluice valve, NRV, ARV, fire hydrent, hose box, fire hose etc. (ix) Automatic electric control panels- 02 Nos. (x) Operation of valves of over head tank & pump set raising mains and distribution at different locations as required and as directed for contineous and smooth water supply to the concerned area.
Notes:- (i) Diesel for running the DG set shall be issued to the contractor under Sch ‘B’ for free for filling. (ii) Contractor shall provide the log sheets of proforma as approved by Engineer-in-Charge for maintain the records. (iii) Contractor shall be responsible for routine maintenance of pump glands leakage, valve leakage, attending of minor electrical faults in panel/ circuit and its rectification complete all as specified and as directed and quoted rate for this item shall be deemed to be included for these provisions. (iv) Cost of fixing/ refixing/ removing of items & all type of tools as required deemed to be included in the unit rates. (v) Contractor shall responsible for contineous and smooth water supply to the concerned area, if contractor fails to supply the water due to any reason other than department faults, a penaulty recovery of Rs. 2000.00 per day shall be made from the contractor's dues. (vi) Maintenance of batteries such as filling of distilled water, replacement of battery terminals and other required materials for making the batteries functional. (vii) Operator shall be responsible for testing of chlorination in water at pump house & all required testing materials and shall also be responsible for maintain the daily records of testing and quoted rate for this item shall be deemed to be included for these provisions. (vii) Contractor shall be responsible for security pass to the operator.
Labour only for servicing / repairing of package type central AC plant unit ( out door and Indoor unit, AHU) where required in ACs or as directed by Engr-in-Charge Or concern JE at site of COD to attend and rectfy the defects by settings of controls or by repair/ replacement work to air conditioning plant unit/ system etc as per standard engineering practice,along with all necessary tools etc and keeping proper record of maintenance record in register supplied by the contractor) .. Notes:- (i) Spare parts required for repair/ rectification of defects shall be measured and paid saperatly under respactive items here in after. (ii) Contractor will ensure proper functioning of All AC plants at all workig days times. (iii) Repair work of plant shall be carried out by well experienced technitions/ mechanic with proper tools and safety measures. (iv) All petty small parts required for repair i.e. nuts, bolts, washers screws, saddles, grease, oil/ lubricants etc shall be provided by the contractor without any extra cost to the government. (vi) Location and place of complaints shall be as per requirement of maintenance work of bldg in different areas of COD under GE (W) Agra as directed by Engineer in charge/ JE concerned. (vi) Contractor shall be responsible to provide conveyence and required T&P for attend the complaints. (vii) Contractorshall be responsible for security pass to the mechanic
Labour only for servicing / repairing of water supply/ fire fighting system / installations where required or as directed by Engr-in-Charge Or concern JE at site of COD to attend and rectfy the defects by settings of controls or by repair/ replacement work to water supply installations/ fire fighting system etc as per standard engineering practice,along with all necessary tools etc and keeping proper record of maintenance record in register supplied by the contractor) .. Notes:- (i) Spare parts required for repair/ rectification of defects shall be mesured and paid saperatly under respactive items here in after or issued by deptt free for fixing only.. (ii) Contractor will ensure proper functioning of All installations at all workig days times. (iii) Repair work of plant shall be carried out by well experienced technitions/ mechanic with proper tools and safety measures. (iv) All petty small parts required for repair i.e. nuts, bolts, washers screws, saddles, grease, oil/ lubricants etc shall be provided by the contractor without any extra cost to the government. (vi) Location and place of complaints shall be as per requirement of maintenance work of bldg in different areas of COD under GE (W) Agra as directed by Engineer in charge/ JE concerned. (vi) Contractor shall be responsible to provide conveyence and required T&P for attend the complaints. (vii) Contractorshall be responsible for security pass to the mechanic
Cleaning all filters of AHUs alongwith its out door unit of COD Adm Bldg, EDW, P-3 shed and medical store and cleaning the filters with the help of blower, suitable cleaning materials and water to remove the complete dust particles and refixing the same to its original position including checking of tightness of all the nuts & bolts of compressor, blower motor, condensor motor, out door units and combing of bend fins of out door units complete as directed. Note: All filters and outdoor units shall be cleaned fortnightly basis upto completion of the work.
Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen and oxygen gas in package type AC units,Model No. DPUASC 220X,having compressor's capacity 1x11.0 TR and material & labour for repairing the leakage if detected, vaccum & checking for vaccum pressure holding stand for 24 hrs and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed. Note:- Refrigerant gas (M-22) and compressor oil shall be measured and paid saperatly under respactive item herein after.
Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen and oxygen gas in package type AC units, Model No. DPUASC 875, having compressor's capacity 1x8.75 TR and material & labour for repairing the leakage if detected, vaccum and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed. Note:- Refrigerant gas (M-22) and compressor oil shall be measured and paid saperatly under respactive item herein after.
Checking/ detecting and arresting/rectifiying of the leakage by putting nitrogen and oxygen gas in package type AC units,Model No. DPUASC 550, having compressor's capacity 1x5.50 TR and material & labour for repairing the leakage if detected, vaccum and charging the refrigerant gas (M-22) as required and top up of compressor oil if required complete all as specified and directed. Note:- Refrigerant gas (M-22) and compressor oil shall be measured and paid saperatly under respactive item herein after.
Supply only the new sealed compressor of package type ACs of capacity 11.0 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed. Make:- Danfoss Model No. SM 147 A4NLB or equivalent model of make Emerson/ Voltas as approved by GE. Notes:- (i) Refrigerant gas (R-22) and compressor oil shall be measured and paid saperatly under respactive item after for filling/topping up only. (ii) Contractor shall submit the manufacturer test certificate of compressor alongwith purchase vouchers to Engr-in-Charge for their verification and kept on record.
Supply only the new sealed compressor of package type ACs of capacity 8.75 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed. Make:- Danfoss Model No. SM 110 S4EA or equivalent model of make Emerson/ Voltas as approved by GE. Notes:- (i) Refrigerant gas (R-22) and compressor oil shall be measured and paid saperatly under respactive item after for filling/topping up only (ii) Contractor shall submit the manufacturer test certificate of compressor alongwith purchase vouchers to Engr-in-Charge for their verification and kept on record.
Supply only the new sealed compressor of package type ACs of capacity 5.50 TR with and including anti vibration pad complete and repairing the leakage if detected after fixing/ fitting the compressor, vaccum and charging the refrigerant gas (R-22) as required and top up of compressor oil if required and testing on completion complete all as specified and directed. Make:- Danfoss Model No. HLM 072 T4LC6 or equivalent model of make Emerson/ Voltas as approved by GE. Notes:- (i) Refrigerant gas (R-22) and compressor oil shall be measured and paid saperatly under respactive item after for filling/topping up only (ii) Contractor shall submit the manufacturer test certificate of compressor alongwith purchase vouchers to Engr-in-Charge for their verification and kept on record.
Supply only, thermostatic expansion valves suitable for 1x11 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed. Make:- Danfoss or Sporlong or Alco or Emerson as approved by GE.
Supply only, thermostatic expansion valves suitable for 1x8.75 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed. Make:- Danfoss or Sporlong or Alco or Emerson as approved by GE.
Supply only, thermostatic expansion valves suitable for 1x5.50 TR package type AC unit, working temp 110 centigrade and maximum operating pressure 68 PSI complete all as specified and directed. Make:- Danfoss or Sporlong or Alco or Emerson as approved by GE.
Supply only, moisture and liquid indicator suitable for 2x11 TR package type AC plants complete all as specified and directed. Make:- Danfoss or Sporlong or Alco or Emerson as approved by GE.
Supply only, eliminator filter drier complete all as specified and directed. Make:- Danfoss Model No. DCL 165 or equivalent model of make Emerson/ Sporlong/ Alco as approved by GE.
Supply only non freezing compressor oil of existing make in sealed containers of standard size complete all as specified and directed. Note : Item will be taken on charge for issu under Sch 'B' store.
Dismenteling & taking out existing defective/ burnt parts of AC electric blower motor of any description & in any position of capacity 5.0 HP for rewinding from approved workshop including transporting the same to workshop & back after rewinding the same motor with and including super enamelled copper winding wire of superior quality of existing size/ gauge & No of turns and insulation of the same with & including insulating materials such as leatherised fibre glass, illuminous paper, cotton tape, glass sleeving, insulating varnish etc as per manufacturers instructions including cutting and taking out existing burnt/ short circuited winding wires including replacement of existing bushes, bearings & starting condenser with new bushes, bearings & starting condenser complete and re-assembling and refixing of the same motor at its original position after repair, making all necessary connections, commissioning and testing on completion complete all as specified and directed. Make of winding wire : Atlas/ Finolex/ Devidayal as approved by GE.
Dismenteling & taking out existing defective/ burnt parts of AC electric condensor fan motor of any description & in any position of capacity 375W for rewinding from approved workshop including transporting the same to workshop & back after rewinding the same motor with and including super enamelled copper winding wire of superior quality of existing size/ gauge & No of turns and insulation of the same with & including insulating materials such as leatherised fibre glass, illuminous paper, cotton tape, glass sleeving, insulating varnish etc as per manufacturers instructions including cutting and taking out existing burnt/ short circuited winding wires including replacement of existing bushes, bearings & starting condenser with new bushes, bearings & starting condenser complete and re-assembling and refixing of the same motor at its original position after repair, making all necessary connections, commissioning and testing on completion complete all as specified and directed. Make of winding wire : Atlas/ Finolex/ Devidayal as approved by GE.
Supply only, fan belt of blower units of existing make complete all as specified and directed. Make : Fenner/Dunlop
Supply only, fan blade (three blade) of existing make & model of condensor units of capacity 11.0 TR complete all as specified and directed.
Supply only, fan blade (four blade) of existing make & model of condensor units of capacity 8.75 TR complete all as specified and directed.
Supply only, fan blade (four blade) of existing make & model of condensor units of capacity 5.50 TR complete all as specified and directed.
Supply only, contactor suitable for blower motor of capacity 7.5HP complete all as specified and directed. Make:- Siemens Cat No. 3TS31 10-0BB4 or equivalent model of L&T or ABB or Schneider as approved by GE.
Supply onlys, power contactor suitable for compressor motor of capacity 15.0HP complete all as specified and directed Make:- Siemens Cat No. 3TS3300-0AF02-8K or equivalent model of L&T or ABB or Schneider as approved by GE.
Supply only, auxiliary contact suitable for mounting on contactor (set of three) complete all as specified and directed. Make:- Siemens Cat No. 3TX40012A or equivalent model of L&T or ABB or Schneider as approved by GE.
Supply only, HRC catridge fuse 20A, (IS9224) complete all as specified and directed. Make:- Siemens or L&T or ABB or Schneider as approved by GE.
Supply only, glass fuses of rated 6 Amps complete all as specified and directed. Make:- Siemens or L&T or ABB or Schneider as approved by GE.
Supply only, PMN MPD type microprocessor based controller card (sensor, display card, MPD & relay card) having range 11 to 35 Amps suitable for 2X11 TR package type AC units complete all as specified and directed. Make:- Voltas or Blue Star as approved by GE.
Supply only, PMN MPD type microprocessor based controller card (sensor, display card, MPD & relay card) having range 7 to 22 Amps suitable for 1X8.75 TR package type AC units complete all as specified and directed .Make:- Voltas or Blue Star as approved by GE.
Supply only, PMN MPD type microprocessor based controller card (sensor, display card, MPD & relay card) having range 7 to 22 Amps suitable for 2X5.50 TR package type AC units complete all as specified and directed. Make:- Voltas or Blue Star as approved by GE.
Supply only, timer having range 1-10 Amps, 230 volts complete all as specified and directed. Make:- Model u-MPD-WOD of Soft Hard or equivalent model of make Voltas or Blue Star as approved by GE.
Supply only, connector three phase, 4-pole, 100 Amps rated complete all as specified and directed. Make:- Siemens or L&T or ABB or Schneider as approved by GE.
Supply only, connector single phase, 10 Amps rated complete all as specified and directed. Make:- Siemens or L&T or ABB or Schneider as approved by GE.
Supply only, heating element, 3KW, 240 volts, ISI marked suitable AHU chamber complete all as specified and directed. Make:- Danfoss or Dasspass as approved by GE.
Supply only, aucostic jali of existing/ approved pattern as in patchwork in AHU room of AC plants complete all as specified and directed.
Supply only, adjustable thermal & adjustable magnetic setting type MCCB three pole with enclosure, 415 volts, 50 Hz, 250 Amps with breaking capacity 25 kA complete all as specified & directed. Make:- Havells Cat No.IHLANDCT0250 # or equivalent of make L&T or Legrand as approved by GE.
Supply only, adjustable thermal & adjustable magnetic setting type MCCB three pole with enclosure, 415 volts, 50 Hz, 200 Amps with breaking capacity 25 kA complete all as specified & directed. Make:- Havells Cat No.IHLANDCT0200 # or equivalent of make L&T or Legrand as approved by GE.
Supply only, adjustable thermal & adjustable magnetic setting type MCCB three pole with enclosure, 415 volts, 50 Hz, 100 Amps with breaking capacity 25 kA complete all as specified & directed. Make:- Havells Cat No.IHLASDCT0100 # or equivalent of make L&T or Legrand as approved by GE.
Supply only, adjustable thermal & fixed magnetic setting type MCCB three pole with enclosure, 415 volts, 50 Hz, 63 Amps with breaking capacity 25 kA complete all as specified & directed. Make:- Havells Cat No.IHLAST0063 or equivalent of make L&T or Legrand as approved by GE.
Supply only, control fuse with base of capacity 2 to 20 Amps complete all as specified and directed. Make:- Siemens or L&T or ABB or Schneider as approved by GE.
Supply only, earth fault relay with CBCT, 230 volts AC, coil of capacity 0-100 Amps complete all as specified and directed. Make:- Siemens or L&T or ABB or Schneider as approved by GE.
Supply only, earth fault relay with CBCT, 230 volts AC, coil of capacity 0-40 Amps complete all as specified and directed. Make:- Siemens or L&T or ABB or Schneider as approved by GE.
Supply only, contactor 3 pole with AC coil of capacity 25 Amps complete all as specified and directed. Make:- Siemens or L&T or ABB or Schneider or BCH as approved by GE.
Supply only, indication lamp LED type, 22.5mm dia, 230 volts complete all as specified and directed.
Supply only, MCB TP, 'C' series, 63 Amps, 415 volts, 50Hz, 10kA complete all as specified & directed.
Supply only MCB TP, 'C' series, 40 Amps, 415 volts, 50Hz, 10kA complete all as specified & directed.
Supply only refrigrant gas M-22 in cylinders of required capacity including transportation, loading/ unloading and collection of empty cylinders from MES store yard of AGE E/M and returned the same cylinder or other cylinder duly filled and testing of cylindeers including test certificate by authorised agencies complete all as specified and directed. Note : Item will be taken on charge for issu under Sch 'B' store.
M&L for fixing new evaporative/cooling coil in replacement of existing in door unit including jointing all liquid and gas lines duly sholdering, breazing , copper welding all as per manufacturer of capacity 22 TR capacity, model DPUASC22OX of Voltas Make complete all as directed at site.
Supply only heavy duty copper tubing suitable for package type AC unit gas piping of size 9/8" with insulating material and fixing supports/ saddles etc as required at site to match existing line complete all as specified and directed.
Supply only heavy duty copper tubing suitable for package type AC unit gas piping of size 7/8" with insulating material and fixing supports/ saddles etc as required at site to match existing line complete all as specified and directed.
Supply & Fixing in repair pin type HP/LP cut out switch suitable for and including fixing by copper welding on discharge/suction line of 11 to 5.5 TR capacity package type AC plant unit as per site requirement complete all as specified and directed. Make : Danfoss/Indfoss or equivalant make.
Supply & Fixing in repair discharge/suction line valve o size 9/8" to 7/8" of 11 suitable for and including fixing by copper welding on discharge/suction line of 11 to 5.5 TR capacity package type AC plant unit as per site requirement complete all as specified and directed. Make : Voltas/Blue star/Hitachi
Gupta Automobiles
M/s Yash Trading Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .