Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-AOC | ₹33.7 L | L1 | Accepted-AOC Accepted being lowest bidder |
| 2 | L2₹37.9 L+₹4.2 L (12.3%)Rejected-Finance | ₹37.9 L+₹4.2 L (12.3%) | L2 | Rejected-Finance Rejected being not lowest bidder |
| 3 | L3₹42.5 L+₹8.8 L (26.0%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | ₹42.5 L+₹8.8 L (26.0%) | L3 | Rejected-Finance Rejected being not lowest bidder |
| 4 | L4₹47.4 L+₹13.7 L (40.5%)Rejected-Finance | ₹47.4 L+₹13.7 L (40.5%) | L4 | Rejected-Finance Rejected being not lowest bidder |
Tender Value
₹47.2 L
EMD Value
₹94,500
Closing Date
29 May 2021, 6:00 pmClosed
CWE KIRKEE
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
SPECIAL REPAIRS TO BUILDING NO- P-5 (GYMNASTICS)OF BEG AND CENTRE KIRKEE UNDER GE (C )KIRKEE
2021_MES_438687_1
CWE/KKE/TOKEN-01 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Kirkee
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹94,500
Yes
Headquarters CWE Kirkee, Military Engineer Service
3 Aug 2021
27 Apr 2021
31 May 2021
27 Apr 2021
29 May 2021
18 May 2021
28 Apr 2021 - 3 May 2021
3 May 2021
Amount
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
Dismantling of existing snap grid framework of wooden/aluminium of any description,type,size and thickness in any position as in ceiling upto height n exc 8.5m and removing from site by contractor at his own expense complete all as directed by Engineer-in-Charge
Taking down existing bituminous felt carefully including plaster,concrete etc.of any thickness,and cleaning of surfaces of roof,terrace including junctions of parapet walls,kerb walls,PCC fillets,benching etc.with wire brushes and removing of rubbish outside Min of Defence land to any lead complete all as directed by Engineer-in-Charge.
Roughening old concrete floor / slab top surfaces by picking,sweeping clean and washing down with water to remove all loose dust,dirt,etc,and evenly applying a coat of cement slurry at the rate of 3 kg per Sqm complete all as specified and as directed by Engineer-in- Charge.
Dismantling steel rolling shutters including top cover hood of any size,pattern, weight and removing from the site by the contractor at his own expense complete all as directed by Engineer-in-Charge. (approx area of each rolling shutter is 7.5 sqm)
Dismantling floor, hearth or wall tiling including cementbmortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and removing debries outside MD land complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads including punching or drilling out old glazing pins/spring clips etc complete all as specified and directed.
Demolition of cement concrete in ground floor and paving n exc 15 cm thickness (below or above ground level) and removal of debris out of MD land complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm but n exc 4.00 sqm each and removing from the site by the contractor at his own expense complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description,n exc 2.00 sqm each and removing from site by contractor at his own expense complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning or removing from site and making good the disturbed surface for 15 mm dia pipes complete all as specified and directed.
Taking up or down steel tubing and connections including cleaning or removing from site and making good the disturbed surface for 20 mm dia pipes complete all as specified and directed.
Demolition of precast solid block walling of any description, thickness,built in cement mortar including all quoins,arches pillars etc.and similar precast articles complete all as specified and as directed
Demolition Concrete of any description and in any position not otherwise specifically provided for complete all as directed by Engineer-in Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as directed by Engineer-in Charge.
Dismantling plain or corrugated steel sheeting,any gauge,thickness,including Nainital or similar pattern roof coverings complete all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removal of debris out side MD land complete all as specified and as directed.
M&L for rendering 10mm thick in CM 1:3 on existing concrete top surfaces of roof slab or terrace etc including mixing water proofing compound @3% by weight of cement and finishing the surfaces even and fair to receive water proofing treatment complete all as specified and as directed. (Note- Water proofing compound shall measured and paid separately as supply only).
Supply only integral waterproofing compound ISI marked as approved
M&L for water proofing treatment over RCC slab/terrace by preparing newly plastered dried up surfaces of slab etc and applying a coat of oil bound bituminous primer @ 0.25 Kg/Sqm and finally laying 3mm thick APP modified water proofing membrane of weight not less than 3.50 kg per sqm reinforced with non woven polyster matt weighing not less than 160 gm/sqm polyster core,having soften point not less than 1500 degree celcius,longitudinal tensile strength 650N/5cm,laying the membrane by torch application method with suitable laps not less than 100mm on either directions including carrying out 24 hour's ponding test complete all as specified and as directed. (Note:Contractor shall give 10 years guareentee certificate for waterproofing treatment carried out)
M&L for preparing top surfaces of APP modified membrane laid on top of roof/terrace and evenly applying a coat of solar reflective bituminous aluminium paint @ 0.15 Kg/Sqm complete all as specified and as directed
S&F,steel rolling shutters,with thickness of laths 1.25mm complete with ball bearing,as specified including top cover,anchoring rod,hasp and staple and one shop coat of primer,erected in position as indicated,complete pull push or manual type all as specified and directed.
M & L for non - skid coloured joint free ceramic tiles , first quality (of approved class, colour and design/shade) 7 to 8 mm thick(Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors, etc. set and jointed in neat cement slurry and pointed in coloured cement to match with colour of tiles laid over & including 15 mm thick screed bed in cement mortar ( 1:6) etc as in flooring complete all as specified and directed.complete all as specified and directed.
M&L for vitrified coloured ceramic tiles of light shade 10mm thick,(Square/rectangular),polished,area of each tile n exc 0.36 sqm,laid in floors etc;set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tile laid over & including 15 mm thick screed bed in cement mortar ( 1:6) etc as in flooring complete all as specified and directed.complete all as specified and as directed
M&L for terrazzo tiles,25cmx25cmx22mm thick,with size of chips upto 6mm;with grey cement and pigment,laid in floors,set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile laid over & including 15 mm thick screed bed in cement mortar ( 1:6) etc as in flooring complete all as specified and directed.complete all as specified and as directed
M&L for Glazed ceramic tiles in vertical surface 450mmx350mmx 7mm or 400mmx400mmx7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with colour of tiles and including 10mm thick backing coat in cement mortar (1:4) including triangular filleting on top in cement mortar (1:4) complete all as specified and as directed.complete all as specified and directed.
M&L for vitrified coloured ceramic tiles of light shade 10mm thick,(Square/rectangular),polished,area of each tile n exc 0.36 sqm,as on vertical surfaces of walls as in dado/skirting, etc;set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tile and including 10mm thick backing coat in cement mortar (1:4) including triangular filleting on top in cement mortar (1:4) complete all as specified and as directed.complete all as specified and as directed
M&L for terrazzo tiles,25cmx25cmx22mm thick,with size of chips upto 6mm;with grey cement and pigment,as on vertical surfaces of walls such as dado/skirtng,set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile and including 10mm thick backing coat in cement mortar (1:4) including triangular filleting on top in cement mortar (1:4) complete all as specified and as directed.complete all as specified and as directed
S&F 2nd class hard wood,plain,solid,straight chowkats and frames,wrought,,framed rebated on the solid ,rounded or chamfered,put together with glue,pinned at joints,supplied and fixed to walls complete all as specified and as directed.
S&F 30mm thick flush shutters,solid core construction,with block board core covered with decorative face veneers on both sides/faces with lipping/frame to match complete supplied and fixed to chowkats all as specified and directed.
S&F 25mm thick flush shutters,solid core construction,with block board core covered with decorative face veneers on both sides/faces with lipping/frame to match complete supplied and fixed to chowkats as in cupboards all as specified and directed.
S&F solid PVC Door Frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube,and fixing in opening as per manufacturer's instructions and as directed by Engineer-in-Charge. complete all as specified and as directed.
S&F,30mm thick (style) factory made solid panel PVC door shutter consisting of frame made out of tubes for top and bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC 'C" channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail and bottom rail on either side and as gap inserts for top rail and bottom rail;Panelling of plain colour PVC sheet to be fitted in the M S frame welded/sealed to the stiles and rails with suitable PVC sheet beading,and joined together with solvent cement,supplying and fixing in the frame as per manufacturer's instructions and as directed by Engineer-in-Charge.
Supply and fixed with and including 4.00 mm thick, sheet glass,ordinary quality,plain and glazing with oil putty or glazing beads etc.in Squares n exc 0.50 sqm in each pane complete all as specified and directed.
Supply and fixed with and including 4.00 mm thick, sheet glass,ordinary quality,groung.obscured or frosted on one side and glazing with oil putty or glazing beads etc.in Squares n exc 0.50 sqm in each pane complete all as specified and directed.
S&F 100 mm size,butt hinges,medium weight,cold rolled mild steel and fixed complete all as specified and directed.
S&F 30mmm width of flap when open,continuous (Piano) hinges.mild steel,bright finish or electro-galvanised and fixed to shutters complete all as specified and as directed.
S&F, 200 mm size, aluminium anodised barrel tower bolt,of extruded sections and fixed complete all as specified and directed.
S&F,150mm size extruded aluminium alloy handles,fabricated type,anodised and fixed complete all as specified and directed.
S&F,100mm size, aluminium anodised,hasp and staple, safety type,with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed
S&F,300 mm, aluminium anodised,sliding door bolt with hasp,staple platesand and fixing clips of sheet,cast or extruded section,and fixing bolts and sliding bolts,of extruded sections or cast aluminioum alloy and fixed complete all as specified and as directed.
M&L for hardcore of broken stones or boulders of gauge n exc 63mm,deposited,spread,and levelled in layers n exc 15 cm thick,watered,rolled/rammed to true surface complete all as specified and as directed.
Spreading,levelling,well ramming including watering the approved soil in floors/pavings or filling under plinth protection etc for raising height complete all as required at site and as directed.(Note: Soil/earth required for filling shall be obtained from relevant excavation item here-in-after given below).
M&L for providing 75 mm thick,plain cement concrete 1:3:6,type C-1 (using 20 mm graded stone aggregates) as in plinth protection and making 10 mm wide joints filled with hot mix of bitumen and sand (1:2) complete including finishing the concrete topsurfaces even and smooth without using extra cement all as specified and as directed.
S&F in repairs,wash down water closet pan(pedestal pattern)white(excluding bolts,flushing cistern and flush pipe),but including supplying and fixing plastic water closet seat,black,closed pattern with flat bottom,and cover and mild steel chromium plated or aluminised hinging device and connecting to drain(or outgoing pipe),and to flushing pipe,antisyphonage pipe,etc. complete all as directed by Engineer-in-Charge.
S&F in repairs, 10 litres capacity, PVC,valveless, syphonic action type,flushing cistern low level,white, with inlet,ball valve,float and handle complete fixed to wall including brackets and making joint of flush pipe with water closet complete all as directed by Engineer-in-Charge.
S&F in repairs, 10 litres capacity,PVC,auto flushing type cistern for urinals etc.,valveless,syphonic action type,flushing cistern, low level,white, with inlet,ball valve,float and handle complete fixed to wall including brackets and making joint of flush pipe with water closet complete all as directed by Engineer-in-Charge.
S&F in repairs, 5 litres capacity,PVC,auto flushing type cistern for urinals etc.,valveless,syphonic action type,flushing cistern, low level,white, with inlet,ball valve,float and handle complete fixed to wall including brackets and making joint of flush pipe with water closet complete all as directed by Engineer-in-Charge.
S&F in repair,75mm bore, cast iron floor traps,with grating including jointing to waste pipe fixed in cement concrete 1:2:4 typr B1 complete all as specified and as directed.
S&F in repairs wash hand basin vitreous china white (flat back) of size 550x400mm including , CI bracket, 15mm dia polythene connection ,including 32mm dia waste coupling,chromium plated for glazed ware sinks,basins,etc.with long screwed shanks and fly nuts,flange end bedded in red lead cement and other end fixed and 32 mm bore,brass,chromium plated bottle trap for wash basin with inlet and outlet screwed for iron pipe or connections including necessary packing,union and cap chain and plug waste filling union and 32mm dia PVC waste pipe 90cm long etc. complete all as specified, and all necessary inlet outlet connections complete all as specified and directed.
S & F PVC connections 15 mm dia with brass nut on both ends and washers 450 mm long and fixed complete all as specified and directed.
S&F in repairs, Pillar taps, cast copper alloy, fancy type, with round heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs,bib taps suitable for 15mm bore of pipe, cast copper alloy,brass,chromium plated,with round knob type handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & as directed.
S&F in repair,Stop valves suitable for 15mm bore of pipe, cast cooper alloy,brass,chromium plated,fancy type,screwed down,high pressure,with round handle knob ,screwed both ends to iron pipe or for unions and fixed all as & directed.
S&F towel rail 600mm long of PTMT fixed with and including chromium pated brass screws and wooden/plastic cleats (min wt 190gms) complete all as specified and directed.
S&F in repairs,stainless steel peg set of six,of standard size trade pattern item,for hanging purpose including fixing to wall with plastic or wooden rowel plugs using suitable size of screws complete all as specified and as directed.
S&F,in repair 20mm bore dia, gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F 15mm bore GI tubing ISI marked of size 'medium grade' with and including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in floors /wall/ceiling and including clips, wall hooks etc, complete all as specified and directed
S&F 20mm bore GI tubing ISI marked of size 'medium grade' with and including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc laid in floors /wall/ceiling and including clips, wall hooks etc, complete all as specified and directed
S&F in repairs,100 mm size brass,chromium plated shower rose,with or without swievel joints and fixed to steel pipe or union all as directed.
M&L for toilet fittings brass chromium plated for Health faucet brass body with wall hook and 1 metre ss braided rubber hose pipe complete all as specified & directed. Make: Make -Cera Cat No. Cat No. F8030301 or equivalent model in Marc/ ESS-ESS as approved by GE.
S&F PVC (SWR)pipes,110mm bore,single socketed,in any length with rubber ring joints,fixed to walls with necessry clips complete fixed in repair all as specified and as directed.
S&F PVC (SWR)pipes,110mm bore,single socketed,in any length with rubber ring joints,laid in trenches complete fixed in repair all as specified and as directed.
S&F PVC (SWR)pipes,75mm bore,single socketed,in any length with rubber ring joints,fixed to walls with necessry clips complete fixed in repair all as specified and as directed.
S&F PVC (SWR)pipes,75mm bore,single socketed,in any length with rubber ring joints,laid in trenches complete fixed in repair all as specified and as directed.
S&F PVC (SWR)bends,any radius,110mm bore,with access door complete all as specified and as directed.
S&F PVC (SWR)bends,any radius,110mm bore, complete all as specified and as directed.
S&F PVC (SWR)branch piece,single (single:Y'),equal or unequal, 110mm bore,with oval access door complete all as specified and as directed.
S&F PVC (SWR)branch piece,single (single:Y'),equal or unequal, 110mm bore, complete all as specified and as directed.
S&F PVC (SWR)bends,any radius,75mm bore,with access door complete all as specified and as directed.
S&F PVC (SWR)bends,any radius,75mm bore, complete all as specified and as directed.
S&F PVC (SWR)branch piece,single (single:Y'),equal or unequal, 75mm bore with oval access door complete all as specified and as directed.
S&F PVC (SWR)branch piece,single (single:Y'),equal or unequal, 75mm bore, complete all as specified and as directed.
S&F, PVC (SWR) cowl,75mm bore and fixed complete all as specified and as directed
Excavating in trenches,n exc 1.5m wide and n exc 1.5m in depth;for foundation,etc.or for shaft,wells, cesspits, manholes, pierholes,etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed
M&L for providing PCC 1:4:8 type D 2 (using 40mm graded stone aggregates)as in foundations,filling and mass concrete complete all as specified and directed.
M&L for brick work with sub class old size"B' bricks,straight or curved on plan,exc 6mtr mean radius built in CM 1:6 complete all as specified and directed.
M&L for block masonry with solid blocks of precast cement concrete class designation C-5 (using 20mm graded stone aggregate), exc 10cm in width and setting in cement mortar (1:6) complete all as specified and as directed.
M&L for providing plain cement concrete 1:3:6,type C-2 as in concrete bedding to drain pipes of 150mm bore including packing under,and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M&L for 150mm bore reinforced concrete pipes,Class NP-2,laid and jointed complete with collars and laid in trenches or floors all as specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:4 on faces of brick work or concrete surfaces including finishing even and smooth without using extra cement complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:3 on faces of brick work orconcrete surfaces including finishing even and smooth with using extra cement and shall be mixed with water proofing compound (WPC) at the rate of 3% by weight of cement complete all as specified and as directed. (WPC shall be measured and paid seperately as supply only.)
M&L for 15mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces including finishing surfaces even and smooth without using extra cement complete all as specified & as directed.
M&L for providing precast reinforced cement concrete 1:2:4, type B1 as in landings,cover slabs for manholes etc.chullah hoods,chajjas,water troughs,mangers,shelves and similsr articles with plain faces complete set in CM (1:4)all as specified and as directed. (Note- Reinforcement shall be measured and paid separately under relevant item here-in-before above).
M&L for mild steel TMT bars 6 to 8mm dia cut to length, bent to shape required,including cranking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire annealed not less than 0.90mm dia or securing with clips complete all as specified and directed.
M&L for providing plain cement concrete 1:2:4, type B1 as in lintels upto 1.5m span,cills,steps;seismic and other similar bands,plinth courses,string courses,parapets and railings upto 60cm in height,copings ,haunchings,bottom benching of manholes,etc. and the like including weathering,slightly rounded or chamfered angles and throating complete including necessry formwork all as specified and as directed.
Extra for forming fair finished drain or channel 75 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and directed.
Extra for forming fair finished drain or channel 52cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and directed.
Returning,filling in,including spreading,levelling,watering and well ramming the earth in layers not exc 25 cm in any type of soil complete all as specified and as directed.
Removing excavated surplus materials such as soil/spoil etc n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
S&F,pre-painted galvalume aluminium zinc coating GI based corriugated steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering or cladding to wall,fixed with self tapping screws complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering or cladding to wall,fixed with self tapping screws complete all as specified and as directed.
M&L for complete removal of existing treatment on walls,pillars etc.and applying a thin coat of 3 mm thick wall care putty on the same and finishing the prepared surfaces by applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for complete removal of existing treatment on walls,pillars etc.and applying a thin coat of 3 mm thick wall care putty on the same and finishing the prepared surfaces by applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls,pillars etc.and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls,pillars etc.and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description,not otherwise described,over 10 cm width or girth and evenly applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of old painted wood and wood based surfaces of any description,not otherwise described,over 10 cm width or girth and evenly applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted steel and iron surfaces of any description,not otherwise described,over 10 cm width or girth and evenly applying two coats of synthetic enamel paint complete all as specified and as directed.
M&L for preparing new steel and iron surfaces of any description exc 10cm in width or girth,not otherwise described,and evenly applying two coats of aluminium paint over a coat of aluminium red oxide paint primer complete all as specified and as directed.
M&L for preparing old steel and iron surfaces of any description exc 10cm in width or girth,not otherwise described,and evenly applying two coats of aluminium paint complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:4 on faces of brick work or concrete surfaces mixed with WPC @ 3% by weight of cement including finishing even and smooth without using extra cement complete all as specified and as directed. (WPC shall be measured and paid separately as supply only).
M&L for construction of septic tank 100 users capacity with including excavation and earthwork in any type of soil, PCC 1:2:4 as in bottom slab/foundation concrete and coping/benching precast solid block walling in CM (1:6),RCC 1:2:4 in top slab,15mm thick CM 1:3 plaster using WPC @3% by weight of cement,PVC pipes and fittings in vent pipes,Precast RCC covers for manholes in 1:2:4 set in CM (1:4) complete all as specified and shown on Drawing No- CEPZ/92/TD/17M Sht1/2&2/2.
Supply and fix in repair 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) double layered 'ISI' marked, hoisted & fixed in position including /25mm dia ball brass valve with polythene flaot and flynut, with existing inlet, outlets & provision of washouts, vent pipe, nipples of suitable size complete all as specified & directed.
M&L for machine cut cudappah stone slab 20-25 mm thick over cement screed base,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab as in partitions for urinals etc. including rubbing and polishing complete all as specified and as directed.
M&L for rounding to edges of stone slabs one edge such as in steps,cooking platform and other similar situations complete all as directed.
S&F in repairs,vitreous china urinals,half stall type (back or corner wall type),complete including and providing and fixing plugs,bedding urinalagainst wall in cement mortar (1:2),securing urinals to plugs with and including 60 mm long brass screws,pointing around urinal back in cement;fixing 10 ltr capacity flushing cistern with brackets,flushing pipe, grating and union for discharge pipe (excluding of fixing supply pipe to flushing cistern,trap and waste pipe complete all as directed.
S&F,40mm dia galvanised steel (GI) tubing, medium grade, with all fittings and fixed to walls and ceiling or laid in floors as in waste water pipes for urinals etc.complete all as specified & directed.
M&L for preparation o fold plastered decorated surfaces of walls,pillars etc.and applying two coats of white(lime)wash complete all as specified and as directed.
M&L for preparation of old plastered decorated surfaces of ceiling,soffits etc.and applying two coats of white(lime)wash complete all as specified and as directed.
M&L for Armstrong make ceiling using 9mm thick gypsum based ceiling tiles with wheather resistance face on back side and vinyl finish on the front fixed in 24 mm GI Armstrong frame work of grid 600x600 mm size, the members of snap grid frame work of GI/Steel section of 24mm wide with T-flanges, channels etc of white colour having rotary stiching on all members, i.e main runner, 1200x600mm,cross tee galvanised with minimum thickness of 120 gms per/sqm passed through 500 hrs test and hanging the same with existing roof members such as rafters, pulins or other wooden members particularly provided for hanging pupose using 8mm dia mild steel bar or 6mm dia GI wire of required length fixed with nut bolt of 50mm long and 10mm dia of neck with washer,flat iron 50x6mm thick clamps etc to wooden members all as specified and directed. (Note : an addl wooden members required for hanging of ceiling shall be measured and paid under relevant item here in before above separately).
S&F,anodised aluminium frame for doors,windows, ventilators with one or more rebate including joining cleat for fixing etc.complete all as specified and as directed.
S&F,anodised aluminium window and ventilator shutters,fixed type without sash bar,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber packing, aluminium snap beading, screws,etc complete all as specified and as directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on same board with other switches incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket all as specified and directed.
M & L for sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
S&F 5 Amp switch piano type single pole one way incl dismentling taking down unsv one all as specified and as directed.
S&F socket flush type 6 amps, 5 pin, 230v incl dismentling taking down unsv one all as specified and as directed.
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v incl dismentling taking down unsv one all as specified and as directed
S&F lamp Holder insulated body with back plate for batten fitting incl dismentling taking down unsv one all as specified and as directed.
S&F LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL. all as specified and as directed. Make-HPL/Havells/CG/Bajaj/ Philips as approved by GE
S&F ceiling rose surface Bakelite three terminal incl dismentling taking down unsv one all as specified and as directed.
S&F flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz incl dismentling taking down unsv one all as specified and as directed.
S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4085-87 to 4085-95 of Legrand or equivalent of Schneider/ABB as approved by GE
S&F MCB, DP 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4086-28 to 4086-36 of Legrand or equivalent of Schneider/ABB as approved by GE
S&F MCB, Four Pole 16 KA,c curve, 40 to 63 amps, 415 Volts incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4087-92 to 4087-94 of Legrand or equivalent of Schneider/ABB as approved by GE
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 6077 11 of Legrand or equivalent of Schneider/ABB as approved by GE
S&F Vertical MCB distribution board, as MCCB incomer, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5077 45 of Legrand or equivalent of Schneider/ABB as approved by GE
S&F PVC rectangular switch board of size 300mmx 250mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismentling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza as approved by GE
S&F Hylam Sheet 3mm thick on existing concealled MS/CI ractangular or Squar or round box with 04 nos cadmium coated screws and cup washer incl cutting slots for mounting switch/socket/fan regulator/ batten holder etc incl dismentling taking down unsv one
S&F Circular LED Highbay with tapered fin design and excellent thermal management along with IP 66 protectiont reliable suitable for ceiling (surface/ suspended ) complete all as specified and as directed. Make:- CG Model No LHB11-140-CL/60 or equivalent Philips, Havells and Bajaj as approved by GE
S&F square shaped recess mounted Led pannel with drop down acrylic diffuser and suitable for fixing to POP ceiling with necessary clamps 40 watt CDL 2X2 feet size complete all as specified and as directed. Make :-CG cat part no.LCTLRN-36-FO-CDL (ORION -II ) as approved by GE
S&F Building security light 15 watt 230 volt complete with all accessories and including connecting up to ceiling rose with 0.5 sq mm 3 core copper flexible conductor cable ,one GI light grade 20 mm dia bracket of total length 50 cm and fixed to wall with 2 nos ms clamp and fastener including taking down defective light fitting . Make:- CG, Cat Part No LSTS-18-CDL or equivalent of Baja/ philips/Havells as approved by GE.
S&F industrial box type LED Batten with CRCA body, pre coated with white and prewired suitable for LED tube 1x18/20 watt 4'long all as specified and directed. Make-CG, Cat Part No-IGP131LT8-16 or equivelent of Bajaj/Philips/HPL/Havells as approved by GE
S&F Retro LED tube 20 watt suitable for LED Batten fitting surface mounted all as specified and directed. Make-Cat Part No LT8-20-865-2 of Crompton Greaves or equivalemt in Bajaj/Philips/HPL/Havells as approved by GE
Supply and fix in repair of ceiling fan (with and including assembling the same) 5 star rating with hook 1200 mm (48") sweep and connecitng up complete with and including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to porcelain connector block of fan suitable on working AC, SP 230 V electric supply including electronic fan regulator stepped, flush type including all connection and taking down defective ceiling fan of any sweep and depositting to MES store yard,complete all as specified and directed.
M&L Air circulator fan 600 mm Heavy duty fixed on wall complete all as directed at site Make CG/Bajaj/Usha as approved by GE
S&F exhaust fan, single phase, PVC frame 450 mm sweep, including fixing of mounting frame in the round hole cutitng in the wall by means of rugged bolts, nuts and washers etc including three core copper conductor flexible cord of 0.5 sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of exhaust fan including taking down old and deposited to E & M store yard complete all as specified and directed.
Supply and fixing MCCB, 3 pole, 25 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal magnetic release, 125 amps suitabe for Vetrical TPN DB MCCB incomer, incl dismentling taking down unsv one complete all as specified and directed. Make- Legrand Cat or equivelent model of Schneider/ ABB/Merlin Gerin as approved by GE.
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanised steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wiremesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
SAMBHAJI D JARANDE
S.R.M.K Enterprises
M/S JAYCONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .