Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC M S PLOT NO 2273 M S KHATA NO 305 1289 AT RAMPUR COLLIERY PO BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768225 | JHARSUGUDA | ODISHA | 768225 | L1 | Accepted-AOC The amount quoted by L1 bidder R.R. Electrical is 35.70 percent below the estimated cost / the updated cost. | |
| 2 | L2₹5.9 L+₹73,584.36 (14.3%)Rejected-Finance AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L2 | Rejected-Finance On being L2 | |
| 3 | L3₹6.1 L+₹99,190.05 (19.3%)Rejected-Finance AT FCI LAXMI BAZAR TALCHER PO VIKRAMPUR DIST ANGUL ODISHA 759117 | TALCHER | ANGUL | ODISHA | 759117 | L3 | Rejected-Finance On being L3 | |
| 4 | L4₹6.2 L+₹1.1 L (20.6%)Rejected-Finance KAMALA BIHAR BAGHUABOL PO HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | L4 | Rejected-Finance On being L4 | |
| 5 | L5₹6.5 L+₹1.3 L (26.0%)Rejected-Finance AT GANDHI CHOWK BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L5 | Rejected-Finance On being L5 |
Tender Value
₹8.0 L
EMD Value
₹10,000
Closing Date
15 Mar 2024, 5:00 pmClosed
Vijay Kumar Staff Officer(EnM) Lakhanpur Area
Vijay Kumar Staff Officer(EnM) Lakhanpur Area GM Office Bandhabahal Dist-Jharsuguda Odisha-768211 Mob-9437595715
Complete wiring of all rooms including main power supply arrangement and incoming panel of LKPA Dispensary at BIT Colony,Lakhanpur Area
2024_MCL_303618_1
MCL/LKPA/EnM/eNIT/23-24/121 dt-04.03.2024
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
BIT Colony, Lakhanpur Area
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
26 Apr 2024
4 Mar 2024
18 Mar 2024
4 Mar 2024
15 Mar 2024
5 Mar 2024
4 Mar 2024 - 8 Mar 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.-Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required-2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required-2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required-2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required-2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required.-5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required.-3 pin 5/6 A socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.-Bell push
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)-12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.-double pole
Supplying of BLDC ceiling fan-28W, 1200 mm sweep , 230 volts, with double ball bearing copper winding with energy efficient / saving decorative type, smooth sound complete set as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying of 300 mm mettalic ventilating Fan, 1200rpm, shutter type , 5 star rating energy saving complete set as required
Supplying of 15 Watt LED Bulb
Supplying of 18 Watt LED Tube Light
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying, installing, testing and commissioning of following capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. as required.-200 A TPN
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/S LIGHT PALACE
M/S J.N.RAY
M/s. Sahida Electrical Works
M/S H.A. ENTERPRISES
BHABANI SANKAR PRADHAN
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .