Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹34.2 L+₹2.6 L (8.40%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹34.9 L+₹3.3 L (10.6%)Rejected-Finance 26 740 35 KESARI HOUSE NEAR RICO INDUSTRIAL AREA DEVIPURA SIKAR RAJASTHAN 332 001 | SIKAR | SIKAR | RAJASTHAN | 332001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹37.8 L+₹6.3 L (19.9%)Rejected-Finance 2ND FLOOR PAPPOOTTY COMPLEX VAZHAKULAM MUVATTUPUZHA KERALA 686670 | MUVATTUPUZHA | ERNAKULAM | KERALA | 686670 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹38.5 L+₹7.0 L (22.2%)Rejected-Finance 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L5 | Rejected-Finance Being L5 |
Tender Value
₹43.3 L
EMD Value
₹86,600
Closing Date
18 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER NAVY LKD
Military Engineer Services GE Navy Lakshadweep Coast Guard Road Kavaratti Islands
AUGMENTATION OF ELECTRICAL DISTRIBUTION PANELS AND POWER SUPPLY DISTRIBUTION SYSTEM UNDER AGE E M KAVARATTI, GE NAVY LAKSHADWEEP
2023_MES_633607_1
8379/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GARRISON ENGINEER NAVY LAKSHADWEEP
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER NAVY LAKSHADWEEP
₹86,600
Yes
28 Feb 2024
20 Dec 2023
20 Jan 2024
20 Dec 2023
18 Jan 2024
4 Jan 2024
20 Dec 2023 - 25 Dec 2023
Amount
Supply and laying, connecting and commissioning of 10 sqmm 4 core LT under ground cable 1100 volts grade XLPE insulated armoured heavy duty electric cables with aluminium conductor including connecting with suitable size of cable glands lugs etc laid in trenches or fixed on walls complete all as specified and as directed by Engineer-in-Charge.
Supply and laying, connecting and commissioning of 16 sqmm 4 core LT under ground cable 1100 volts grade XLPE insulated armoured heavy duty electric cables with aluminium conductor including connecting with suitable size of cable glands lugs etc laid in trenches or fixed on walls complete all as specified and as directed by Engineer-in-Charge.
Supply and laying, connecting and commissioning of 25 sqmm 4 core LT under ground cable 1100 volts grade XLPE insulated armoured heavy duty electric cables with aluminium conductor including connecting with suitable size of cable glands lugs etc laid in trenches or fixed on walls complete all as specified and as directed by Engineer-in-Charge.
Supply and laying, connecting and commissioning of 70 sqmm 3.5 core LT under ground cable 1100 volts grade XLPE insulated armoured heavy duty electric cables with aluminium conductor including connecting with suitable size of cable glands lugs etc laid in trenches or fixed on walls complete all as specified and as directed by Engineer-in-Charge.
Supply and laying, connecting and commissioning of 95 sqmm 3.5 core LT under ground cable 1100 volts grade XLPE insulated armoured heavy duty electric cables with aluminium conductor including connecting with suitable size of cable glands lugs etc laid in trenches or fixed on walls complete all as specified and as directed by Engineer-in-Charge.
Supply and laying, connecting and commissioning of 120 sqmm 3.5 core LT under ground cable 1100 volts grade XLPE insulated armoured heavy duty electric cables with aluminium conductor including connecting with suitable size of cable glands lugs etc laid in trenches or fixed on walls complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of cable and getting out in any type of soil complete all as specified and directed by Engr-in-Charge .
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as directed by Engr-in-Charge
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Material and labour for sand cushioning with Sand in two layer,first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts for cable including consolidation of each layer complete all as specified.Note:Thickness of sand cusioning shall be measured after punning complete all as specified and directed by Engineer-in-charge.
supply and Laying unreinforced precast concrete cable cover class LV 1 flat size of size 250x150x40 mm for LT Cable all sizes complete all as specified and directed by Engineer-in-charge.
Material and labour for cutting the existing hardstanding not less than 25cm in deep and 45cm in width for laying of underground cable through GI pipe and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.
Supply and fix GI tubing 50 mm dia light grade ISI marked laid in trenches complete with all accessories such as Tees union , bend ,elbow nipple reducer etc as required for protection of UG Cable on floor ,Pole etc complete all as specified and directed by Engineer-in-charge.
Supply and fix GI tubing 80 mm dia light grade ISI marked laid in trenches complete with all accessories such as Tees union , bend ,elbow nipple reducer etc as required for protection of UG Cable on floor ,Pole etc complete all as specified and directed by Engineer-in-charge.
Panel No 1 : Supply & Install, test and commission factory made outdoor type thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of size (1100x1885x600mm) with 400 Amps rated copper busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer , LT feeder pillar box shall be manufactured by CPRI approved manufacturer , including PCC foundation to accmoomodate and comprising of following:- (i) MCCB 4 Pole, 415V 250 Amps, 36kA-01 (incoming) (ii) MCCB 4 pole, 415V 160 Amps 36kA - 04 & 63 Amps 25 KA -02 (outgoing) (iii) MCB TPN 32 Amps 10 KA - 2 Nos. (iv) Digital voltmeter 0-500 V 01 No (v) Digital ammeter with Cts 250 amps- 01 No (vi) Tamper proof digital KWH enery meter with CTs - 01 No (vii) Indicator lamp LED type 240V AC (RYB) - 01 set
Panel No 2 : Supply & Install, test and commission factory made outdoor type/Floor mounted thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of size (800x1135x 600mm) with 125 Amps rated copper busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer , LT feeder pillar box shall be manufactured by CPRI approved manufacturer, including PCC foundation to accmoomodate and comprising of following:- (i) MCCB TPN 415V 63 Amps 25 kA-01 (incoming) (ii) MCB TPN 32Amps 10 kA - 02 Nos. (outgoing) (iii) MCB SPN 32 Amps 10 KA - 1 Nos and MCB SP 6-32 Amps 10 KA - 2 Nos (iv) Digital voltmeter 0-500 V 01 No (v) Digital ammeter with Cts 250 amps- 01 No (vi) Indicator lamp LED type 240V AC (RYB) - 01 set (vii) DOL starter for Pump
Panel No 3 : Supply & Install, test and commission factory made outdoor type/Floor mounted thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of size (1400x1735x 600mm) with 400 Amps rated copper busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer , LT feeder pillar box shall be manufactured by CPRI approved manufacturer , including PCC foundation to accmoomodate and comprising of following:- (i) MCCB 4 Pole, 415V 250 Amps, 36kA-01 (incoming) (ii) MCCB 4 pole, 415V 160 Amps 36kA - 02 & 125 Amps 25 KA -02 (outgoing) (iii) Digital voltmeter 0-500 V 01 No (iv) Digital ammeter with Cts 250 amps- 01 No (v) Tamper proof digital KWH enery meter with CTs - 01 No (vi) Indicator lamp LED type 240V AC (RYB) - 01 set
Panel No 4 : Supply & Install, test and commission factory made outdoor type thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of size (1100x1285x600 mm) with 200 Amps rated copper busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer , LT feeder pillar box shall be manufactured by CPRI approved manufacturer , including PCC foundation to accmoomodate and comprising of following:- (i) On Load change over switch TPN 4 pole 415V 100 Amps, 16kA-01 (incoming) (ii) MCCB 4 pole, 415V 100 Amps 25 kA - 01 (outgoing) (iii) MCCB 4 pole 63 Amps 25 KA - 1 Nos. (iv) MCB SPN 32 Amps 10 KA - 1 Nos and MCB SP 6-32 Amps 10 KA - 2 Nos (v) Digital voltmeter 0-500 V - 01 No (vi) Digital ammeter with Cts 250 amps- 01 No (vii) Indicator lamp LED type 240V AC (RYB) - 01 set
Panel No 5 : Supply & Install, test and commission factory made outdoor type thermoplastic polycarbonate cubical type feeder pillar box IP 65 protection suitable for 3 phase 4 wire 415 V, 50 Hz of size (800x1285x600mm) with 125 Amps rated copper busbar, internal wiring connection with suitable size copper cables and MS angle iron based frame painted with two coats of synthetic enamel paint over a coat of red oxide primer , LT feeder pillar box shall be manufactured by CPRI approved manufacturer , including PCC foundation to accmoomodate and comprising of following:- (i) MCCB 4 pole 415V 63 Amps, 25 kA-01 (incoming) (ii) MCCB 4 pole, 415V 63 Amps 25 kA - 01 (outgoing) (iii) MCCB 4 pole 40 Amps 16 KA - 1 Nos. (iv) MCB SPN 32 Amps 10 KA - 1 Nos and MCB SP 6-32 Amps 10 KA - 2 Nos (v) Digital voltmeter 0-500 V 01 No (vi) Digital ammeter with Cts 250 amps- 01 No (vii) Indicator lamp LED type 240V AC (RYB) - 01 set
Supply and fix Distribution board VTPN 6 way Vertical type double door 415 Volts as per IP-43 with provision for 125 Amps MCCB as incomer and SP/SPN/TPN MCB as outgoing and electrically connected up complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 4 pole 415V 125 Amps 16 kA complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB TPN/FP 415V 63 Amps 10 kA complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB SPN 32 Amps 10 KA 240 V complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB SP 6 - 32 Amps 10 KA 240 V complete all as specified and as directed by Engineer-in-Charge.
Earthing complete with galvanized iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the Galvanised iron earth lead 32x6 mm size, by means nut, bolt, check nuts and washer of galvanized iron and 32x6 mm as earth lead protected by provision of GI light grade pipe 40mm bore incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced (weight not less than 4Kg/Sqm) and frame of angle iron 25x25x6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangement CI funnel wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exc 50 mtr all as per electrical plate No.3 of SSR Part I and connecting to earth test point all as specified incl testing on completion.
Supply and fix cable path indicator for LT cable made out of cast iron plate of 100 mm dia, 6 mm thick engraved with "LT 1100 volts" welded to MS angle 50x50x6mm, 75 cm long embedded in PCC block (1:3:6) type C-2 of size 30x30x30cm including painting with two coats of blue colour synthetic enamel paint over one coat of red oxide primer and necessary earth work complete all as specified and as directed.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-charge.
Supply and fix FRP ( Fiber Reinforced Polymer composite) pole conical embeded type 6 mtr long along with 1000mm single arm FRP bracket including necessary foundation and fixing arrangements complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-charge.
M/s PATEL ENGINEERING
HUMERS INFRATECH
Linsta Services
Jack Electrolinks Private Limited
STANDARD ENGINEERING
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .