| Sl No | Description | Qty | Unit | M/S BALWINDER SINGH L3 | TARA ENTERPRISES L2 | R. P. Suppliers and Construction Co. L1 | Northern cable fault locatoers L4 | Fabtech Engineering L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Servicing & maintenance of DG sets as per manufacturer's maintenance reference to the entire satisfaction of Engineer-in-Charge of the under mentioned parts for the following capacity :- (i) Draining out engine/lubrication oil, flushing and pouring new engine oil to DG set including supply and replacement of oil pan/chamber gasket (ii) Supply and fix, primary and secondary fuel filter element Make Bosh complete with gasket/rubber ring, in replacement as per existing sample. (iii) General servicing of DG set by opening of tappet cover/top cover, tappet clearance setting with injector timming adjustment, re-fixing of tappet/top cover including supply and replacement of tappet cover packing set, fixed with shellac/bostic tube. (iv) Tightening of all electrical connections, AVR connections, alternator connections and panel connections (v) Tightening of all the hoses, fuel connections. (vi) Opening of Battery terminals negative and positive,cleaning of posts negative and positive of battery with ambri paper/regmaar,applying petrolium jelly over the posts,refixing the battery terminals properly. (vii) Filling of coolant to radiator as per required level (viii) Testing of Engine on load for 30 Minutes own cost of contractor. | ||||||||
| 1.01 | 20 KVA to 40 KVA | 10 | Each Job | 3,000 ₹30,000 | 2,500 ₹25,000 | 1,500 ₹15,000 Lowest | 2,000 ₹20,000 | 2,178 ₹21,780 |
| 1.02 | 62.5 KVA to 82.5 KVA | 4 | Each Job | 3,500 ₹14,000 | 2,500 ₹10,000 | 3,000 ₹12,000 | 2,200 ₹8,800 Lowest | 2,458 ₹9,832 |
| 1.03 | 100 KVA to 140 KVA | 7 | Each Job | 4,000 ₹28,000 | 3,000 ₹21,000 | 3,000 ₹21,000 | 2,500 ₹17,500 Lowest | 2,895 ₹20,265 |
| 1.04 | 160 KVA to 200 KVA | 5 | Each Job | 4,500 ₹22,500 | 3,500 ₹17,500 | 3,000 ₹15,000 Lowest | 3,000 ₹15,000 Lowest | 3,058 ₹15,290 |
| 1.05 | 320 KVA to 400 KVA | 3 | Each Job | 5,500 ₹16,500 | 4,500 ₹13,500 | 5,000 ₹15,000 | 4,000 ₹12,000 | 3,745 ₹11,235 Lowest |
| 2.00Repair / Overhauling of DG set Removing tappet cover and cylinder heads gaskets from DG set, Grinding and polishing of cylinder heads, grinding of valve seats, grinding of inlet and exhaust valve after fixing new seals, calibration of injector, refitting cylinder head and tappets cover, changing of oil and replacement of the under mentioned parts for the following capacity :- (i) Bearing in fan body (ii) Inlet and exhaust valve pair (iii) Valve sheet insert (iv) Inlet and exhaust valve guide (v) Cylinder liner with joint ring (vi) Gasket for head (vii) Gear oil seal (viii) Oil seal all (ix) Thermostate element (x) Hose set (xi) Lub oil Pressure gauge (xii) Flexible pipe (xiii) Starter ring (xiv) Water Pump assy (xv) radiator pipe (xvi) Fuel Pipe (xvii) Branded wrapped belt (xviii) Testing the DG sets on load | ||||||||
| 2.01 | 20 KVA to 40 KVA | 3 | Each Job | 37,000 ₹1,11,000 | 40,000 ₹1,20,000 | 4,000 ₹12,000 Lowest | 50,000 ₹1,50,000 | 40,000 ₹1,20,000 |
| 2.02 | 62.5 KVA to 82.5 KVA | 2 | Each Job | 47,000 ₹94,000 | 60,000 ₹1,20,000 | 5,000 ₹10,000 Lowest | 55,000 ₹1,10,000 | 45,000 ₹90,000 |
| 2.03 | 100 KVA to 140 KVA | 3 | Each Job | 62,000 ₹1,86,000 | 70,000 ₹2,10,000 | 6,000 ₹18,000 Lowest | 75,000 ₹2,25,000 | 55,000 ₹1,65,000 |
Tender Value
Refer Docs
EMD Value
₹89,880
Closing Date
18 Jul 2025, 6:00 pmClosed
Sachin Kumar IDSE EE GE AF Adampur
Military Engineer Services AF Stn Adampur 144103
REPAIR/MAINTENANCE OF DG SETS AND CONNECTED WORKS AT AF STN ADAMPUR
2025_MES_715939_1
GE(AF)/ADM/T-47 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Under GE AF Adampur
As per NIT Documents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹89,880
Yes
30 Aug 2025
20 Jun 2025
19 Jul 2025
21 Jun 2025
18 Jul 2025
5 Jul 2025
21 Jun 2025 - 4 Jul 2025
Amount
Servicing & maintenance of DG sets as per manufacturer's maintenance reference to the entire satisfaction of Engineer-in-Charge of the under mentioned parts for the following capacity :- (i) Draining out engine/lubrication oil, flushing and pouring new engine oil to DG set including supply and replacement of oil pan/chamber gasket (ii) Supply and fix, primary and secondary fuel filter element Make Bosh complete with gasket/rubber ring, in replacement as per existing sample. (iii) General servicing of DG set by opening of tappet cover/top cover, tappet clearance setting with injector timming adjustment, re-fixing of tappet/top cover including supply and replacement of tappet cover packing set, fixed with shellac/bostic tube. (iv) Tightening of all electrical connections, AVR connections, alternator connections and panel connections (v) Tightening of all the hoses, fuel connections. (vi) Opening of Battery terminals negative and positive,cleaning of posts negative and positive of battery with ambri paper/regmaar,applying petrolium jelly over the posts,refixing the battery terminals properly. (vii) Filling of coolant to radiator as per required level (viii) Testing of Engine on load for 30 Minutes own cost of contractor.
20 KVA to 40 KVA
62.5 KVA to 82.5 KVA
100 KVA to 140 KVA
160 KVA to 200 KVA
320 KVA to 400 KVA
Repair / Overhauling of DG set Removing tappet cover and cylinder heads gaskets from DG set, Grinding and polishing of cylinder heads, grinding of valve seats, grinding of inlet and exhaust valve after fixing new seals, calibration of injector, refitting cylinder head and tappets cover, changing of oil and replacement of the under mentioned parts for the following capacity :- (i) Bearing in fan body (ii) Inlet and exhaust valve pair (iii) Valve sheet insert (iv) Inlet and exhaust valve guide (v) Cylinder liner with joint ring (vi) Gasket for head (vii) Gear oil seal (viii) Oil seal all (ix) Thermostate element (x) Hose set (xi) Lub oil Pressure gauge (xii) Flexible pipe (xiii) Starter ring (xiv) Water Pump assy (xv) radiator pipe (xvi) Fuel Pipe (xvii) Branded wrapped belt (xviii) Testing the DG sets on load
20 KVA to 40 KVA
62.5 KVA to 82.5 KVA
100 KVA to 140 KVA
160 KVA to 200 KVA
200 KVA to 400 KVA
Repairing, decarburizing manifolds exhaust system and connected items DG sets including replacement of unserviceable asbestos rope on exhaust muffler/silencer including necessary nuts, bolts & washer etc with necessary masonry work as required for the following capacity :-
20 KVA to 40 KVA
62.5 KVA to 82.5 KVA
100 KVA to 140 KVA
160 KVA to 200 KVA
320 KVA to 400 KVA
Repairing, cleaning/servicing of radiator assembly DG sets including descaling of tubes with solution, chemicals and compressed air blast including soldering/gas welding of leaking tubes including cutting welding of rusted MS tubes with new tubes, making it leak proof, & re-fixing after testing, for the following capacity :-
20 KVA to 40 KVA
62.5 KVA to 82.5 KVA
100 KVA to 140 KVA
160 KVA to 200 KVA
320 KVA to 400 KVA
Calibration of fuel injector assembly at authorize workshop including replacement of cup, barrel and plunger injector washer etc, and re-fixing to its original position including necessary Service as required, including transportation to workshop and back for the following capacity :-
20 KVA to 40 KVA
62.5 KVA to 82.5 KVA
100 KVA to 140 KVA
160 KVA to 200 KVA
320 KVA to 400 KVA
S&F, Rubber hose pipe set with clamps suitable for the size of DG sets IN REPLACEMENT of following capacity:-
20 KVA to 40 KVA
62.5 KVA to 82.5 KVA
100 KVA to 140 KVA
160 KVA to 200 KVA
320 KVA to 400 KVA
Servicing of alternator / AVR of DG set of any make and type by disconnecting all connecting all electric connections and removing dust from alternator/AVR and checking of wiring complete if burnt replace the wire with same size of conductor and making connection of all components for the following capacity :-
20 KVA to 40 KVA
62.5 KVA to 82.5 KVA
100 KVA to 140 KVA
160 KVA to 200 KVA
320 KVA to 400 KVA
S&F, Oil filter cartage element with O ring of DG set complete IN REPLACEMENT as per existing sample as following capacity:-
20 KVA to 40 KVA
62.5 KVA to 82.5 KVA
100 KVA to 140 KVA
160 KVA to 200 KVA
320 KVA to 400 KVA
S&F, Air filter (both outer & Inner) element IN REPLACEMENT with O ring for DG set complete as following capacity:-
20 KVA to 40 KVA
62.5 KVA to 82.5 KVA
100 KVA to 140 KVA
160 KVA to 200 KVA
320 KVA to 400 KVA
Cleaning of diesel tank of any size /capaity including replacement of worn-out pipe line and measuring scale and make it leak proof, replacement of connection fuel inlet drain with bush, re-fixing in original position with necessary clamps, nut & bolts, complete all as specified & directed..
S&F, Turbo Charger as per the existing including testing, IN REPLACEMENT complete for the following capacity :-
20 KVA to 40 KVA
62.5 KVA to 82.5 KVA
100 KVA to 140 KVA
160 KVA to 200 KVA
320 KVA to 400 KVA
S&F, Common spare parts of DG sets IN REPLACEMENT complete as following:-
Engine oil 15 W 40.
Brass terminal heavy duty for battery.
Distrilled water
Acid mixed water
Water temperature gauge sensor
Injector overflow pipe
Thermostat
Fuel feed baby pump
Asbestos rope superior quality on exhaust silencer pipe
Oil pressure gauge as per existing sample & capacity
Temprature gauge for oil / water
Fuel/oil pipe lines (High pressure rubber pipe covered with steel armoured)
Oil temprature gauge 0-130º C
Water temprature gauge 0-130º C
DC ammeter 0-50Amps
AC ammeter 0-500Amps
DC Voltmeter 0-50Amps
AC Voltmeter 0-500Amps
Frequency meter
Tachometer cable
Ignition switch DC with Key
Oil pressure gauge 0-7 Kg/Sqcm (Cat Part No 46.244.01)
Self starter for 12 Volts DC
Self starter for 24 Volts DC
Stopper 12 v
S&F, Rubber Hose pipe different size for radiator,air cleaner to turbo, turbo to sump,injector to filter,filter to tank,filter to tank
S&F, Copper battery lead connection IN REPLACEMENT suitable for 2 x 12 V, 180 A H battery 1.2 mtr long each for positive & Negative connections and 0.5 mtr long for battery inter connection lead duly pre soldering and fixing of lugs and end copper terminal and testing complete.
S&F, Relay 12Volts 25 Amp Cat 111x2-12-60 IN REPLACEMENT complete.
S&F, Engine Safety control unit 20 KVA to 140 KVA IN REPLACEMENT complete.
S&F, Safety control Unit-ECR-19 A for 160 KVA to 400 KVA IN REPLACEMENT complete.
S&F, Maintnance free battery with initially charged 12 volt with 24 months warrenty IN REPLACEMENT as following capacity.
S&F, Autocut electrical battery charger of 10 Amp Unit SMPS with Constant Voltage output with Battery charging Transformer and moulded type rectifier unit IN REPLACEMENT as following capacity.
S&F, Coolant for DG sets as per DG set Manufacturer's recommendations IN REPLACEMENT complete.
S&F, Door hinges suitable for DG set sound proof enclosure, of any capacity & make, for smooth opening & closing as IN REPLACEMENT complete.
S&F, Door Locks suitable for DG set sound proof enclosure, of any capacity & make, for smooth opening & closing as IN REPLACEMENT complete.
S&F, Door Handles suitable for DG set sound proof enclosure, of any capacity & make for smooth opening & closing as IN REPLACEMENT complete.
Repair / overhauling of DC Alternator by dismantling from the DG set after taking out the fan belt and pulley, replacement of armature coil, carbon etc and re-fixing the same, testing complete for DG set of capacity 20-400KVA, complete.
S&F, Fan belt set as per existing IN REPLACEMENT complete.
Servicing of self starter assembly of DG set by disconnecting the self starter assembly from the engine and dismantling , cleaning, all accessories,replacing worn-out parts like carbon brushes, penion of existing teeth, bendex bushes, armature, solenoid assy 12 Volt contact plates etc and rewinding the u/s feild coil etc and varnishing complete as following capacity:-
MAINTENANCE / REPAIR WORKS TO AMF PANEL OF DG SETS
Maintenance, repair, servicing of automatic mains failure panel 24Volt DC and 440Volt AC supply operated system by locating faults and replacement of userviceable parts and components, complete all as specified and directed, as per following:- (a) Repair of faulty worn out control wiring DC/AC for engine starting and off, with adequate and suitable size copper conductor wire, connected with proper copper lugs & terminals through protection pipe/casing. (b) Repair of worn out/faulty internal wiring of controls and timers, indicating/measuring instruments through various control fuses and relays with suitable and adequate size of copper conductor wire, connected with suitable copper lugs and terminals. (c) Replacement of worn out small control fuses, indicating lamps, various type of copper lugs, thimbles terminals all as deemed necessary or directed including minor spare parts and components in order to make system serviceable and perfectly in working order (d) Testing of system on load. NOTE:- Spare parts IN REPLACEMENT will be measured and paid for separately under respective item of BoQ.
S&F, Solid state electronic engine starting relay 12/24 volts DC
S&F, Alternator voltage monitor relay 3 phase 415 Volt
S&F, Main voltage monitor relay 3 phase 415 Volt
S&F, Under voltage monitor relay 3 phase 415 Volt
S&F, Solid state electronic timer 0-60 second, 24 volts DC
S&F, Electronic earth fault relay for alternator protection 24volts DC
S&F, Electronic over load relay for alternator protection 24volts DC
S&F, Power Contactor MCX 03 cat No. CS 97011, rating 32 Amp , 3 phase 4 pole, 415 volt
S&F, Power Contactor MCX 13 cat No. CS 97015, rating 80 Amp , 3 phase 4 pole, 415 volt
S&F, Power Contactor MCX 33 cat No. CS 97021, rating 200 Amp , 3 phase 4 pole, 415 volt
S&F, Power Contactor MCX 41 cat No. CS 97023, rating 325 Amp , 3 phase 4 pole, 415 volt
S&F, Front mounting aux contact block 2 NO + 2 NC cat No. CS 94114, rating 32 Amp , 3 phase 4 pole, 415 volt
S&F, VMR relay
S&F, Tyre Nylone 16 ply with tube inner of size 6.00-16 for trolly mounted DG sets IN REPLACEMENT complete.
Opening / dismantling and taking out existing unserviceable alternator from DG set and transporting to civil workshop, taking out burnt out winding of stator & rotor and other defective parts from the alternator & including re-winding of stator with superenamalled copper wire of existing size, H class & re-winding of rotor main field coil with superior quality copper strip of existing size, H class including required insullation material viz hardner, varnish, sleeve, mechanical lathework, re-winding of rotary rectifier including all other minor unforseen parts of alternator rrequired in the re-winding and transporting back to site and re-fixing the same in DG set, testing the DG set to entire satisfaction Engineer-in-charge of following capacity/ rating as under: -
20 KVA to 40 KVA
62.5 KVA to 82.5 KVA
100 KVA to 140 KVA
160 KVA to 200 KVA
320 KVA to 400 KVA
S&F, Front operated on load Change over switch 200 Amp 4 pole ie-400A ue 415V, AC -23B, ui-1000 A,IS-13947 (P-3) IEC-60947 (P-3) B-10330 as per existing fitted in AMF panel IN REPLACEMENT complete.
S&F, Front operated on load Change over switch 400 Amp 4 pole ie-400A ue 415V, AC -23B, ui-1000 A,IS-13947 (P-3) IEC-60947 (P-3) B-10330 as per existing fitted in AMF panel IN REPLACEMENT complete.
M&L for Spray painting of DG set, Alternator, Panel ,diesel tank and base frame etc. with two coat of synthetic enemel paint as per MES colour code after reparing to broken parts of body with gas welding ,cleaning of old painted surface by rubbing/removing of old paint and making surface reddy for painting to the DG set ofbcapacity upto 400 KVA complete all specified and directed.
M&L for Earthing with and including copper earth plate electrode 3.15 mm thick of size 600 mm x 600 mm with 20 mm x 3 mm copper earthing strip complete all as shown in electrical plate No. 3 and as specified in Particular Specifications clause 19.1.2 of contract, IN REPLACEMENT complete all as specified and directed . NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate. (b) Factory made PCC pit with cover shall be fixed at least 500 mm away from earth pit. (c) Earth resstance shall be less than 2 ohm. In case the test results are not found less than 3 ohm, complete earthing shall be redone by the contractor without any extra cost to Govt.
NOTES APPLICABLE TO SERAL ITEM NO. 1 TO 34 :- (i) To maintain utmost security at AF Station, contractor will arrange his workmen along with T&P in a manner that nonfunctional DG Set / AMF Panel is made functional swiftly within 24 hour of receiving of complaint from the MES, during entire contract period. (ii) Not withstanding with the provision of "Compensation for Delay' envisaged under condition 50 of IAFW-2249, General Conditions of Contracts, additional compensation @ Rs. 500/- day will be charged from contractor in case he fails to make the DG Set / AMF Panel functional to the entire satisfaction of Engineer-in-Charge within 24 hour of receiving of complaint from the MES regarding non working DG Set.
Note : Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline.
TARA ENTERPRISES (BID ID -3353012)
M/S BALWINDER SINGH (BID ID -3348829)
Northern cable fault locatoers (BID ID -3355119)
Fabtech Engineering (BID ID -3363613)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .