Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹36.4 L+₹3.9 L (12.1%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹45.0 L+₹12.5 L (38.4%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L3 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
30 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
PROVN OF OH TO UG CABLES FOR VARIOUS UNITS INCLUDING PROVN OF 6X2 TON AC (HOT AND COLD) UNDER AGE E/M OF GE 862 EWS
2023_MES_625222_1
GER-56/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹97,000
Yes
16 Dec 2023
27 Oct 2023
2 Dec 2023
27 Oct 2023
30 Nov 2023
11 Nov 2023
Amount
Supply, laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 4 core laid in trenches, ducts, pipes, on poles and making connection with necessary cables lugs and glands complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling, sand cushoining, cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply, laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sqmm 4 core laid in trenches, ducts, pipes, on poles and making connection with necessary cables lugs and glands complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling, sand cushoining, cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply, laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and making connection with necessary cables lugs and glands complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling, sand cushoining, cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
S&F for LED in repair street light fitting 70 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lenses with IP 65, complete with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 Sqmm copper cable from connector to fitting, complete all as specified and directed
Supply and erecting for steel tubular swaged poles errected to truly vertical position with 6mm thick mild steel base plate of size 300mm x300mm, welded to Pole, B-118 finial taper plug, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II, type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally and portion embedded in concrete, making five black and white bands at lower portion of pole each 300mm wide at 300mm spacing alternately and marking pole number. with black paint at suitable height including taking down old unserviceable pole complete all as specified and directed. (Note :- Necessary excavation of earth work, removing, returning filling in, PCC foundations of poles, coping etc shall be measured and paid separately)
S&F in replacement for GI bracket pipe of size 50mm dia medium grade of 1.2 m long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket pipe shall be fixed on wall/pole surface by providing suitable MS iron 50x4mm clamps 2 Nos of lenths as required at site to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts & washers complete all as specified and directed.
S&F for FRP looping / junction box of size 300x200x105mm with connector 3 P & N and comprising of MCB SP 6 Amps, ISI marked, 240V complete with and including providing GI clamps, nuts bolts etc suitable for fixing on wall / steel tubular pole etc including taking down old junction /looping box complete all as specified and directed.
S&F for copper conductor cable, PVC insulated, sheathed, flexible, multistranded, ISI marked, 1100 Volts grade, 3 core 1.5 Sqmm and including connection and testing complete all as specified and directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm on plan for laying of cable and foundation of poles stays and getting out in soft / loose soil complete all as specified and directed.
All as per Srl item No 9.00 here-in-before but exceeding 1.5 m and not exceeding 3 m in depth and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
M&L for cable route indicator LT type made of metal cast iron, the strip size not less than 32x4 mm, height 300mm and round shape of dia not less than 8 cm with embossed LT welded or reveted strip and round plate each other including adequate qty of PCC 1:3:6 type C-1 20mm graded agregates, complete all as specified and directed.
M&L for 50mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for cable protection complete all as specified and directed.
M&L for 80mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for cable protection complete all as specified and directed.
M&L for PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete of poles and stay/installation paths complete all as specified and directed.
M&L for plain cement concrete type B-1 , 1:2:4 (using 20mm graded stone aggregate) as in coping of poles, benching, hold fasts, water troughs, bed block and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
Supply , install, testing and commissioning of factory made outdoor type electric LT panel board (IP-55) fabricated out of 3.15mm thick CRCA sheet dust and vermin proof powder coated double door type independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 volts, 3 phase, 4 wire, 50 HZ AC supply system, internally wired with copper conductor/strip of adequet size from main incoming MCCB to busbar and bus bar to outgoing MCCB/MCBs having legs of 45cm made out of 65x65x6mm angle iron grouted on brick masonry platform upto 30cm . Brick masonry platform should be 30cm above the ground level comprising the following parts :- (a) MCCB 100 Amp, 4 Pole, 50 Hz, 415 V, having rupturing capacity 36 KA-01 No (thermal magnetic) release and adjustable on load (b) MCB, FP, 40Amps, 50 Hz, 415 Volt, 'C' curve/series, having rupturing capacity 10KA-5 Nos (c) Digital voltmeter with VSS-01 Set (d) Ammeter with CT's and ASS -01 set (e) LED phase Indicator set RYB 01 set of 3 pcs LED type - 1 set (f) Aluminium bus bar, TPN, 200 Amp rating-01 set (g) Change over 100 amp-01 No (h) Time Switches 250v 3 phase of 20amp rating with contactor-01 No Notes : (i) Rates are deemed to be inclusive of brick massonry platform of suitable size of 30 cm height and 04 Nos legs of 65mm x 65mmx6mm for fixing the panel (ii) MCCB & MCB shall be fixed in suitable sheet metal enclouser made up of 3.2mm thick CRCA sheet. (iii) Danger notice plate (02 Nos) LT size 20cm x 15 cm shall be fixed on the panel (iv) Panel shall be from CPRI approved make.(v) Make of panel and drawing shall be got approved from GE before placing order for procurement
Supply , installation, testing and commissioning of factory made bus bar chamber panel of size 600mmx 900mmx350mm ( CPRI approved) out door type 3.15 mm with 4 strips 200 Amps bus bar aluminium, with MCCB of 40 Amp, FP, 16 KA adjustable type duly connected to aluminium strip at incoming side with suitable space for 2 incoming cable and outgoing of 2 cable. Bus bar fixed on insulators in zig-zag position, clearance in each strip and clearnace at both side should not be less than 125mm with sufficient working space, height of bus bar chamber not less than 1 mtr, mounted MS angle 50mmx50mmx6mm, made of CRCA sheet 2mm thick outdoor type powder coated after seven tank process both side opening, shutter in two parts, cable opening form bottom side with indicators R,Y,B, hinges through out the length of shutter with half turn locking arrangement, including grounting in PCC, complete all as directed by Engr-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 25X4mm thick galvanised iron strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete all as specified and directed. (Note:-Earthwork, Earth strip and protection pipe upto board is included in the rate quoted)
Dismantling & taking down ACSR conductors of any size including cross arms and insulators from existing poles and removing from site complete all as specified and directed.
Dismantling & taking down cross arms of any size from existing poles and removing from site complete all as specified and directed.
Dismantling & taking down insulators from existing poles and removing from site complete all as specified and directed.
Supply and install Hi wall split units indoor/ outdoor complete with cordless remote control unit and with cooling and heating function of cap 2.0 Ton, 5 Star rated, invertor technology. The complete outdoor unit shall consist of compressor, condenser coil, Expansion coil and capalliary tube whereas indoor unit shall include copper cooling coils, air blower and air filter. The heating should be based on reversible cycle. The split air conditioner should include multipurpose stand wall mounting out door unit stand with complete nuts and bolts and groutig charges etc including connecting copper tubing/ pipes of suitable size, insulated with insulating material with LCD remote, filled with refrigerent, connectig cable as reguired and specified includig all accessories complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. (Note : - 02 run of 4 sqmm single core copper conductor cable and 01 run of 4 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
S&F for sheet metal enclosure with two pin and earth plug socket complete with one single pole MCB 20 amps complete all as specified and directed.
Supply and installation of voltage stabilizer of capacity 5 KVA, copper wound single phase naturally air cooled indoor type and designed for input variation between 170v to 250v with output voltage stabilized at 230v with accuracy of +/- 2.5% complete all as specified and directed by Engineer in Charge.
M/S PARSHOTAM KUMAR GUPTA
NATIONAL TRADING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .