Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical NUWAN ALAWALPUR GHAZIPUR GHAZIPUR GHAZIPUR UTTAR PRADESH 233222 | GHAZIPUR | UTTAR PRADESH | 233222 | Accepted-Technical OKAY |
| 2 | Accepted-Technical | Accepted-Technical OKAY |
Tender Value
₹9.9 L
EMD Value
₹10,000
Closing Date
30 Apr 2026, 11:00 amClosed
Superintending Engineer
Ist Floor 33/11 KV Civil Lines Substation, Civil Line Prayagraj
Supply of Various Materials.
2026_PVVNV_1136322_1
01/EUDC-II/Pra/SE/2026-27
Open Tender
Supply of Materials
Lump-sum
90 days
Prayagraj
As per Tender Specification
2 documents required · 2 mandatory
₹1,180
S.E. EUDC-II, Prayagraj
₹10,000
5 May 2026
13 Apr 2026
30 Apr 2026
13 Apr 2026
30 Apr 2026
13 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | Item Details | - | - | - | - |
| - | Epoxy resin cast indoor type single core, Single phase potential transformers with dry type Epoxy resin cast, air-cooled and as per IS: 3156/1992 or latest amendment thereof. The primary and secondary winding of 33 KV PT should be wound on insulating craft paper. The PTs. shall have a ratio of 33 KV / 110 V and with a rated burden of 25 VA and of accuracy class 0.5. The material of primary and secondary winding should be copper. There will be no HT fuses in the primary side and secondary side of the potential Transformers. Rated voltage factor of PT should be as per ISS. Potential transformer should be type tested and routine tested as per IS: 3156:1992 or latest version thereof. | 10 | Nos. | - | - |
| - | Epoxy resin cast indoor type single core, three phase potential transformers with dry type Epoxy resin cast, air-cooled and as per IS: 3156/1992 or latest amendment thereof. The primary and secondary winding of 11 KV PT should be wound on insulating craft paper. The PTs. shall have a ratio of 11 KV / 110 V and with a rated burden of 25 VA and of accuracy class 0.5. The material of primary and secondary winding should be copper. There will be no HT fuses in the primary side and secondary side of the potential Transformers. Rated voltage factor of PT should be as per ISS. Potential transformer should be type tested and routine tested as per IS: 3156:1992 or latest version thereof. | 35 | Nos. | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.47 MB
Tender_No_01.rar
Tender Documents • 0.13 MB
BOQ_2121918.xls
BOQ • 0.28 MB
228.pdf
PDF • 0.44 MB
176.pdf
PDF • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .