Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹39.5 L+₹1.6 L (4.31%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest tenderer | |
| 3 | L3₹40.3 L+₹2.4 L (6.38%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest tenderer | |
| 4 | L4₹47.2 L+₹9.4 L (24.8%)Rejected-Finance 50A 7B 5C UMARPUR NIWA DHOOMANGANJ PRAYAGRAJ UP | PRAYAGRAJ | UTTAR PRADESH | 211011 | L4 | Rejected-Finance Other than Lowest tenderer |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
2 Jan 2024, 6:00 pmClosed
Vipin Chandra Rai
GE Utility Bathinda
REPAIR/MAINT OF DG SETS AND CONNECTED ITEMS INSTALLED AT WATER SUPPLY INSTALLATIONS AT VARIOUS LOCATION UNDER GE(U) BATHINDA.
2023_MES_630873_1
8767/2023-24/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
Class D cat b i
9 documents required · 9 mandatory
₹500
Garrison Engineer (U) Bathinda
₹1 L
Yes
19 Jan 2024
2 Dec 2023
4 Jan 2024
2 Dec 2023
2 Jan 2024
18 Dec 2023
Amount
M&L for 'B' check of DG Setsof capacity 20KVA to 63KVA complete as per following :- (i)Draining out engine/lubricant oil flushing including filling fresh oil afterdrain out old oil by skilled trademan of DG set including replacement of oil pan /chamber gasket . (ii)S& F in replacement lubricant oil filter element . (iii)S&F in replacement fuel filter element. (iv)S&F bypass filter element. (v)checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required. (vi) General cleaning of oil/fuel spills, grease spots etc. (vii) Checking of belt tension and adjusting as per requirment.
All as per Srl item No 1.00 but DG Set Cap 100 KVA to 200KVA.
All as per Srl item No 1.00 but DG Set DG Set Cap 250 KVA to 320KVA.
M&L for 'C' check of DG Sets of capacity 20KVA to 63KVA complete as per following :-(i)Draining out engine/lubricant oil flushing including filling fresh oil afterdrain out old oil by skilled trademan of DG set including replacement of oil pan /chamber gasket . (ii)S& F in replacement lubricant oil filter element . (iii)S&F in replacement fuel filter element. (iv)S&F bypass filter element. (v)checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required. (vi) General cleaning of oil/fuel spills, grease spots etc. (vii) Checking of belt tension and adjusting as per requirment. (viii) Check all electrical conditions (ix)Check pollution level(X) Check water separator and radiator cleaning with chemical. (x) Change hydraulic governor oil,Change aneroid oil, check aneroid adjustment, Replace aneroid breather. (xi) Clean radiator externally, Check fan hub/Idler and water pump/idler. (xii)Inspect units, Check Alternator/Generator,Starter etc, Check air cleaner if required(Amount of air filter will be paid separately), Evacuator valves change if required.
All as per Srl item No 4.00 but DG Set Cap 100KVA to 200KVA.
All as per Srl item No 4.00 but DG Set DG Set Cap 250 KVA to 320KVA.
Taking out the self starter 24 Volt of DG Set capacity 320 KVA DG Set Make-Kirlosker and shifting to workshop for rewinding of armature including replacement of unserviceable,bushes & minor parts & reinstalling the same after testing complete as specified. Note:- Spares replaced will be measured and paid seperatly under relevent item here in after as supply only
Taking out the self starter 24 Volt of DG Set capacity200 KVA DG Set Make-Kirlosker and shifting to workshop for rewinding of armature including replacement of unserviceable,bushes & minor parts & reinstalling the same after testing complete as specified. NOTE:-Spares replaced will be measured and paid seperatly under relevent item here in after as supply only
Taking out the self starter 24 Volt of DG Set capacity 100KVA DG Set Make-Kirlosker and shifting to workshop for rewinding of armature including replacement of unserviceable,bushes & minor parts & reinstalling the same after testing complete as specified. NOTE:-Spares replaced will be measured and paid seperatly under relevent item here in after as supply only
Taking out the self starter 12 Volt of DG Set Cap 20KVA to 63 KVA Kirloskar and shifting to workshop for rewinding of armature including replacement of unserviceable,bushes & minor parts & reinstalling the same after testing complete as specified.
Taking out the charging alternator of DG Set capacity 320KVA and shifting to workshop for rewinding of armature including replacement of rewinding unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified. NOTE:-Spares replaced will be measured and paid seperatly under relevent item here in after as supply only
Taking out the charging alternator of DG Set capacity 200 KVA and shifting to workshop for rewinding of armature including replacement of rewinding unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified. NOTE:-Spares replaced will be measured and paid seperatly under relevent item here in after as supply only
Taking out the charging alternator of DG Set capacity 100 KVA and shifting to workshop for rewinding of armature including replacement of rewinding unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified. NOTE:-Spares replaced will be measured and paid seperatly under relevent item here in after as supply only
Taking out the charging alternator of DG Sets 20 KVA to 63 KVA DG Set Make - Kirloskar and shifting to workshop for rewinding of armature including replacement of unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified.
Servicing of radiator assembly of DG Sets 200 KVA and replacement of minor parts to make it operational including descaling of tubes with solution and chemicals and compressed air blast including transportation to workshop and back and re fixing after testing complete and making it leak proof completeincluding replacement of worned out tubler hoses alongwith clip etc all as specified and directed.
Servicing of radiator assembly DG Sets 20 KVA to 63 KVA and replacement of minor parts to make it operational including descaling of tubes with solution and chemicals and compressed air blast including transportation to workshop and back and re fixing after testing complete and making it leak proof complete all as directed.
Servicing of radiator assembly DG Sets 100Make - Kirlosker and replacement of minor parts to make it operational including descaling of tubes with solution and chemicals and compressed air blast including transportation to workshop and back and re fixing after testing complete and making it leak proof complete all as directed.
Supply only air cleaner filter for DG Set capacity 320 KVA complete all as directed.
Supply only air cleaner filter for DG Set capacity 100 KVA complete all as directed.
Supply only air cleaner filters for DG Set Cap 20 KVA to 62.5 KVA complete all as directed.
Supply only air cleaner filters for DG Set Cap 200 KVA complete all as directed.
Opening the coupling of DG Set of capacity 320 KVA , dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as directed.
Opening the coupling of DG Set of capacity 20 to 63 KVA, dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as directed.
Opening the coupling of DG Set of capacity 100 KVA, dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as directed.
Opening the coupling of DG Set of capacity 200 KVA, dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as directed.
Servicing of fuel pump /hand pump assembly to make it fully fuctional and fixing it to its original position of DG Set in any capacity including replacement necessary element complete all as directed..
Repair and maintenance of FIP including replacement of Plunger, Governer kit with pin, Nozzles P type,Head ball guide kit, Head sheet (set of 12 piece) Rock rod,Rollar bearing,Oil seal, Piston pin, Gasket kit and sleeves complete all as directed. DG Set of 20 KVA to 63.5 KVA. Make-Kirloskar, Cummine Mahindra
Repair and maintenance of FIP including replacement of Plunzers, Governer kit with pin, Nozzles P type,Head ball guide kit, Head sheet (set of 12 piece) Rock rod,Rollar bearing,Oil seal, Piston pin,Gasket kit and sleeves complete all as directed. DG Set of 100 KVA Make-Kirloskar, Cummine, Mohindra
Repair and maintenance of FIP including replacement of Plunzers, Governer kit with pin, Nozzles P type,Head ball guide kit, Head sheet (set of 12 piece) Rock rod,Rollar bearing,Oil seal, Piston pin,Gasket kit and sleeves complete all as directed. DG Set of 200 KVA Make-Kirloskar,Cummine,Mohindra
M&L for calibration of fuel injector assembly of DG Set of 100 KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc, complete all as directed.
M&L for calibration of fuel injector assembly of DG Set of 20KVA to 63KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc, complete all as directed.
M&L for calibration of fuel injector assembly of DG Set of 200KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc, complete all as directed.
M&L cleaning of diesel tank of DG Set of any capacity including replacement of worn-out pipe line and measuring scale and fixing in original position and make it leak proof with necessary clamps complete all as directed.
S&F in replacement of AVR for DG Set of capacity 20 KVA to 63.5 KVA .Model No.(i)CS3C0 14D1568-H (ii)LBS3K14L19548-H(iii)ES3A014A1867D8 complete all as directed..
S&F in replacement of AVR for DG Set of capacity 100 KVA(Model No.6BTA5.9G1-I ) to 200KVA(.Model No. FS3M109J89152) complete all as directed
S&F in replacement of AVR for DG Set of capacity 320KVA. Model No.(i) GS3C0110132632 (ii)GS3C010D101788 complete all as directed
S&F in replacement of high pressure oil pipe ss as per sample of DG Set of any capecity complete all as directed
S&F in replacement of Bentex wheel complete suitable for self starter complete all as directed
S&F in replacement of Battery Terminals Copper.(Positive & Nagative) complete all as directed
S&F in replacement of Battery Copper cable Red with plug of size 35 sqmm complete all as directed
S&F in replacement of Battery Copper cable Black with plug of size 35 sqmm complete all as directed
Supply & pouring in replacement of K cool super plus-50-50 PREMIX of 1 Ltrs sealed Packing complete all as directed.
Supply & pouring in replacement of engine oil for DG sets 20W/40 grade CRB plus into the oil sump complete all as directed
S&F in replacement of Fuel pipe / Hose pipe for DG Set complete all as directed
S&F in replacement fan belt set suitable for DG Set of any capacity of existing size complete all as directed.
S&F in replacement hinges suitable for DG Set of any capacity of existing size complete all as directed.
S&F in replacement Battery of 12V-180AH complete all as directed. Make: Exide/SF Sonic
S&F in replacement Battery of 12V-130AH complete all as directed.
S&F in replacement Battery of 12V-100AH complete all as directed.
S&F in replacement water pump assembly ccomplete all as directed
S&F in replacement fan assembly along with hub suitable for DG Set of any cap complete all as directed
M & L for Earthing complete with galvanised iron steel plate electrode 600x600x6 mm burried directly in ground vertically in the pit of depth not less than 2.25 mtr below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides with mixture of charcoal and comman salt in alternate layers and electrode connected to galvanised iron strip 32x6mm by means of nuts bolts. The earth strip protected by 40 mm medium grade GI pipe upto test point complete all as shown in electrical plate NO 3 of SSR part I incl 20 mm bore medium grade GI pipe for waterring incl PCC chamber on the top of the earth complete all as specified and directed. Note:- Quoted rate deemed to be inclusive of excavation and earthwork, PCC pit and cover.
S&F in replacement of change over switch Capacity 800 Amps,415 Volts,FP,50 HZ ,manually Operated complete all as directed Make: L&T/ INDOASIAN
S&F in replacement of change over switch Capacity 400 Amps,415 Volts,FP,50 HZ ,manually Operated complete all as directed. Make:L&T/ HAVELLS/LEGRAND/SEIMENS
S&F in replacement of change over switch Capacity 200 Amps,415 Volts,FP,50 HZ ,manually Operated complete all as directed. Make:L&T/ HAVELLS/LEGRAND/SEIMENS
S&F in replacement of change over switch Capacity 160 Amps,415 Volts,FP,50 HZ ,manually Operated complete all as directed. Make:L&T/ HAVELLS/LEGRAND/SEIMENS
Disconnecting the battery 12 Volts 180 AH from the DG set shifting to workshop for further dismantling for repair/replacement of cells, plates, reconditioning, filling of electrolyte of required specific gravity and charging the battery, after repair shifiting the batteries from workshop to E/M installation fixing to the DG set testing complete all as directed
M & L for cleaning of DG sets including removing of oil grees and etc spot washing carefully with soda water preparation of old painted surface and painting to the DG sets of capacity 62.5 to 320 KVA with two coat of spray painting of approved make and colour of first grade paint and making SM/MES No complete all as directed
Supply only distilled water for lead acid battery complete all as directed
Supply and laying in replacement of XLPE insulated,3.5 Core,415 Volt, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm complete all as directed. Make: HAVELLS INDIA LTD/ UNIVERSAL CABLES LTD, SATNA / POLYCAB WIRES PVT LTD (POLY CAB) / FINOLEX
Supply and Fixing in replacement power contactor 415 volt, 50 cycles,3 phase,type MCX33 complete all as directed. Make:L&T/ HAVELLS/LEGRAND/SEIMENS
Supply and Fixing in replacement MCCB 400 Amps, 4 pole ,415volt,50 cycles, breaking capacity 36 KA, thermal magnetic release complete all as directed Make:L&T/ HAVELLS/LEGRAND/SEIMENS
Supply and Fixing in replacement MCCB 250 Amps, 4 pole ,415 volt,50 cycles, breaking capacity 36 KA, thermal magnetic release complete all as directed Make:L&T/ HAVELLS/LEGRAND/SEIMENS
Supply and Fixing in replacement MCCB 200 Amps, 4 pole ,415 volt, 50 cycles, breaking capacity 36 KA, thermal magnetic release complete all as directed Make:L&T/ HAVELLS/LEGRAND/SEIMENS
Supply and Fixing in replacement MCCB 160 Amps, 4 pole ,415 volt, 50 cycles, breaking capacity 36 KA, thermal magnetic release complete all as directed Make:L&T/ HAVELLS/LEGRAND/SEIMENS
Supply and Fixing in replacement MCCB 63 Amps, 4 pole ,415 volt,50 cycles, breaking capacity 36 KA, thermal magnetic release complete all as directed Make:L&T/ HAVELLS/LEGRAND/SEIMENS
Repairs / Maintenance of AMF pannel by removing all the connections including MCCBs, Contactor and all connected items and replacement of unserviceablr items or refixing the same after cleaning or decarbonation , and testing, complete all as directed Note :- (i) Rate of replacement of MCCBs and Contactors wil be Paid seperately. (ii) Rate of replacemet of minor parts like MCBs and Controlling wire are included in the quoted rates.
Repairs to Portable Battery Charger by shifting to workshop for further dismantling for repair/replacement of connected items, after repair shifiting the same from workshop to E/M installation testing, complete all as directed
Supply and fixing in replacement locking system of DG Set Diesel Tank of any capacity complete all as complete all as directed
Supply and fixing in replacement locking system of DG Set gate of any capacity complete all as directed
Supply and fixing in replacement display unit of 320 KVA DG Sets. Display Board features of micropressesor based KG 934 controller :- (i) Engine parameter display:- Engine oil pressure,Engine temp,lab oil temp,canopy temp, Battery voltage,Engine RPM,Engine Running Hrs,Fuel level indicator,%of tank capacity. (ii) Engine protection:-Low oil pressure,High/low battery voltage,High engine temp, low radiator coolant level,Engine over speed,Engine under speed,low fuel level in diesel tank,Battery charging indicator. (iii)Electrical parameter display:-voltage,line to line ,line to neutral,DG load current,Gen load voltage,frequency,load power factor,KW,KVA (iv) Electrical protection:-Over voltage,under voltage,over KVA,over Current.
All as per srl item no 73 as above but for capacity 200 KVA DG Set.
All as per srl item no 73 as above but for capacity 100 KVA to 120 KVA DG Set.
All as per srl item no 73 as above but for capacity 63 KVA DG Set.
All as per srl item no 73 as above but for capacity 30 KVA to 40 KVA DG Set.
M/s Kataria Construction Company
M/s NIRMAN BUILDERS
SS CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .