Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹59.7 L+₹56,523 (0.96%)Rejected-Finance H NO 209 D SHRI SHIVA NAGAR IV MANCHARA SIKAR ROAD JAIPUR | JAIPUR | JAIPUR | RAJASTHAN | 302013 | L2 | Rejected-Finance L2 | |
| 3 | L3₹60.1 L+₹1.0 L (1.76%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹61.9 L+₹2.8 L (4.81%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹66.7 L+₹7.5 L (12.8%)Rejected-Finance 70 VARDHMAN NAGAR A P O SHYAM NAGAR AJMER ROAD JAIPUR PIN 342019 | JAIPUR | 342019 | L5 | Rejected-Finance L5 |
Tender Value
₹71.5 L
EMD Value
₹1.3 L
Closing Date
17 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Jaipur
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
ADDN ALTN AND RENOVATION OF BLDG NO P01 AND P02 FOR COVID WARD AT MH JAIPUR UNDER ZONEII AREA AT JAIPUR STN
2020_MES_348406_1
GE/J-08/2020
Open Tender
Civil Works
Item Rate
60 days
GE Jaipur
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE Jaipur
₹1.3 L
Yes
22 Jun 2020
29 May 2020
19 Jun 2020
29 May 2020
17 Jun 2020
4 Jun 2020
29 May 2020 - 3 Jun 2020
60 days
Amount
Taking down cement plaster on roof surfaces including existing roof treatment and remove the demolished material outside MD land. Complete all as directed.
M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean drysand 1:1 (by weight).
M&L for screed/plaster 15mm thick in (CM 1:4) on roof for surfaces mixed with applied liquid type water proofing compound as per manufacture instuctions. Work or concrete surfaces.
Supply only liquid water proofing compound
M&L 25 mm thick cement concrete type B-0 (using 12.5mm size graded stone aggregates) average as in RCC roof surface to horizontal and vertical surfaces , finish the surfaces even and smooth using extra cement including necessary form work all as specified and directed.
M&L applying a coat of bituminous primer conforming to IS-3384 @ 0.40 Kg per Sqm, APP based polymeric membrane not less than 3mm thick, weighing not less than 3kg/Sqm, reinforced with polyester non-woven fabric (weighing not less than 150gm/Sqm) shall be laid by torch application. Side overlaps shall be 75mm and the end laps shall be 100mm and all overlaps and joints shall also be sealed by torch application including one coat of bituminous aluminium paint all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
Glazed ceramic coloured tiles ( 450 x 300 mm) x 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps ,wall etc set over and incl 10 mm thick cement plaster in CM 1:6 and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L Machine cut kota stone slab flooring 20-25mm thick over and incl cement screed base 15 mm thick in 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over and incl 15 mm cement plaster in 1:6 jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M&L 16-18 mm thick Granite stone (table rubbed & polished) in steps, shelves, jambs & window cills/kitchen platform incl bedded & jointed with grey cement slurry & pointing in white cement using marble dust with admixture of pigment to match with marble shade of Granite stone & incl grinding & polishing the exposed edges over and incl 15mm thick screed bed in CM 1:4. Complete all as directed.
Rounding to edges of stone slabs (Kota / Granite/marble ) one edges such as in steps, cooking platform and other similar situations all as specified
Taking up or down steel tubing and connection, including cleaning 15 mm bore
Taking up or down steel tubing and connection, including cleaning 20 mm bore
GI tubing medium grade with all fitting 15 mm bore fixed to wall or concealed or fitted to ceiling or laid under floor
GI tubing medium grade with all fitting 20 mm bore fixed to wall or concealed or fitted to ceiling or laid under floor
S&F CP Angle valve cast copper alloy screwed down high pressure with capastan head, screwed both ends for iron pipe or for unions in 15 mm bore fixed in repairs.
Stop valves cast copper alloy screwed down high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions in 20 mm bore fixed in repairs.
S&F CP Bib taps, cast copper alloy with capastan heads ,screwed down, screwed for iron pipe or for brass ferrule and fixed in repair 15 mm
S&F in repair CP stop valves, cast copper alloy screwed down high presure, with Capastan head, screwed both ends fancy type chromium plated with long shank and cup (concealed type), 15 mm
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm
S&F in repair tubular towel rail 20 mm dia ,D type,60 cm long between flanges
Sheet Glass shelf assembly consisting of 5.5 mm thick shhet glass shelf 12 cm wide with chromium plated bracket guard and raling 60 cm long
S&F in repair Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule20mm
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm but including brackets, coupling and waste pipe complete
S&F in repair Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe 15mm
M&L PVC syphonic action type flushing cistern, low level white with inlet ball valve float and handle including brackets
Vitreous China wash down water closet (Pedestal pattern) complete fixed in repairs
M&L plastic water closet seat,black,closed patteren with flat bottom, and cover and mild sttel chromium plated or aluminium hinging device
PVC Grating doom 100 mm dia
PVC Grating doom 125 mm dia with waste hole
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I - Capacity 1000Litre
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I - Capacity 500 Litre
S&F in repair Vitreous China urinals, bowl type (back or corner wall type), of size 465 x 355 x265 mm of white colour complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipee. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
PVC (SWC) floor trap, with grating including jointing with solvent cement fixed in repair 75 mm bore
PVC (SWR) pipes single socketed in any length with rubber ring joints,laid in trenches or in floors dia of pipe 100 mm fixed in repair
PVC (SWR) pipes single socketed in any length with rubber ring joints,laid in trenches or in floors dia of pipe 75 mm fixed in repair
PVC (SWR) pipes single socketed in any length with rubber ring joints ficxed to walls dia of pipe 100 mm fixed in repair
S&F in repair PVC Bends 100/110mm bore, with oval access doors
S&F in repair PVC Bends 75 mm bore, with oval access doors
S&F PVC cowls 100 mm
Returing and filling in layers nexc 25 cm incl watering aand well running
Removal of surplus spoil upto a distance Exc 250 m but not exceeding 500 M and depositing where directed
Demolition of brick work or stone/bolder masonry built in cement mortar or cement lime mortar and removal of debris from Outsite of MD land .
M & L Brickwork old size brick with fly ash bricks, traight or curved on plan exc 6m mean radius, built in CM 1:4
Supply only integral water proofing compound.
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4)
M&L cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate as in bed blocks, copng etc including necessary form work and all as specified
M&L cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in benching including necessary form work all as directed and specified
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for
M&L precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for manhole cover slab set in cement mortar 1:6 including necessary form work. Note :- ( Reinforcement shall be measured and paid for separately.
M&L TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia
All as per item No 55 but for 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders.
S&F salt glazed stoneware drain pipes as per IS-651 150mm dia laid in trenches and jointed in cement complete all as specified.
M&L cement concrete 1:4:8 type D2 using 40mm graded stone aggregate to bed concrete to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150mm dia pipe
Cutting into existing manholes for connecting new drains of 150mm internal dai of pipes, making hood to pope and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required
Cutting holes into or through one brick thick wall in superficial area 150 sq cm built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required
Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110 for dia of pipe
Cleaning of drain pipes by rodding from manholes by mechanically or manually all as directed by Engr-in-Charge and or cleaning eye incl well flushing and placing back manholes covers after cleaning from 200 mm bore.
Bailing out water from manholes Manually and mechanically & taking out foreign material and removing same from MD lands incl taking out manholes covers and replacing manholes covers in position for manholes of any size & depth all as specified.
S&F salt glazed stoneware drain pipes as per IS-651 150mm dia laid in trenches and jointed in cement complete all as specified.
S&F PVC (SWR) junction double, (Double T) equal or unequal of 110mm bore of pipe
PVC (SWR) junction single, (Double T) equal or unequal of 75mm bore of pipe
S&F PVC (SWR) junction single, (Single T) equal or unequal of 75mm bore of pipe
S&F PVC (SWR) junction single, (Single T) equal or unequal of 110mm bore of pipe
Taking down cement plaster on brick / stone wall, ceiling etc incl. raking outs joints hacking for key scrubbing with water
Rendering 10 mm thick on ceiling in CM(1:3) finished even and smooth without using extra cement
M & L for preparation of newly plastered wall surfaces and applying two coat of oil emulsion distemper of any tint including priming plastered surfaces with alkali resistant priming paint over a coat of 3 mm thick putty in two layers.
Preparing newly plastered surfaces and applying three coats of white wash on ceiling including priming plastered surfaces with alkali resistant priming paint over a coat of 3 mm thick putty in two layers.
M & L for Preparing old plastered surfaces and applying two coat of oil emulsion distemper of any tint complete allas directed
M & L for removal of existing tretment of plastered wall surfaces and applying two coat of oil emulsion distemper of any tint including priming plastered surfaces with alkali resistant priming paint over a coat of 3 mm thick putty in two layers.
M & L for Preparing old plastered surfaces and applying two coats of white wash on ceiling
Preparing old plastered surfaces and applying two coats of white wash on ceiling including priming plastered surfaces with alkali resistant priming paint over a coat of 3 mm thick putty in two layers.
Preparing old wooden surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint
Preparing old steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint
Preparing old plastered surfaces and applying two coats of cement base paint complete all as directed
Preparing old plastered surfaces and applying two coats of cement base paint over one coat of exterior birla putty on wall after complete removal of existing treatment
Taking down chowkats or frames with shutters n. exc 1.50 Sqm each (without taking off shutters from the frames).
Taking down chowkats or frames with shutters exc 1.50 Sqm but not exceeding 4. sqm each (without taking off shutters from the frames).
S & F anodised aluminium window and ventilator / partition shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws , powder coating of any colour (Thickness or powder coating not less than 50 micron). etc. complete all as specified
S & F anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws, powder coating of any colour (Thickness or powder coating not less than 50 micron) etc. complete all as specified
M&L 5.0 mm thicktinted glass packing with rubber gasket, Al beading etc around both sides for fixing of glass all as specified and directed.
S & F aluuminium composite panel (ACP) alongwith fixture including all necessary supporting frame work with panel thickness of 4 to 6 mm as in decorative paneenilng fixed to vertical or horizontal pattern , fixed with screws on frame work make and shade as approved ny Engr in charge
S & f floor door stopper 140mm of aluminium alloy body and tongue, anodised with hard dran steel spring fixed in floor
S & F 150mm long aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and directed.
S & F 150mm long aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and directed.
Mortice lock, vertical type, size 100 mm brass 4 lever
S & F Door closer hydraulically regulated,designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed of aluminium die cast body
Resecuring and easingand adjusting of shutter without taking down of any description exc 1 sqm and not exc 1.5 Sqm
Resecuring and easing and adjusting of shutter without taking down of any description exc 1 sqm and not exc 2.00 Sqm
Hacking out old broken glass any thickness, size, quality from steel frames glazed with putty.
Sheet glass ordinary quality and glazingwith oil puttyin square n.exc 0.50 sqm in each pane in 3 mm thickness
Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples
Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples fixed in repair in wooden doors and steel windows
M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates to top of parapet wall to cover stair opening , verticla memeber will be fixed with hold fast and ms plaete complete all as specified and directed
M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws as specified..
Preparation of new steel & iron surfaces & applying two coats of synthetic enamel paint over 10 cm width or girth etc.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15 deep and getting out in soils
Excavation in trenches n.exc 1.5m wide & n.exc 1.50m in depth for foundation , etc or for shafts, wells, cess pits, man holes,pierholes etc n. exc 10 sqm on plan & getting out in soft/loose soil.
M&L PCC 1:4:8 Type D2 (40 mm graded aggragate) as in fdn, filling and mass concrete.
Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured)
Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area
Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall
M&L RCC M-25 (Design mix) as in Beams, cantilevers, bressummers, lintels over 1.5m span.
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement.
M&L rendering 15mm thick on other than fair faces of brick work or stone masonry surfaces in CM 1:4 finished even and smooth without using extra cement
M&L two coat of weather proof paint over a coat of primer including preparation of newly plaster surface over one coat of external putty
M&L 75 mm of thick PCC (1:3:6) type C-2 as in plinth protection
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
Plain or corrugated steel sheets, any thickness in available sizes, black
S&F powder coating anodised aluminium work for doors, windows, ventilators,grills with one or more rebates including joining cleat for fixing etc. including hinges omplete all as specified.
M&L 5.0 mm thick plain glass packing with rubber gasket, Al beading etc around both sides for fixing of glass all as specified and directed.
M&L for Anodised aluminium snap grid frame work for false ceiling with Perforated particle board/ tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid fiXed on slop/flat ceiling
M & L for Mild steel sheet eaves gutters, galvanised 1.25mm thick class 3, half round with rounded edges including fixing with flate iron bracke complete
M&L 75mm thick cement concrete type D-2, 1:4:8 all as directed.
M&L 25mm thick sand layer
M&L Machine pressed precast concrete interlocking paver block,coloured rubber moulded PU coated any shape and size 60mm thickness, M-35 Grade with
Chequered cement concrete tiles 25cmx25cmx25mm thick, set,jointed and pointed in neat cement slurry in floors.with grey cement and no pigment over and incl 15 mm screed in 1:6
Supply fixing and testing commissioning and errection of DHP medical grade pipe Solid drawn,semless,dioxidised, non-arsenical, half hard tempered and degreased, materials confirming to BS: 6017/1981 Table -2 (Cu-DHP) manufactured as per BS"2871/1971 part 1 Table X and dimension tolerance confirming to BS-EN 1057. pipe fitting confirm to BS -EN 12543: 1998 Make Janaya/Mexflow OF 12 X 0.7MM OD
All as per item Ser No 123 but 15 X 0.9 MM OD
All as per item Ser No 123 but 22 X 0.9 MM OD
Supply and fix Gas outlet points with probe parkotex type , copper stubs around 175 mm long ,12 mm OD copper pipe with colour coding - Make GL/M.R
Supply and fix Gas outlet points with probe parkodex type for Vacuum , copper stubs around 175 mm long ,12 mm OD copper pipe with colour coding - Make GHL/M.R
Supply and fix Isolation Valve with adapter Ball valve type working tem (-30 degree to 180 degree tempreture for 12MM OD pipe.. Make GHL/ M.R
All as per item Ser No 128 but For 15 MM OD pipe
All as per item Ser No 128 but For 22 MM OD pipe
Supply and fix BPC Flow meter with humidifier bottle and capacity 1 to 12 lpm with inlet pressure of 50 to 60 psi ,humidfire 250 CC polycarbonate body Make GHL/M.R
Supply and fix Ward suction unit with 600 ml jar Make GHL/M.R
Supply and fix Area Alarm System Digital display for two gas with sensor, digital display of gas pressure, high and low setting of audio-visual alarm Make GHL/M.R
Supply and fix Valve box with regulator with bypass system for two gas service GHL /MR
Supply and fix Wall mounted Bed Head Panel - 900 MM Long for of 02 nos oxygen outlet , 01 no medical vacuum outlet and 02 nos BS 15 Amp standard electric socket with double rail (Vertical) as per sample approved GHL/MR
Supply and fix for Electrical two Switch two socket plate complete modular type (LEGRAND)
Supply and fix Monitor Tray - wall mounted Make GHL/M.R
supply and fix Vacuum Slider Make GHL/M.R
supply and fix HP Tube for Oxygen/vacuum Make GHL/M.R
Supply and fix Oxygen Manifold System wall mounted straight line (4+4) With 8 tail Pipes ,NRV and Regulator singal Stage (with out cylenders ), pressure reating 145 kg /Sq.cm (make GHL/M.R
Supply and fix Semi-Automatic Gas control Panel for oxygen three valve outlet flow at 60 psi- 1000 LPM for oxygen with regulator hight pressure isolation valve and vent valve and bypass valve. Make GHL/M.R
Supply and fix (2Cyl ) Oxygen Manifold For Emergency With 2 tail Pipes ,NRV and Regulator Double Stage (with out cylenders) pressure rating 145 Kg/Sq.cm , wall mounting straight line
supply and fix Vacuum pump system oil free air compressor with 250ltr vacuum tank and 3 HP Motor Vacuum Switch , pressure reducing regulator, amf meter , volt meter, and within the system isolation valve and copper piping, etc. Vaccum pump make I.R/Crompton.
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of 2x4 sqmm + 1x4 sqmm earth wire in 20 mm dia conduit.
All as per item Ser No 144 but 2x6 sqmm + 1x6 sqmm earth wire in 25 mm dia conduit.
All as per item Ser No 144 but 2x10 sqmm + 1x10 sqmm earth wire in 25 mm dia conduit.
Supply and fix MCB distribution board SPN, 240 volts, 12 ways. Make - Legrand cat ref no 507611 or equivalent in Schneider or Hager as approved.
Supply and fix MCB distribution board TPN, 415 volts, 4 ways. Make - Legrand cat ref no 507670 or equivalent in Schneider or Hager as approved.
Supply and fix Single pole MCB 6 to 32 amp. Make - Legrand cat ref no 408587 to 408595 or equivalent in Schneider or Hager as approved.
Supply and fix Double pole MCB 40 to 63 amp. Make - Legrand cat ref no 408637 to 408639 or equivalent in Schneider or Hager as approved.
Supply and fix Four pole 40 to 63 amp. Make - Legrand cat ref no 408700 to 408702 or equivalent inSchneider or Hager as approved.
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 50 mm & inner pipe dia 25 mm duly filled with highly conductive and anti corrosive compound tested from NABL certified Laboratory of required quantity in ground by digging a bore of 100 mm dia surrounded by soil friendly backfill compound including connection with galvanised earth wire 4 mm dia from earth electrode to the equipment to be earthed duly protected in 15 mm medium grade GI pipe upto 7.5 m, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with PCC 1:2:4 type B-1, 40 mm thick cover with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 2.0 ohm complete.
Supply and fix Exhaust fan size 300 mm sweep totally enclosed highly efficient heavy duty motor with pressure dia cast aluminium rotor mounted on two ball bearing . Rigid frame with rubber mounting for scilent operation Make Crompton/Bajaj/Usha
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 5000 CuM per hour metal body alongwith making provn for fixing on window by providing MS angle of suitable size at any floor of building
Supply and fix Water heater storage type, electric, capacity 50 litres 2000 w
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping or conduit (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
S&F 20 amp, single pole and neutral, socket outlet, with 2 pole and earth, metal enclosed plug top in power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 16 amp as required. Make - Legrand cat ref no 607841 & 408592 or equivalent in Hager or Schneider as approved.
S&F Steel tubes ISI marked light grade galvanised with all fittings fixed to walls / poles / laid in road crossing etc as required of size 40 mm dia.
S&F modular switch one way 6 amp 1 module all as per Legrand Mylinc cat ref no. 675501 or equivalent in Schneider Zencelo or Crabtree Murano as approved.
S&F modular switch one way 16 amp 1 module all as per Legrand Mylinc cat ref no. 675511 or equivalent in Schneider Zencelo or Crabtree Murano as approved.
S&F modular switch two way 6 amp 1 module all as per Legrand Mylinc cat ref no. 675502 or equivalent in Schneider Zencelo or Crabtree Murano as approved.
S&F modular bell push, 6 amp, 1 module all as per Legrand Mylinc cat ref no. 675504 or equivalent in Schneider Zencelo or Crabtree Murano as approved.
S&F door bell, AC, 240 volts, single pole complete. Make - Havells Reo / Anchor Penta PC / SSK as approved.
S&F modular socket 6/16 - 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675555 or equivalent in Schneider Zencelo or Crabtree Murano as approved.
S&F modular socket 6 amp 2/3 pin combined 2 module all as per Legrand Mylinc cat ref no. 675550 or equivalent in Schneider Zencelo or Crabtree Murano as approved.
S&F modular hum free electronic step fan regulator, 100 watt 2 module all as per Legrand cat ref no. 675530 or equivalent in Schneider Zencelo or Crabtree Murano as approved.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including PVC casing-caping not less than 32x16 mm ISI marked ivory colour with all fittings / fixing accessories and sunken modular GI metal boxes not less than 1.0 mm thick and white modular mounting cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for one light point controlled by one switch.
All as per item No 167 but one fan point controlled by one switch.
All as per item No 167 but one socket outlet 6 amp controlled by one switch on the same board with other switches.
all as per item No 167 but One socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item Ser No 167 but One bell point controlled by one bell push.
All as per item Ser No 167 but one light point controlled by two, two way switches.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes not less than 1.0 mm thick and white modular mounting plates with frame for mounting modular switches, sockets as required for 3 pin 16 amps socket outlet point controlled by one switch.
S&F power unit for AC or geyser 3.5 KW 4 module including sunken modular GI metal boxes not less than 1.2 mm thick and white modular mounting plates with frame all as per Legrand Mylinc cat ref no. 675558, 689009, 675564 & 675584 or eqivalent in Schneider Zencelo or Crabtree Murano as approved.
Supplying and fixing in repairs LED batten (1.2 m) made of CRCA sheet housing with a PC glossy difusser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 19 watt (including driver) having colour temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. Make - Philips cat ref no. ENDURALED BATTEN "BN 108C LED 20S PSU CDL WH" or Bajaj cat ref no. BLTRU 20W WH VIVA or equivalent in other specified make as approved.
Supplying and fixing in repairs LED batten 9 watt, 900 lumens operating voltage 160 to 360 volts, colour temperature 6500K including connection all as per Philips Astra Line 9-Watt LED Batten or equivalent in Wipro or CG as approved.
Supplying and fixing in repairs LED bulkhead fitting 9 watt IP 66 & IK 09 with polycarbonate body duly prewired connection with 0.75 sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable all as per Philips cat ref no. WT202W LED6S CW PSU S2 PC or equivalent in other specified make as approved.
Taking down industrial plug and socket including one number single pole MCB any make, any capacity after disconnecting complete.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete.
Taking down carefully submain wiring with PVC casing caping / PVC surface conduit and making good disturbed surfaces complete.
Supplying, laying, testing and commissioning 1100 volts grade XLPE insulated & PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable laid in trenches / on pole / through pipe / fixed on wall of nominal cross sectional area 35 sqmm 3.5 core complete. Make - Havells / Polycab / Finolex / Universal as approved.
Excavation in soft / loose soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out complete for laying of XLPE cable.
Returning filling with earth obtained from excavation including spreading watering and consolidation in layers not exceeding 25 cms thick complete.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m above the starting point complete.
M&L for sand filling in trenches with clean dry fine river sand unwashed including gently punning around cables complete.
Supplying and laying old size bricks, common burnt clay building bricks sub class 'B' designation 75 laid in trenches over sand for cable protection complete.
Supply and fix Air curtain metal body, air velocity > 15 -17 m/s of size 121 x 30 cm. with sensor for automatic start stop.
Schedule of Credit
Satish kumar and company
J.J.ENGINEERING
UNIVERSAL INFRAPROJECT PVT LTD
Pioneer Enterprises
M/S Mohan Lal Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .