Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹36.6 L+₹4.7 L (14.7%)Rejected-Finance 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L2 | Rejected-Finance Other than Lowest bidder | |
| 3 | L3₹39.1 L+₹7.2 L (22.6%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest bidder | |
| 4 | L4₹40.0 L+₹8.1 L (25.3%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest bidder | |
| 5 | L5₹42.4 L+₹10.5 L (32.9%)Rejected-Finance 25 1 SIMRA P O KIDWAI NAGAR KANPUR UP 208011 | KANPUR | KANPUR | UP | 208011 | L5 | Rejected-Finance Other than Lowest bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
9 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur
COMPREHENSIVE MAINTENANCE AND ALLIED WORKS INCLUDING JOINERY ITEMS IN AGV COPLEX AT AF STN CHAKERI, KANPUR
2022_MES_546329_1
GE(AF)/CHK/T-29 OF 2022-23
Open Tender
Civil Works
Item Rate
300 days
GE (AF) B/R Chakeri
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹96,000
26 Sept 2022
20 Aug 2022
15 Sept 2022
20 Aug 2022
9 Sept 2022
3 Sept 2022
Amount
M & L for preparation of old treated wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Ditto all as per item No 1 above but applying on steel surfaces.
M & L for complete removal of previous treatment and preparation of old plastered surface of walls and applying two coat of oil bound distemper including 1-2 mm thick wall care putty over one coat of primer complete all as specified and directed
M & L preparation of old treated plastered or un-plastered surfaces of wall and applying one coat of oil bound distemper complete all as specified and directed .
Repairs to leaking water in bib taps, pillar taps, stop cocks, angle valve, PVC connection waste pipes, float valves, concealed stop cock, GI pipe joints, bottle traps etc. of any description by changing the washers etc. or any other minor accessories to make the system functional and if reapair by the spindel complete all as specified and directed. Note : Spindal sholuld be measured & paid separatley in relevent items of Sch 'A'.
Supply only brass spindal of any make complete all as specified and directed.
Removal of air lock / blockage of water in GI tubing 15 mm / 32mm / 50mm bore, cleaning the pipe or fittings etc and re-fixing in the same position complete all as specified and directed.
S & F in repair small fittings of galvanized iron medium grade such as socket, elbow, nipple or different sizes Tee, union reducer etc suitable for 15mm bore pipe complete all as specified and directed.
S & F stainless steel wire cloth of size 0.36 mm nominal dia of wire average width of aperture 1.40 mm fixed with stainless steel wire staples complete all as specified and directed.
S & F in repairs internal flushing kit of PVC low level flushing cistern of any capacity and making in functional complete all as specified and dircted.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L for 7 to 8 mm thick non-skid coloured ceramic tiles (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surfaces over and including 15 mm thick screed bed or bedding layer in CM (1:6) for laying floor finishes complete all as specified and directed.
M & L for 7 to 8 mm thick for glazed coloured ceramic tiles in vertical surfaces of size 300 mm x 450 mm or as required size at site in dado/skriting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM (1:4) on fair faces of brick work / concrete surfaces complete all as specified and dierected.
M & L for marble work 16 to 18 mm thick (table rubbed and polished ) as in cooking platform and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of any shade other than white and black over and including 15 mm Screed bed or bedding layer in CM (1:6) for laying floor finishes including rounding edges complete all as specified and directed.
M & L for 25 mm PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregates in sub base of floor complete all as specified and directed.
Dismantling of existing sunken treatment including plaster and M & L for water proofing treatment on existing sunken portion with the following specifications :- (a) 15 mm thick (average) plaster on sunken floor in CM (1:4) with waterproofing compound as per manufacturer instructions complete all as specified & directed. (b) M & L for providing two coat of master seal 550 or equivalent to prevent leakage/seepage through sunken floor over prepared surfaces complete all as specified and directed. (c) One spout of 40 mm dia GI Pipes Shall be provided in Sunken floor and sunken portion shall be filled with PCC (1:5:10) type E-2 using 40 mm graded brick aggregates complete all as specified and directed. Note- Only plan of the floor area shall be measured.
S & F 100 mm bore cast iron sanitary connection socket fixed to WC outlet etc complete all as specified and directed.
S & F in repair 15 mm bore steel tubing medium grade, galvanized with all fittings such as bend, elbow, socket, tees and fixed complete to wall or in floors including cutting, threading and making forged bends on pipes MS hooks in any position i.e concealed etc. complete all as specified and directed.
Cutting chases, pinnng in, in brick walls making good to facing where required and pointing in cement mortar (1:3) for concealed water tubing and crossing one side of wall to another side by cutting or drilling exceeding 10 cm but not exceeding 50 cm girth complete all as specified and directed.
S & F in repairs GI tubing 32 mm bore medium grade with all fittiings fixed to wall or laid in floor complete all as specified and directed (UPTO 12TH STOREY).
S & F in repairs GI tubing 32 mm bore medium grade with all fittiings fixed to wall or laid in floor complete all as specified and directed (UP TO 8TH STOREY).
S & F in repair gun metal globe or gate valve for 32 mm bore pipe with iron wheel and screwed both ends for iron pipes complete all as specified and directed.
S & F in repair gun metal globe or gate valve for 50 mm bore pipe with iron wheel and screwed both ends for iron pipes complete all as specified and directed.
S & F in repair PVC quoted MS drapery curtain rod fancy type having 20-25 mm bore with bracket and fancy type knob at both ends of each curtain rod, cut to length as required of any colour complete all as specified and directed.
Taking down cement plaster or cement lime plaster of any description on bricks or stone walls etc including raking out joints hacking for key scrubbing down with water etc. complete all as specified and directed.
M & L for 15 mm thick plaster in CM (1:6) surface finished even & smooth without using extra cement includding 1 mm (Average) thick wall care putty and applying two coats of OBD completed all as specified and directed.
M & L for rendering 5 mm thick plastering on ceiling in CM (1:3) finished even and smooth without using extra cement including 1 mm (average) thick wall care putty and applying two coats of OBD over puttied surface complete all as specified and directed.
S & F in repairs sinks made of stainless steel 1mm thick sheet kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495 mm x 420 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S & F in repair stainless steel wire cloth of size 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F in repairs 10 ltrs capacity PVC low level dual flush cistern with syphon handle lever, PVC bend including connecting to WC and fixing on walls with bracket complete all as specified and directed.
S & F in repair 100 mm bore cast iron spun pipe (centrifugally) in any length with or without ears with cement joints laid in trenches, floors or fixed to walls including making good to match with existing surface complete all as specified and directed. (Note-The rate quoted by the contractor shall deemed to be included upto 12th storey Height).
S & F in repair 100 mm bore dia cast iron branch pieces ( tee, bend, cross & 'Y' shapes & oval access doors with cement joint, fixed on walls complete all as specified and directed.
S & F in repair 3.5 mm thick sheet glass figured or plane as ordinary quality and glazing with oil putty or wooden beads in squares of any size complete all as specified and directed.
S & F in repair 15 mm dia stop valves (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repair vitreous China squatting pan, ‘Orissa’ pattern of size 580 mm x 440 mm white, with integral foot rests including connection to trap and to flushing pipe, anti-syphonage pipe, etc. including making good to floor excluding flushing cistern and flush pipes complete all as specified and directed.
S & F in repair vitreous china wash down water closet pedestal pan white excluding flushing cistern and flush pipes complete all as specified and directed.
S&F in repair 140 mm over all length of cover floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed.
S & F in repair 15mm dia bib taps, cast copper alloy, fancy type long shank, chromium plated with capstan, head screwed down, high pressure, screwed for iron pipe complete all as specified and directed.
S & F in repairs 15mm bore angle valves, cast copper alloy fancy type chromium plated with flange of cat No 7610 of Make- Prayag or equivalent in Cera/Essco complete all as specified and directed.
S & F in repair chromium plated shower rose fancy type of size 125 mm fixed to 15mm bore pipe complete all as specified and directed.
S & F in repair PVC connection 15mm size with PTMT nuts of length 600 mm long complete all as specified and directed.
S & F in repair 20 mm dia aluminium anodised tubular towel rail 'D' type 60 cm long between flanges complete all as specified and directed.
S & F in repair 15 mm bore pillar taps cast copper alloy fancy type chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shankes and fly nuts screwed for iron pipes complete all as specified and directed.
S & F in repair 15 mm bore stop valves cast copper alloy fancy type chromium plated screwed down high pressure with captain head screwed both ends for iron pipe or for union complete all as specified and directed.
S & F in repair 32 mm waste coupling of PTMT half or full threaded minimum wt 45 gm complete all as specified and directed.
S & F in repairs 40 mm bore CP waste coupling for steel sink complete all as specified and directed.
S & F in repairs PVC waste pipe 32/40 mm dia, 800 mm long complete all as specified and directed.
S & F in repair 125 mm / 150 mm dia PTMT grating with or without waste hole fixed on floor trap / nahni trap with white cement complete all as specified and directed.
S & F in repair vitreous china wash hand basin white round back of size 550mm x 400mm excluding taps, waste, chain & plug and porcelain stopper but including brackets complete all as specified and directed.
S & F in repair aluminium anodized barrel tower bolts of extruded section length of bolts 200 mm complete all as specified and directed.
Ditto all as per item no.49.00 here-in-before but for length of bolts 100 mm.
S & F in repairs extruded aluminium alloy handles fabricated type 150 mm size complete all as specified and directed.
Ditto all as per item no.51.00 here-in-before but for size 100 mm.
S & F in repair MS sliding door bolts 300 mm long bolt type stove enameled black with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts (four on bolt plate and two on staple plate) complete all as specified and directed.
S&F in repair rubber beading of size 75mm wide fixing with nail/screw, complete all as specified and directed.
Taking down shutter exceeding 1.0 Sqm but not exceeding 2.0 Sqm complete all as specified and directed.
M & L for 35 mm thick factory made Second class hardwood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc with sash bar any number fitted with cut and mitered beads for securing glass gauze etc , sizes of members of shutters as specified in SSR Part I section 8, Section 8.24(a) and fitted to chowkats complete all as specified and directed.
S&F 30 mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both sides complete, all as specified and directed.
S&F 100 mm size but hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F in mild steel helical door spring 150 mm ordinary rat tail type including roller and roller plate complete fixed with screws to wooden frames or with welding to steel frames complete all as specified and directed.
S&F 250mm long, mild steel sliding door bolt stove enameled black with bright bolt not less than 12 mm dia with and including minimum 6 bolts and nuts (four on bolt plate and two on staple plate complete) all as specified and directed.
S&F 150 mm long mild steel barel tower bolt stove enamelled black with bright bolt complete all as specified and directed.
S&F 125 mm MS pressed handle oval type stove enamelled black complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of newly wooden surfaces of any description exc. 10cm width or girth complete all as specified and directed.
Easing of door shutters for easy closing / opening tightening of hinges or changing the position of hinges adjustment of tower bolts, sliding bolts with new screws etc complete all as specified and directed.
Easing of window shutters, kitchen cupboard shutters, show case shutter drawers incl fixing of screws adjusting handles, knobs tightening piano hinges incl misc small adjustments complete all as specified and directed
M&L for cleaning of RCC water tank over and up to 9 to 12 storey building of AGV area having 35000 to 45000 ltr capacity including removal of all deposited scales, dirt and settled sand particals and cleaning with brushing, sweeping and brooming of inner wall (incl partition wall b/w the tank) of the tank and washing complete with bleaching powder solution and three coat of lime coating in inner wall and writing the date of cleaning with synthetic enamel paint on the tank complete all as specified and directed. (Note. (i) work shall be carried out with trained staff with hygeine and safety equipment. (ii) Sand, silt and other materials shall be thrown out side of MD land as per direction of Engr-in-Charge.
M&L for cleaning of RCC water tank over and up to 9 to 12 storey building of AGV area having 8000 to 12000 ltr capacity including removal of all deposited scales, dirt and settled sand particals and cleaning with brushing, sweeping and brooming of inner wall of the tank and washing the complete with bleaching powder solution and three coat of lime coating in inner wall and writing the date of cleaning with synthetic enamel paint on the tank etc complete all as specified and directed. (Note. (i) work shall be carried out with trained staff with hygeine and safety equipment. (ii). Sand, silt other material shall be thrown out side MD land as per direction of Engr-in-Charge.
Notes for Item No 1.00 to 69.00 : - (a) All items shall be executed/covered upto 12th storey height of AGV area. (b) All T&P, mask sanitiser, safety equipments and other items required at site under subject contract shall be provided by Contractor. Cost of temporary supports such as Props, Jacks, Scaffolding, Shuttering etc as up to 12th storey required for each individual case component wise is deemed to be included in unit rates quoted. (c) Adequate safety arrangement need to be ensured to avoid accidents / mishap & cost of same is deemed to be included in unit rates quoted. (d) The contractor shall employee adequate numbers of of tradesman / labour for timely completion of the complaint as per time frame given below :-(i) Priority-I : Complaints pertains to major water leaks, air locks, flushing cistern will be attended on priority-I and the same will be completed within 4 to 8 hrs. (ii) Priority-II : Complaints pertains to minor water leaks, reglazing of door and windows, easing of joinery will be attended on priority-II and the same to be completed within 48 hrs. (iii) Priority-III : Complaints pertains to water proofing of roof, repair of sunken slab, minor plaster work, re-flooring, replacement of joinery minor etc will be attended on priority-III and the same to be completed within one week. (iv) Priority-IV : Major plastering, reflooring, plinth ptotections, brick work etc will be attended on priority-IV and the same to be completed within one month. (v) Contractor or his supervisor shall collect the complaint/job card from JE concerned between 0900 hrs to 1000 hrs on all working days and deposited the same after completion of job duly signed by user/occupants. (vi) Summary of complaints will prepared by the contractor and put up to Engineer-in-Charge last date of every month. (vii) If contractor shall not attend the complaint as per time frame given in Para (i) to (iv), Rs 500/- per complaint will be recovered from the RAR/Final bill.
A.B.Enterprises
SHASHI CONTRACTORS
BVV ENTERPRISES
U.R ASSOCIATES
Chandra Construction Company
m/s sahu enterprises
DHARM ENTERPRISES
P.N. BROTHER
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .