| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.4 LAccepted-AOC KAMARAJ NAGAR AVADI CHENNAI TAMIL NADU | CHENNAI | CHENNAI | TAMIL NADU | 600071 | ₹79.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹83.4 LRejected-AOC | ₹83.4 L | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | M Karthik L1 | THILLAI NATARAJA ROAD CONSTRUCTIONS P LTD L2 |
|---|---|---|---|---|---|
| 1.00Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. | |||||
| 1.10 | Footings - First Depth - 2.00m | 124 | cum | 282 ₹34,968 | 296 ₹36,704 |
| 1.20 | Footings - Second Depth - 2.00m to 3.00m depth | 42 | cum | 556 ₹23,352 | 583 ₹24,486 |
| 1.30 | Plinth Beams | 15 | cum | 122 ₹1,830 | 129 ₹1,935 |
| 2.00 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 11 | cum | 1,876 ₹20,636 | 1,970 ₹21,670 |
| 3.00 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means | 11 | cum | 5,753 ₹63,283 | 6,040 ₹66,440 |
| 4.00 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation - Plain Surfaces Below GL | 107 | sqm | 574 ₹61,418 | 602 ₹64,414 |
| 5.00Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. - For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. | |||||
| 5.10 | Plain Surfaces 3.00m to 4.30m | 83 | sqm | 1,017 ₹84,411 | 1,067 ₹88,561 |
| 5.20 | Plain Surfaces at 7.30m to 8.30m | 69 | sqm | 1,154 ₹79,626 | 1,211 ₹83,559 |
Tender Value
₹96 L
EMD Value
₹96,000
Closing Date
2 Mar 2026, 3:00 pmClosed
THE COMMISSIONER
THIRUNINDRAVUR MUNICIPALITY
Construction of 2.00 LL Capacity OHT with Pump room at Prakash Nagar Ward No.09 in Thirunindravur Municipality
2026_MAWS_664999_1
70/2026/E1
Open Tender
Civil Works
THIRUNINDRAVUR MUNICIPALITY
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹96,000
THIRUNINDRAVUR MUNICIPALITY
30 Apr 2026
23 Feb 2026
2 Mar 2026
23 Feb 2026
2 Mar 2026
23 Feb 2026
24 Feb 2026
Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers.
Footings - First Depth - 2.00m
Footings - Second Depth - 2.00m to 3.00m depth
Plinth Beams
Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation - Plain Surfaces Below GL
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. - For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
Plain Surfaces 3.00m to 4.30m
Plain Surfaces at 7.30m to 8.30m
Plain Surfaces at 11.30m to 12.30m
Plain Surfaces at 15.30m to 16.30m
Plain surfaces - 19.30 to 20.30m
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
Square Column upto 3.30m
Square Column 3.30m to 4.30m
Square Column 4.30m to 5.30m
Square Column 5.30m to 6.30m
Square Column 6.30m to 7.30m
Square Column 7.30m to 8.30m
Square Column 8.30m to 9.30m
Square Column 9.30m to 10.30m
Square Column 10.30m to 11.30m
Square Column 11.30m to 12.30m
Square Column 12.30m to 13.30m
Square Column 13.30m to 14.30m
Square Column 14.30m to 15.30m
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. - For Curved surfaces such as RCC floor slab, roof slab, beams, etc.
Curved Surface 16.30m to 17.30m
Curved Surfaces 17.30m to 18.30
Curved Surfaces 18.30m to 19.30
Curved Surfaces 19.30m to 20.30
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - For Circular surfaces such as Circular RCC columns etc.
Circular Column upto 3.30m
Circular Column 3.30m to 4.30m
Circular Column 4.30m to 5.30m
Circular Column 5.30m to 6.30m
Circular Column 6.30m to 7.30m
Circular Column 7.30m to 8.30m
Circular Column 8.30m to 9.30m
Circular Column 9.30m to 10.30m
Circular Column 10.30m to 11.30m
Circular Column 11.30m to 12.30m
Circular Column 12.30m to 13.30m
Circular Column 13.30m to 14.30m
Circular Column 14.30m to 15.30m
Providing and laying in position Standardised Concrete Mix M-25 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 350Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards.
For 1.5m Below G.L
For 4.5m Above G.L
For 4.51m to 7.32m Above G.L
For 7.32m to 10.98m Above G.L
For 10.98m to 14.64m from G.L
Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M -Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requirements of IS standards.
For 14.64m to 18.30m from G.L
For 18.30m to 21.96m from G.L
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
Supply and fabrication of steel required for all RCC items of works involved in the schedule, cost of steel at site fabrication, labour charges for cleaning the rods straightening, cutting, bending, tying grills, including overlapping to the required length whenever necessary and placing the reinforcement in position as as per design given and specified in the drawings, including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc complete as per standard specification
Fly ash Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using Fly ash brick (230 x 110 x 70mm) including finishing, curing, etc., complete complying with standard specification - 100CFT
Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications
Painting two coats of newly plastered wall surface with approved cement paint over cement plastered wall surface, ceiling and including preparing the surface, clean removal of dirt and including necessary plaster of paris putty wherever required and cost of painting materials, brushes, preparation of surfaces and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officer
Supplying and fixing in position C.I.Manhole covers (light or heavy duty) of 600mm X 600mm sizes of best approved quality and as per standard specifications etc.,complete.
Providing and fixing of RCC inner access ladder in RCC M20 Grade Concrete Mix as per the standard specifications for OHT including grill in position, centering, shuttering charges, mixing concrete curing etc, to required height and clear width of 45cm consisting of two nos of vertical post of 10cm X 15cm and step salb of 25mm X 25mm etc,complete and as directed by Municipal Officers.
Construction of RCC spiral staircase in RCC M20 Grade Concrete Mix as per the standard specifications of 1.80 m diameter of 20m height for approach to the roof of Service Reservoir with RCC Handrails including earthwork excavation, providing CC 1:4:8 mix, RCC footing 1:1.5:3 mix, GL platform etc., and also including cost of steel reinforcement, fabrication charges, scaffolding, centering, precasting charges, cement, painting etc. complete as per standard specifications and as directed by Engineer. The staircase shall be braced to the column of service reservoir at suitable interval. (in the BOQ, quantity column the exact height to be mentioned from GL to roof slab bottom to get total value of work to be done.
Supplying and fixing of RCC M20 Grade Concrete Mix as per the standard specifications for RCC Handrails of 0.91 m height over the top of roof slab of approved pattern and design including the cost of reinforcement, centering, precasting, finishing, curing etc., complete as per standard specifications and as directed by Engineer-in-charge
Providing and fixing of M20 Grade Concrete Mix as per the standard specifications for ventilators of approved pattern including cost of cement, reinforcement, centering, shuttering, strutting etc., complete as generally shown in plan and as directed.
Supply and delivery of CI D/F sluice valves with cap along with specials of the 150mm dia in size confirming to IS 14846 / 2000 (PN1) including flanged tail piece and other specials as required, loading, unloading, transportation charges and stacking and jointing including cost of jointing materials etc, complete as per standard Specification. As per TWAD SOR 2024-25, Page No. 57
Constructing masonry chamber of inside dimensions as mentioned below with Country Brick, brick work in CM 1:5 (1 cement : 5 coarse sand) for sluice valve, with CI Surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and top RCC Precast slab 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20mm nominal size) with necessary earth work excavation including refilling the sides of foundation, foundation concrete 1:5:10 (1 cement : 5 coarse sand : 10 grade stone aggregate 40mm nominal size) and inside plastering with CM 1:5 (1 cement : 5 coarse sand) 12mm thick finished with a floating coat of neat cement, complete as per standard design and shown in the drawings. 1500x 900x1200mm clear inside dimensions
For Sluice Valve - 150mm dia
For Sluice Valve - 250mm dia
Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 150 mm/200mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs fuel, labour and drilling bentonite and water required for drilling at site. Site will be shown by the TWAD Board officers including construction of mud pit. A
Upto 60 mt. Depth ending below ground level
Reaming 200 mm dia pilot bore to 350mm dia bore as directed by the Departmental Officer
Upto 60 mt. Depth ending below ground level
Supply of the following casing pipes of ISI approved quality with wall thickness not less than 7.5mm to 8.5mm with PVC couplers and cement Paste etc. Complete and including packing the annular space with pebbles quality and size of pebbles and the PVC pipe should be approved by the departmental officer.
200mm dia OD PVC Plain casing Pipe (RS)
150mm dia OD PVC casing Pipe (RS)
Labour Charges for inserting PVC Casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC Couplers with Cement paste etc., complete supply and packing the annular space with pebbles of size and quality as approved by the executive engineers
Charges for developing the borewell with air compressor of 600 cfm capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board officers and conducting yield test by 'V' notch method.
supply and delivery of 7.50HP Single phase Submersible pumpset of duty condition 250lpm x 125m as per IS 8034 without panel board etc complete as per standard specification.
Supply of Single phase Pannel board suitable for 7.50 HP with two level guard and auto start etc complete as per standard specification.
Supply and delivery of Flat cable suitable for submersible pumpset 6sq.mm
Labour charges for the errection of 7.50 HP submersible pumpset in the Borewell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth walls errection clamps pressure gauges up to the exterior wall of pumping room and errection of panel board consisting of DPICN switches starter volt meter ammeter, Three Pilot ( Indicating ) lamps capacitor single phasing preventer water level guard and laying and jointing the cable s and twin earthing as per IE rules etc complete and testing to the pumpset and trial run for 10 Days.
Supplying and fixing of pipe and accessories ISI make including cutting and threading cost and conveyance of all charges etc complete as per standard specification.
UPVC 65mm pipe PWD Schedule of rates
Providing and fixing in position of PVC water bar 150mm wide with single bulb for horizontal joints necessary holders fabrication, the rate inclusive of cost of water bar, holders fabrication and fixing in position etc complete as per standard specification and as directed by the Engineer. As per TWAD SOR 2024-25, Page No. 74
Supplying, Laying, jointing of following DI specials of as per IS:9523-2000 with D.I pipes etc., complete as directed by the Engineer, and Provision for pipe connection arrangements for inlet, outlet, scour and overflow etc, including cost of pipes, specials, valve, labour charges for lifting, aligning, fixing of DI pipes etc, complete. As per TWAD SOR 2024- 25, Page No. 40
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Tendernotice_2.pdf
PDF • 0.88 MB
BOQ_798642.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid