Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 CrAccepted-Finance | ₹7.0 Cr | L1 | Accepted-Finance Accepted |
Tender Value
₹6.0 Cr
EMD Value
₹12.1 L
Closing Date
27 Dec 2024, 2:30 pmClosed
Executive Engineer, PWD, WD-II, Diu
Executive Engineer, PWD, WD-II, Fort Road, Diu
Restoration, Re-Development, Planning and Designing of Old Govt. Hospital into a Heritage Structure - Diu. (Civil, MEP, HVAC, Horticulture Works) (2nd Call)
2024_DIUDT_3891_1
e-Tender Notice No. 27/2024-25
Open Tender
Civil Works - Others
Works
365 days
Diu
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
Executive Engineer, PWD, WD-II, Diu
₹12.1 L
Executive Engineer, PWD, WD-II, Diu
4 Jan 2025
12 Dec 2024
27 Dec 2024
12 Dec 2024
27 Dec 2024
12 Dec 2024
20 Dec 2024
Amount
Works
SUB HEAD 1- DISMANTALING AND DEMOLISHING WORK : Demolition of Cement concrete and disposal of unserviceable materials within 50 metres lead.
Demolition including stacking of serviceable materil as and disposal of unserviceable materials with all lead and lift. (i) R.C.C. work
Demolition and disposal of unserviceable materials with all lead and lift. (i) Lime concrete.
Demolition of Brickwork and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift. (ii) In Cement Mortar.
Dismantling doors, windows, ventilators etc. (wood or steel) shutters including chowkhats architraves, holdfasts and other attachement etc. Not exceeding 3 Sq.m in area complete and stacking them within 50 metres lead as per direction of Engineerin-charge.
Dismantling doors, windows, ventilators etc. (wood or steel) shutters including chowkhats architraves, holdfasts and other attachement etc., exceeding 3 Sq.m in area complete and stacking them within 50 metres lead as per direction of Engineer-in-charge.
Dismantling wood work, wrought framed and fixed in framed trusses including stacking the materials within 50 metres lead as per direction of Engineerin-charge.
Dismantling steel work including segregating and stacking the materials within 50 metres lead as per direction of Engineer-in-charge.
Dismentaling tiled of stone floors laid in mortar including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.
Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc. stacking of serviceable materilas and disposal of unserviceable materials within 50 metres lead.(i) A.C.sheet roofing.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
SUB HEAD 2- PREPARATORY WORK : Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia. M.S. tube 1.5 m center to center, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.
Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4M. and removal of the same for in situ reinforced concrete and plain concrete workin. (A) Foundations Footings Bases of Columns etc. and Mass concrete.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4M. and removal of the same for insitu reinforced concrete and plain concrete work in. (C) Vertical surface such as walls (anythickness) partitions and the like including attached buttresses & stringcourse & the like.
Providing formwork of ordinary timber planking so as to give a rough finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4M. and removal of the same for insitu reinforced concrete and plain concrete work in. (H) (2) Sides and soffits of Beams Beam Haunchings cantlevers Girders Bressumer sand Lintels exceeding 1M. in Depth.
Providing formwork of ordinary timber planking with new plywood so as to give a rough finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in situ reinforced concrete and plain concrete work as per directions of Engineer In charge.( Slabs )
Extra for additional height of propping and centering where the height of propping and centering exceeds 4 .0 M between supporting floor to ceiling including temporary brick or stone pillars for supporting as required. (i)Height more than 4.0 M.and upto 5.0 M.
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.O M between supporting floor to ceiling including temporary brick or stone pillars for supporting as required. (ii) Height more than 5.0 M.and upto 6.0 M.
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.O M between supporting floor to ceiling including temporary brick or stone pillars for supporting as required. (iii) Height more than 6.0 M. and upto 7.0 M
SUB HEAD 3- STRUCTURAL REPAIRS : Providing & Grouting cracks in lime mortar 1:1:1 (1 lime:1 lime stone dust : 1 coarse sand) with adding natural adhesives (glues) i.e. Jaggery syrup, neem glue, shesh gundar etc. by drilling holes along with the cracks (12mm) in zig-zag pattern inserting aluminum nipples in the same and applying gravity grouting with the lime mortar using funnel and plastic pipes all complete as directed by the EIC.
Providing Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 liters per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm center to center and sealing the same as directed by the engineer in charge.
Carrying out wall treatment for termite control including spraying with chemical solution in oil base including labour and material Using Chlorpyriphos 20 ECAs per IS 6313 part - II (1% concentration by mass) is recommended i.e one litre chemical emulsion diluted with 19 liter oil base. Total solution will be 20 liters inclusive of one liter chemical emulsion application at the rate of 7.5 litre chemical / Sqm of surface is recommended as per I.S.
Providing and Laying Damp-proof-course by 150mm groove in existing wall and fixing brittle stone/marble in groovebelow finish floor level as per direction of Engineer-in-charge.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
SUB HEAD 4 - CIVIL WORKS : Providing & Applying Lime Plaster: Providing & Applying (Decorative/ ornamental) 25mm lime plaster in three coats having Backing coat of thickness 12mm on bela stone masonary walls using lime, coarse sand, stone dust and adhesives as per traditional practice, mortar mix of 1:1.5:2:0.5 (1 lime, 1.5 coarse sand, 2 stone dust,0.5 coarse chirodi) and appropriate adhesives i.e. jaggery syrup, methi powder, yellow oxide, geru powder,dolomite (marble powder) etc. as binders, colour pigments, insecticide and fungicide and second coat having thickness 10mm lime plaster (cushioning coat) on backing coat using lime, coarse sand, stone dust and adhesives as per traditional practice, mortar mix of 1:1.5:2:0.5 (1 lime, 1.5 fine sand, 2 stone dust,0.5 fine chirodi) and appropriate adhesives i.e. jaggery syrup, methi powder,dolomite (marble powder) etc. as binders, insecticide and fungicide with third coat of 3mm lime punning (Render coat) on bela stone masonary walls using lime, coarse sand, stone dust and adhesives as per traditional practice, mortar mix of 1:1.5:0.5 (1 lime, 1.5 stone dust, 0.5 fine chirodi) and appropriate adhesives i.e. jaggery syrup, methi powder, dolomite (marble powder) etc. as binders, insecticide and fungicide. Applying lime plaster incl. curing, consolidation, finishing complete with all materials, labour, tools and tackels. as directed as Engineer- in- Charge
Providing and finishing of Lime punning render coat of minimum 4mm thick on lime stone surface for both plain and decorative/ covered on the main façade in Lime Mortar 1:1.5:0.5 (1 lime, 1.5 stone dust, 0.5 fine chirodi) (inclusive of coloring pigment as required) Rates are including modification factor and shall be paid on plan area as per the direction of Engineer-in-Charge.
Application of High quality Wacker SMK 1311 water base water repellent solvent free silicon coating impregnating on all Internal & external wall surfaces. The dilution of water should be done in ratio of 1:10 (1 Wacker : 10 water). The dilution should be applied in 2 more coats, wet on wet application to the surface. The application can be made through brush. The application should be done with prior preparation of surface by cleaning o it form residue of any material, dusting it clean for application.
Providing and applying of Permeable, water based Mature Lime wash finish of interior and exterior grade used for conservation and restoration of historical building, formulated by Mature Lime Putty with fillers, After the cleaning of surface and removing any loose or flaking material, applied two coat of Lime wash finish with one coat of Lime Based primer of approved color and shade to achieve desired finish apply by brush, roller and appropriate tools, as per specification, all completes with the direction of Engineer-in-Charge and Architect. Internal and external surface
Providing and repairing of Plastic / mortar Repairs (in ornamental / decorative work in stone or raised stucco motifs / ornamental features, like figurative forms urns, cornices, mouldings, finials etc ) using lime based mortars that is compatible with the host substrate (to provide an effective bond) shall be used. Profiled plastic repair for retention of carved enrichments using anchoring armatures of non-ferrous metals / any other as existing in host substrate and color matching using traditional techniques etc in (1:1 / 1:2) 10% pozzolonic lime mortar with additives etc complete.
Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure above plinth level upto floor two level in cement mortar 1:5 ( 1 cement : 5 fine sand ) complete as per Technical Specification
White bela stone masonry block in course in super structure with stone of approved quality in lime mortar 1:1.5 ( 1 lime : 1.5 Fine Sand) including packing the joints complete etc as per direction of Engineer In Charge as per direction of Engineer In Charge
Providing & Laying 50mm thk. Lime stone slab flooring over the wooden roof incl. joint filling complete up to floor V lvl. Inculding erection of scoffolding & props also.
Providing & Applying Lime concrete: Providing & Applying 50-75mm lime concrete on vaults using lime, sand, stone dust, coarse aggregate and adhesives as per traditional practice, mortar mix of 2:1:1:1:0.5 (2 lime, 1 sand, 1 Dolomite, 1 Stone dust, 0.5 coarse aggregate) and appropriate adhesives i.e. jaggery syrup, methi powder, yellow oxide, geru powder, dolomite (marble powder) etc. as binders, colour pigments, insecticide and fungicide. Applying lime plaster incl. curing, consolidation, finishing complete with all materials, labour, tools and tackels.
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of single or half brick walls for interior plastering upto floor two level and finished even and smooth in (i) Cement mortar 1 :3 (1-cement:3-sand). (Internal surface)
Providing and laying controlled cement concrete M.150 for curing complete excluding cost of formwork and reinforcement for reinforced concrete work in (A) Foundations , footings, Base of columns and Mass concrete
Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and reinforcement for reinforced concrete work in (D) Columns, Pillars posts and struts, upto floor two level.
Providing TMT Bar FE 500D reinforcement for R.C.C work including bending, binding and placing in position complete. ( Upto 10 ton)
Providing anticorrosive treatment to Fe 500D bars with FUSION BONDED EPOXY COATING (FBEC) confirming to IS13620:1993 at approved plant including testing of coating as per relevant IS, before bringing the coated bars on site including To & Fro transportation of bars for sending at plant site etc. complete, for FE 500D bars : Up to 28 mm dia.
Providing and fixing chicken wire mesh 145 gsm 200 mm wide along the joints of brick work with mortar & above PVC Conduit Lines. complete so as to receiving the plastering work over chicken mesh as per the direction of Engineer‐in‐charge direction of Engineer‐in‐charge.
Providing and fixing Cast Iron railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge
Providing and fixing Gypsum board false ceiling 12 mm Thick complete with all hardware fitting including screw as per design complete as per directed by EIC.
Providing and fixing MDF 18mm sheet false ceiling complete with all hardware fitting including screw and wooden primer finish as per directed by engineer in charge.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Providing and fixing 8 Passenger elevator with 2 stops with machine room as per specification - 282 - KONE A MiniSpace R22.2-2 complete as per directed by Engineer in charge
Dismentaling stone from steps and replace it with Rajula sand stone as per given shape and size as directed by engineer in charge.
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(B) Dense or Hard soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(B) Dense or Hard soil
Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
SUB HEAD 5 - WOOD WORKS : Providing and fixing new timber frames upto 75mm thick with well class A Indian well seasoned teak wood (Nagpur teak, CP teak, Valsadi teak or equivalent) well-seasoned, chemical treated Door/Window frames made to size, shape and design as per original design, size and pattern including and fixed in position with hold fast (40x5-40 cm) long lugs or with dash fasteners of required dia & length etc complete as per direction of Engineer In Charge.
Providing and fixing new timber door/window shutters with well-seasoned class A Indian teak wood ( Nagpur teak, CP Teak, Valasadi or equivalent) chemically treated Door/Window shutters as per original design, size and pattern including all necessary hardware fittings like brass Parliament Hinges of 10 cms length with pins (door), Brass tower bolt (barrel type) of minimum 250x10 mm in size, Aldrop 20mm. dia Size with necessary fitting Brass of minimum 30cms. Length & Brass Extruded Handle for doors of minimum 15 cms. Length etc. including with 3mm thick irani coloured glass for glazing complete. as per direction of Engineer In Charge.
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) Detail of cost for 10 sqm MATERIAL 7241 Melamine Matt clear polish litre 1.56 300.00 468.00 Code Description Unit
Painting (one or more coats) with black japan paint of approved brand and manufacture to give an even shade.
Providing and fixing the Facia Eaves board on wooden sloping roof in a decorative manner made up 25 mm x 250 mm size of Teak wood including all neccessary fixtures & fastenings and finish with oil based paint and complete as per the drawing and as per the direction of Engineer-in-Charge.
Providing and fixing Well seasoned Indian teak wood full length new members like joists, rafters, purlins, etc. including all fixtures and fastenings with one coat of primer etc. complete. Item to include all mouldings and chamfers to be made as per original design indicated by the Architects, Item to include using a larger section of wood to get the mouldings and chamfers as per original design, sample to be shown to the Architect for approval before fixing. Item to also include application of solignum on the wooden surface.
Providing and fixing new wooden beams in roofs with well-seasoned class A Indian teak wood (Nagpur teak, CP Teak, Valsadi or equivalent) including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to the dumping ground not exceeding 4.00 meters in length., all complete as per direction of Engineer-in-Charge.
Providing & Fixing heritage type circular wooden railing having 3" Dia is tobe fitted with brass coupler with well-seasoned class A Indian teak wood ( Nagpur teak, CP Teak, Valasadi or equivalent) to be finished with wallnut french polish and protection coat against weather to be mounted on exsisting wall as per design and directed by EIC.
Providing and fixing sandwich Glass consisting combined toughen glass 5mm thick and irani glass 3mm thick to be mounted with rubber gasket in the 9" thick galvanized MS frame to be approved before installing by of Engineer-in-charge. Inclusive all hardware ( screw, sillicon etc.) and fittings.
Providing and fixing Irani Glass 3mm thick with appropriate design and colour Inclusive all hardware and fittings. Complete as per directed by EIC
SUB HEAD 6 - FLOORING WORKS : Providing and fixing 8" x 8" moroccan tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring and Dado on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)
Providing and laying tiles 600 x 600 flooring including wastage in required design and patterns, in linear as well as curvilinear portions of building all complete as per artichitectural grawings with over 20mm thick base of cement mortar 1:4 (1-cement : 4-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. as per the direction of Engineer-in-Charge.
Providing and fixing kota shelf of 5 rack of width of 0.75 mtr with all material, complete as per directed by EIC.
Providing and fixing granite platform of 0.75m width with edge moulding to 18 mm thick granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc, Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete as per design approved by Engineer-in-Charge.
Providing and fixing wooden deck flooring as per given detail and drg complete with melamine polish as per instructed by engineer in charge.
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately), Lime Stone 70mm thick
SUB HEAD 7 - WATERPROOFING WORKS : Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.7 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approve by Engineer-in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge. d) Finishing the surface with 20 mm thick joint less cement mortar of mix 1:4 (1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fiber cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying broken chine mosaic flooring for terrace using 12 mm to 20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain or slope and to be tempered to bring mortar creme out upto surface using white cement including rounding off junctions and extending them upto 15 cm along the wall, clearing with water and oxalic acid etc. as directed.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and erecting water cooler having storage capacity 80Ltr. & cooling capacity 40 Ltr.per hour @ an ambient temp of 45˚ C. The outlet temp. of the water should drop by 15˚ C within a hour, The water cooler should be comprising of hermetically sealed compressor, fan motor, condensing unit, water tank surrounded by evaporating coil, thermostats, relay etc. complete with necessary inlet & outlet connection. The body of water cooler will be made from Stainless Steel. ◦
Supply, checking, storing & fixing CP Over Head Rain shower MODEL:JAQUAR-OHS-35497 or equivalent complete as per instructions of the engineer-in-charge.
Supply, checking, storing & fixing CP single lever wall mixer MODEL:K-72290IN-4FP-CP or equivalent with Concealed body Shower Valve & Bath spout K-99061IN-CP complete as per instructions of the engineer-in-charge.
Supplying & erecting reverse osmosis (RO) water purification system with M.S. powder coated pedestal frame, prefilter housing carbon filter suitable buster DC pump, auto low & high pressure switches with following size of LPH capacity & erected as directed with one year comprehensive maintenance guarantee. [D] 100 LPH with 3 phase Raw water pump of 500LPH @ 2.5kg/cm2 - (1N0 - Kirloskar /CRI/Lubi), Dual media filter 10"x54" - (1 No), Micron cartridge filter 20" x 2.5" ( 1No), High pressure pump 500LPH @ 10kg/cm2 - (1No - Shimge /CRI /Lubi), RO Membrane housing with RO membrane of 40*40 - (1No), RO pressure tube 4" x 1E - ( 1No), 0 - 1200LPH Rotameter -(2 Nos), with Recovery Rate 50%.
Soil Waster and Vent Pipe : Supply,Installation,testing and commissioning of Silent soil & waste pipes of PP(Polypropylene) material As per EN 12056 with Min. density 1.2 g/cm3 with mineral wool (for noise reduction) with push fit lock seal joints, with necessary fittings such as making proper connections to equipments including all necessary fittings and specials such as bends, tees, reducers,,Wye , Door tee , Vent cowl,Access pipe for claening in required interval(on service floor & basement) ,nuts,bolts,gaskets,supports and plugs etc. Fixing at wall/ ceiling level supported by clamps, fire collars,expansion joints,Y branches, hangers etc. as per the specification,drawings and schematics. All hangers, clamps, brackets,anchor/fixed support,guides,rollers etc. shall be of galvanized iron unless specified otherwise and then supply and installation of the same shall also be excluded for rates under this head. Welding of any kind on the galvanized support / hanger shall not be permitted.(The pipe length inserted in the fitting shall not be measured for payment) (Pipes for soil , waste for internal toilet & Shaft).40 mm
Supply,Installation,testing and commissioning of Silent soil & waste pipes of PP(Polypropylene) material As per EN 12056 with Min. density 1.2 g/cm3 with mineral wool (for noise reduction) with push fit lock seal joints, with necessary fittings such as making proper connections to equipments including all necessary fittings and specials such as bends, tees, reducers,,Wye , Door tee , Vent cowl,Access pipe for claening in required interval(on service floor & basement) ,nuts,bolts,gaskets,supports and plugs etc. Fixing at wall/ ceiling level supported by clamps, fire collars,expansion joints,Y branches, hangers etc. as per the specification,drawings and schematics. All hangers, clamps, brackets,anchor/fixed support,guides,rollers etc. shall be of galvanized iron unless specified otherwise and then supply and installation of the same shall also be excluded for rates under this head. Welding of any kind on the galvanized support / hanger shall not be permitted.(The pipe length inserted in the fitting shall not be measured for payment) (Pipes for soil , waste for internal toilet & Shaft). 75 mm
Supply,Installation,testing and commissioning of Silent soil & waste pipes of PP(Polypropylene) material As per EN 12056 with Min. density 1.2 g/cm3 with mineral wool (for noise reduction) with push fit lock seal joints, with necessary fittings such as making proper connections to equipments including all necessary fittings and specials such as bends, tees, reducers,,Wye , Door tee , Vent cowl,Access pipe for claening in required interval(on service floor & basement) ,nuts,bolts,gaskets,supports and plugs etc. Fixing at wall/ ceiling level supported by clamps, fire collars,expansion joints,Y branches, hangers etc. as per the specification,drawings and schematics. All hangers, clamps, brackets,anchor/fixed support,guides,rollers etc. shall be of galvanized iron unless specified otherwise and then supply and installation of the same shall also be excluded for rates under this head. Welding of any kind on the galvanized support / hanger shall not be permitted.(The pipe length inserted in the fitting shall not be measured for payment) (Pipes for soil , waste for internal toilet & Shaft).110 mm
Providing, laying and jointing in true line and level 160 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 160 mm diametre x 210 mm length x 196 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
Supply , installation , testing and commissioning Polyproplene (PP) 110mm x 110mm size P trap (Floor trap) of self cleaning design with Min. 50mm water seal with and without vent arm jointing with push fit rubber ring socket fittings complete, cutting chases / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position in case of suspended / open plumbing or setting the trap in 1:2:4 CC in case of concealed plumbing , etc. complete, as required. The trap shall be of following sizes: Temporary airtight PVC cover to be provided to prevent dirt entry.
Supply , installation , testing and commissioning Polyproplene (PP) 110mm x 75mm size Multi floor trap/Height riser of self cleaning design with Min. 50mm water seal with and without vent arm jointing with push fit rubber ring socket fittings complete, cutting chases / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position in case of suspended / open plumbing or setting the trap in 1:2:4 CC in case of concealed plumbing , etc. complete, as required. The trap shall be of following sizes: Temporary airtight PVC cover to be provided to prevent dirt entry. ( In sahft )
Internal Water Supply : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 20 mm dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 25 mm dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 32 mm dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 40 mm dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic) (Inside Toilet)(Make:Astral,Ashirvad,Finolex) 50 mm dia Pipes ( SDR 11 )
Providing, fixing, jointing and testing in position the following U-PVC pressure threaded Pipes as per ASTM D 1785 Schedule 80 and threaded conforming to IS:554. Cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. The pipes & fittings shall be tested to a pressure of 15 Kg/Sq.cm. Fixing at wall/ ceiling level supported by clamps, fastener, hangers etc. as per specification. Cutting hole in wall / floor slab and making good the same with cement concrete 1:2:4 complete as required. GI heavy class pipe sleeve of larger diameter shall be provided wherever the pipes crossing the walls/floor slab and sealing the sleeves as per consultants requirement. Threading, jointing & making proper connections & as per provided drawings by architect,techincal specification and as directed by the authority EIC.(Water Supply Riser & Main Ring) (make:Astral,Ashirvad & supreme) 65mm dia
Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finsh with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect.(Make:Sant,Zoloto,leader) 32mm dia
Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finsh with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect.(Make:Sant,Zoloto,leader) 40mm dia
Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finsh with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect.(Make:Sant,Zoloto,leader) 50mm dia
Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.(Make:Sant,Zoloto,leader) BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 65 mm dia.
External Water Supply,Drainage ,Strom Water & Pumps : Providing and laying in trenches 10.0 Kg. F/Cm2 working pressure I.S.I. mark PVC SWR pipe of 200 mm dia low density pipe of make PRINCE / SUPREME / ASTRAL / FINOLEX as approved by Engineer In Charge including fitting etc completein ground.
Providing and laying in trenches 10.0 Kg. F/Cm2 working pressure I.S.I. mark PVC SWR pipe of 250 mm dia low density pipe of make PRINCE / SUPREME / ASTRAL / FINOLEX as approved by Engineer In Charge including fitting etc completein ground.
Providing and Laying Underground drainage System Foam Core SN8 pipe complete with all fittings excavation of trench 0.7m wide and depth varying from 0.75m to 2.4m , and refilling the same after laying of drain and concrete encasement in concrete 1:3:6 grade concrete with minimum thickness of encasement 100m thk & as per provided drawings by architect,techincal specification and as directed by the authority EIC.(Make:Supreme,Astral or equivalent ) 150 mm dia
Providing and Laying Underground drainage System Foam Core SN8 pipe complete with all fittings excavation of trench 0.7m wide and depth varying from 0.75m to 2.4m , and refilling the same after laying of drain and concrete encasement in concrete 1:3:6 grade concrete with minimum thickness of encasement 100m thk & as per provided drawings by architect,techincal specification and as directed by the authority EIC.(Make:Supreme,Astral or equivalent ) 200 mm dia
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mmx300mm size (inside) with standard weight.(i)Square mouth traps.(B)150mm x 100mm size P or R type
Constructing manhole with R.C.C top slab in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrte 1:3:6 mix (1 cement : 3 coarse sand : 6 brick bats 40 to 50 mm nominal size) inside plastering 15 mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a floating coat of neat cement slurry and making channels in cement concrte 1:2:4 mix ( 1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) finished smooth complete including curing & testing (I) Inside size 900 mm x 1200 mm and 1.50 meter deep including FRC cover with frame size 560 mm diameter (A) with 230 mm thick walls of brick masonry using bricks having crushing strength not less than 35 Kg / Sqcm in cement mortar 1:5 (1 cement : 5 coarse sand) (1) A-type depth 0.90 meter for 150 mm diameter sewer.
Constructing manhole with R.C.C top slab in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrte 1:3:6 mix (1 cement : 3 coarse sand : 6 brick bats 40 to 50 mm nominal size) inside plastering 15 mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a floating coat of neat cement slurry and making channels in cement concrte 1:2:4 mix ( 1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) finished smooth complete including curing & testing (I) Inside size 900 mm x 1200 mm and 1.50 meter deep including FRC cover with frame size 560 mm diameter (A) with 230 mm thick walls of brick masonry using bricks having crushing strength not less than 35 Kg / Sqcm in cement mortar 1:5 (1 cement : 5 coarse sand) (2) B-type depth 1.50 meter for 300 mm diameter sewer.
Constructing of Brick masonry road gully chamber 500mm x 450mm x 600mm including 500mm x 450mm C.I. horizontal grating wih frame complete.
Constructing of Brick masonry road gully chamber 450mm x 450mm x 775mm with vertical gating complete.
Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(i) Inside dimensions 455mmx 610mm and 450mm deep for single pipe line. (more than 10 ton)
Drilling pilot borehole of size 250/300 mm at above site by mud flush direct rotery rig.
Reaming of 250/300 mm dia.Pilot borehole to size 550 mm dia. Incliding assembling ,lowering housing ,casing strainerpipers with gravel packing and clayball packing etc.
Development of cach water bearingzone coming across the full depth of tubewell by lowering 100 mm dia.Droplineand 32 mm dia airline for each water bearing Zone with suitabale capacity air compressar up to avilability of sand free discharge.
900 CFM /200 PSI capacity air compressar upto the availability of sand free discharge for upto 250 mtrs
Supply of M.S. E.R.W. plain end medium duty pipe confirming to IS 4270/1992 with laatest amendments in random lenth of 4 to 7 mtr. Of size 250 mm dia (minmum thicknes of 7.1 mm)
Screen Slotting of ERW pipe with minimum size of slot 6.75 cm X 6.35 cm X 1.59 mm (1/16") for 250 mm dia pipe
Supply of miscellenious bore material suitable to 250 mm dia pipes as following (A) MS Bore clamps made from M.S. plate with 3 holes on either side with nuts & bolts of std make of size 900X100X16 mm flat to 250 mm dia pipe.
Supply of miscellenious bore material suitable to 250 mm dia pipes as following (B) MS Bore Plug having 100mm height made from M.S. plate with 3 holes at equal distance on circumferrence for nut-bolts type, locking arrrangement with nuts-bolts & lock nuts of std make complete from 5 mm thick M.S. plate suitable for 250mm dia pipe.
Supply of miscellenious bore material suitable to 250 mm dia pipes as following (C) MS Bail Plug having length 0.45 mtr from medium class pipe as per I.S.S. suitable for 250 mm dia pipe.
Supply of miscellenious bore material suitable to 250 mm dia pipes as following (D) Steel bent plate suitable for ERW pipe for 250mm dia (size:200 X 150X6 mm)
Electrologging of Pilot bore hole with carting.
Geohydrological ground water investigation including water sample chemical analysis
Providing, supplying and commissioning ISI mark CI D/F Reflux Valves of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores stacking etc. complete. Reflux valves PN 1 IS 5312 with ISI mark size: 100 mm
Providing and laying in trenches galvanised mild steel tubes (Midium grade) of the following nominal bore, and tube fitting (Earthwork in trenches to be measured and paid for separately (H) 80mm
Providing and laying Cement concrete1:2:4 (1 cement : 2 coarse sand : 4 crushed stone aggregates 20 mm. nominal size) and curing complete excluding cost of from work in : (a) Foundation and plinth.
Extra rate for constructing B.B masonry for every additional depth 0.10 meter or part thereof over item 24.27 (I) for depth from 0.90 meter to 1.50 meter.
Extra rate for constructing B.B masonry for every additional depth 0.10 meter or part thereof over item 24.27 (II) for depth from 1.50 meter to 2.25 meter.
Extra rate for constructing B.B masonry for every additional depth 0.10 meter or part thereof over item 24.27 (III) for depth from 2.25 meter to 3.15 meter.
Providing and fixing double coated Syntex PVC. (ISI) water tank of required capacity each with all necessary fittings and connection etc. complete on terrace.with Hoisting Charges for for above terrace 10000 ltr
Providing & erecting open well type horizontal mono block pump set with stainless steel body having following specification (A-1) 0.75 H.P. single phase open well motor pump set having discharge of 170 LPM @ 20 mtr. head suitable for 25 mm dia delivery pipe with control panel Cat. II
Supplying & erecting approved make Automatic liquid level controller 6A. with sensor testing as per instruction of Engineer in charge on site complete with wiring connection with existing wires , with copper conductor from pump to upper and lower tank.
Supplying & erecting approved make motor control cubical panel [Star delta] made from 16G CRCA sheet duly epoxy powder painted inside and outside with hinged doors and locking with suitable size of ON - OFF isolator (AC 3 / 23 duty) main fuses. Digital volt and current meter (in a single unit) with micro controller based control unit and current sensing single phasing preventer electronic overload protection, over voltage (Programmable) protection and under voltage (Programmable) protection, prod less dry run protection programming facility for setting of all parameter like overload current, high voltage limit, low voltage limit, dry run limit with digital indication on seven segment LED display for any fault like over load, high voltage, low voltage, dry running single crimped, electronic star delta timer, feather touch start / stop push buttons to be erected on angle iron frame. Grouted on wall the contactors will be of L& T, Siemens, BCH make only) (a) DOL up to 5.0 H.P.
Supplying submersible pump set for bore of 150 mm. dia. Or, more having 3 phase motor capacity not more than 15 H.P. and discharge capacity having (a) (15 Stage) 480 to 330 L.P.M at the head 105 to 135 mtrs..suitable for 65 mm dia. delivery pipe Cat.III
Lowering of submersible motor pump set at the depth of following ,complete with required. Nos. and size of casing pipes erected by means of proper chain pulley block & pipe wrenches after checking of threads of each pipe with coupling to take the load of the pump set and pipe assembly filled up with water (c)Above 120 mtr.
SUB HEAD 9 - ELECTRICAL WORKS : Providing and erecting ISI Marked 3 core 120 Sq.mm XLPE insulated 11 KV armoured cable Aluminium conductor IS-7098 to be laid on wall with clamps or in provided cable trench / pipe approved manner as directed.
Providing, erecting, testing & commissioning approved make oil immersed ONAN cooled, double wound, core type indoor / outdoor copper wound 11KV/ 433V step down transformer of following capacities operating on 3 phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full temperature rise in oil not exceeding 45 Deg.C.at maximum ambient temp. of 50 Deg. C. complete with necessary radiator first filling of new transformer oil & standard fitting as below complying with IS 1180( Part 1 ):2014 standards with energy efficiency level 2 (a)250 KVA Max. allowable loses at 50 % of rated load is 0.98 KW and at full load is 2.93 KW
Providing and Installation of 250 KVA 11/0.433 KV , Dyn-11 compact switchgear substation (CSS) transforme with off circuit tap of rating +5 to-5 @ 2.5% comprising of following components ; as directed by EIC A) HT switcgear : 11kv 630A 21KA for 3 sec, Air Insulated non extinsible compact switchgear Type DV consisting of 1 Nos. Direct switch and 1 no fixed manual compace circuit breaker in Air with insulated SS enclosure with series trip self power micro processor based numerical relay for over current and earth fault protection inter connection between HT switchgear and transformer shall be using 1CX3X 120 sq mm al armounred XLPE cable as directed. system includs HT and LT metering components B) LT switch board 400 A 3P 50 KA fixxed manual MCCB with microprocessor based O/C E/F S/C relese as incommer cum outgoing. CSS cost excluds the transformer.
(R) Continuous rating of 250 KVA ,BHP not less than 309 BHP
75 KVAR APFCR PANEL
Providing and fixing MLTP panel having ATS switch as a main incommer and 400A copper busbar inclsive insulation sleve as incomer and having outgoing taps as 100A 4 Nos, 40 A 6 Nos,25 A 5 Nos, 40A timer switch 4 Nos with proper wiring and febrication as given SLD contractor has to certify the panel from CPRI approved vendor as Directed by EIC
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for (b) sheet steel double door (IP-43)(B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) (iv)12 way
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity (c)63 Amp.
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase 240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed 63A
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating 125A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing.
Providing and erecting metallic vitrified danger notice board for MEDIUM VOLTAGE installation to be erected as per IS.
Providing and erecting metallic vitrified danger notice board for HIGH VOLTAGE installation to be erected as per IS.
Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as required with necessary connection erected as directed.
Making trench in soft soil of suitable width of 90 cms deep for laying cable or locating the fault all over the run and backfilling the same and making the surface as normal ground.
Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cms. layer of sand above & below cable (16 bricks per meter)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(a) 4 core 2.5 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(a-1) 4 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(B) 4 core 6 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(B) 4 core 16 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (D) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
Supplying & laying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water having following size of dimensions and No of compartments (W x D x T) : 150mm x 38mm x 1.6mm with Three Compartments
Point wiring for Light Point / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.with medium class Rigid PVC pipe and accessories
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size in (a) with medium class Rigid PVC pipe and accessories Wire : (a) 2 wire 1.5 sq. mm
Additional Wire : Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size in (a) with medium class Rigid PVC pipe and accessories Wire : (b) 2 wire 2.5 sq. mm
Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling, complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling ,complete with 6A Modular type switches and following type of accessories erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling with following type accessories
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [II] For 6/16A Plug with 2-2.5 sq.mm Cu. Wire (a) with medium class Rigid PVC pipe and accessories
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [III] For 16A Plug with 2-4 sq.mm Cu. Wire (a) with medium class Rigid PVC pipe and accessories
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 32 mm rigid PVC pipe of 1.6-1.8 mm thickness
Supplying & erecting Electronic Type Cordless Call Bell erected on PVC/Metal board having portable bell push working on D.C. & bell on 230V A.C. supply with cells / battery
Supply & Installation of Heritage type Fan with 5 blade design with glass lamp shades with antique brass / metalic bronze finish of usha/orient/crompton equivalent having 270 CMM airflow and 1300mm sweep and size voltage of 220-240 V as directed/approved by EIC
Supplying & erecting approved make low noise decorative exhaust fan having square frame ABS body with inbuilt lowers & square frame.250mm with 1350 RPM Cat.II
SITC of Key tag Switches 30A Mechanical Switch 2M faceplate
Supply,installation, testing and commisioning of Wall Mounted wall light LED with die cast/ glass heritage construction, with LED lamp and driver.-
Supply,installation, testing and commisioning of Recessed Mounted 3x18W LED COB light with die cast construction, Double reflector, toughened glass cover with LED lamp and driver.
Supply,installation, testing and commisioning of 4W/Mtr LED strip light with indoor application with All require accessiers and Drivers LUMEN EFFICACY >90lm/W, PF >0.90, THD <20%, CCT 4000K
Supply,installation, testing and commisioning of Decorative light hanging light having Glass and brass finish with LED lamp and driver LUMEN EFFICACY >90lm/W, PF >0.90, THD <20%, CCT 4000K
Supply,installation, testing and commisioning of 20W LED WALL WASHER LIGHT WITH ip-67 protection, Aluminum dia cast BODY, 15'/30' LENSE DIFFUSER, LUMEN EFFICACY >80lm/W, PF >0.90, THD <20%, CCT 4000K, powder coated adjustable housing, with LED Panel and driver.
Supply,installation, testing and commisioning of IP-65 10-12W LED Bollard light with die cast aluminum die cast powder coated housing, reflector, toughened glass cover with LED lamp and driver.
Supply,installation, testing and commisioning of IP-65 3-6W LED Foot light with die cast aluminum die cast powder coated housing, reflector, toughened glass cover with LED lamp and driver.
Supply,installation, testing and commisioning of IP-65 3-6W LED Spike light with die cast aluminum 300 mm long spike, powder coated housing, reflector, toughened glass cover with LED lamp and driver.
SITC of chandelier Light
[D] Overall length of 4 Mtr. Average Thickness: 7mm. Top/ Bottom OD Dia A/F 89/145 mm ± 2mm approx. Approx. Weight of Pole 19 kg approx. (Without Base) Anchor Base (Size 250X250 & 12mm th.)
Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 45 x 45 x 100 cm. Deep in below ground level with plinth of 45 cm x 45 cm (or 45 cm dia x 45 cm) high upper ground level with necessary curing and finishing in approved manner. ( for 4 & 6 mtr pole)
Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out approx. 2mm thick box complete with bakelite connector strip 4way & hinged doors having locking arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of following size of box.: (b) 250mm x 200mm x 100mm [deep]
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. (c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e independent Earthing in normal soil. Length of Pipe : 3.00 mtrs Back filling Compound :2 nos Bags of 25 Kg.
Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp.
Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness .
SITC of Faceplate for RJ45 Port with ABS /Metal Body square plate, dimension as per commercially available modular office furniture. Shall Have Icons, Shutter, Screw Cover, Label Cover, Jack holder with neccessory connections(A) 1-port
Supplying & erecting Push button type telephone instrument (A)BEETEL Secure / BPL/, SONY / PANASONIC or equivalent make
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction : [C] CAT - 6
Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections. (b) Armoured [Jelly Filled] - 50 Pair
SITC of Digital / PCM / TDM EPABX System having SMT design, system with flexible universal slots. Inbuilt Auto attendant facility, Minimum 15 Nos. conference, Analog extension line, Calling GSM, E&M line, PRI / EI & VOIP program me through Analog telephone digital key from Ethernet, public address cord, shall have unrestricted simultaneous dialing facility, QSIG protocol on PRI, 95 / STD / ISD / Local-Locking, Class of Service, Quick Dial-Single Digit dialing of any two external number, Once only ring device, Boss/Secretary-Do not disturb Facility, Power Down Mode, Hot Line, Hot Outward Dialing, Day Night Mode, Auto Call Back, Barge-in, Call Pick Up & Call Transfer, Call transfer while Ringing with Voice Guide System, (DISA), Caller ID (CLI), CLI Base ECF, CLI Base routing Internet Ready Port, External Music Port, Call Budgeting, Call Most Calculation (ASMDR), DID Direct Inverse Dialing, External Music Input, Fax Homing, Global Directory Printing with following capacities[D] No of Extension 64, No of Junctions 12, 8 Port IP Resource in-built, 4 Port Web base Video Conferencing, No of expandable ports : 240, Operators Console - 01 Compatible : ISDN and Networking
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. RG-6 Cable
Supply, Installation, Testing & Commissioning of 2 Megapixel HD Dome Camera, HD1080p,1/2.7" CMOS, 24 pcs LEDs, 20m IR, Outdoor IR Bullet, ICR, 0.1 Lux/F1.2, 12 VDC, Smart IR, DNR, DWDR, IP66, 3.6mm lens, 4 IN 1 OUTPUT
Supply, Installation, Testing and Commissioning of 32-Channel Network Video Recorder recording with 4TB HDD with all require installation and integration with all camera system, 16 Turbo HD input, 32-ch video&1-ch audio input, 2 SATA interface, 1280×720P: 25(P)/30(N) fps/ch, 380 1U caseW/O HDD with all require software
Installation, Testing and Commissioning of 32" Full HD LED monitor with Power Cord complete as required & necessary video cards complete as required (if required). Make - Sony, Samsung, Philips
Providing & Erecting Netwrok rack with following capacity with Necessary cooling fan,Cable manager,6A PDU,equipment rack with necessary mounting accessories.26U
SITC of 24 x 10/100/1000BASE-T PoE ports 4 x Gigabit RJ45/SFP Combo ports Advanced L2 switching and security features L2+ Static Routing Optional “standard mode” or “surveillance mode” management user interface 193 W PoE budget
SITC of High power 2-way flush mount ceiling speaker for excellent reproduction , Wide frequency response and adjustable tweeter for optimum directivity. following Input Power ,Impedance :- 500/1k/2kΩ ,Frequency Response :- 90-18,000Hz ,SPL at 1kHz (1W/1m) :- 91dB erected as directed by engineer in charge(A) 30 Watt Woofer 150mm (5”), Tweeter 25mm (1”)
Providing & erecting Following capacity Amplifier WITH BUILT-IN DIGITAL PLAYER , MEDIUM WATTAGE PA MIXER AMPLIFIER, Built-in MP3 player with remote control for USB, SD/MMC card reader approx 2% THD ,Frequency Response :- 50-15,000Hz ±3dB Tone Controls -Bass:Treble ,Speaker Output :- 4Ω, 8Ω, 70V & 100V ,Digital Player MP3 Player with USB, SD and MMC Card Reader .(C) 500 Watts (max 750 W RMS output)
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. (A)Speaker cable Single pair, 2-core, 1.5 sqmm
Supply installation testing and commissioning of roof top solar system with 20 years performance warranty , cost include high efficiency solar SPV module, require earthing, Lightening arrestor, supporting fabrication hot dip GI structure with paint, all require wiring, ACDB DCDB, Solar power meter, and inverter as require with consideration of 1-Year DLP
Liaoning with Local Electricity Board & Electrical Inspector for upgradation of Existing 11KV HT Power & Electrical inspector certification in totality to charge the power other related accessories. etc. complete. Charges for doing liasioning work for obtaining the necessary clearances from the Electrical inspector/competent Authorities for the total Electrical installation, Elevator Inspection, co-ordinating with various agencies. All necessary drawings, calculations, test certificates, etc. as required by the seauthorities shall be prepared and furnished by the EPCV endor. Any modification / rectification as required by these authorities shall be carried out by the EPCV endor at free of cost. The fees required to be paid to these authorities for inspection shall be borne by Owner on production of documentary evidences.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment omplete as required.
Supplying, installation, testing & commissioning of addressable manual call point having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector having IS-11360-1985 or BS 5446 Part I-1977 & Part VII –1985 (VdS approved) or NFPA72 ( UL/ULC/FM approved) with Latest ammendment complete with mounting base complete as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(C) 3 1/2 core 50 Sq. mm ( 25 Sq. mm 1/2 core)
SUB HEAD 10 - HVAC WORKS : Installation, Testing and Commissioning of VRF system with Odu of minimum 3number of 26hp and idu of various capacity 1.5 tr to 5tr 21 numbers as per drg and detail given by arch. or EIC. system with wired/remote reciever and tower unit 4 number of 4tr complete with commisioning and testing of leak/ pressure testing and fitting with all required drain pipe and copper wiring and piping , insulation for indoor and outdoor unit.complete. Make - bluestar, Daikin, O'general.
SUB HEAD 11 - HORTICULTURE WORKS : Filling Garden soil lvelling it as per required slopes. application of required pesticides and chemical fertiliser and weed free including watering, ramming and consolidating etc., complete.
Plumeria alba Tree: Supply, stacking and plantation of 2.7 mtr height, Girth thick of 75 to 100 mm and having Pit size 750mm X 750mm X 750mm incluing pot. Soil to used will be garden soil (Well drained soil) and Fertilizer Organic Manure, Farm yard manure, fungicide, insecticide, pesticide and basal dose will be used as per direction of the engineer-in-charge.
Murraya exotica Tree: Supply, stacking and plantation of 2.7 mtr height, Girth thick of 75 to 100 mm and having Pit size 750mm X 750mm X 750mm incluing pot. Soil to used will be garden soil (Well drained soil) and Fertilizer Organic Manure, Farm yard manure, fungicide, insecticide, pesticide and basal dose will be used as per direction of the engineer-in-charge.
Hamelia patens Shrub: Supply, stacking and plantation of 0.6 mtr height, Girth thick of 25 mm. Soil to used will be garden soil (Well drained soil) and Fertilizer Organic Manure, Farm yard manure, fungicide, insecticide, pesticide and basal dose will be used as per direction of the engineer-in-charge.
Pisonia alba Shrub: Supply, stacking and plantation of 0.6 mtr height, Girth thick of 25 to 40 mm. Soil to used will be garden soil (Well drained soil) and Fertilizer Organic Manure, Farm yard manure, fungicide, insecticide, pesticide and basal dose will be used as per direction of the engineer-in-charge.
Hydrangea macrophylla Shrub: Supply, stacking and plantation of 0.6 mtr height, Girth thick of 25 to 40 mm. Soil to used will be garden soil (Well drained soil) and Fertilizer Organic Manure, Farm yard manure, fungicide, insecticide, pesticide and basal dose will be used as per direction of the engineer-in-charge.
Roheo tricolor Shrub: Supply, stacking and plantation of 0.6 mtr height, Girth thick of 10 to 18 mm. Soil to used will be garden soil (Well drained soil) and Fertilizer Organic Manure, Farm yard manure, fungicide, insecticide, pesticide and basal dose will be used as per direction of the engineer-in-charge.
Epipremnum aureum Neon: Supply, stacking and plantation of 0.6 mtr height, Girth thick of 10 to 18 mm. Soil to used will be garden soil (Well drained soil) and Fertilizer Organic Manure, Farm yard manure, fungicide, insecticide, pesticide and basal dose will be used as per direction of the engineer-in-charge.
Zephyranthes candida Shrub: Supply, stacking and plantation of 0.6 mtr height, Girth thick of 10 to 18 mm. Soil to used will be garden soil (Well drained soil) and Fertilizer Organic Manure, Farm yard manure, fungicide, insecticide, pesticide and basal dose will be used as per direction of the engineer-in-charge.
Zoyasia matt: Supply, stacking and laying of 0.06 to 0.09 mtr height, leafy structure as per direction of the Engineer-in-charge.
Plastic Agro Shade Nets, Packaging Type: Roll, Shape: Crop Support Net Shape Crop Support Net Color Green, Material Plastic Packaging Type Roll
Bougainvillae glabra Creeper: Supply, stacking and plantation of 0.6 mtr height palced in pot. Soil to used will be garden soil (Well drained soil) and Fertilizer Organic Manure, Farm yard manure, fungicide, insecticide, pesticide and basal dose will be used as per direction of the engineer-in-charge.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_4053.xls
BOQ • 0.64 MB
158586992.pdf
Tender Documents • 2.41 MB
158586994.html
Tender Documents • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .