Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAdmitted-Finance | ₹2.8 L | L1 | Admitted-Finance |
| 2 | L2₹3.0 LAdmitted-Finance MANIK COLONY OPP RAJA HOTEL AHILYABAI CHOWK KALYAN W 421 301 | KALYAN W | THANE | MAHARASHTRA | 421301 | ₹3.0 L | L2 | Admitted-Finance |
| 3 | L3₹3.4 LAdmitted-Finance | ₹3.4 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | J D ELECTRIC WORKS L2 | JADHAV & SONS L1 | SAAD ELECTRICALS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply & filling of High Quality 15 W-40 multivisco city lubricating Engine oil for Lubrication service and Maintenance for quarterly 20 Ltrs. | 60 | Ltr | 1,900 ₹1,14,000 | 1,800 ₹1,08,000 Lowest | 2,000 ₹1,20,000 |
| 2.00 | Supplying and erecting Air cleaner/Air filter element / fuel filter (spin on type ) 05 to 10 mm check kit for Single cylinder air compressor Cummins Air Compressor Kit contains the replacement piston, rings, gaskets, and pin clips required to repair the block auxiliary unit, check Engine cooling system (liquid-cooled air compressor. Diesel Engine maintenance is preventive in Nature. Suitable for DG set. | 6 | Each | 11,000 ₹66,000 | 10,800 ₹64,800 Lowest | 12,000 ₹72,000 |
| 3.00 | Carrying out servicing and maintenance as per manufacturer recommended schedule of maintenance manual as per Cummins India Ltd DG set with/without AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. | 12 | Months | 9,600 ₹1,15,200 | 9,200 ₹1,10,400 Lowest | 12,000 ₹1,44,000 |
Tender Value
₹2.9 L
EMD Value
₹3,000
Closing Date
20 Jul 2026, 3:00 pmClosed
Executive Engineer
Ulhasnagar Municipal Corporation
E-Tender for for Annual COMPREHENSIVE MAINTENANCE of 63.5 kVA D.G. set at Information Technology Dept. UMC Head Office Ulhasnagar-3
2026_UMC_1317930_1
UMC/Elect/T-2/15/2026-27
Open Tender
Electrical Works
Item Rate
Ulhasnagar Municipal Corporation
Please refer Tender documents.
2 documents required · 2 mandatory
₹354
₹3,000
23 Jul 2026
14 Jul 2026
21 Jul 2026
14 Jul 2026
20 Jul 2026
14 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & filling of High Quality 15 W-40 multivisco city lubricating Engine oil for Lubrication service and Maintenance for quarterly 20 Ltrs. | 60 | Ltr | - | - |
| 2 | Supplying and erecting Air cleaner/Air filter element / fuel filter (spin on type ) 05 to 10 mm check kit for Single cylinder air compressor Cummins Air Compressor Kit contains the replacement piston, rings, gaskets, and pin clips required to repair the block auxiliary unit, check Engine cooling system (liquid-cooled air compressor. Diesel Engine maintenance is preventive in Nature. Suitable for DG set. | 6 | Each | - | - |
| 3 | Carrying out servicing and maintenance as per manufacturer recommended schedule of maintenance manual as per Cummins India Ltd DG set with/without AMF panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with distilled water, checking V belts with necessary adjustment, checking and retightening of nut bolts including coupling bolts of engine and alternator, checking & cleaning of radiator and leakage testing checking of radiator & fuel supply hose pipes, checking of AVR, excitation diodes, its connections confirming proper output voltage. checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator and Submit the servicing report to engineer in charge. | 12 | Months | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
TD.pdf
Tender Documents • 1.03 MB
BOQ_2259142.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].