Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC 4C 1 KESHAR VIHAR NEAR NSF INTER COLLEGE BALAJI PURAM SHAHGANJ AGRA 282010 | AGRA | UTTAR PRADESH | 282010 | L1 | Accepted-AOC The L1 bidder is techno-commercially eligible and the rate quoted is reasonable and justified, which has been accepted by the Competent Authority, NK Area. | |
| 2 | L2₹13.2 L+₹23,589.75 (1.83%)Rejected-Finance AT RAY COLLIERY POST CHURI DIST RANCHI 829209 | HAZARIBAGH | JHARKHAND | 829209 | L2 | Rejected-Finance L2 |
Tender Value
₹13.9 L
EMD Value
₹17,500
Closing Date
11 Oct 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO EnM NK
GM Office, NK Area
Rep., maint. of main 11kVOHL feeder repl. of damaged and rusted poles, maint. earth continuity and cradling as req for strengthening of 11kV OHL structure from KDH Old SS to QNo. 01 SS and from backside of Rohini SS to QNo. 02 SS under PND OCP.
2022_CCL_257007_1
GM (NK)/EnM/e-NIT/2022-23/ 115
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Purnadih OCP, NK Area
As per NIT
2 documents required · 2 mandatory
₹17,500
20 Oct 2022
21 Sept 2022
12 Oct 2022
22 Sept 2022
11 Oct 2022
22 Sept 2022
22 Sept 2022 - 29 Sept 2022
Amount
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required. Above 10.00 Metre and upto 12.00 Metre.
Supplying and erection of stay set complete (galvanized) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle (20 mm x 60 cm), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter and above including binding etc as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) V shape cross arm for two 11 KV over head line conductors complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height, complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required
Erection of disc/ pin insulator for 11 KV over head lines as required
Supply of 8 / 6 SWG G.I. wire
Erection of G.I. Wire No. 8 SWG including binding etc. as required.
Erection of cradle Guard as required.
Dismantling of pole / street light standard / strut embedded in cement concrete foundation etc as required.
Dismantling of over head lines comprising of copper / aluminium over head conductor, G.I. wire, cross arms, insulators etc as required
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal/ coke and salt ) as required
Supplying of GI strip of size 50 x 6 mm for earthing continuity from Lightening arrestor on OHL to earth pit. 13m x 2.5kg/m x 5 = 162.50 kgs.
Fixing of GI strip of size 50 x 6 mm for earthing continuity from Lightening arrestor on OHL to earth pit. Fixing and labour charges of Sl. No. 19.
Proper strengthening of base of poles at ground with cement concrete of specified grade at different location (weak base and vulnerbale poles in the OHL feeder). Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level, 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size).
Painting of poles with Aluminium paint post applying Red oxide zinc chromate primer (two coats); i. for 11kV OHL between KDH Substation and Q-1 Substation: 102 nos and ii) for 11 kV OHL between Rohini Substation boundary and Q-2 Substation: 55 nos.
Writing of respective feeder name/nos., voltage and pole nos. on poles with paint and color coding of respective feeders and poles. i) for 11kV OHL between KDH Substation and Q-1 Substation: 102 nos and ii) for 11 kV OHL between Rohini Substation boundary and Q-2 Substation: 55 nos.
Total impact of GST for the purpose of CTC
M/S M. S. Construction
stage.html
html • 0.04 MB
techsummary_265742.pdf
PDF • 0.22 MB
finsummary_265742.pdf
PDF • 1.19 MB
AOC_115.pdf
PDF • 3.29 MB
finance_265742.pdf
PDF • 0.22 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .